RHB1402 1-888-474-7395 www.RHBinnovations.com SERIES D PARALLEL OPERATION Emergency Lighting Equipment INSTRUCTION MANUAL IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. CAUTION – To prevent electrical shock, do not mate unit connector until installation is complete and A.C. power is supplied to the unit. 2. CAUTION – This fixture provides more than one power supply output source. To reduce the risk of electrical shock, disconnect both normal and emergency sources by turning off the A.C. branch circuit and by disconnecting the unit connector. 3. CAUTION – This is a sealed unit. The integral, high temperature Ni-Cad battery is not replaceable. Replace the entire unit when necessary and recycle or dispose of the nickel-cadmium battery properly. 4. DO NOT USE OUTDOORS. The RHB1402 is for use with grounded, UL Listed, damp location rated, indoor fixtures. Not for use in heated air outlets or hazardous locations. 5. The RHB1402 requires an unswitched A.C. power source of either 120 or 277 volts. Properly cap the unused A.C. lead. 6. The RHB1402 and A.C. ballast must be on the same branch circuit. 7. Do not mount near gas or electric heaters. 8. The RHB1402 should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. 9. The RHB1402 is suitable for mounting in the ballast compartment or on top of the fixture. For top mount, order optional mounting kit TMK-80. The RHB1402 requires two (2) TMK-80s; one for each end of the unit. When used in conjunction with enclosed and gasketed fixtures, the RHB1402 is suitable for mounting in the ballast compartment only. 10. The RHB1402 will cold strike and operate two 4′ instant start, rapid start, U shape or circline, T8 through T12 fluorescent lamps. 11. The RHB1402 operates lamps at reduced output as follows: two 4′ lamps for 90 minutes. The RHB1402 is compatible with all A.C. ballasts (including multiple lamps). 12. Suitable for use in damp locations and in enclosed and gasketed fixtures. 13. For use in 0° C minimum, 50° C maximum ambient temperatures. 14. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. 15. Do not use this equipment for other than intended use. 16. Install in accordance with the National Electrical Code and local regulations. 17. Installation and servicing should be performed by qualified personnel. 18. Lighting fixture manufacturers, electricians and end users need to ensure product system compatibility before final installation. SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS CAUTION: Before installing, make certain the A.C. power is off and the RHB1402 unit connector is disconnected. 1. MOUNTING THE RHB1402 Remove the ballast channel cover. For heat consideration, mount the RHB1402 in the ballast channel as far away from the A.C. ballast(s) as possible. The RHB1402 may also be mounted on top of the fixture. The optional top mounting kit (catalog no. TMK-80) may be ordered separately from Customer Service. When battery packs are remote mounted, consult Customer Service for the maximum allowable distance between the battery pack and lamps. 2.WIRING Refer to the wiring diagrams on the back page for the appropriate wiring of lamps and ballast. Install in accordance with the National Electrical Code and local regulations. For additional wiring diagrams consult Customer Service. 3. INSTALLING THE CHARGE INDICATOR Recessed Troffer Fixture – Select a convenient location with proper clearance in the ballast cover and drill or punch a 7/8″ hole (½″ knockout). Insert the 7/8″ bushing into the hole. Push the plastic tube through the bushing. Disconnect the leads from the LED housing and route the leads down the plastic tube. Reconnect the leads to the housing, observing the proper polarity (Red/Black or Red lead w/connector to positive (+) red tab). Push the entire assembly back into the tube until the lens collar rests against the plastic tube. The plastic tube should be adjusted so that the Charge Indicator is within ¼″ of the fixture lens. The Charge Indicator must be visible after installation. Refer to Illustration 1. Strip Fixture – Select a convenient location on the side of the fixture so the Charge Indicator can be seen after installation. Allow for proper clearance inside the fixture and drill or punch a 1/2″ hole. Disconnect the leads from the LED housing. Push the LED housing into the ½″ hole until it is firmly locked in place. Reconnect the leads, Illustration 1 Recessed Troffer Fixture Illustration 2 Strip Fixture FIXTURE BALLAST CHANNEL COVER RHB1402 RHB1402 WHITE/RED LEAD PLASTIC TUBE 7/8" BUSHING CHARGE INDICATOR LIGHT +R ED FIXTURE CHARGE INDICATOR LIGHT FIXTURE LENS (POS LEAD) RED/BLK OR RED W/CONNECTOR OBSERVE PROPER POLARITY observing the proper polarity (Red/Black or Red lead w/connector positive (+) red tab). Refer to Illustration 2. 4. INSTALLING THE TEST SWITCH The Test Switch should be mounted on the ballast channel cover of a recessed troffer, or on the side of a strip fixture, preferably adjacent to the Charge Indicator. Drill or punch a 1/2″ mounting hole. Page 2 5. WIRING THE A.C. INPUT A.The RHB1402 and A.C. ballast must be on the same branch circuit. B.The RHB1402 requires an unswitched A.C. power source of either 120 or 277 volts. Select the proper voltage lead and cap the unused lead. C. When the RHB1402 is used with a switched fixture, the A.C. input to the RHB1402 must be connected ahead of the fixture switch. Refer to Illustration 3 for switched and unswitched fixture wiring diagrams. Illustration 3 Switched Fixture Unswitched Fixture WHITE BLACK WHITE A.C. BALLAST BLACK BLK/ORG BLK/ORG WHITE COMMON (277V) ORG ➀ TEST SWITCH (120V) BLK WHITE COMMON (277V) ORG RHB 1402 BLK/ORG HOT A.C. LINE A.C. BALLAST ➀ TEST SWITCH HOT A.C. LINE WALL SWITCH (120V) BLK RHB 1402 BLK/ORG ➀ Select proper voltage lead. Cap unused lead. ➀ Select proper voltage lead. Cap unused lead. 6.LABELS Attach the appropriate labels adjacent to the Test Switch and Charge Indicator. Annotate Re-lamping label for lamp type and wattage. The Caution and the Re-lamping labels must be on the fixture in a readily visible location to anyone attempting to service the fixture. 7. COMPLETING INSTALLATION When the installation is complete, switch the A.C. power on and join the RHB1402 unit connector. OPERATION Normal Mode – A.C. power is present. The A.C. ballast operates the fluorescent lamp(s) as intended. The RHB1402 is in the standby charging mode. The Charge Indicator will be lit providing a visual indication that the battery is being charged. Emergency Mode – The A.C. power fails. The RHB1402 senses the A.C. power failure and automatically switches to the Emergency Mode. Two lamps are illuminated, at reduced output, for a minimum of 90 minutes. When the A.C. power is restored, the RHB1402 switches the system back to the Normal Mode and resumes battery charging. See page 1 of the Instruction Manual. TESTING & MAINTENANCE Initial Testing – Allow the unit to charge approximately 1 hour, then conduct a short discharge test. Allow a 24 hour charge before conducting a one hour test. The RHB1402 is a maintenance free unit, however, periodic inspection and testing is required. NFPA 101, Life Safety Code, outlines the following schedule: Monthly – Insure that the Charge Indicator light is illuminated. Conduct a 30 second discharge test by depressing the Test Switch. Two lamps should operate at reduced output. Annually – Insure that the Charge Indicator light is illuminated. Conduct a full 11/2 hour discharge test. The unit should operate as intended for the duration of the test. “Written records of testing shall be kept by the owner for inspection by the authority having jurisdiction.” SERVICING SHOULD BE PERFORMED BY QUALIFIED PERSONNEL. Consult Customer Service for current warranty information. Page 3 TYPICAL WIRING DIAGRAMS For wiring diagrams of ballasts not shown, consult our Customer Service. TWO LAMP RAPID START BALLAST Select proper voltage lead. Cap unused lead BLACK WHITE A.C. BALLAST Do not mate connector until installation is complete and A.C. power is supplied. Test accessory leads - refer to installation instructions for proper polarity wiring. No polarity on BLK/ORG leads. Switched or unswitched line - refer to installation manual for hot and test switch placement BLUE BLUE BLUE BLUE/WHT RED VIOLET RED VIO/WHT BRN YELLOW YELLOW RED RED/WHT YELLOW LAMP* * OPERATES IN A.C. AND CONNECTOR PROPER VOLTAGE ➀ SELECT LEAD. CAP UNUSED LEADS. WHITE COMMON ORG (277V) ➀ UNSWITCHED LINE BLK (120V) ➁ EMERGENCY MODE. ➃ OR ➃ SWITCHED UNSWITCHED ➄ LINE RHB 1402 BRN/WHT LAMP* BLK/ORG BLK/ORG RED OR RED/BLK (+) * Operates in A.C. and emergency mode. EMERGENCY BALLAST WHT/RED 1. TWO LAMP RAPID START BALLAST ➂ NOT MATE CONNECTOR UNTIL ➁ DO INSTALLATION IS COMPLETE CHARGE INDICATOR AND A.C. POWER IS SUPPLIED. A.C. BALLAST Do not mate connector until installation is complete and A.C. power is supplied. No polarity on BLK/ORG leads. Switched or unswitched line - refer to installation manual for hot and test switch placement BLUE RED BLUE/WHT BLK/ORG VIOLET VIO/WHT BLUE/WHT BLUE LAMP BLUE YELLOW RHB 1402 BRN BRN/WHT LAMP* YELLOW RED RED/WHT LAMP* * Operates in A.C. and emergency mode. ➁ * OPERATES IN A.C. AND EMERGENCY MODE. CONNECTOR PROPER VOLTAGE ➀ SELECT LEAD. CAP UNUSED LEADS. manual for hot and test switch placement ➀ UNSWITCHED LINE ORG (277V) BLK (120V) ➂ ACCESSORY LEADS - REFER ➂ TEST TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY LEAD WIRING. ➃ NO POLARITY ON BLK/ORG LEADS. OR UNSWITCHED LINE➄ SWITCHED A.C.TO INSTALLATION MANUAL REFER BLUE BLUE BLACK VIOLET BLUE WHITE BALLAST RED FOR HOT AND TEST SWITCH PLACEMENT. BLK/ORG BLUE/WHT ➂ ➂ RED/WHT VIO/WHT BRN RED LAMP* YELLOW ➁ * OPERATES IN A.C. AND EMERGENCY MODE. BLK/ORG RHB 1402 BRN/WHT LAMP* Pigtail leads together No polarity on BLK/ORG leads. Switched or unswitched line - refer to installation ➄ COMMON 2LRSB_232_D TWO LAMP INSTANT START BALLAST AND A.C. POWER IS SUPPLIED. is complete and A.C. power is supplied. Test accessory leads - refer to installation instructions for proper polarity wiring. SWITCHED OR UNSWITCHED LINE WHITE CHARGE INDICATOR EMERGENCY BALLAST Select proper voltage lead. Cap unused lead Do not mate connector until installation ➃ ➃ YELLOW NOT MATE CONNECTOR UNTIL ➁ DO INSTALLATION IS COMPLETE 3. TWO LAMP INSTANT START BALLAST BLK/ORG RED OR RED/BLK (+) Test accessory leads - refer to installation instructions for proper polarity wiring. RED WHT/RED Select proper voltage lead. Cap unused lead BLACK WHITEHOT AND TESTBLUE/WHT FOR SWITCH PLACEMENT. CONNECTOR PROPER VOLTAGE ➀ SELECT LEAD. CAP UNUSED LEADS. WHT/RED * Operates in A.C. and emergency mode. EMERGENCY BALLAST FOR PROPER POLARITY LEAD WIRING. ➃ NO POLARITY ON BLK/ORG LEADS. OR UNSWITCHED LINE➄ SWITCHED REFER TO INSTALLATION MANUAL ➄ ➄ SWITCHED OR UNSWITCHED LINE ➅ WHITE COMMON ORG (277V) ➀ UNSWITCHED 3LRSB_232_D LINE BLK (120V) RED OR RED/BLK (+) 2. THREE LAMP RAPID START BALLAST LAMP RAPID START BALLAST TEST ACCESSORY LEADS - REFER ➂THREE TO INSTALLATION INSTRUCTIONS ➃ NOT MATE CONNECTOR UNTIL ➁ DO INSTALLATION IS COMPLETE CHARGE INDICATOR AND A.C. POWER IS SUPPLIED. THREE LAMP INSTANT START BALLAST 4. THREE LAMP INSTANT START BALLAST ➂ PIGTAIL LEADS TOGETHER. ACCESSORY LEADS - REFER ➃ TEST TO INSTALLATION INSTRUCTIONS ➄ NO POLARITY ON BLK/ORG LEADS. ➅ SWITCHED A.C.OR UNSWITCHED LINEREFER TO INSTALLATION MANUAL BLUE VIOLET BLUE BLUE/WHT FOR HOT AND TEST SWITCH PLACEMENT. Test accessory leads - refer to installation instructions for proper polarity wiring. No polarity on BLK/ORG leads. Switched or unswitched line - refer to installation manual for hot and test switch placement LAMP ➂ RED/WHT BRN/WHT VIO/WHT BRN LAMP* RED LAMP* * OPERATES IN A.C. AND BLK/ORG RHB 1402 BLK/ORG ➄ ➄ SWITCHED OR UNSWITCHED LINE ➅ WHITE COMMON ORG (277V) BLK (120V) ➀ 2LISB_232_D UNSWITCHED LINE YELLOW EMERGENCY MODE. ➁ CONNECTOR PROPER VOLTAGE ➀ SELECT LEAD. CAP UNUSED LEADS. RED OR RED/BLK (+) BALLAST ➂ RED is complete and A.C. power is supplied. Pigtail leads together BLUE BLUE WHITE EMERGENCY BALLAST Select proper voltage lead. Cap unused lead Do not mate connector until installation FOR PROPER POLARITY LEAD WIRING. BLACK WHT/RED * Operates in A.C. and emergency mode. ➃ NOT MATE CONNECTOR UNTIL ➁ DO INSTALLATION IS COMPLETE CHARGE INDICATOR AND A.C. POWER IS SUPPLIED. ➂ LAMP INSTANT START BALLAST FOUR PIGTAIL LEADS TOGETHER. * Operates in A.C. and emergency mode. is complete and A.C. power is supplied. WHITE FOR HOT AND TEST REDSWITCH PLACEMENT. A.C. BALLAST YELLOW YELLOW Pigtail leads together Test accessory leads - refer to installation instructions for proper polarity wiring. No polarity on BLK/ORG leads. Switched or unswitched line - refer to installation manual for hot and test switch placement LAMP LAMP LAMP* * OPERATES IN A.C. AND EMERGENCY MODE. PROPER VOLTAGE ➀ SELECT LEAD. CAP UNUSED LEADS. NOT MATE CONNECTOR UNTIL ➁ DO INSTALLATION IS COMPLETE Page 4 TOGETHER. ➂ PIGTAIL LEADS TEST ACCESSORY LEADS - REFER ➃ TO INSTALLATION INSTRUCTIONS FOR PROPER POLARITY LEAD WIRING. BLK/ORG VIOLET LAMP* AND A.C. POWER IS SUPPLIED. Rev. 071513 68232-012 BLUE BLUE BLUE RED ➂ ➂ BLUE/WHT RED/WHT BRN/WHT VIO/WHT BRN RED EMERGENCY BALLAST Select proper voltage lead. Cap unused lead Do not mate connector until installation BLACK RHB 1402 YELLOW ➁ CONNECTOR BLK/ORG ➄ ➄ SWITCHED OR UNSWITCHED LINE ORG (277V) BLK (120V) ➃ CHARGE INDICATOR ➅ 3LISB_232_D COMMON WHITE RED OR RED/BLK (+) FOR PROPER POLARITY LEAD WIRING. ➄ NO POLARITY ON BLK/ORG LEADS. OR UNSWITCHED LINE➅ SWITCHED REFER TO INSTALLATION MANUAL WHT/RED 5. FOUR LAMP INSTANT START BALLAST ACCESSORY LEADS - REFER ➃ TEST TO INSTALLATION INSTRUCTIONS ➀ UNSWITCHED LINE