Prospex® 140 Wallwash Downlight 140-XIC‐WW Lensed Wallwash with specular darklight reflctor and frosted linear spread lens as standard. Low glare 40° visual cut off. IP54 versions available. Ref Number: Specular reflector, white trim 140-XIC-WW‐PS-WH 140-XSM-WW‐SS-WH Stain silver reflector, white trim White reflector, white trim 140-XSM-WW‐WH-WH Black reflector, white trim 140-XSM-WW‐BK-WH 140-XSM-WW‐CG-WH Champagne gold reflector, white trim Lamp quantity 1 Module Type max output max wattage max driver max depth X XTM 5000lm 46.8w 1400mA 201mm XTA 3000lm 34.1w 1050mA 201mm XTV83 5000lm 46.8w 1400mA 201mm XTV98 3000lm 34.1w 1050mA 201mm Module Type max output max wattage max driver max depth X XTM9 2000lm 30.2w 1050mA 176mm XTA9 2000lm 42.1w 1400mA 201mm XTV983 2000lm 30.2w 1050mA 176mm XTV998 2000lm 42.1w 1400mA 201mm max. depth is based on max lumen output with the deepest reflector @ ambient temperature 35°C. other combinations may vary www.lucent-lighting.com Adjustable Aperture Overall dimension Overall height Required depth First fix requirement* Ceiling cut out Ceiling thickness Ingress protection** Dimming options*** No 108mm Ø 140mm Ø 185mm (passive) X + MIN 25mm No 128mm Ø 25mm MAX IP20 Phase/DALI/1-10v Cut out 128mmØ Adjust the depth by the following for different lumen output modules. Module Type 4000lm 3000lm 2000lm 1300lm Module Type 1300lm 700lm XTM/XTV83 XTA/XTV98 Depth - 0mm Depth -26mm Depth -26mm Depth -26mm Depth - 52mm Depth - 52mm XTM9 XTA9 Depth - 27mm Depth -26mm Depth - 27mm Depth - 52mm Module output always at the maximum drive current. *First Fix requirement. No first fix requirement, please refer to Lucent Installation Instructions **IP Rating. Tested from underside of the ceiling. ***Dimming. Whilst Lucent can offer the majority of its luminaires with various dimming options, it the responsibility to check and ensure compatibility of any control *remains Separate die cast plasterofinthe kit specifier/installer for plaster ceilings. equipment used. Additional cabling be required depending on of thecode. dimming protocol specified. ** Tested from ceiling underside. Tomay specify IP54; add '-IP' to end *** Dimming options depend on driver (toimprove be separately policy of Lucent Lighting to continually review and its products ordered/specified). and therefore reserve the right to change any details of product or It is the withdraw specifications prior notice. Some controlwithout methods may require additional cabling Luminaires designed to comply with EN60598 and all other relevant Standards. This Specification Sheet supersedes all previous versions All intellectual property rights pertaining to the product described above and to this document are owned or licensed Lucent Lighting UK Lucent reserve the right to change any details, dimensions colours etc without priorbynotice. Anyto reproduction of Ltd. We reserve our right to take whatever action is necessary to protect those intellectual property rights. Lucent products is strictly forbidden .. perpetrators will be pursued! Information correct as of May 2012. Please notify Lucent Lighting Ltd of any inaccuracies immediately. E&OE Job/Project Name Area/Location Contact Lucent Lighting: e: info@lucent-lighting.com t: +44 (0)20 8442 0880 Europe Fitting Ref China Quantity Russia Lucent Xicato LED Modules with 70mmØ Reflectors Module Code Builder. Lumen outputs shaded in gray are available with passive heatsink for use with this luminaire type. Higher lumen outputs may be available with active cooling. Please consult Lucent Lighting for details. XTM XTA XTV XTM9 XTA9 XTV9 www.lucent-lighting.com 5000lm 4000lm 3000lm 2000lm CRI 83 83 83 83 83 98 98 98 83 98 83 98 83 98 83 83 83 83 83 98 98 98 83 98 83 98 83 98 1300lm Type Lumen output at maximum drive current. 700lm Module Colour temp (K) 27/30/35/40 27/30/35/40 27/30/35/40 27/30/35/40 27/30/35/40 27/30/35/40 27/30/35/40 27/30/35/40 30 30 30 30 30 30 30 30 27/30/35/40 27/30/35/40 27/30/35/40 27/30/35/40 27/30/35/40 27/30/35/40 30 30 30 30 30 30 Reflector (70Ø) Beam angle (°) 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 41 41 41 41 41 41 41 41 41 41 41 41 Max. Drive Wattage Current (mA) 700mA 700mA 1050mA 1400mA 1400mA 700mA 1050mA 1050mA 700mA 700mA 1050mA 1050mA 1050mA 1050mA 1400mA 1400mA 700mA 700mA 1050mA 700mA 1050mA 1400mA 700mA 700mA 700mA 1050mA 1050mA 1400mA (W) 11.7 19.5 29.3 39.1 46.8 15.6 26.4 34.1 11.7 15.6 19.5 26.4 29.3 34.1 39.1 46.8 7.8 15.6 30.2 9.7 24.3 42.1 7.8 9.7 15.6 24.3 30.2 42.1 7 Xictao Module Type Required. Lumen Output. (Refer to luminaire speification sheet for maximum permitted output) Colour temperature required * Separate die cast plaster in kit for plaster ceilings. ** Tested from ceiling underside. To specify IP54; add '-IP' to end of code. *** Dimming options depend on driver (toimprove be separately policy of Lucent Lighting to continually review and its products ordered/specified). and therefore reserve the right to change any details of product or It is the withdraw specifications prior notice. Some controlwithout methods may require additional cabling Diameter of reflector (70mm) Beam angle required. Luminaires designed to comply with EN60598 and all other relevant Standards. This Specification Sheet supersedes all previous versions All intellectual property rights pertaining to the product described above and to this document are owned or licensed to Lucent Lighting UK Ltd. Lucent reserve the right to change any details, dimensions colours etc without priorbynotice. We reserve our right to take whatever action is necessary to protect those intellectual property rights. Please notify Lucent Lighting Ltd of any inaccuracies immediately. E&OE Job/Project Name Area/Location Contact Lucent Lighting: e: info@lucent-lighting.com t: +44 (0)20 8442 0880 Fitting Ref Quantity Lucent Xicato LED Modules with 70mmØ Reflectors Module Code Builder. Indicates modules available in the range. Refer to the luminaire specification for maximum modules permitted. XTB 5000lm 4000lm 3000lm 2000lm CRI 95 95 1300lm Type Lumen output at maximum drive current. 700lm Module Colour Reflector (70Ø) Max. Drive Wattage temp (K) 27 27 Beam angle (°) Current (mA) 700mA 1050mA (W) 15.6 26.4 23/42/57 23/42/57 7 Xictao Module Type Required. Lumen Output. (Refer to luminaire speification sheet for maximum permitted output) Diameter of reflector (70mm) Colour temperature required Beam angle required. www.lucent-lighting.com * Separate die cast plaster in kit for plaster ceilings. ** Tested from ceiling underside. To specify IP54; add '-IP' to end of code. *** Dimming options depend on driver (toimprove be separately policy of Lucent Lighting to continually review and its products ordered/specified). and therefore reserve the right to change any details of product or It is the withdraw specifications prior notice. Some controlwithout methods may require additional cabling Luminaires designed to comply with EN60598 and all other relevant Standards. This Specification Sheet supersedes all previous versions All intellectual property rights pertaining to the product described above and to this document are owned or licensed to Lucent Lighting UK Ltd. Lucent reserve the right to change any details, dimensions colours etc without priorbynotice. We reserve our right to take whatever action is necessary to protect those intellectual property rights. Please notify Lucent Lighting Ltd of any inaccuracies immediately. E&OE Job/Project Name Area/Location Contact Lucent Lighting: e: info@lucent-lighting.com t: +44 (0)20 8442 0880 Fitting Ref Quantity