PORTFOLIO TM D ES C R IPTION Low brightness 7-3/8-inch aperture downlight for use with a 26W, 32W or 42W Triple Twin Tube 4-pin compact fluorescent lamp. The precisely formed non-imaging optical reflector ensures 55° cutoff to lamp and lamp image and the one piece design eliminates light leaks at the ceiling. Standard features include low iridescent finish on all reflector colors to eliminate "rainbowing" and one electronic ballast to operate 26W, 32W or 42W TTT lamps. Venting ensures maximum lamp life and lumen output. Open downlight, open wall wash and lensed trims are interchangeable within the same housing. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S Re f l e c t o r U ni v e rs a l Moun ting B racket Electron ic B allast .050 thick aluminum, in a one piece spun parabolic contour. Available in a variety of Alzak® finishes. Also available with white or black baffle. Positive reflector mounting, without tools, pulls trim tight to ceiling. Accepts 1/2" EMT, C Channel, T bar fasteners, and bar hangers. Adjusts 5" vertically from above or below ceiling. Electronic ballast provides full light output and rated lamp life. Provides flicker free and noise free operation and starting. Condui t F i tti ngs Labels Die cast screw tight connectors. cULus listed, standard damp label. Trim Ring Options J unc ti on Box Self flanged or molded white trim ring. Rimless or metal trim ring accessories available. Listed for eight #12AWG (four in, four out) 90°C conductors feed through branch wiring. 1/2" and two 3/4" pry outs. Positioned to allow straight conduit runs. Access to junction box by removing reflector. So c k e t C o n n e c t or One piece die cast aluminum connection allows venting for maximum thermal performance. C7142 7151/7150 Soc ke t H ou s i n g M o u n t i n g F ra me One piece precision die cast aluminum 1-1/2" deep collar accommodates varying dimensions ofceiling materials. 26W, 32W, 42W 4 pin GX24q-3/4 base with fatigue free stainless steel lamp spring ensures positive lamp retention. TTT or PLT Compact Fluorescent STEPREPEAT> 7-Inch Open Downlight ENERGY DATA 26W TTT 4-pin To p V i ew Ballast: Electronic 8" [203mm] 13-5/16" [341mm] 120V Input Watts: 29 Line Amps: 0.25 277V Input Watts: 29 Line Amps: 0.10 Power Factor: >0.99 THD: <10% Min. Starting Temperature: -10°C (15°F) Sound Rating: Class A Standards 32W TTT 4-pin Ballast: Electronic 14" [355mm] 120V Input Watts: 34.5 Line Amps: 0.30 277V Input Watts: 34.5 Line Amps: 0.13 Power Factor: >0.99 THD: <10% Min. Starting Temperature: -10°C (15°F) Sound Rating: Class A Standards 20" [508mm] 42W TTT 4-pin Ballast: Electronic 17-5/8" [448mm] With EM Option 7-3/8" [187mm] 8-1/8" [204mm] 8-3/4" [222mm] Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. 120V Input Watts: 48 Line Amps: 0.32 277V Input Watts: 48 Line Amps: 0.18 Power Factor: >0.99 THD: <10% Min. Starting Temperature: -10°F (0°C) Sound Rating: Class A Standards NOTES: Accessories should be ordered separately. For additional options, please consult your Cooper Lighting Representative. Alzak is a registered trademark of Aluminum Company of America. ADP985019 2013-09-27 16:00:00 C7142 7151/7150 OR D ER ING INFOR M A TION EXAMPLE: C7142E 7151LI Housing Number of Lamps Wa tt a g e Ballast Options 42=26W, 32W, or 42W TTT or PLT Lamp C7=7" 1=1 Lamp Horizontal Lamp E=120/277V 50/60 Hz Electronic 3E=347V 50/60 Hz Electronic D5LT26=26W 120-277V Fifth Light (DALI Dimming) D5LT32=32W 120-277V Fifth Light (DALI Dimming) D5LT42=42W 120-277V Fifth Light (DALI Dimming) CP=Chicago Plenum EM= Emergency Module with RemoteTest Switch IEM= Emergency Module with integral test switch 3D5LT26/32=26 or 32W 347V Fifth Light (DALI Dimming) 3D5LT42=42W 347V Fifth Light (DALI Dimming) D26/32 D26/32=26 or 32W 120-277V Lutron Ecosystem Dimming D42=42W 120-277V Lutron Ecosystem Dimming EDR26=DeRated Wattage Label, 26W EDR32=DeRated Wattage Label, 32W Tri m s Finish 7151=Self Flanged 7150=Molded Trim Ring 7151E=Self Flanged, use with IEM 7150E=Molded Trim Ring, use with IEM LI=Low Iridescent Clear H=Haze WMH=Warm Haze G=Gold WH=Wheat W=Gloss White GP=Graphite GPH=Graphite Haze BB=Black Baffle (7150 only) WB=White Baffle (7150 only) Options WF=White painted Flange (Self Flanged only) Notes: 1Order trim with polymer trim ring (Consult specification sheet for ordering information and options). A c c e s s o ri e s HB26=C Channel Bar Hangers, 26" Long, Pair HB50=C Channel Bar Hangers, 50" Long, Pair TRM7=Metal Trim Ring, Specify Finish 1 TRR7=Rimless Trim Ring, White 1 FK5=5 Amp Field Installable Fuse Kit 300V Max DT7=Deco Trims 1 RMB-22=Wood Joist Bar Hanger, 22" Long, Pair HSA7=Slope Adapter for 7" Aperture Housings, Specify Slope PHOTOM ETR IC S C7142 7151/7150 Candlepower Distribution Test No. H23199 C7132-7150LI Open Reflector Lamp=32W PLT Lumens=2400 Spacing Criteria= 0°=1.4, 90°=1.6 150 300 450 600 Efficiency=65.7% 750 900 0° 90° Zonal Lumen Summary %Lamp 26.7 Candlepower Average Luminance Deg. Deg Cone of Light 0 CD 0° 670 90° 670 45 .CD/SQ M 0° 90° 17127 19082 5 15 25 678 726 743 696 770 818 55 65 75 19471 549 0 35 565 795 85 0 45 55 65 75 334 308 0 0 372 329 6 0 85 90 0 0 0 0 20811 515 0 0 Distance to Illuminated Plane 5'6" 6'6" 8'6" 10'0" Lumens 640 %Luminaire 40.6 0-40 0-60 0-90 1074 1569 1577 44.7 65.4 65.7 68.1 99.5 100.0 90-180 0-180 0 1577 0.0 65.7 0.0 100.0 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Beam Diameter 8'6" 10'6" 12'6" 16'0" 22 16 10 7 5 3 12'0" 14'0" 19'0" 22'0" Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary. Lamp Multiplier: Reflector EM Multiplier Multiplier: (in emergency 32W TTT=.87 mode) Haze=.95 Straw=.9 Wheat=.9 C o e f fi c i e n t o f U t i l i z a t i o n Zone 0-30 Initial Nadir Footcandles 80% 70% 50% EM=.27 30% 10% 0% 70 50 30 10 50 30 10 50 10 50 10 50 10 0 78 78 78 78 76 76 76 73 73 70 70 67 67 66 74 72 70 68 71 69 67 68 65 65 63 63 62 60 70 66 66 61 63 57 61 54 65 60 63 57 60 54 63 58 59 53 61 57 58 52 59 55 56 51 55 50 62 58 56 51 52 47 49 44 55 51 51 46 48 43 54 49 48 43 52 48 47 43 51 47 47 42 46 41 54 47 42 39 46 42 39 45 39 44 38 43 38 37 50 46 42 39 38 34 34 31 42 38 38 34 34 31 41 38 34 31 40 37 34 30 39 36 34 30 33 29 43 35 31 27 35 30 27 34 27 40 32 28 25 32 27 24 31 24 rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance. 34 31 27 24 33 30 27 24 26 23 Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 ADP985019 2013-09-27 16:00:00 C7142 7151/7150 C7142 7151/7150 Candlepower Distribution Test No. H23233 C7142-7150LI Open Reflector Lamp=42W PLT Lumens=3200 Spacing Criteria 0°=1.4, 90°=1.7 200 400 600 Efficiency=59.6% 800 0° 90° 1000 Zonal Lumen Summary Lumens 743 0-40 1287 40.2 67.4 0-60 0-90 1889 1909 59.0 59.6 99.0 100.0 0 0.0 0.0 1909 59.6 100.0 0-180 Average Luminance Deg. CD 0° 90° Deg 0 5 15 677 641 626 677 720 857 45 55 65 22467 11636 1030 27238 15556 1116 25 799 958 75 561 701 35 45 613 438 946 531 85 416 416 55 184 246 65 75 12 4 13 5 85 1 1 90 0 0 Cone of Light .CD/SQ M 0° 90° Distance to Illuminated Plane %Luminaire 38.9 Beam Diameter 9'0" 11'0" 13'6" 16'6" 20'0" 23'6" 22 16 11 7 5 3 Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary. Lamp Multiplier: Reflector EM Multiplier Multiplier: (in emergency mode) Haze=.95 Straw=.90 Wheat=.90 80% rc Initial Nadir Footcandles 5'6" 6'6" 8'0" 10'0" 12'0" 14'0" C o e f fi c i e n t o f U t i l i z a t i o n Zone 0-30 90-180 %Lamp 23.2 Candlepower 70% 50% EM=.27 30% 10% 0% rw RCR 0 70 50 30 10 50 30 10 50 10 50 10 50 10 0 71 71 71 71 69 69 69 66 66 63 63 61 61 60 1 2 3 67 63 65 60 64 57 62 55 64 59 62 57 61 54 61 57 59 53 59 55 57 52 57 54 56 51 55 50 59 56 55 51 52 47 49 44 54 50 51 46 49 44 53 49 48 43 51 47 47 43 50 46 46 42 45 41 4 5 52 46 42 39 46 42 39 45 39 44 38 43 38 37 6 48 42 38 35 42 38 35 41 35 40 34 39 34 33 7 8 45 42 38 35 34 30 31 27 38 34 34 30 31 27 37 34 31 27 36 33 30 27 35 32 30 27 29 26 9 10 39 31 27 24 31 27 24 31 24 30 24 29 24 23 36 29 24 21 28 24 21 28 21 rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance. 27 21 27 21 20 Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 ADP985019 2013-09-27 16:00:00