Premium Industrial / 2, 3, or 4-Lamp T5, T5HO, T8
PROJECT INFORMATION
Project Name
Type
Catalog No.
Date
CONSTRUCTION
FEATURES
•
•
•
•
•
•
•
Available in 4' and 8' lengths
Apertured reflectors have 15% uplight
Spring loaded turret lampholders
6' lamp spacing
For individual or continuous row mounting
Channel ends double as joiners
Full depth end closures available
Heavy steel housing with longitudinal reinforcing
ribs for extra strength. Reflector die-embossed
with transverse ribs for maximum rigidity. Solid top
or 15% uplight versions with extruded openings
available.
FINISH
White painted parts are treated with a five stage
phosphate bonding process and finished with
a high reflectance baked enamel. LSR and M4R
reflectors specular room side, Mill finish aluminum
top surface.
BALLASTS
Energy efficient, thermally protected, automatic
resetting, Class P, high power factor, sound rated
ORDERING INFORMATION
KL
MODEL
SIZE
4 4'
8 8'
–
NO. OF LAMPS IN
CROSS SECTION
2 Two
3 Three
4 Four
ACCESSORIES
(ORDER SEPARATELY)
KZT Zip Tee Hanger - 1½" spacer on
T-bar ceiling
KTH Slide Clamp Tong Hanger
S18 18" Stem, canopy and 8° aligner
SS18 18", 45° Swivel Stem & Canopy
KHC 24" Chain Hanging Assembly
KLEC Full Depth End Closure
KLWG4 Wire Guard 4' lg. - 2 required per
8' fixture
KLEGG White Straight Blade Egg Crate
Louver 4' - 2 required per 8' fixture
OS1360K Occupancy/Daylight sensor kit,
120/277/347V, one relay, 360
Lens, snap on drop down adaptor,
quick connect wiring1
ELECTRICAL
Standard class “P”, thermally protected, autoresetting HPF ballast, sound rated A. CEE NEMA
Premium compliant. All ballast leads extend a
minimum of 6" through access location. NEC/CECcompliant ballast disconnect is standard.
CERTIFICATION
All luminaires are built to UL 1598 standards and
bear appropriate UL and cUL or CSA labels. Damp
location labeling is standard. Emergency-equipped
fixtures labeled UL 924.
EXAMPLE KL4-232-U-EU-GLR-PAF
–
KL Premium
Industrial
A, unless otherwise specified. CEE NEMA Premium
compliant.
–
–
LAMP TYPE
REFLECTOR TYPE
VOLTAGE
28 4', T5: 28 Watt
32 4', T8: 32, 30, 28 or
25 Watt
54 4', T5HO: 54 or 51
Watt
U Apertured Reflector for
Uplight
ST Solid Top (No Uplight)
M4RST Solid Top Reflector
with 95% Reflective
Specular Silver Finish
M4RU Apertured Reflector
with 95% Reflective
Silver Finish
U 120V-277V
347 347V
OPTIONS
GLR
GMF
EL
BC
Fast Blow Fuse
Slow Blow Fuse
Emergency Battery Pack
Branch Circuit Plug-on Wiring
System (See options section
for details.)
PAF Paint After Fabrication
NYC NYC Compliant
NYCU NYC Compliant, Union Label
BALLAST
E Electronic T8, Instant Start
4E 4-Lamp Electronic T8, Instant Start
EP Electronic, Program Start
4EP 4-Lamp Electronic, Program Start
For others available, see Ballast Options.
Use programmed start ballast. Not recommended for use with instant start. For more occupancy/daylight harvesting sensor accessories see Technical section.
1
Page 1/2 Rev. 07/23/13
© 2013 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.
701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
INDUSTRIALS / KL BI-PIN
KL BI-PIN
Premium Industrial / 2, 3, or 4-Lamp T5, T5HO, T8
PHOTOMETRIC DATA
ZONAL LUMEN SUMMARY
Zone
LUMINAIRE DATA
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
KL4-232-U
KL Industrial
1' × 4' 2-Lamp Industrial with
Apertured White Reflector
R2P32
0.95
FO32/41K
2900
74
N/A
0º = 1.27 90º = 1.30
Length: 4.00
Width: 1.02
Height: 0.00
Ballast
Ballast Factor
Lamp
Lumens per Lamp
Watts
Shielding Angle
Spacing Criterion
Luminous Opening
in Feet
1090
1807
3314
4396
179
263
518
817
5212
18.8
31.1
57.1
75.8
3.1
4.5
8.9
14.1
89.9
ENERGY DATA
20.9
34.7
63.6
84.3
3.4
5.0
9.9
15.7
100.0
INDOOR CANDELA PLOT
RCR
70
94
85
77
71
65
60
55
51
48
45
80
50 30
90 86
78 71
68 60
60 52
53 45
48 39
43 35
39 31
36 28
33 26
10
82
66
54
46
39
34
30
26
23
21
70
90
81
74
67
62
57
53
49
46
43
70
50 30
86 83
75 69
65 58
58 50
51 44
46 38
42 34
38 31
35 28
32 25
10
79
64
53
45
38
33
29
26
23
21
50
80
69
60
53
48
43
39
35
33
30
50
30
77
64
55
47
41
36
32
29
26
24
10
74
61
50
42
36
32
28
25
22
20
89.9%
Luminaire Efficacy Rating (LER)
IESNA RP-1-1993 Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
67
Non-Compliant
$3.58 based on
3000 hrs. and
$0.08 per KWH
AVG. LUMINANCE (Candela/Sq. M.)
COEFFICIENTS OF UTILIZATION (%)
RC
RW
1
2
3
4
5
6
7
8
9
10
Total Luminaire Efficiency
Average Luminance Angle
Luminaire
Test 10183 Test Date 1/8/03
Lumens % Lamp % Fixt.
0
0
62
51
42
36
31
27
24
21
19
17
0
30
40
45
50
55
60
65
70
75
80
85
0.0
22.5
45.0
67.5
90.0
3654
3616
3578
3544
3509
3459
3387
3296
3155
2956
2674
2149
3654
3622
3595
3582
3579
3569
3493
3477
3595
3374
3464
2967
3654
3671
3706
3712
3776
3923
3894
3652
3718
4210
3342
2876
3654
3726
3788
3921
4104
3905
3704
3839
4327
4353
2370
2785
3654
3717
3833
4000
4059
3827
3667
3964
4536
3955
2355
2815
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
DIMENSIONAL DATA
MOUNTING ACCESSORIES
9813/16"
887/8"
2"
2"
11/8"
15/16"
431/32"
4913/32"
NOTE: Fixtures with T5/T5HO
lamping are 48" and
98" in length.
2"
497/16"
39½"
2"
15/16" 11/8"
39½"
431/32"
KHC
S18
43/16"
61/8"
35/8"
6"
133/8"
KZT
KTH
A: 7/8" Diameter knockout
B: .570" × .656" Strain Relief knockout
E: 11/8" Diameter knockout
NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification.
Page 2/2 Rev. 07/23/13
© 2013 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.
701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
INDUSTRIALS / KL BI-PIN