Catalog # Type

advertisement
NEO-RAY
DESCRIPTION
The new 4" wide flush narrow basket recessd Fenestra offers interior spaces
both comfortable lighting and economy. T5 fluorescent configurations
produce efficiencies of close to 80% which means typical rooms may be
illuminated with approximately 10% less fixtures when compared to
recessed parabolics. This installation cost differential makes the Fenestra
flush narrow basket comparable to the cost of 2'x4' recessed parabolic
system.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
A ... Construction
20-gauge steel housing. (2'x2' or
2'x4')
B ... Shielding
Precision formed perforated metal
panels backed by a white acrylic
diffuser.
C ... Electrical
120, 277, 347 or Universal Voltage
electronic ballast. Fixtures and
electrical components certified to
UL and CUL standards.
Note: Fifthlight is not available for
Biax lamps.
D ... Finish
Durable, low gloss, white, powder
coated acrylic finish.
Mounting
Recessed. Specify:
(ETG) 15/16" Flat Exposed T-grid,
(STG) 9/16" Screw Slot T-grid,
(SR) Sheet Rock (Flanged),
(FTG) 9/16" Flat Exposed T-grid.
Fenestra
272
274
TIE WIRES
(NOT SUPPLIED B Y NE O-R AY)
A
B
D
C
1 BX
1 & 2T5
1 & 2T5HO
Recessed
5"
[127mm]
Direct-Indirect
Light Distribution:
Indirect - 0.0%
Direct - 100.0%
24" [610mm]
TANNENBAUM
S TA N DA R D L U M I N A I R E P L A N
24" x 24"
(610mm x 610mm)
(1 or 2 Lamps)
Weight = 24 lbs
24" x 48"
(610mm x 1219mm)
(1 or 2 Lamps)
Weight = 45 lbs
272
274
Optional rippled aluminum reflector.
ORDERING INFORMATION
Series
272=2' x 2'
Options 1
C=Chicago Plenum
274=2' x 4'
A=Air Return
T=Tannenbaum
Reflector
Mounting
R=Recessed
Number of Lamps
(Not included)
1=1 Lamp
2=2 Lamps
Lamp Type
T5
T5HO
BX40W2
BX50W2
Notes: 1
Ceiling Type
ETG=15/16" Exposed
T-Grid
FTG=9/16" Exposed T-Grid
STG=Slot T-Grid
SR=Sheet Rock (Flanged)
Voltage
1=120V
3
2=277V
3=347V
U=Universal
Ballast
EB=Electronic Ballast
(Standard)
DB=Dimming Ballast
Emergency
EM=Emergency Pack
(Consult Factory)
Can be left blank or more than one option may be available, consult factory.
2
Fixture available with only one BIAX lamp in cross section.
3
Not all options available. Please consult your Cooper Lighting Representative for availability.
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADN041913
09/20/2013 8:11:23 PM
Fenestra 272, 274
PHOTOMETRICS
Coefficients of Utilization
272-1BX40
(1) FT40W/2G11/835/RS
3150 Lumens
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Candela
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
97
89
81
74
68
61
56
52
48
97
85
74
65
58
51
45
41
36
97
82
69
59
51
43
38
33
29
97
79
64
54
45
38
33
28
24
44
41
32 26 21
29 23 18
95
87
79
72
66
60
55
50
46
95
83
73
64
57
50
45
40
36
95
80
68
58
50
43
38
33
29
95
77
63
53
45
38
32
28
24
43 32 25 21
40 59 23 18
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
91
80
70
62
55
48
43
39
35
87
77
67
59
53
47
42
37
34
83
74
65
57
51
45
40
36
33
82
69
57
49
41
35
30
26
22
19
17
91
77
66
56
49
42
37
32
28
91
75
62
52
44
37
32
28
24
31 25 21
28 22 18
87
75
64
55
48
41
36
32
28
87
73
61
51
44
37
32
28
24
30 25 21
27 22 18
83
72
62
54
47
40
35
31
27
83
71
59
50
43
36
32
27
24
29 24 20
27 22 18
Efficiency 81.6%
Test Report
#11898.0
(Consult factory for I.E.S. data
not included within this report.)
Zonal Lumen Summary
Zone
Lumens
%Lamp
%Fixture
0-30
642
20.4
25.0
0-40
1063
33.7
41.4
0-60
1940
61.6
75.5
0-90
2569
81.6
100.0
90-180
0
0.0
0.0
0-180
2569
81.6
100.00
Total Luminarie Effieciency = 81.6%
Luminance Data
Angle
in Deg
45
55
65
0-Deg
cd/sm
2044
1845
1603
45-Deg
cd/sm
2410
2448
2525
90-Deg
cd/sm
2681
2864
3192
75
85
1292
667
2584
1334
3415
1902
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
810
807
795
776
745
709
666
614
561
497
433
364
299
233
172
115
65
20
0
45°
810
808
799
785
764
741
709
673
629
586
536
483
428
367
301
230
131
40
0
Across ⊥
810
808
802
795
783
766
744
717
686
652
610
565
518
464
397
304
166
57
0
MOUNTING INFORMATION
STG
ETG
STANDARD LAY-IN CEILING
(GRID LAY-IN)
SCREW SLOT CEILING
(SLOT-T)
SR
SHEET ROCK CEILING
(FLANGE)
FTG
STANDARD LAY-IN CEILING
(GRID LAY-IN)
Specifications and Dimensions subject to change without notice.
Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADN041913
09/20/2013 8:11:23 PM
Download