AC Power Systems Design Guide Easy and Flexible Lithonia Lighting Emergency adds AC emergency power systems for small to medium loads to its existing line of building systems and Power Sentry luminaireEmergency Power Solutions mounted battery packs. The new EAC ISSM and FTM provide solutions for most Designed for including new construction or last minute lightingorenhancements, these sources, LED, fluorescent andemergency HID, for indoor outdoor applications. dedicated-circuit AC power units provide the power for full light output for single fixture or These systems small-sized circuits. are compatible with LC&D® emergency shunt relay dimming and switching systems as well as Sensor Switch® nLight™ relay packs, integrating • UL924 Listed to operate fixtures at full light output. Perfect of field retrofitting emergency luminaire control into luminaires that provide light output in power fordimming LED lightand fixtures, while retaining the luminaires’ ULfull listing emergency mode. • 125-watt and 375-watt models are suited for LED and Fluorescent sources for indoor or outdoor luminaires • The 350-watt unit delivers power with no interruption to the HID arch, making it ideal for outdoor and high-bay applications as well as LED and Fluorescent luminaires Compatible with LC&D® emergency shunt relay dimming and switching systems as well as Sensor Switch® nLight™ relay packs – integrating normal dimming and control into luminaires that provide full light output in emergency. www.lithonia.com/AC-PowerSystems Typical Emergency Lighting EAC ISSM Normally Off Load Connect unswitched line 120 or 277 to primary unswitched AC input. Lighting load must be connected to same voltage as unswitched line. Cap off flying leads. www.lithonia.com/AC-PowerSystems Normally On Load Connect unswitched line 120 or 277 to primary unswitched AC input and flying leads. Lighting load must be connected to same voltage as unswitched line. Wall Switched Load Connect unswitched line 120 or 277 to primary unswitched AC input and flying leads. Lighting load must be connected to same voltage as unswitched line. www.lithonia.com/AC-PowerSystems Wall Dimmer Load Connect unswitched line 120 or 277 to primary unswitched AC input and flying leads. Lighting load must be connected to same voltage as unswitched line. Switched & Unswitched Loads Connect unswitched line 120 or 277 to primary unswitched AC input and flying leads. Lighting load must be connected to same voltage as unswitched line. www.lithonia.com/AC-PowerSystems Wall Dimmer & Unswitched Load Connect unswitched line 120 or 277 to primary unswitched AC input and flying leads. Lighting load must be connected to same voltage as unswitched line. 3-Way Wall Switched Load Connect unswitched line 120 or 277 to primary unswitched AC input and flying leads. Lighting load must be connected to same voltage as unswitched line. www.lithonia.com/AC-PowerSystems nLight Controlled Loads Connect unswitched line 120 or 277 to primary unswitched AC input and flying leads. Lighting load must be connected to same voltage as unswitched line. Typical Emergency Lighting EAC FTM www.lithonia.com/AC-PowerSystems Normally On Loads Connect unswitched line 120 or 277 to primary unswitched AC input and flying leads. Lighting load must be connected to same voltage as unswitched line. Switched & Unswitched Loads Connect unswitched line 120 or 277 to primary unswitched AC input and flying leads. Lighting load must be connected to same voltage as unswitched line. The switched emergency lighting load is not suitable for use with HID fixtures. www.lithonia.com/AC-PowerSystems Wall Dimmer & Unswitched Loads Connect unswitched line 120 or 277 to primary unswitched AC input and flying leads. Lighting load must be connected to same voltage as unswitched line.The dimmed emergency lighting load is not suitable for use with HID fixtures. 3-Way Wall Switched Load 3-WAY WALL SWITCHED LOAD Connect unswitchedline line 120 120 or unswitched AC input and flying leads. Lighting load Connect unswitched or277 277totoprimary primary unswitched AC input and flying must be connected to same voltage as unswitched line. leads. Lighting loadmust connectedisto voltage unswitched line. This Thisbe configuration notsame suitable for useaswith HID fixtures. configuration is not suitable for use with HID fixtures. EAC FTM OR (277V) Unswitched Line 120 or 277 BK (120V) Neutral WT (NEU) Primary Unswitched AC Input OR (277V) Output Lead AC Input BK (120V) WT (NEU) Emergency Shunt Relay www.lithonia.com/AC-PowerSystems Load Hot 120 or 277 Load (NEU) Switched Emergency Lighting Load 120 or 277 nLight Controlled Loads Connect unswitched line 120 or 277 to primary unswitched AC input and flying leads. Lighting load must be connected to same voltage as unswitched line. Low-watt AC Power System Luminaire Application Examples Luminaire Application Examples EAC ISSM 125 120/277 EAC ISSM 375 120/277 EAC FTM 350 120-MV Recessed Grid Ceiling Mount (RGM), Surface Mount (SM) or Recessed Wall Mount (RWM) Surface Mount (SM) Only Surface Mount (SM) Only* SM SM RGM SM RWM Linear Fluorescent LED Linear Fluorescent LED Linear Fluorescent LED Compact Fluorescent LED Compact Fluorescent LED HID Compact Fluorescent LED Linear Fluorescent Compact Fluorescent LED Linear Fluorescent Compact Fluorescent LED HID Linear Fluorescent Compact Fluorescent LED Compact Fluorescent LED Compact Fluorescent LED HID Compact Fluorescent LED Examples of Acuity Brands products shown. Lithonia Lighting Low-watt AC Power Systems are applicable to most fluorescent, compact fluorescent, HID and LED luminaires. * Available with single-input 120V with 120, 208, 240 or 277V output ©2011 Acuity Brands Lighting, Inc. All rights reserved. | ES7376 | Form No. 680.231 | 04/12 One Lithonia Way | Conyers, GA 30012 | 800.334.8694