Building Toronto and East York District 100 Queen Street West Toronto, ON M5H 2N2 Tel: 4163927539 This card must be kept posted in a conspicuous place on site of construction. PERMIT DRAWINGS FOR YORKVILLE VILLAGE MECHANICAL PENTHOUSE BUILDING PERMIT REV.1 13 147448 BLD 01 BA Site Address 87 AVENUE RD Project Description Other(BA) Date Issued Tuesday October 14, 2014 Ann Borooah Chief Building Official and Mario Angelucci Deputy Chief Building Official (Municipal addresses shown in drawings are for reference purposes only, please refer to actual permit card for accuracy). Kasian Architecture Ontario Inc 85 Hanna Avenue, Suite 300 Toronto, ON Canada M6K 3S3 T 416 583 3600 F 416 583 3610 www.kasian.com N 5000 A1-D-05-03 C1 3000 D1 5500 12 E1x E1 5500 5300 F1 G1 2000 H1 J1 5500 5500 L1 K1 7300 5500 M1 N1 7300 5500 P1 5500 5500 Q1 R1 7300 5500 S1 5500 7300 14A 2 2 EXISTING AIR HANDLING ROOM M101 2 2 2 7 5 EXISTING BOILER ROOM M102 4100 12A 10 122460 2 EXISTING SHED TO REMAIN 10 EXISTING METAL ENCLOSURE FOR RETURN AIR TO REMAIN EXISTING LARGE LOUVER ABOVE SHED TO REMAIN 2000 11Ax EXISTING EXIT SIGN AND PULL STATION TO REMAIN EXISTING CONC. BLOCK WALL TO REMAIN EXISTING DOOR TO REMAIN EXISTING STAIR AND HANDRAIL TO REMAIN 1118 EXISTING EMERGENCY GENERATOR ROOM M103 8 EXISTING RETAIL M104 MEZANINE 122460 EXISTING FHC 10 3167 EXISTING DOOR TO REMAIN 1 DN DN 4800 2 2 6100 15 4 DN 15 EXISTING MECHANICAL ROOM OPEN TO BELOW 11 9 EXISTING FHC STAIR NO.4 DN EXISTING FHC TO REMAIN EXISTING FHC 12 EXISTING AIR SHAFT TO REMAIN EXISTING ROOF DRAIN EXISTING DOOR TO REMAIN EFHC 13A EXISTING ROOF DRAIN OPEN TO BELOW EXISTING STAIR DOWN TO STREET LEVEL TO REMAIN. EXISTING ROOF DRAIN DN 3 STAIR NO. 3 DN 11 EXISTING ROOF DRAIN REFER TO MECH DRAWINGS T1 DN 4920 A1-D-05-03 DN B1x A1 1 FHC EXISTING AIR SHAFT TO REMAIN - REFER TO MECHANICAL 2 6 13 16 EXISTING ROOF TERRACE 02 01 2014-09-15 2013-04-09 REV. ISSUED FOR BUILDING PERMIT AMENDMENT ISSUED FOR BUILDING PERMIT YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW CLIENT EXISTING COOLING TOWER PIT 11A 3 NOTES - DEMOLITION PLAN SECOND FLOOR 2 14 3 6100 EXISTING ROOF DRAIN REFER TO MECHANICAL DRAWINGS FOR NEW LOCATION 17 2. EXISTING HOUSE KEEPING PAD TO BE REMOVED – EXTENT OF EXISTING PADS TO BE CONFIRMED BY CONTRACTOR. INDICATED LOCATION AND SIZES ARE APPROXIMATE. EXISTING TO REMAIN 10A 1. EXISTING STRUCTURAL COLUMNS TO BE REMOVED. REFER TO STRUCTURAL DRAWINGS. REFER TO DRAWING 2 /A1-02-01 FOR INFORMATION REGARDING EXISTING STRUCTURAL CONCRETE ROOF SLAB ABOVE. 3. REMOVE EXISTING ROOFING ASSEMBLY. EXISTING SKYLIGHT 4. EXISTING WALL TO BE REMOVED. PARTIAL CURB WALL TO REMAIN TO HEIGHT AS INDICATED IN SECTION 2 -A1-05-03 5. EXISTING FLOORING FINISH TO BE REMOVED THROUGHOUT 6. REMOVE EXISTING GLASS BLOCK FROM EXISTING OPENINGS IN EXTERIOR WALLS. 7. EXISTING STAIR TO BE REMOVED COMPLETE WITH ALL RAILINGS AND FINISHES. 1 A1-D-02-01 8. EXISTING PARTITIONS DOORS FRAMES FIXTURES SUSPENDED CEILINGS AND FINISHES TO BE REMOVED THROUGHOUT 9. EXISTING DOOR AND WALL TO BE REMOVED. 10. REMOVE EXISTING LOUVERS IN BRICK WALL. TOOTH OPENING TO PREP FOR NEW BRICK INFILL. ( NO CUT BRICKS) 11. REMOVE EXISTING MASONRY WALL. CONSULTANT 12. REMOVE EXISTING ROOF PARAPET AND PREP FOR EXTENSION OF MASONRY WALL AND STEEL STRUCTURE. REFER TO SECTIONS AND STRUCTURAL DRAWINGS 13. REMOVE METAL SIDING C/W ENTIRE METAL WALL ASSEMBLY ABOVE BRICK. 14. PROVIDE PROTECTION FOR EXISTING SKYLIGHTS. 15. REMOVE EXISTING FINISH SERVICE FLOORING AND INTERIOR WALLS THROUGHOUT. 16. REMOVE EXISTING SKYLIGHT AND ASSOCIATED RAILINGS AT ROOF LEVEL. TEMPORARILY REMOVE MIN ROOFING OVERBURDEN AND INSULATION IN ORDER TO LAP NEW ROOFING MEMBRANE (min. 600 mm) OVER EXISTING. PROTECT EXISTING ROOFING MEMBRANE. DEMOLITION PLAN_SECOND FLOOR PERMIT STAMP 17. TEMPORARILY REMOVE ROOFING OVERBURDEN AND INSULATION IN ORDER TO LAP NEW ROOFING MEMBRANE (min. 600mm) OVER EXISTING. PROTECT EXISTING ROOFING MEMBRANE. SCALE: 1 : 125 SEAL GENERAL NOTES: COORDINATE WITH FIRST CAPITAL BUILDING MANAGEMENT REGARDING ACCESS TO RESIDENTIAL ROOF TERRACE INCLUDING HOURS AND CONDITIONS OF ACCESS AND STAGING AREA. COORDINATE WITH FIRST CAPITAL BUILDING MANAGEMENT REGARDING DEMOLITION STORAGE OF DEMOLISHED AND REMOVED MATERIALS, WASTE HANDLING AND REUSE OF ANY MATERIALS. BEFORE COMMENCING WORK, CONFIRM FIRST CAPITAL MANAGEMENT REGARDING ANY ITEMS TO BE SALVAGED. CAREFULLY REMOVE IDENTIFIED ITEMS AND TURN OVER AS AGREED. CONSTRUCTION WORK IS SUBJECT TO THE CONDO CORPORATIONS RULES AND REGULATIONS. REFER TO SPECIFICATION FOR REQUIREMENTS FOR PROVISION OF TEMPORARY ENCLOSURES. REFER TO ELECTRICAL DRAWINGS REGARDING REQUIREMENTS FOR TEMPORARY POWER. REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR MECHANICAL DEMOLITION, PHASING AND TEMPORARY REQUIREMENTS. REFER TO STRUCTURAL DRAWINGS FOR PROTECTION OF EXISTING STRUCTURE DURING DEMOLITION. FIRE AND LIFE SAFETY: MAINTAIN EXISTING FIRE AND LIFE SAFETY RATINGS. COORDINATE WITH SPRINKLER CONSULTANT FOR REMOVAL AND RECONFIGURATION OF EXISTING AND NEW STANDPIPES AND SPRINKLERS AS NEEDED. REMOVAL OF EXISTING STRUCTURAL CONCRETE SLAB C/W EXISTING ROOFING REMOVAL OF EXISTING ROOFING ASSEMBLY FROM EXISTING STRUCTURAL CONCRETE ASSEMBLY DECK: INLCUDES REMOVAL OF EXISTING CONCRETE SLAB, INSULATION ROOFING INCLUDES COMPLETE REMOVAL OF ROOFING MEMBRANE, INSULATION, FILTER LAYER MEMBRANE, FILTER CLOTH AND BALLAST. ALSO INCLUDES REMOVAL OF VENTS AND BALLAST. REMOVE EXISTING PARAPET FLASHING UNLESS OTHERWISE NOTED METAL PARAPET FLASHINGS, MISCELLANEOUS METALS, MECHANICAL PENETRATIONS, SCREENS ETC. ALL EXISTING MECHANICAL PENETRATIONS DUCTING AND ATTACHED EQUIPMENT TO BE REMOVED (REFER TO MECH. DRAWINGS AND SPECIFICATION FOR EXTENT AND REFER TO MECHANICAL DRAWINGS FOR INFORMATION REGARDING PHASING. PHASING) VENTS METAL FLASHINGS, MISCELLANEOUS METALS SCREENS ETC. TO BE REFER TO STRUCTURAL FOR PROTECTION EXISTING STRUCTURES TO REMAIN. REMOVED. ALL EXISTING MECHANICAL PENETRATIONS DUCTING AND ATTACHED EQUIPMENTINFILL ALL EXISTING OPENINGS IN CONCRETE SLAB UNLESS OPENINGS INDICATED AS TO BE REMOVED (REFER TO MECH. DRAWINGS AND SPECIFICATION FOR EXTENT REUSED (REFER TO MECHANICAL) AND PHASING) VENTS METAL FLASHINGS, MISCELLANEOUS METALS SCREENS ETC. TO BE REMOVED. REFER TO STRUCTURAL FOR INFILL DETAILS. INFILL ALL EXISTING OPENINGS IN CONCRETE SLAB UNLESS OPENINGS INDICATED REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR NEW OPENING AS REUSED (REFER TO MECHANICAL) LOCATIONS INCLUDING NEW ROOF DRAINS. REFER TO STRUCTURAL FOR INFILL DETAILS. PREP TO RECEIVE NEW ROOFING PREPARE FOR INFILL OF EXISTING OPENINGS IN WALLS WITH BRICK PREPARE TO TOOTH IN TO EXISTING OPENING WITH NEW BRICK. NO CUT BRICKS, OPENINGS IN WALLS EXISTING FLOOR SLABS REPAIR AND MAKE GOOD ALL EXISTING OPENINGS IN WALLS AS NOTED REPAIR AND MAKE GOOD ANY ADDITIONAL TEMPORARY OPENINGS REQUIRED FOLLOWING REMOVAL OF EXISTING MECHANICAL PENETRATIONS. REPAIR AND MAKE GOOD ALL EXISTING OPENINGS IN STRUCTURAL CONCRETE SLAB. REFER TO STRUCTURAL.FOR INFILL DETAILS. REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS REGARDING REMOVAL OF MECHANICAL EQUIPMENT DUCTWORK AND PIPING PENETRATIONS. REMOVE EXISTING HOUSEKEEPING PADS AS REQURED. REFER TO ARCHITECTURAL SPECIFICATION FOR SURFACE PREPARATION. REFER TO STRUCTURAL FOR PROTECTION OF EXISTING STRUCTURAL SLAB. REMOVE EXISTING INTERIOR FLOORING FINISHES THROUGHOUT ( SERVICE FLOORING AND/OR TILE TYP.) REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATION FOR SURFACE PREPARATION READY TO RECEIVE NEW FINISH OR ROOFING. REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR NEW OPENING LOCATIONS. . REFER TO STRUCTURAL DRAWINGS FOR INFILL.DETAILS REFER TO MECHANICAL DRAWINGS FOR NEW OPENING LOCATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR INFILL ASSEMBLY DETAILS WHERE APPLIES. DENOTES EXISTING CONCRETE SLAB AND ASSEMBLY REMOVED C/W ALL METAL STRUCTURES, VENTS SCREENS AND MECHANICAL PENETRATIONS. DENOTES EXISTING ROOFING ASSEMBLY TO BE REMOVED D/W ALL METAL STRUCTURES, VENTS SCREENS AND MECHANICAL PENETRATIONS. THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF KASIAN ARCHITECTURE ONTARIO INC. THE COPYRIGHT IN THE SAME BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE PERMISSION OF KASIAN ARCHITECTURE ONTARIO INC. AND WHEN MADE MUST BEAR ITS NAME. THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD FOR ADJUSTMENT. PROJECT PROTECTION OF EXISTING TO REMAIN: PROTECT EXISTING EXTERIOR CLADDING (BRICK, METAL CLADDING, METAL ROOFING) AND ALL SURFACES, INCLUDING TERRACE ROOFS THROUGHOUT. PROTECT ROOF OF EXISTING RESIDENTIAL TERRACE AND RETAIL ROOF. PROVIDE PROTECTION OF EXISITING SKYLIGHTS TO RETAIL BELOW. REFER TO STRUCTURAL FOR REQUIREMENTS REGARDING TEMPORARY PROTECTION. MECHANICAL EQUIPMENT REMOVAL REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR NEW OPENING LOCATIONS INCLUDING NEW ROOF DRAINS. REFER TO MECHANICAL DRAWINGS FOR EQUIPMENT AND PENETRATION REMOVAL. REMOVAL OF EXISTING HOUSEKEEPING PADS REVIEW DRAWINGS AND PERFORM ON SITE REVIEW TO PROVIDE ASSESSMENT OF SECONDARY ARCHITECTURAL IMPLICATIONS RESULTING FROM MECHANICAL SEQUENCING, DEMOLITON AND REMOVAL OF EXISTING MECHANICAL EQUPMENT, DUCTS, PIPES AND ANY OTHER MECHANICAL PENETRATIONS. REFER TO STRUCTURAL DRAWINGS FOR PROTECTION OF EXISTING CLABS. PREP TO REPAIR AND MAKE GOOD TO RECEIVE NEW FINISH. DEMOLITION LEGEND DENOTES EXISTING HOUSE KEEPING PADS TO BE REMOVED. DENOTES EXISTING TO REMAIN HAZELTON LANES DENOTES EXISTING TO BE REMOVED 55,77, AND 87 AVENUE ROAD. TORONTO, ONTARIO, M5R 2G3 DRAWING TITLE EXISTING METAL ROOFING TO BE REMOVED DEMOLITION PLANSSECOND FLOOR AND MECHANICAL PENTHOUSE ROOFS DRAWING ISSUE MECHANICAL PENTHOUSE RENOVATION PRELIMINARY, NOT FOR CONSTRUCTION PROJECT NO. 130213 DRAWING NO. PLOT DATE SCALE 2014/09/15 As indicated DRAWN REVIEWED A1-D-02-01 Author Checker REVISION 1 5 A1-05-02 6 5 2 7 A1-05-01 A1-05-01 A1-05-02 A1-05-01 A1-04-01 A1x A1 3919 B1x B1 1000 5000 C1 D1 3000 E1x E1 5500 5500 5300 F1 2000 G1 5500 H1 J1 5500 7300 K1 L1 5500 M1 5500 7300 N1 P1 5500 5500 Q1 7300 R1 5500 S1 T1 5500 Kasian Architecture Ontario Inc W1 NEW FLOOR W1 NEW FLOOR EXISTING FLOOR EXISTING FLOOR 122460 UP NEW STAIR 3 RISERS @ 150 MM EXISTING DOOR TO REMAIN 1 DN EFHC A1-06-02 NEW ROOF EXTENT OF HOUSEKEEPING PADS TO BE CONFIRMED WITH MECHANICAL (TYP.) A1-04-01 600 12A NCR TYP. W1 4100 2000 6100 A1-05-01 MECHANICAL UNIT ON INTEGRAL FRAMED CURB 10A 6100 NEW CONCRETE CURB BELOW W1A EXISTING STAIR AND HAND RAIL TO REMAIN W1A INFILL EXISTING STAIR OPENING REFER TO STRUCTURAL W1A W3C W1 A INFILL OPENING INFILL ROOF OPENING WITH NEW FLOOR SLAB - REFER TO STRUCTURAL. MATCH ROOFING AND ROOF PAVERS AND SLOPE TO ADJACENT ROOF WRAP EXISTING AND NEW ROOF MEMBRANE MIN. 600 TYP. 3 W3B NEW ROOF DRAIN EXISTING SKYLIGHT NEW ROOF DRAIN PROVIDE POSITIVE SLOPE TO ROOF W4 DRAIN W1A A1-04-01 600 LAP EXISTING ROOF MEMBRANE WITH NEW MEMBRANE MIN. W4 4 EXISTING OPENING IN EXTERIOR WALL 4 A1-04-01 INFILLED WITH BLOCK (WALL TYPE 1A) W3C EXISTING DOOR TO REMAIN 11Ax 11A NEW OPENING IN CONC. SLAB FOR MECHANICAL REFER TO MECHANICAL DRAWINGS W1 W3C EXISTING EXIT SIGN AND PULL STATION TO REMAIN EXISTING CONCRETE BLOCK WALL TO REMAIN W3A REFER TO MECHANICAL FOR NEW CURBS - EXTENT AND DETAILS NEW CURBS REFER TO MECHANICAL EXISTING EMERGENCY GENERATOR ROOM M 103 REFER TO ELEVATION FOR NEW TREATMENT OF EXISTING LOUVERS THIS FACADE W3B NEW CONCRETE CURB NEW CURBS REFER TO MECHANICAL 600 BETWEEN HOUSEKEEPING SLABS EXISTING FLOOR 1-D-3 MCS 1 EXISTING DOOR TO REMAIN REFER TO MECHANICAL FOR RELOCATION OF FLOOR CONTROL CENTRE DRAINS MOTOR AS REQUIRED TO COORDINATE WITH NEW HOUSEKEEPING PAD EX. M.C.C. LOCATIONS 1470 +- EXPANSION TO MECHANICAL ROOM NCS 6100 MECHANICAL ROOM MCR 1 PROVIDE CONCRETE TOPPING TO FLOOR TO CREATE LEVEL AND FLUSH CONDITION WITH EXISTING AND NEW FLOOR SLABS NEW ROOF W1 NEW ROOF DRAIN REFER TO MECHANICAL (TYP.) N NEW CURB NEW CURB EXISTING CONC. ROOF SLAB A1-05-01 NEW STAIR 3 RISERS @ 150 MM 1100 13A EXISTING FLOOR W-4 DN A1-05-01 A1-02-06 PRECAST PAVERS FOR BALLAST MECHANICAL UNIT ON INTEGRAL FRAMED CURB 1-D-2 PROVIDE POSITIVE SLOPE TO EXISTING ROOF DRAIN W3 2 EXPANSION TO MECHANICAL ROOM 1115 W1 4800 OPEN TO BELOW NEW STAIR EXTENDS ABOVE EXISTING STAIR NO. 3 TO PROVIDE NEW ROOF ACCESS 1 DN 14A 85 Hanna Avenue, Suite 300 Toronto, ON Canada M6K 3S3 T 416 583 3600 F 416 583 3610 www.kasian.com W3C PRECAST PAVERS FOR BALLAST EXISTING CLUBHOUSE 6 A1-04-01 9A 02 01 8A 2014-09-15 2013-04-09 REV. Approver Approver REVIEW ISSUED FOR BUILDING PERMIT AMENDMENT ISSUED FOR BUILDING PERMIT YYYY-MM-DD REVISION / DRAWING ISSUE CLIENT 1 A1-02-01 CONSTRUCTION PLAN_SECOND FLOOR SCALE: 1 : 125 CONSULTANT 1 1 A1-06-01 A1-05-02 5 A1-04-01 A1x A1 B1x 3919 6000 C1 3000 D1 E1x E1 5500 5500 5300 F1 2000 G1 2 H1 5500 A1-02-06 12800 6 5 2 7 A1-05-01 A1-05-01 A1-05-02 A1-05-01 J1 K1 5500 L1 M1 5500 7300 N1 5500 P1 5500 Q1 7300 R1 5500 S1 5500 W4 PERMIT STAMP 14A 13A 6100 NEW ROOF STRUCTURE BELOW 1 A1-04-01 NEW ROOF STURCURE BELOW 13Ax W4 SEAL W5 1 A1-05-01 DN EXISTING CONCRETE SLAB BELOW W1 AT INFILL ONLY EXISTING WALL NEW ROOF DRAIN PAVER BALLAST PROVIDE PRECAST PAVERS FOR ROOF ACCESS ROCK BALLAST WITH PAVERS FOR ACCESS NEW DOOR PART OF LOUVER ASSEMBLY NEW ROOF DRAIN W4 W4 NEW ROOF DRAIN W5 W4 W5 A1-05-01 NEW ROOF DRAIN EXISTING CONCRETE SLAB BELOW 4800 2 NEW STRUCTURE FOR NEW COOLING TOWER UNITS REFER TO STRUCTURAL DRAWINGS W4 OPEN TO BELOW 4 A1-04-01 NEW ROOF DRAIN NEW ROOF DRAIN 12A OPEN TO BELOW 4100 3 A1-05-01 PROJECT 3 W4 2000 11Ax THIS DRAWING, AS AN INSTRUMENT OF SERVICE IS THE PROPERTY OF KASIAN ARCHITECTURE ONTARIO INC. THE COPYRIGHT IN THE SAME BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE PERMISSION OF KASIAN ARCHITECTURE ONTARIO INC. AND WHEN MADE MUST BEAR ITS NAME. THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD FOR ADJUSTMENT. REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR MECHANICAL EQUIPMENT C/W CATWALK AND ACCESS STAIR 11A A1-04-01 4 HAZELTON LANES 10Ax 6100 A1-05-01 55,77, AND 87 AVENUE ROAD. TORONTO, ONTARIO, M5R 2G3 OPEN TO BELOW 10A OPEN TO BELOW DRAWING TITLE FLOOR PLANS_2ND FLOOR ROOF AND LOWER PENTHOUSE ROOF W4 6 DRAWING ISSUE A1-04-01 B1 MECHANICAL PENTHOUSE RENOVATION PRELIMINARY, NOT FOR CONSTRUCTION 2 A1-02-01 EXIST. LOW MECH ROOM ROOF SCALE: 1 : 125 PROJECT NO. 130213 DRAWING NO. PLOT DATE SCALE 2014/09/15 1 : 125 A1-02-01 DRAWN REVIEWED Author Checker REVISION