Catalog # Type

advertisement
NEO-RAY
DESCRIPTION
A graceful arched housing with elegantly contoured perforated lamp
diffuser. Available in (1'x2') or (1'x4')configuration, this luminaire has no
visible lamps, fasteners, hardware, or glaring reflectors, just soft, diffused
wall lighting. "The Fenestra" Series 112/114 features a totally soft wide
distribution wall light. The precisely crafted components provide for a
high-tech appearance and a low tolerance fit. These elements combined
make the Neo-Ray Fenestra Series 112/114 an appropriate luminaire for
application in executive offices, private offices, conference rooms, corridors,
open office spaces, VDT workspaces, reception areas and dining spaces.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
A ... Construction
20-gauge steel housing (1'x2' or
1'x4').
B ... Shielding
Perforated metal panels backed by
a white acrylic diffuser.
C ... Electrical
120, 277, 347 or Universal Voltage
electronic ballast. Fixtures and
electrical components certified to
UL and CUL standards. Note:
Fifthlight is not available for Biax
lamps.
D ... Finish
Durable, low gloss, white, powder
coated acrylic finish.
Mounting
Recessed. Specify:
(ETG) 15/16" Flat Exposed T-grid,
(STG) 9/16" Screw Slot T-grid,
(SR) Sheet Rock (Flanged),
(FSR) Sheet Rock (Flangeless),
(FTG) 9/16" Flat Exposed T-grid.
Fenestra
112
114
TIE WIRES
(NOT SUPPLIED BY NEO-RAY)
A
B
1T5
1T5HO
Long Twin Tube
C D
Recessed
5"
[127mm]
Direct-Indirect
Wall Wash
Light Distribution:
Indirect - 0.0%
Direct - 100.0%
11-1/16" [281mm]
12" [305mm]
TANNENBAUM
S TA N DA R D L U M I N A I R E P L A N
12" x 24"
(305mm x 610mm)
(1 lamp)
12" x 48"
(305mm x 1219mm)
(1 lamp)
Optional rippled aluminum reflector.
ORDERING INFORMATION
Series
112=1' x 2'
Options 1
C=Chicago Plenum
114=1' x 4'
A=Air Return
T=Tannenbaum
Reflector
Notes: 1
2
Mounting
R=Recessed
Number of Lamps
(Not included)
1=1 Lamp
Lamp Type
T5
T5HO
BX40W
BX50W
2
Ceiling Type
ETG=15/16" Exposed T-Grid
Voltage
1=120V
FTG=9/16" Exposed T-Grid
STG=Slot T-Grid
2=277V
3=347V
SR=Sheet Rock (Flanged)
U=Universal
Ballast
EB=Electronic Ballast
(Standard)
DB=Dimming Ballast
Emergency
EM=Emergency Pack (Consult Factory)
Can be left blank or more than one option may be available, consult factory.
Not all options available. Please consult your Cooper Lighting Representative for availability.
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADN041922
09/18/2013 7:30:24 PM
Fenestra 112, 114
PHOTOMETRICS
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
7
8
112R
(1) F40/30BX3SPX35
3150 Lumens
Efficiency 47.2%
Test Report
#LSI 15655
(Consult factory for I.E.S. data
not included within this report.)
9
10
Candlepower
Vertical Angle
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
56
52
48
44
41
38
35
32
30
27
26
56
50
45
40
36
32
29
26
23
21
19
56
48
42
36
32
28
25
22
20
18
16
56
47
39
33
29
25
22
19
17
15
13
55
51
47
43
40
37
34
31
29
27
25
55
49
44
39
35
32
28
25
23
21
19
Zonal Lumen Summary
Zone
Lumens
Lamp%
0-30
440
14.00
0-40
716
22.74
0-60
1230
39.07
0-90
1487
47.22
40-90
771
24.48
60-90
256
8.16
90-180
0
.00
0-180
1487
47.22
Total Luminaire Efficiency= 47.2%
55
47
41
36
32
28
25
22
19
17
16
55
46
39
33
29
25
22
19
17
15
13
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
52
47
42
38
34
31
27
25
22
20
19
50
45
41
36
33
30
27
24
22
20
18
48
44
39
35
32
29
26
23
21
20
18
47
41
35
31
27
23
20
18
16
14
12
52
46
40
35
31
27
24
21
19
17
15
52
44
38
33
29
25
22
19
17
15
13
50
44
39
34
30
27
24
21
19
17
15
50
43
37
32
28
25
22
19
17
15
13
48
43
38
33
30
26
23
21
19
17
15
48
42
36
32
28
24
21
19
17
15
13
Fixt%
29.64
48.16
82.73
100.00
51.84
17.27
.00
100.00
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Horizontal Angle
0
45
90
570
570
570
562
591
609
551
608
639
535
614
660
512
613
675
484
605
683
452
590
682
415
569
669
374
541
645
329
504
604
281
457
538
232
400
452
183
325
360
139
238
279
100
162
211
64
99
146
32
53
80
10
18
25
0
0
0
MOUNTING INFORMATION
STG
ETG
STANDARD LAY-IN CEILING
(GRID LAY-IN)
SCREW SLOT CEILING
(SLOT-T)
SR
SHEET ROCK CEILING
(FLANGE)
FTG
STANDARD LAY-IN CEILING
(GRID LAY-IN)
Specifications and Dimensions subject to change without notice.
Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801