1689 version 4 Page 1 of 3 Fix full concrete roof tiles Level 4 Credits 8 Purpose People credited with this unit are able to: lay out concrete roof tiles; fix full concrete roof tiles; and maintain a safe working environment. Subfield Plumbing, Gasfitting and Drainlaying Domain Roofing Status Registered Status date 27 October 2006 Date version published 22 August 2008 Planned review date 30 April 2013 Entry information Open. Accreditation Evaluation of documentation and visit by NZQA and industry. Standard setting body (SSB) The Skills Organisation Accreditation and Moderation Action Plan (AMAP) reference 0227 This AMAP can be accessed at http://www.nzqa.govt.nz/framework/search/index.do. Special notes 1 Legislation relevant to this unit standard includes but is not limited to the Health and Safety in Employment Act 1992, and the Building Act 2004. 2 Performance must comply with current legislation, regulations, and codes. For more detailed information about which regulations and codes are relevant, please refer to the assessors’ page of The Skills Organisation Ltd website http://www.skills.org.nz. New Zealand Standard (NZS) 4206:1992 Concrete interlocking roofing tiles which is within this unit standard is available from http://www.standards.co.nz. 3 Definitions Company requirements include the policy, procedures, and methodologies of the company. They include requirements documented in company and site health and safety plans, quality assurance documents, and contract work programmes; Site procedures refer to the procedures which are required to be observed for safe work practices at a particular site; New Zealand Qualifications Authority 2016 1689 version 4 Page 2 of 3 Job specifications refer to the documented information found in construction drawings, project specification documents, legislation, regulations, and codes; Manufacturers’ recommendations refer to product information and product data sheets provided by the manufacturer of any given product. 4 This unit standard applies to both new roof and re-roofing installations. Elements and performance criteria Element 1 Lay out concrete roof tiles. Performance criteria 1.1 Laid tiles conform to the requirements of the job specifications and NZS 4206:1992. 1.2 Tile parts or manufacturing scrap are removed to enable tiles to sit to line on finished roof in accordance with company requirements. 1.3 Laid tiles interlock as designed and vertical and diagonal alignment is maintained in accordance with tile manufacturer’s recommendations and company requirements. Element 2 Fix full concrete roof tiles. Performance criteria 2.1 Fixing system and fixing pattern adopted conform with the requirements of NZS 4206:1992 and the job specification where this exceeds the standard. 2.2 Application of specified fixing is in accordance with the requirements of NZS 4206:1992. 2.3 Tiles damaged and not meeting manufacturer’s recommendations during roofing work are replaced in accordance with company requirements. 2.4 Rejected tiles and unusable tile sections are removed from the roof in accordance with site procedures. 2.5 Surplus material is removed, and roof and site are left in a condition which enables further work to be carried out, in accordance with company requirements. Element 3 Maintain a safe working environment. Performance criteria New Zealand Qualifications Authority 2016 1689 version 4 Page 3 of 3 3.1 Work practices are carried out without injury to people or damage to equipment, building, or plant, in accordance with legislation, regulations, codes, health and safety in employment guidelines, and company requirements. 3.2 Personal protective equipment for the task at hand is selected and worn in accordance with manufacturers’ recommendations and site procedures. Range includes but is not limited to – hard hat, sunblock, ear muffs, safety glasses, gloves, knee pads, high visibility clothing, safety harness. 3.3 Work area is cordoned off and safety notices and notification of work signs are distributed and erected, in accordance with site procedures. 3.4 Work area is kept clear of debris and unnecessary items in accordance with site procedures. Please note Providers must be accredited by the Qualifications Authority, or an inter-institutional body with delegated authority for quality assurance, before they can report credits from assessment against unit standards or deliver courses of study leading to that assessment. Industry Training Organisations must be accredited by the Qualifications Authority before they can register credits from assessment against unit standards. Accredited providers and Industry Training Organisations assessing against unit standards must engage with the moderation system that applies to those standards. Accreditation requirements and an outline of the moderation system that applies to this standard are outlined in the Accreditation and Moderation Action Plan (AMAP). The AMAP also includes useful information about special requirements for organisations wishing to develop education and training programmes, such as minimum qualifications for tutors and assessors, and special resource requirements. Comments on this unit standard Please contact The Skills Organisation info@skills.org.nz if you wish to suggest changes to the content of this unit standard. New Zealand Qualifications Authority 2016