PORTFOLIO TM D ES C R IPTION Low brightness 7-3/8-inch aperture crossblade for use with a 26W, 32W or 42W Triple Twin Tube compact fluorescent lamp. Reflector trim eliminates brightness at higher angles. One electronic ballast to operate 26W, 32W and 42W triple tube 4-pin lamps. Venting ensures maximum lamp life and lumen output. Open downlight, lensed, and open wall wash trims are interchangeable within the same housing. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S Re f l e c t o r Hous i ng Mountin g Frame S ock et Clear upper Alzak® reflector for maximum output. Positive reflector mounting, without tools, pulls trim tight to ceiling. Option 5: Lower spun parabolic reflector with 90° crossblades, .050 thick aluminum, available in a variety of Alzak® finishes. Option 6: Lower spun parabolic reflector painted white with 90° perforated crossblades, .050 thick aluminum, painted gray. One piece precision die cast aluminum 1-1/2" deep collar accommodates varying dimensions of ceiling materials. 4 pin GX24q-3/4 base with fatigue free stainless steel lamp spring ensures positive lamp retention. Trim Ring Options Electron ic B allast Accepts 1/2" EMT, C Channel, T bar fasteners, and bar hangers. Adjusts 5" vertically from above or below ceiling. Electronic ballast provides full light output and rated lamp life. Provides flicker free and noise free operation and starting. End of lamp life protection is standard. Condui t F i tti ngs Labels Die cast screw tight connectors. cULus listed. Damp label. U ni v e rs a l Moun ting B racket Self flanged trim ring. C7142 7181 J unc ti on Box So c k e t C o n n e c t or One piece die cast aluminum connection allows venting for maximum thermal performance. Listed for eight #12AWG (four in, four out) 90°C conductors feed thorough branch wiring. For 1/2" and two 3/4" pry outs. Positioned to allow straight conduit runs. Access to junction box by removing reflector. 26W, 32W, 42W TTT or PLT Compact Fluorescent STEPREPEAT> 7-Inch Crossblade Top View 8" [203mm] ENERGY DATA 26W TTT 4-pin Ballast: Electronic 13-13/32" [341mm] 120V Input Watts: 29 Line Amps: 0.25 277V Input Watts: 29 Line Amps: 0.10 Power Factor: >0.99 THD: <10% Min. Starting Temperature: -10°C (15°F) Sound Rating: Class A Standards 15-3/8" [391mm] . 32W TTT 4-pin Ballast: Electronic 120V Input Watts: 34.5 Line Amps: 0.30 277V Input Watts: 34.5 Line Amps: 0.13 Power Factor: >0.99 THD: <10% Min. Starting Temperature: -10°C (15°F) Sound Rating: Class A Standards 42W TTT 4-pin 7-3/8" [187mm] Ballast: Electronic 8-1/8" [204mm] 8-3/4" [222mm] 120V Input Watts: 48 Line Amps: 0.32 277V Input Watts: 48 Line Amps: 0.18 Power Factor: >0.99 THD: <10% Min. Starting Temperature: -10°F (0°C) Louver Option 5 Louver Plan View Louver Option 6 Sound Rating: Class A Standards NOTES: Accessories should be ordered separately. For additional options, please consult your Cooper Lighting Representative. Alzak is a registered trademark of Aluminum Company of America. Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. ADP040657 2013-09-27 16:00:00 C7142 7181 OR D ER ING INFOR M A TION EXAMPLE: C7142E 7181LI5 Housing C7=7" Horizontal Lamp Number of Lamps 1=1 Lamps E=120/277V 50/60 Hz Electronic 3E=347V 50/60 Hz Electronic D5LT26=26W 120-277V Fifth Light (DALI Dimming) D5LT32=32W 120-277V Fifth Light (DALI Dimming) D5LT42=42W 120-277V Fifth Light (DALI Dimming) Wa tt a g e Ballast Options 42=26W, 32W, 42W TTT or PLT Lamp Tri m s CP=Chicago Plenum EM=Emergency Module with RemoteTest Switch 3D5LT26/32=26 or 32W 347V Fifth Light (DALI Dimming) 3D5LT42=42W 347V Fifth Light (DALI Dimming) D26/32=26 or 32W 120-277V Lutron Ecosystem Dimming D42=42W 120-277V Lutron Ecosystem Dimming EDR26=DeRated Wattage Label, 26W EDR32=DeRated Wattage Label, 32W L o u ve r Options A c c e s s o ri e s 5=Blade (LI or W Matching Blade Finish) 6=Perforated Blade (Lt Grey Blades, W Finish only) WF=White painted Flange (self Flanged only) HB26=C Channel Bar Hangers, 26" Long, Pair HB50=C Channel Bar Hangers, 50" Long, Pair FK5=5 Amp Field Installable Fuse Kit 300V Max RMB-22=Wood Joist Bar Hanger, 22" Long, Pair Finish 7181=Lensed Self-Flanged LI=Low Iridescent Clear W=Gloss White PHOTOM ETR IC S C7142 7181 Candlepower Distribution Test No. H23348 C7132 7181LI5 Reflector Lamp=(1)32W PLT Lumens=2400 Spacing Criteria=1.2 Efficiency=45.3% 210 420 630 Candlepower Average Luminance Deg. Deg. 0 CD 0° 595 90° 0 5 608 59 15 25 634 600 180 275 35 45 493 210 297 170 55 65 75 64 14 4 81 21 4 85 90 1 0 1 0 Cone of Light CD/SQ M 45 10908 55 65 75 85 4102 1255 498 253 Distance to Illuminated Plane Initial Nadir Footcandles 4' 6" 5' 6" Beam Diameter 6' 0" 7' 6" 29 20 14 9 6' 6" 8' 0" 10' 0" 12' 0" 8' 6" 10' 6" 13' 0" 16' 0" 6 4 Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary. EM Multiplier (in emergency mode) EM=.26 Zonal Lumen Summary Zone Lumens %Lamp C o e f fi c i e n t o f U t i l i z a t i o n %Luminaire 0-30 0-40 514 811 21.4 33.8 47.2 74.5 0-60 1062 44.2 97.6 0-90 90-180 1088 0 45.3 0.0 100.0 0.0 0-180 1088 45.3 100.0 80% rc 70% 50% 30% 10% 0% 70 50 30 10 50 30 10 50 10 50 10 50 10 0 1 54 51 54 49 54 48 54 47 53 48 53 47 53 46 50 47 50 45 48 45 48 43 46 43 46 42 45 41 2 3 4 48 45 42 45 41 37 43 38 34 41 36 3 44 40 37 42 38 34 40 36 32 43 39 36 40 35 32 41 38 35 39 35 31 40 37 34 38 34 31 37 33 30 5 6 7 39 34 31 29 34 31 29 33 28 32 28 31 28 27 36 32 28 26 31 28 26 30 26 30 25 29 25 24 34 32 29 27 26 24 24 21 29 27 26 24 23 21 28 26 23 21 28 26 23 21 27 25 23 21 22 20 30 25 22 20 25 22 20 24 20 24 19 23 19 19 28 23 20 18 23 20 18 23 18 22 18 22 18 17 rw RCR 0 8 9 10 rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance. Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 ADP040657 2013-09-27 16:00:00 C7142 7181 C7142 7181 Candlepower Distribution Test No. H35147 C7142-7181P6 Lamp=42W Lumens=3200 Spacing Criteria= 0°=0.9, 90°=0.9 Efficiency=24.5% 250 500 750 Zonal Lumen Summary Zone Lumens %Lamp Candlepower Average Luminance Deg. CD 0° 90° Deg. 0 5 721 706 721 707 45 55 6053 4437 5882 4261 15 617 616 65 3697 3525 25 35 45 453 238 106 433 211 103 75 85 2972 2449 2800 2402 55 63 61 65 75 39 19 37 18 85 90 5 0 5 0 Cone of Light CD/SQ M 0° 90° Distance to Illuminated Plane Initial Nadir Footcandles 4'5" 5'5" 6'5" 8'0" Beam Diameter 4'5" 5'5" 7'0" 8'5" 29 20 11 7 5 4 10'0" 12'0" 10'5" 12'5" Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary. C o e f fi c i e n t o f U t i l i z a t i o n %Luminaire 0-30 0-40 434 576 13.5 18.0 55.4 73.5 0-60 0-90 718 783 22.5 24.5 91.7 100.0 90-180 0-180 0 783 0.0 24.5 0.0 100.0 70 50 30 10 50 70% 30 10 50 10 50 10 50 10 0% 0 0 1 2 3 29 27 29 26 29 26 29 25 28 26 28 25 28 25 27 25 27 24 26 24 26 23 25 23 25 22 24 22 26 24 24 22 23 20 22 19 24 22 22 20 22 19 23 21 21 19 22 20 21 18 21 20 20 18 20 18 4 5 6 22 21 20 19 19 17 17 16 20 18 18 17 17 16 19 18 17 15 19 17 17 15 18 17 17 15 16 15 20 17 16 14 17 15 14 17 14 16 14 16 14 14 7 8 19 18 16 15 14 13 13 12 16 15 14 13 13 12 16 15 13 12 15 14 13 12 15 14 13 12 12 12 17 14 12 11 14 12 11 14 11 16 13 12 11 13 12 11 13 11 rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance. 13 13 11 10 13 13 11 10 11 10 rc rw RCR 9 10 80% 50% 30% Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 10% ADP040657 2013-09-27 16:00:00