® D ire ct / In d ire ct L in e a r L u min a ire s w w w. s i m k a r. c o m ® Redefined. Simkar has redefined the direct / indirect luminaire T he Altus+ Classic remains the standard in the industry as one of the best direct / indirect luminaires for general commercial lighting applications. The Altus+ Classic offers a shallow design and an extensive family of T5, T5HO, T8 and twin-tube T5 compact fluorescent luminaires that are available in center and dual perforated basket configurations. The open design features a post painted reflector that provides 92% reflectance to ensure peak performance, distributing high quality direct / indirect light uniformly throughout your work area. Specially tooled perforated steel, matched with the newest thin high transmission inlays, delivers comfortable and efficient lighting. The Altus+ Classic center model is also available with a deep prismatic high diffusion lens that provides a pleasing balance between brightness of the reflectors and the lens itself. The rigid construction enhances unit strength and ease of installation while the architectural low-profile design projects a clean, modern appearance. The Altus+ Classic is available with unique features such as light traps, vented heat removal, and debris guards. They are manufactured in the USA and designed for increased sustainability. w w w. s i m k a r. c o m Features Excellent Light Distribution Matte white, 92% highly efficient post-painted reflector Efficient Optical System High transmission open lens or optimized perforated metal diffuser and shaped reflectors Optimized Perforated Diffuser with High Transmission Inlay Improves light distribution, reduces glare, hides source Choice of Configurations Center or dual diffuser styles in sizes for 1’x4’, 2’x2’ and 2’x4’ ceiling grids Shallow Fixture Depth 3.75” housing fits most challenging plenums Light Trap The Altus+ Classic Light Trap prevents light spillover at diffuser ends. The lens/perforated metal diffuser pivots on the Light Trap to swing open for easy re-lamping. Debris Guard Optional extruded clear plastic guards between the lens and reflector to minimize the infiltration of debris and insects. Flow-Thru Air Design The Altus+ Classic luminaire offers an optional heat transfer design to improve air circulation through the luminaire and into the plenum space. (Only available without Debris Guard). Configurations and Sizes Center Center Configuration Shielding: Open, Frosted Prismatic Acrylic Sizes: 1 x 4, 2 x 2, and 2 x 4 Lamping: T5, T5HO, TT5*, and T8 Center Configuration Shielding: Perforated Diffuser with Inlay Sizes: 1 x 4, 2 x 2, and 2 x 4 Lamping: T5, T5HO, TT5*, and T8 Mounting Options Recessed: 1 x 4, 2 x 2, and 2 x 4 Surface: 1 x 4, 2 x 2, and 2 x 4 Mounting Options Recessed: 1 x 4, 2 x 2, and 2 x 4 Surface: 1 x 4, 2 x 2, and 2 x 4 Dual Applications Applications include private offices, open office areas, retail applications, public circulation areas, classrooms, and any general indoor space. Diffusers are designed with the most advanced acrylic formulations and an exclusively tooled perforated metal pattern. Dual Configuration Shielding: Perforated Diffusers with Inlays Sizes: 2 x 2 and 2 x 4 Lamping: T5, T5HO, TT5*, and T8 Mounting Options Recessed: 2 x 2 and 2 x 4 Surface: 2 x 2 and 2 x 4 With a wide range of lamp options, the Altus+ Classic has the looks and the latest technology for any direct / indirect application. Please visit simkar.com/altusplus for photometrics and IES files, as well as application support and other useful information. * TT5 available in 2 x 2 only. Photometric Data 180 150 120 Across 45 Along 2 x 2 Center Open Perforated 180 120 150 Across 45 Along 2 x 4 Center Open Lens 90 175 90 500 60 60 350 1000 525 1500 0 Test Number: Luminaire Description: Catalog Number: Lamp: Fixture Watts: 150 180 Fixture Lumens: Fixture Efficiency: Across 30 UL678959 White painted steel housing with 92% high reflectance white reflector, optimized perforated diffuser with high transmission inlay ACC 22 OP 2 14T5 Two horizontal 14 Watt T5 linear fluorescent lamps rated at 1350 lumens each 33W 120 1977 79.1% 45 Along 2 x 2 Dual Open Perforated 0 Test Number: UL678965 Luminaire Description: White painted steel housing with 92% high reflectance white reflector, with acrylic frosted lens Catalog Number: ACC 24 OL 2 28T5 Lamp: Two horizontal 28 Watt T8 linear fluorescent lamps rated at 2625 lumens each Fixture180 Watts: 150 60W 120 Fixture Lumens: 4760 Fixture Efficiency: Across 90.7% 45 Along 2 x 4 Dual Open Perforated 90 200 90 500 60 60 400 1000 600 1500 0 Test Number: Luminaire Description: 30 30 0 30 UL678973 White painted steel housing with 92% high reflectance white reflector, optimized perforated diffuser with high transmission inlay ACD 22 OP 2 14T5 Two horizontal 14 Watt T5 linear fluorescent lamps rated at 1350 lumens each 33W 1885 75.4% Test Number: UL678970 Luminaire Description: White painted steel housing with 92% high reflectance white reflector, optimized perforated diffuser with high transmission inlay Catalog Number: ACD 24 OP 2 28T5 Lamp: Two horizontal 28 Watt T5 linear fluorescent lamps rated at 2625 lumens each Fixture Watts: 63W Fixture Lumens: 4078 Fixture Efficiency: 77.7% Consult simkar.com/altusplus for complete photometric performance data w w w. s i m k a r. c o m Catalog Number: Lamp: Fixture Watts: Fixture Lumens: Fixture Efficiency: Configuration Information Center • • • • 1x4 Shallow 3.75” deep housing for ease of installation Matte white, 92% highly efficient post-painted reflector Optimized perforated diffuser with high-transmission inlay Deep prismatic acrylic highly diffuse lens 3-3/4" 11-15/16" 2x2 and 2x4 3-3/4" Example: ACC 22 OP 2 14T5 E U1 BP 23-7/8" Series ACC = Altus+ Classic Center SACC = Surface Altus+ Classic Center Size Diffuser No. Lamps Wattage 22 = 2x2 OP = Open Perf. 1 17T8 = 17W T8 24” 24 = 2x4 OL = Open Lens 2 14T5 = 14W T5 22” 14 = 1x4 3** 24T5HO = 24W T5HO 22” 40TT5 = 40W Twin T5 22” Ballast Option Explanations: 50TT5 = 50W Twin T5 22” “PS” = Programmed Start; “HP” = High Performance 55TT5 = 55W Twin T5 22” “L” = Low Ballast Factor; “N” = Normal Ballast Factor; “H” = High Ballast Factor † Specify Manufacturer Consult factory for NEMA Premium ballasts TT5 lamps only available in 2x2 fixtures 32T8 = 32W T8 48” 28T5 = 28W T5 46” 54T5HO = 54W T5HO 46” “AR” not available with “DBG”. “DBG” not available with “AR” **Not available in 1x4 Ballast Options Voltage E = Electronic Instant Start U1 = 120V-277V PSL = T8 only, BF .71* 347 = 347V PSN = T8 only, BF .80* 480 = 480V PSH = T8 only, BF 1.15* D = Dimming † HE = Electronic T5HO only HPL = *T8 only, BF .77 HPN = *T8 only, BF .87 HPH = *T8 only, BF 1.18 Options AR = Air Return BP = Bulk Pack, Palletized 35K = 3500ºK Lamp Installed 41K = 4100ºK Lamp Installed ELS1 = Emergency (T8/T5 500/700 Lm) ELS2 = Emergency (T8 or T5 700 Lm) ELS3 = Emergency (T8, T5, TT5 1400 Lm) M/S = Labor saving Master/Satellite DBG = Debris Guard *For exact ballast factor see CEE listing for ballast qualification. NOTE: See spec sheets for a complete list of switching, options and accessories. Dual 2x2 and 2x4 • Twin reflector chambers for less glare • Matte white, 92% highly efficient post-painted reflector • Optimized perforated diffuser with high-transmission inlay 3-3/4" 23-7/8" Example: ACD 24 OP 2 24T5HO D U1 AR Series ACD = Altus+ Classic Dual SACD = Surface Altus+ Classic Dual Size Diffuser No. Lamps Wattage 22 = 2x2 OP = Open Perf. 2 17T8 = 17W T8 24” 24 = 2x4 14T5 = 14W T5 22” 24T5HO = 24W T5HO 22” 40TT5 = 40W Twin T5 22” Ballast Option Explanations: 50TT5 = 50W Twin T5 22” “PS” = Programmed Start; “HP” = High Performance 55TT5 = 55W Twin T5 22” “L” = Low Ballast Factor; “N” = Normal Ballast Factor; “H” = High Ballast Factor † Specify Manufacturer Consult factory for NEMA Premium ballasts TT5 lamps only available in 2x2 fixtures “AR” not available with “DBG”. “DBG” not available with “AR” 32T8 = 32W T8 48” 28T5 = 28W T5 46” 54T5HO = 54W T5HO 46” Ballast Options Voltage E = Electronic Instant Start U1 = 120V-277V PSL = T8 only, BF .71* 347 = 347V PSN = T8 only, BF .80* 480 = 480V PSH = T8 only, BF 1.15* D = Dimming † HE = Electronic T5HO only HPL = *T8 only, BF .77 HPN = *T8 only, BF .87 HPH = *T8 only, BF 1.18 Options AR = Air Return BP = Bulk Pack, Palletized 35K = 3500ºK Lamp Installed 41K = 4100ºK Lamp Installed ELS1 = Emergency (T8/T5 500/700 Lm) ELS2 = Emergency (T8 or T5 700 Lm) ELS3 = Emergency (T8, T5, TT5 1400 Lm) M/S = Labor saving Master/Satellite DBG = Debris Guard *For exact ballast factor see CEE listing for ballast qualification. NOTE: See spec sheets for a complete list of switching, options and accessories. Simkar • 700 Ramona Avenue • Philadelphia, Pennsylvania • 19120 • 800 239-5267 • www.simkar.com ALTC10292014