Document 13743201

advertisement
NEO-RAY
DESCRIPTION
Neo-Ray's 174 is part of the recessed narrow center basket series. The 4"
wide flush narrow basket diffuser offers interior spaces both comfortable
lighting and economy. T5 fluorescent configurations produce efficiencies of
close to 80% which means typical rooms may be illuminated with
approximately 10% less fixtures when compared to recessed parabolics.
This installation cost differential makes the Fenestra flush narrow basket
comparable to the cost of 2'x4' recessed parabolic system.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
A ... Construction
20-gauge steel housing (1'x4').
B ... Shielding
Precision formed perforated metal
panels backed by a white acrylic
diffuser.
C ... Electrical
120, 277, 347, or Universal Voltage
electronic ballast. Fixtures and
electrical components certified to
UL and CUL standards.
Note: Please consult factory,
Fifthlight may not be available in
some configured options.
D ... Finish
Durable, low gloss, white, powder
coated acrylic finish.
Mounting
Recessed. Specify:
(ETG) 15/16" Flat Exposed T-grid,
(STG) 9/16" Screw Slot T-grid,
(SR) Sheet Rock (Flanged),
(FTG) 9/16" Flat Exposed T-grid.
Fenestra
174
TIE WIRES
(NOT SUPPLIED
1 & 2T5
1 & 2T5HO
BY NE O-R AY)
Recessed
Direct - Indirect
A
B
C D
Light Distribution
Indirect - 0.0%
Direct - 100.0%
5"
[127mm]
TANNENBAUM
12" [305mm]
Optional rippled aluminum reflector.
ORDERING INFORMATION
Series
174=1' x 4'
Options 1
C=Chicago Plenum
Number of Lamps
A=Air Return
T=Tannenbaum
Reflector
1=1 Lamp
2=2 Lamps
Mounting
R=Recessed
Notes: 1
2
(Not included)
Ceiling Type
ETG=15/16" Exposed
T-Grid
STG=Slot T-Grid
SR=Sheet Rock (Flanged)
Lamp Type
T5
T5HO
Voltage
1=120V
2
2=277V
3=347V
U=Universal
Ballast
EB=Electronic Ballast
(Standard)
DB=Dimming Ballast
Emergency
EM=Emergency Pack (Consult Factory)
Can be left blank or more than one option may be available, consult factory.
Not all options available. Please consult your Cooper Lighting Representative for availability.
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADN041912
09/20/2013 8:13:22 PM
PHOTOMETRICS
Fenestra 174
Coefficients of Utilization
174-T5
(2) FP28T5/835
2900 Lumens
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Candela
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
83
77
71
65
60
55
50
46
43
39
36
83
74
66
58
52
46
41
37
33
30
27
83
72
61
53
46
40
35
31
27
24
21
83
69
58
49
42
36
31
27
23
20
18
82
75
69
64
58
53
49
45
41
38
35
82
73
64
57
51
45
41
36
33
29
27
82
70
60
52
46
40
35
31
27
24
21
82
69
57
49
42
35
31
27
23
20
18
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
78
70
62
55
49
44
39
35
32
28
26
75
67
60
53
48
42
38
34
31
28
25
72
65
58
52
46
41
37
33
30
27
24
70
61
52
45
38
33
28
25
21
18
16
78
68
59
51
45
39
34
30
27
23
21
78
66
56
48
41
35
30
26
23
20
17
75
65
57
50
44
38
34
30
26
23
21
75
64
54
47
40
35
30
26
23
20
17
72
63
55
49
43
37
33
29
26
23
20
72
62
53
46
40
34
30
26
23
20
17
Efficiency 70.1%
Test Report
#11804.0
Zonal Lumen Summary
Luminance Data
Zone
Lumens
%Lamp
%Fixture
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
1154
1887
3342
4067
0
0
0
0
4067
19.9
32.5
57.6
70.1
0.0
0.0
0.0
0.0
70.1
28.4
46.4
82.2
100.0
0.0
0.0
0.0
0.0
100.0
Angle
in Deg
45
55
65
75
85
0-Deg
cd/sm
4129
3774
3436
2905
1537
45-Deg
cd/sm
4503
4018
3205
2376
1502
90-Deg
cd/sm
4499
3827
3162
2588
1607
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
1430
1426
1434
1399
1378
1295
1201
1109
1019
959
818
711
582
477
363
247
138
44
0
45°
1430
1427
1441
1414
1407
1336
1257
1175
1097
1046
888
757
590
445
300
202
112
43
0
Across ⊥
1430
1428
1447
1429
1433
1367
1292
1209
1117
1045
867
721
557
439
334
220
122
46
0
MOUNTING INFORMATION
STG
ETG
STANDARD LAY-IN CEILING
(GRID LAY-IN)
SCREW SLOT CEILING
(SLOT-T)
SR
SHEET ROCK CEILING
(FLANGE)
FTG
STANDARD LAY-IN CEILING
(GRID LAY-IN)
Specifications and Dimensions subject to change without notice.
Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADN041912
09/20/2013 8:13:22 PM
Download