EFFECTIVE: 21-JUL-11 VERTICALLY MOUNTED MOTOR PRINT: EXPLOSION PROOF FRAME: 254,256TC,TCV BASIC TYPE: LF,LV,NF,NV SHEET: SUPERSEDES: 31-JAN-07 09-2358 1 OF 1 P T AJ BF 4 HOLES AA SIZE CONDUIT AG C AF BV AC AB BB AH AK BD ES U UNITS IN MM C P 28.56 725 13.19 335 ALL DIMENSIONS ARE IN INCHES AND MILLIMETERS U T AA AB AC AF AG -.001 4 1.63 41 UNITS IN MM 1.625 41.28 11.50 292 1 1/2 NPT 8.25 219 BB MAX BD MAX BF .25 6 10.00 254 1/2 13 X .75 2 3.13 80 BV 10.00 254 24.81 630 ES MIN SQ KEY 2.91 74 .313 7.95 AH 3.75 95 5 AJ AK -.003 7.250 184.15 8.500 215.90 TOLERANCES 1: ALL ROUGH CASTING DIMENSIONS MAY VARY BY .25" DUE TO CASTING AND/OR FABRICATION VARIATIONS. 2: TAP SIZE AND BOLT PENETRATION ALLOWANCE .004 T.I.R. .004 T.I.R. .002 T.I.R. 3: CONDUIT OPENING MAY BE LOCATED IN STEPS OF 90 DEGREES, STANDARD AS SHOWN WITH CONDUIT OPENING DOWN. 4: LARGEST MOTOR WIDTH. 5: DIMENSION MEASURED WITH MOTOR IN VERTICAL POSITION SHAFT DOWN. 6: TOLERANCES SHOWN ARE IN INCHES ONLY. ISSUED BY 09-2358/B Nidec Motor Corporation St. Louis, Missouri INFORMATION DISCLOSED ON THIS DOCUMENT IS CONSIDERED PROPRIETARY AND SHALL NOT BE REPRODUCED OR DISCLOSED WITHOUT WRITTEN CONSENT OF NIDEC MOTOR CORPORATION E. WENDT APPROVED BY K. POTTER IHP_DP_NMCA (MAR-2011) SOLIDEDGE FACE RUNOUT PERMISSIBLE ECCENTRICITY OF MOUNTING RABBET PERMISSIBLE SHAFT RUNOUT