IRIS DESCRIPTION Recessed dropped decorative lens downlight luminaire with 5 inch aperture utilizing vertical 26/32W TTT compact fluorescent lamp. Platform is suitable for commercial construction. Insulation must be kept 3" from top and sides of housing. Drop decorative lens obscures lamp and provides smooth distribution. ® Type Catalog # Project Date Comments Prepared By S P E C I F I C AT I O N F E AT U R E S Frame Galvanized steel plaster frame with integral bar hanger receivers. Setscrews provide positive horizontal locking. Integral gun sights facilitate the use of guide strings or laser lines. Shipped with overspray protector installed. Housing Steel housing painted matte black for a visually dark interior. Bar Hangers Bar hangers adjust from 8-1/2" to 24" wide; pass thru feature allows shortening without removal. Captive nail penetrates standard and engineered lumber. Mounting flange levels platform with ceiling. Integral clip attached directly to tee-bar. Gaskets Closed cell gaskets achieve restrictive airflow requirements without additional caulking. Reflector Spun 0.04" thick aluminum upper reflector with white powder coat finish. Field replaceable veined decorative frosted glass lens obscures lamp and provides smooth distribution. Flange Reflector is available self flanged, flange finish follows reflector finish, self flanged also available with painted white flange. Reflector also available with die cast flange in painted white or raw aluminum with protective clear coat. The die cast flange can be removed for field painting and is keyed to maintain proper orientation. Trim Retention Retained with two torsion springs holding the flange tightly to the finished ceiling surface and accommodates ceiling thickness with 1/2 -1" thick. Uses PLE5 to adapt to ceilings up to 2" thick. Junction Box Rated for (4) #12 or (6) #14 AWG thru branch, (5) 1/2" trade size pry outs positioned to allow straight conduit runs. Ballast Thermally protected unicersal input 120-277V electronic ballast provides program start for full light output and rated lamp life. Multi wattage output for 26 or 32W triple twin tube lamps. Available with 1% and 5% dimming options, see ordering information for details. PN532 E5LUNA Compliance Thermally protected, cULus listed for wet locations and ASTM-E283 AIRTITEtm. Nonconductive glass lens is non conductive and meets local cost requirements for 'dead front' requirements. EMI/RFI emissions per FCC 47CFR Part 18 non consumer limits. 26/32W Compact Fluorescent Drop Lens Decorative 5" Aperture 8-1/2" [216mm] 16-1/2" [419mm] 4-15/16" [126mm] 8-1/2" [216mm] Ceiling Cutout 6-1/4" [159mm] 2-1/4" [54mm] ENERGY DATA 26W Input Voltage 120V 277V Input Current 0.24 0.11 Input Power 29 29 Input Voltage 120V 277V Input Current 0.31 0.13 Input Power 36 36 32W 6-1/4" [159mm] 7-1/4" [184mm] THD: ≤ 10% PF: ≥ .98 T Ambient -30o C - +40o C Sound Rating A Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. ADI121722 12-03-2012 IRIS ® O R D E R I N G I N F O R M AT I O N : C o m p l e t e u n i t c o n s i s t s o f p l a t f o r m , l a m p m o d u l e a n d o p t i c a l e l e m e n t . Example: PN5 + 32 + E5LUNA P l a t fo rm L a m p Ty p e / Wa tt a ge Ballast PN5 PN5 = 5" Aperture Non-IC, AT CFL platform Housing A c c e s s o ri e s Optical Element E5LUNA 26 = 26W TTT CFL derated label 32 = 26/32W TTT CFL E5LUNA = 5" aperture E = UNV 120-277V electronic, decorative lens 50/60Hz 3E = 347V electronic, 50/60Hz ED26/32ES = 120-277V, 50/60Hz 26/32W electronic 5% 3-wire & EcoSystems 1D26HL = 120V, 60Hz 26W electronic 1% 3-wire dimming 1D32HL = 120V, 60Hz 32W electronic 1% 3-wire dimming 2D26HL = 277V, 60Hz 26W electronic 1% 3-wire dimming 2D32HL = 277V, 60Hz 32W electronic 1% 3-wire dimming PLE5 = Plaster lip extension, for ceilings up to 2" thick P H OTO M E T R I C S PN532 E5LUNA PN532-E5LUNA Test No. H36081 Lamp: Lumens: 32W PLT 2400 Spacing: Efficiency: Unit LPW: Candelas Vertical Angle 90 85 75 65 55 45 35 25 15 5 0 1.4 35.9% 23.9 Distribution Cone of Light Distance to Illum. Plane CD 48 59 84 114 144 173 196 211 218 219 219 Initial Nadir Footcandles Single Fixture 2'0" Distance from Wall Beam Diameter 1' 2' 15 12 7 4 3 2 1 1 1 0 7 7 5 3 2 1 1 1 1 0 3' 4' DD 4'6" 5'6" 6'6" 8'0" 10'0" 12'0" 6'0" 7'0" 8'6" 10'6" 13'0" 15'6" 11 7 5 3 2 2 1 21 2 15 3 8 4 5 5 3 6 2 7 1 8 1 9 1 10 0 Lamp Multiplier: 26W= .75 3 4 3 2 2 1 1 1 0 0 2 2 2 2 1 1 1 1 0 0 0° Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180 Lumens 180 302 565 832 31 863 %Lamp 7.5 12.6 23.5 34.7 1.3 35.9 C o e ffi c i e n t o f U t i l i z a t i o n %Luminaire 20.8 35.0 65.5 96.4 3.6 100.0 Ceiling Reflectance Wall Reflectance Room Cavity Ratio 0 1 2 3 4 5 6 7 8 9 10 70 50 80% 30 10 50 70% 10 50 50% 10 50 30% 10 0% 0 43 38 34 31 29 26 24 43 36 31 27 24 21 19 43 34 28 24 21 18 16 43 32 26 21 18 15 13 41 35 30 26 23 21 19 41 32 26 21 18 15 13 39 33 29 25 22 20 18 39 31 25 21 18 15 13 37 32 27 24 21 19 17 37 29 24 20 17 15 13 35 27 22 19 16 14 12 22 20 19 18 17 15 14 13 14 12 11 10 11 10 9 8 17 15 14 12 11 10 9 8 16 14 13 12 11 10 8 7 15 14 13 11 11 10 8 7 10 9 8 7 Notes and Formulas: Cone of Light: • Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. • Footcandle values are initial. Apply appropriate light loss factors where necessary. Wall Illumination: • Illuminance values are cosine corrected initial values with no contribution from inter reflections from other room surfaces. Total illumination may increase from contributions from other surfaces. • DD=Distance Down from Ceiling. Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. ADI121722 12-03-2012