IAQ Check List Building: Lake Zurich Middle School North Date: November 8, 2013 Building Inspection Performed by: Lyle Erstad Report Compiled by: Lyle Erstad Check List IAQ Check List True False N/A 1. Ground Level Indoor Inspection a. Univents are on and air discharge grills are free of obstructions. If false, send email to building principal and facilities director asking staff to be instructed to keep vents clear at all times. Record locations here: 2. Ground Level Outdoor Inspection (weather permitting) a. Univent air intakes are free of obstructions. If false, record locations here: b. Filters i. Medium efficiency filters are installed in all univents. If false, list locations and create work orders to initiate corrective action. ii. High efficiency filters are installed in the air handling units. If false, list locations and create work orders to initiate correction action. iii. Filters are being changed every six months and the installed date is written on the outer filter casing. If filter is older than 6 months, list locations and create work orders to initiate corrective action. c. Insects, bird nests, or droppings are not evident near outdoor air intakes. If false, indicate locations here: d. Trash dumpsters are located away from doors, windows, and outdoor air intakes. e. Potential sources of air contaminants do not exist near the building. (e.g. chimneys, stacks, industrial plants, exhaust from nearby buildings) f. Trucks and buses are not allowed to keep their engines idling near the building. Page 1 of 9 Revised 3/21/2011 AMJ Created 11/2010 IAQ Check List Building: Lake Zurich Middle School North Date: November 8, 2013 Building Inspection Performed by: Lyle Erstad Report Compiled by: Lyle Erstad Check List g. No evidence of drainage problems exist. Water drains away from the building including roof downspouts. IAQ Check List True False N/A h. Sprinklers do not spray directly toward the building or into outdoor air intakes. i. Grass clippings from mowers are directed away from the building air intakes. j. Clean walk-off mats are present at exterior entrances. 3. Roof (Inspections conducted weather permitting) a. Roofing consultant has not found any issues requiring immediate repair. Most recent roofing inspection date/company: 5-year roofing plan completed 5/25/2010 with C. E. Crowley & Associates. This past summer Riddiford Roofing did a complete inspection of all District roofs and made repairs accordingly. For issues that come up over the year, All American Exteriors handles those repairs. b. There is no evidence of water ponding on the roof. This is a ballasted roof. No signs of ponding were evident. c. Intake ventilation units are operating properly and free of debris. d. All exhaust fans are operating properly and free of debris. e. Air intake dampers are set to allow air flow even at minimum setting. f. Insects, birds, animal nests or droppings are not evident near outdoor air intakes. g. Plumbing stacks and exhaust vents are located away from air intakes. Flue stacks were raised with velocity cones installed. There have been no issues reported. 4. Attic a. There is no evidence of roof or plumbing leaks. Page 2 of 9 Revised 3/21/2011 AMJ Created 11/2010 IAQ Check List Building: Lake Zurich Middle School North Date: November 8, 2013 Building Inspection Performed by: Lyle Erstad Report Compiled by: Lyle Erstad Check List IAQ Check List True False N/A b. There is no evidence in attic of insects, birds, animals, or nests. No Attic. 5. General Considerations a. Classrooms, offices and/or common areas appear recently cleaned. If examples of poor housekeeping are found, record locations below: b. Only vacuums with HEPA filters are being used. c. All supply and exhaust ventilation units are working properly. d. Occupied space temperatures and relative humidity levels are within the standards listed below. i. Temperature range: Winter temperatures 70-73 degrees. Summer temperatures 74-80 in air-conditioned spaces and 74-85 in non-air-conditioned spaces. Outdoor air temperature: 52.4; 45.1; 60.5; 50.8 degrees. Highest temperature – Location: A114; B211; A114; A107; Reading of 74.5; 72.9; 71.6; 71.4 degrees. Lowest temperature – Location: Nurse; Gym W; Staff Lounge; A206 ; Reading of 69.4; 69.6; 66.8; 68 degrees. ii. Relative humidity range is 30% to 60%. Non-air-conditioned spaces may be higher on rainy or humid summer humid days. All spaces may be less than 30% when the out-door air temperature is less than 32 degrees. Outdoor relative humidity: 22.1; 59.8; 84; 78.4% Highest relative humidity – Location: A114; D100; Staff Lounge; A206 ; Reading of 34.8; 37.5; Page 3 of 9 Revised 3/21/2011 AMJ Created 11/2010 IAQ Check List Building: Lake Zurich Middle School North Date: November 8, 2013 Building Inspection Performed by: Lyle Erstad Report Compiled by: Lyle Erstad Check List IAQ Check List True False N/A 75; 62.8% Lowest relative humidity – Location: B118, Vastine; Library; A213; A114 ;Reading of 21.9; 32.6; 53.6; 46.2 % Readings not within acceptable standards will result in the creation of a work order, requesting maintenance to address. (Readings are noted on the attached test data sheet) e. Occupied space readings of carbon monoxide (CO) levels are less than 9.0 PPM. Outdoor Air CO Reading: 0.7; 0; 0; 0 Highest CO Location: All Rooms Reading: 0 Lowest CO Location: All Rooms Reading: 0 If the CO level is greater than 9.0 PPM in any space as measured with a handheld device or “leave-in” monitor, the space must be cleared of all occupants and steps taken to correct the problem. The issue will be immediately addressed by maintenance and the Fire Department. (Readings are noted on the attached test data sheet) f. CO2 levels in any occupied space are below threshold limits. i. Perform CO2 check with Gray Wolf or other portable device. Measure four times yearly or more often if needed. Measure only in fully occupied rooms. Reading should be less than 700 PPM plus outside air CO2 PPM. 700 PPM + 430; 410; 379; 742 PPM = 1130; 1110; 1079; 1442 PPM Assume outside CO2 is 350 if temperature is below 41 degrees and air is not stagnant with no- wind. Record all occupied space CO2 levels on forms provided. Provide the outdoor CO2 level as well as the high and low CO2 extremes below: Outdoor reading: 430; 410; 379; 742 PPM Highest CO2 reading – Location: A114; Gym W; A114; A107 ; Reading of 2900; 1092; 1799; 1006 PPM Page 4 of 9 Revised 3/21/2011 AMJ Created 11/2010 IAQ Check List Building: Lake Zurich Middle School North Date: November 8, 2013 Building Inspection Performed by: Lyle Erstad Report Compiled by: Lyle Erstad Check List Lowest CO2 reading – Location: Jakowitsch; Gym; Principal; A202 ; Reading of 491; 462; 539; 624 PPM IAQ Check List True False N/A ii. If reading is above threshold, check univent and air handling dampers to ensure a value is set to provide at least 15 cfm of fresh air intake per student based on average space occupancies. If reading is consistently elevated, then use data logging to monitor CO2 concentrations over time and look for other sources of problems. iii. CO2 levels were checked three months ago. iv. CO2 levels on “leave-in” devices, where present, where checked. No Leave In devices g. Offensive odors are not apparent. If false, list problem areas: Kitchen - pilot light had gone out on stove. It was re-lit. h. Water damage is not evident. Check for roof leaks, pipe leaks, spills, stained ceiling tiles, etc, visually and with moisture meter. Look for the source of any water leaks and schedule repairs. Discard porous items such as ceiling tiles if wet for more than 24 hours. For carpeting, if less than 9 square feet of wet area, shampoo with germicide and fan dry. For areas greater than 9 square feet, replace carpet with tile in reasonable timeframe. If carpet is over ACM tile, replace during next unoccupied break time (winter break, spring break, summer). If false, record findings and locations here: i. Mold or mildew growth is not evident. Page 5 of 9 Revised 3/21/2011 AMJ Created 11/2010 IAQ Check List Building: Lake Zurich Middle School North Date: November 8, 2013 Building Inspection Performed by: Lyle Erstad Report Compiled by: Lyle Erstad Check List j. IAQ Check List True False N/A If false, record findings and locations here: All pest management issues are being handled by Integrated Pest Management. k. No other unresolved concerns or complaints by building personnel are known. If false, list any pending issues not previously mentioned in this report here: We switched cleaning companies this past summer and are dealing with issues of inconsistent cleaning. We are working on maintaining a consistent cleaning staff and thus maintaining consistent cleaning standards. l. There are no incomplete HVAC preventative maintenance (PM) work requests. If false, list any incomplete HVAC work request here: 6. Bathrooms and General Plumbing a. All locker or restroom exhaust fans are working. Inoperable or malfunctioning fans are listed as follows: Location: Problem: b. All of the following drain-trap maintenance procedures are being conducted according to the frequency indicated. If false, indicate all deviations and locations: i. Water is poured into floor drains once per week (approximately 1 quart of water) or water and a teaspoon of cooking oil poured into the drain once a month. The Custodial staff is reminded regularly of these procedures. ii. Water is poured into sinks at least once per week (about 2 cups of water). iii. Toilets are flushed at least once per week. 7. Lab Chemicals & Maintenance Supplies a. Lab chemicals are used with exhaust fans turned on. Page 6 of 9 Revised 3/21/2011 AMJ Created 11/2010 IAQ Check List Building: Lake Zurich Middle School North Date: November 8, 2013 Building Inspection Performed by: Lyle Erstad Report Compiled by: Lyle Erstad Check List b. Lab chemical storage areas have been inspected yearly by ROE and Fire Department. Record last inspection dates below: ROE: 10/2013 LZFD: Yet to be scheduled. IAQ Check List True False N/A c. Flammables are not stored with igniters. d. All chemicals that may react or produce toxic or explosive by-products are separated and maintained in approved containers stored in approved storage. (e.g. lockable, with appropriate ventilation). e. Chemical disposal records for all lab chemicals are available for review. f. All cleaning products used in building contain no/low VOC. List any exceptions: g. Increased ventilation is considered when installing new carpets, cleaning upholstered furniture, shampooing carpets, etc. h. Exhaust ventilation systems in chemical and trash storage areas are turned on and functioning properly. i. Portable fuel containers are properly closed. j. Power equipment, like snow blowers and lawn mowers, have been serviced and maintained according to manufacturers’ guidelines. k. Oil based paints are stored in approved storage cabinets. No oil based paints allowed in the district. l. Green Cleaning products and processes are used in this building. Page 7 of 9 Revised 3/21/2011 AMJ Created 11/2010 IAQ Check List Building: Lake Zurich Middle School North Date: November 8, 2013 Building Inspection Performed by: Lyle Erstad Report Compiled by: Lyle Erstad Check List 8. IAQ Check List True False N/A Combustion Appliances a. Combustion analysis is performed at the start of the heating season on all boilers. Adjustments are made to the burners to correct any abnormalities and improve efficiency. We have not been able to schedule Barr Mechanical to conduct the combustion analysis due to the fact that our heating season has just begun. This will be scheduled and we will report back at the Winter IAQ meeting. b. In rooms that contain combustion appliances, there is no evidence of combustion gas or fuel odors. If false, record locations here: Kitchen - A pilot light had gone out. c. No leaks, disconnections, and/or deterioration were found on exhaust hoods. d. Flue components are clean and free of soot. e. All combustion appliances have flues or exhaust hoods and vent NO2. i. If false, inspect cooking hoods, chemical hoods. Assure that cooking stoves and appliances are correctly installed, used, and maintained according to manufacturers’ specifications. ii. If not vented, ensure that “leave-in” CO monitors are placed in room. Record locations here: iii. CO levels in rooms with combustion appliances are measured and recorded with an IAQ monitor. CO readings outside of normal CO range will result in an immediate response by maintenance to reduce CO level or vacating the room/building, if necessary. Record locations here: 9. Other a. Paint No peeling and/or flaking paint found. If planned building renovation will damage paint or if peeling paint is discovered, lead testing may be necessary. If peeling paint is found, send email to the building Principal and the Facilities Director alerting them of the problem. Staff and teachers need to pick up any flakes of paint to prevent Page 8 of 9 Revised 3/21/2011 AMJ Created 11/2010 IAQ Check List Building: Lake Zurich Middle School North Date: November 8, 2013 Building Inspection Performed by: Lyle Erstad Report Compiled by: Lyle Erstad Check List children from being exposed. The Facilities Director will advise the Facilities Coordinator (a Certified Lead Paint Renovator) to test the paint for lead. Lead paint was discontinued in 1978. Buildings built after 1978 are exempt from lead paint testing. IAQ Check List True False N/A If lead is present, required repairs should be done immediately using lead-safe methods and, if necessary, a licensed lead contractor. Location(s) of known peeling paint in building: b. The following preventive measures are being taken to reduce lead exposure. i. Play areas and toys are cleaned nightly. ii. Floors are mopped nightly. iii. Dust at least weekly. c. Radon testing is recommended by IEMA every 5 years. Last testing date listed below: Date: 12/14/2011 - 12/16/2011; Reading of 1.5pCi/L (Highest) in multiple rooms National concern: 4.0 pCi/L d. The IAQ testing equipment used for this inspection was calibrated and is in good working order. Equipment Used: Gray Wolf Last date of calibration: 1/8/13 Page 9 of 9 Revised 3/21/2011 AMJ Created 11/2010 MSN Fall 2013 IAQ Data Site North North North North North North North North North North North North North North North North North North North North North North North North North North Location Outdoor Air A100 A104 A105 A106 A107 A108 A109 A110 A111 A112 A113 A114 A115 B102 B104 B106 B108 B114 B118 Honegger Jakowitsch Main office Nurse Vastine Zabel Date/Time 10/25/2013 2:13:36 PM 10/25/2013 1:43:36 PM 10/25/2013 1:46:18 PM 10/25/2013 1:50:26 PM 10/25/2013 1:48:21 PM 10/25/2013 1:52:09 PM 10/25/2013 1:54:22 PM 10/25/2013 1:56:36 PM 10/25/2013 2:00:44 PM 10/25/2013 1:58:39 PM 10/25/2013 2:09:18 PM 10/25/2013 2:02:51 PM 10/25/2013 2:05:41 PM 10/25/2013 2:07:33 PM 10/25/2013 1:40:41 PM 10/25/2013 1:38:26 PM 10/25/2013 1:29:26 PM 10/25/2013 1:30:51 PM 10/25/2013 1:33:29 PM 10/25/2013 1:35:13 PM 10/25/2013 1:20:54 PM 10/25/2013 1:23:58 PM 10/25/2013 1:17:59 PM 10/25/2013 1:13:26 PM 10/25/2013 1:22:20 PM 10/25/2013 1:16:19 PM °F 52.4 72.1 71.5 72.3 72 73 73.3 73.1 73.3 73.4 74 73.5 74.5 74 71.2 70.2 70.8 71.1 70.9 71 70.5 71.1 70.5 69.4 70.7 69.8 %RH 22.1 24.8 23.2 23.2 24.4 26.3 23.7 24.2 23.9 24.1 23.9 23.7 34.8 23.6 24.4 22.4 24.4 25.2 22.9 21.9 22.2 22.5 22.3 24 21.9 23.3 CO ppm CO2 ppm Occupant 0.7 430 0 923 26 0 811 8 0 796 6 0 957 20 0 1244 8 0 789 20 0 1063 26 0 894 23 0 985 26 0 1051 23 0 959 22 0 2900 25 0 900 24 0 808 24 0 649 14 0 926 28 0 927 29 0 693 28 W 0 644 2 0 496 1 0 491 1 0 493 4 0 589 2 0 499 1 0 524 1 Window Date/Time °F %RH CO ppm CO2 ppm Occupant Window Notes Y CO2 Formula: 700 + 430 = 1130 Site Location Notes North North North North North North North North North North North North North North North North North North North North North North North North North North North North North North Outdoor Air 10/29/2013 10:26:25 AM A200 10/29/2013 11:57:11 AM A203 10/29/2013 11:59:05 AM A204 10/29/2013 12:00:39 PM A205 10/29/2013 12:02:43 PM B110 10/29/2013 11:34:39 AM B112 10/29/2013 11:36:17 AM B116 10/29/2013 11:38:19 AM B124 10/29/2013 12:10:54 PM B200 10/29/2013 11:55:24 AM B202 10/29/2013 12:22:12 PM B204 10/29/2013 12:20:44 PM B205 A 10/29/2013 11:42:48 AM B205 B 10/29/2013 11:45:27 AM B206 10/29/2013 12:19:03 PM B207 10/29/2013 12:24:08 PM B208 10/29/2013 12:17:27 PM B209 10/29/2013 12:25:40 PM B210 10/29/2013 12:15:44 PM B211 10/29/2013 12:27:39 PM B212 10/29/2013 12:05:35 PM B213 10/29/2013 12:13:19 PM C130 10/29/2013 11:15:33 AM Cafeteria 10/29/2013 11:17:40 AM D100 10/29/2013 11:26:28 AM Gym W 10/29/2013 11:22:50 AM Gym 10/29/2013 11:20:06 AM Library 10/29/2013 11:53:36 AM Losavio 10/29/2013 11:12:29 AM Schecter 10/29/2013 11:14:17 AM 45.1 72.4 72.1 72.6 72.5 70.9 71.4 71.5 70.8 71.3 72.4 72.3 71.3 71.3 71.9 72.6 71.9 72.7 71.8 72.9 71.9 71.8 71.8 71.3 70.4 69.6 71.2 70.5 71.7 71.3 59.8 34.1 33.8 33.6 33.9 33.9 34.8 34.7 33 33.9 33.3 34.2 35.1 34.6 33.4 34.5 33.7 34 34 34.2 32.8 33.5 34 33.9 37.5 36.4 33.2 32.6 33.4 33.2 CO2 Formula: 700 + 410 = 1110 Site Location Date/Time North Outdoor Air 10/31/2013 11:25:13 AM °F 60.5 %RH 84 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 410 732 774 722 816 579 734 646 654 709 679 791 805 788 680 885 725 792 754 830 655 694 587 591 890 1092 462 499 476 512 9 6 10 9 1 24 29 2 3 8 25 2 2 24 30 24 20 24 22 5 20 1 240 26 26 31 2 1 1 Y CO ppm CO2 ppm Occupant 0 379 Window Notes North North North North North North North North North A102 A103 A107 A114 A213 A215 B100 Principal Staff Lounge 10/31/2013 11:45:02 AM 10/31/2013 11:42:51 AM 10/31/2013 11:40:57 AM 10/31/2013 11:48:43 AM 10/31/2013 11:55:07 AM 10/31/2013 11:52:37 AM 10/31/2013 11:36:32 AM 10/31/2013 12:13:04 PM 10/31/2013 11:32:20 AM 70.5 69.9 69.9 71.6 71.5 71.6 67.7 71 66.8 58.5 57.3 61.2 59.7 53.6 54.6 61.2 59.8 75 Date/Time 11/6/2013 10:59:49 AM 11/6/2013 11:44:07 AM 11/6/2013 11:50:12 AM 11/6/2013 11:55:04 AM 11/6/2013 11:13:18 AM 11/6/2013 11:15:27 AM 11/6/2013 11:18:59 AM 11/6/2013 11:17:09 AM 11/6/2013 11:20:42 AM 11/6/2013 11:22:36 AM 11/6/2013 11:26:00 AM 11/6/2013 11:27:59 AM 11/6/2013 11:24:21 AM 11/6/2013 11:52:24 AM °F 50.8 71.4 70.1 70.8 68 68.8 69.3 69.3 69.6 70 70.3 70.8 70.4 71.2 %RH 78.4 51.1 46.2 46.3 62.8 62.4 56.6 60 55.4 55.5 54.7 53.2 55 47.6 0 0 0 0 0 0 0 0 0 1055 965 1235 1799 1176 1253 969 539 1083 23 1 9 29 23 26 2 1 17 CO2 Formula: 700 + 379 = 1079 Site North North North North North North North North North North North North North North Location Outdoor Air A107 A114 A202 A206 A207 A208 A209 A210 A211 A212 A213 A214 A215 CO2 Formula: 700 + 742 = 1442 CO ppm CO2 ppm Occupant 0 742 0 1006 9 0 765 27 0 624 2 0 844 25 0 772 7 0 768 28 0 874 23 0 901 22 0 953 27 0 925 25 0 856 20 0 879 19 0 979 23 Window Notes