Direct / Indirect Linear Luminaires

advertisement
®
D ire ct / In d ire ct L in e a r L u min a ire s
w w w. s i m k a r. c o m
®
Redefined.
Simkar has redefined the
direct / indirect luminaire
T
he Altus+ Classic remains the
standard in the industry as one of the
best direct / indirect luminaires for general
commercial lighting applications. The Altus+
Classic offers a shallow design and an extensive
family of T5, T5HO, T8 and twin-tube T5 compact
fluorescent luminaires that are available in center
and dual perforated basket configurations. The
open design features a post painted reflector
that provides 92% reflectance to ensure peak
performance, distributing high quality
direct / indirect light uniformly throughout your
work area. Specially tooled perforated steel,
matched with the newest thin high transmission
inlays, delivers comfortable and efficient lighting.
The Altus+ Classic center model is also available
with a deep prismatic high diffusion lens that
provides a pleasing balance between brightness
of the reflectors and the lens itself. The rigid
construction enhances unit strength and ease
of installation while the architectural low-profile
design projects a clean, modern appearance. The
Altus+ Classic is available with unique features
such as light traps, vented heat removal, and
debris guards. They are manufactured in the USA
and designed for increased sustainability.
w w w. s i m k a r. c o m
Features
Excellent Light Distribution
Matte white, 92% highly efficient
post-painted reflector
Efficient Optical System
High transmission open lens or
optimized perforated metal diffuser
and shaped reflectors
Optimized Perforated Diffuser
with High Transmission Inlay
Improves light distribution, reduces
glare, hides source
Choice of Configurations
Center or dual diffuser styles in
sizes for 1’x4’, 2’x2’ and 2’x4’ ceiling
grids
Shallow Fixture Depth
3.75” housing fits most challenging
plenums
Light Trap
The Altus+ Classic Light Trap
prevents light spillover at diffuser
ends. The lens/perforated metal
diffuser pivots on the Light Trap to
swing open for easy re-lamping.
Debris Guard
Optional extruded clear plastic
guards between the lens and
reflector to minimize the infiltration
of debris and insects.
Flow-Thru Air Design
The Altus+ Classic luminaire offers an optional heat transfer
design to improve air circulation through the luminaire and
into the plenum space.
(Only available without Debris Guard).
Configurations and Sizes
Center
Center Configuration
Shielding: Open, Frosted Prismatic Acrylic
Sizes:
1 x 4, 2 x 2, and 2 x 4
Lamping: T5, T5HO, TT5*, and T8
Center Configuration
Shielding: Perforated Diffuser with Inlay
Sizes:
1 x 4, 2 x 2, and 2 x 4
Lamping: T5, T5HO, TT5*, and T8
Mounting Options
Recessed: 1 x 4, 2 x 2, and 2 x 4
Surface: 1 x 4, 2 x 2, and 2 x 4
Mounting Options
Recessed: 1 x 4, 2 x 2, and 2 x 4
Surface: 1 x 4, 2 x 2, and 2 x 4
Dual
Applications
Applications include private offices, open office
areas, retail applications, public circulation areas,
classrooms, and any general indoor space.
Diffusers are designed with the most advanced
acrylic formulations and an exclusively tooled
perforated metal pattern.
Dual Configuration
Shielding: Perforated Diffusers with Inlays
Sizes:
2 x 2 and 2 x 4
Lamping: T5, T5HO, TT5*, and T8
Mounting Options
Recessed: 2 x 2 and 2 x 4
Surface: 2 x 2 and 2 x 4
With a wide range of lamp options, the Altus+
Classic has the looks and the latest technology
for any direct / indirect application. Please visit
simkar.com/altusplus for photometrics and IES
files, as well as application support and other
useful information.
* TT5 available in 2 x 2 only.
Photometric Data
180
150
120
Across
45
Along
2 x 2 Center
Open Perforated
180
120
150
Across
45
Along
2 x 4 Center Open Lens
90
175
90
500
60
60
350
1000
525
1500
0
Test Number:
Luminaire Description:
Catalog Number:
Lamp:
Fixture
Watts: 150
180
Fixture Lumens:
Fixture Efficiency:
Across
30
UL678959
White painted steel housing with 92% high
reflectance white reflector, optimized perforated
diffuser with high transmission inlay
ACC 22 OP 2 14T5
Two horizontal 14 Watt T5 linear fluorescent
lamps rated at 1350 lumens each
33W
120
1977
79.1%
45
Along
2 x 2 Dual Open Perforated
0
Test Number:
UL678965
Luminaire Description: White painted steel housing with 92%
high reflectance white reflector, with acrylic
frosted lens
Catalog Number:
ACC 24 OL 2 28T5
Lamp:
Two horizontal 28 Watt T8 linear fluorescent
lamps rated at 2625 lumens each
Fixture180
Watts: 150
60W
120
Fixture Lumens:
4760
Fixture Efficiency:
Across 90.7%
45
Along
2 x 4 Dual Open Perforated
90
200
90
500
60
60
400
1000
600
1500
0
Test Number:
Luminaire Description:
30
30
0
30
UL678973
White painted steel housing with 92% high
reflectance white reflector, optimized perforated
diffuser with high transmission inlay
ACD 22 OP 2 14T5
Two horizontal 14 Watt T5 linear fluorescent
lamps rated at 1350 lumens each
33W
1885
75.4%
Test Number:
UL678970
Luminaire Description: White painted steel housing with 92%
high reflectance white reflector, optimized
perforated diffuser with high transmission inlay
Catalog Number:
ACD 24 OP 2 28T5
Lamp:
Two horizontal 28 Watt T5 linear fluorescent
lamps rated at 2625 lumens each
Fixture Watts:
63W
Fixture Lumens:
4078
Fixture Efficiency:
77.7%
Consult simkar.com/altusplus for complete photometric performance data
w w w. s i m k a r. c o m
Catalog Number:
Lamp:
Fixture Watts:
Fixture Lumens:
Fixture Efficiency:
Configuration Information
Center
•
•
•
•
1x4
Shallow 3.75” deep housing for ease of installation
Matte white, 92% highly efficient post-painted reflector
Optimized perforated diffuser with high-transmission inlay
Deep prismatic acrylic highly diffuse lens
3-3/4"
11-15/16"
2x2 and 2x4
3-3/4"
Example: ACC 22 OP 2 14T5 E U1 BP
23-7/8"
Series
ACC = Altus+ Classic Center
SACC = Surface Altus+ Classic Center
Size
Diffuser
No. Lamps
Wattage
22 = 2x2 OP = Open Perf.
1
17T8 = 17W T8 24”
24 = 2x4 OL = Open Lens
2
14T5 = 14W T5 22”
14 = 1x4
3**
24T5HO = 24W T5HO 22”
40TT5 = 40W Twin T5 22”
Ballast Option Explanations:
50TT5 = 50W Twin T5 22”
“PS” = Programmed Start; “HP” = High Performance
55TT5 = 55W Twin T5 22”
“L” = Low Ballast Factor; “N” = Normal Ballast Factor; “H” = High Ballast Factor
† Specify Manufacturer
Consult factory for NEMA Premium ballasts
TT5 lamps only available in 2x2 fixtures
32T8 = 32W T8 48”
28T5 = 28W T5 46”
54T5HO = 54W T5HO 46”
“AR” not available with “DBG”. “DBG” not available with “AR”
**Not available in 1x4
Ballast Options
Voltage
E = Electronic Instant Start U1 = 120V-277V
PSL = T8 only, BF .71*
347 = 347V
PSN = T8 only, BF .80*
480 = 480V
PSH = T8 only, BF 1.15*
D = Dimming †
HE = Electronic T5HO only
HPL = *T8 only, BF .77
HPN = *T8 only, BF .87
HPH = *T8 only, BF 1.18
Options
AR = Air Return
BP = Bulk Pack, Palletized
35K = 3500ºK Lamp Installed
41K = 4100ºK Lamp Installed
ELS1 = Emergency (T8/T5 500/700 Lm)
ELS2 = Emergency (T8 or T5 700 Lm)
ELS3 = Emergency (T8, T5, TT5 1400 Lm)
M/S = Labor saving Master/Satellite
DBG = Debris Guard
*For exact ballast factor see CEE
listing for ballast qualification.
NOTE: See spec sheets for a complete list of switching, options and accessories.
Dual
2x2 and 2x4
• Twin reflector chambers for less glare
• Matte white, 92% highly efficient post-painted reflector
• Optimized perforated diffuser with high-transmission inlay
3-3/4"
23-7/8"
Example: ACD 24 OP 2 24T5HO D U1 AR
Series
ACD = Altus+ Classic Dual
SACD = Surface Altus+ Classic Dual
Size
Diffuser
No. Lamps
Wattage
22 = 2x2 OP = Open Perf.
2
17T8 = 17W T8 24”
24 = 2x4
14T5 = 14W T5 22”
24T5HO = 24W T5HO 22”
40TT5 = 40W Twin T5 22”
Ballast Option Explanations:
50TT5 = 50W Twin T5 22”
“PS” = Programmed Start; “HP” = High Performance
55TT5 = 55W Twin T5 22”
“L” = Low Ballast Factor; “N” = Normal Ballast Factor; “H” = High Ballast Factor
† Specify Manufacturer
Consult factory for NEMA Premium ballasts
TT5 lamps only available in 2x2 fixtures
“AR” not available with “DBG”. “DBG” not available with “AR”
32T8 = 32W T8 48”
28T5 = 28W T5 46”
54T5HO = 54W T5HO 46”
Ballast Options
Voltage
E = Electronic Instant Start U1 = 120V-277V
PSL = T8 only, BF .71*
347 = 347V
PSN = T8 only, BF .80*
480 = 480V
PSH = T8 only, BF 1.15*
D = Dimming †
HE = Electronic T5HO only
HPL = *T8 only, BF .77
HPN = *T8 only, BF .87
HPH = *T8 only, BF 1.18
Options
AR = Air Return
BP = Bulk Pack, Palletized
35K = 3500ºK Lamp Installed
41K = 4100ºK Lamp Installed
ELS1 = Emergency (T8/T5 500/700 Lm)
ELS2 = Emergency (T8 or T5 700 Lm)
ELS3 = Emergency (T8, T5, TT5 1400 Lm)
M/S = Labor saving Master/Satellite
DBG = Debris Guard
*For exact ballast factor see CEE
listing for ballast qualification.
NOTE: See spec sheets for a complete list of switching, options and accessories.
Simkar • 700 Ramona Avenue • Philadelphia, Pennsylvania • 19120 • 800 239-5267 • www.simkar.com
ALTC10292014
Download