PureFX®
Project Name
Spec Type
Recessed
Notes
2’x2’
1 TT5 (40W)
Order Guide
Some combinations of product options may not be available. Consult factory for assistance with your specification.
9422
B140
–
–
–
–
Product Series & Size
Version
Configuration
Lamping
Housing
Wiring
Voltage
Ballast
PureFX 2’x2’
D1
D2
A1
A2
ST Standalone
CR Continuous Row
SMS Standalone Master/Satellite
CMS Continuous Row Master/Satellite
1 TT5 (40W)
S
N
C
T
1 1 cct
5 1 cct w/ Battery Pack
7 1 cct Dimming
1 120V
2 277V
3 347V
E Standard Ballast
Standard T-Grid
Slot T-Grid
Air Return on Standard T-Grid
Air Return on Slot T-Grid
Standard (22ga.)
New York (20ga.)
Chicago Plenum
Standard w/ Frame
Restraint
Consult website for complete list of
standard wiring options
See details on next page
Upgrades & Accessories
Consult website for ballast
manufacturer information
Cross Section
Please indicate with check mark.
Lamps Included
Lamps Included & Installed
Job Pack
Flex Whip
4-3/8"
23-13/16"
Can be mounted
to wood frame
or with hanger wire
Drywall Kit
Not available in continuous row
Side View
Wood Frame
24"
Hanger Wire
4-3/8"
Response Daylight
For details visit www.ledalite.com/response
23-11/16"
© 2010 Ledalite
Phone: 604.888.6811
Fax: 800.665.5332
Web: www.ledalite.com
Filename 9422xxxxB140.pdf Rev 2.5
PureFX®
Additional Information
Recessed
2’x2’
Mounting
1 TT5 (40W)
Integrates with most
common T-bar ceiling
types.
Photometry
Option D1 works with
9/16” and 15/16” flat
T-grid ceilings. It can also
be used with slot T-grid
ceilings, but it will not sit
flush with the bottom of
the T-bar.
Report Summary
Report #
Filename
Efficiency
Spacing Criteria
9900426
9422D1B140.ies
79%
D1 Standard T-Grid
1.3 @ 0˚ along
1.4 @ 90˚ across
Meets RP-1-04 recommendations for VDT-Normal spaces
Ceiling Types
Candela Distribution
Vertical
Angle
0
5
15
25
35
45
55
65
75
85
90
0
948
940
904
840
739
584
376
187
64
8
0
180
Horizontal Angle
22.5 45 67.5
948
945
920
879
791
600
377
199
77
12
0
948
949
958
965
860
614
390
223
105
20
0
90
Zonal
Lumens
948 948
955 956
996 1013
1044 1071
902 905
626 626
402 398
234 229
113 111
22
21
0
0
135
135
92
272
441
524
472
349
216
102
23
90
90
1100 cd
Coefficients of Utilization (%)
80
Specifications
45
45
0
45
90
0
Avg. Luminance (cd/m2)
Ceiling:
Wall:
70
50
30
10
70
70
50
30
50
50
30
10
0
0
Vertical
Angle
0 RCR
1
2
3
4
5
6
7
8
9
10
94
87
80
73
67
62
57
53
50
46
44
94
83
74
65
58
53
47
43
39
36
33
94
80
69
60
52
46
41
37
33
30
27
94
78
65
55
47
41
36
32
29
26
23
92
85
78
71
66
60
56
52
48
45
43
92
82
72
64
57
52
47
43
39
36
33
92
79
68
59
51
45
40
36
33
30
27
87
78
70
62
55
50
45
41
38
35
32
87
76
66
57
50
45
40
36
32
29
27
87
74
63
53
46
40
36
32
28
26
23
79
68
58
50
43
38
33
30
27
24
22
55
65
75
85
Based on a floor reflectance of 0.2
© 2010 Ledalite
Integrated mounting tabs
can be field-adjusted
to various T-bar ceiling
heights for fastening
directly to the T-bar grid
and/or tied-off to the
building structure.
Phone: 604.888.6811
0
Horizontal Angle
45
90
1913
1292
722
268
1985
1540
1184
670
2025
1582
1252
703
IES files for this and other
photometric options can be
downloaded online at
www.ledalite.com
Fax: 800.665.5332
Web: www.ledalite.com
D2 Slot T-Grid
Air Return
1" T-bar height
1-1/2" T-bar height
1-11/16" T-bar height
Option D2 is designed to
sit flush with slot T-grid
ceilings and some tegular
tile ceiling types.
The air return version
features slotted vents
along the sides of the
fixture. As a result, the
installation method of
the air return version
is different to the
standard version, and
the fixture cannot be
installed in continuous
rows.
Due to continuing product improvements, Ledalite reserves the right to change specifications without notice.
Housing
Die-formed, post-painted, 22 gauge cold-rolled steel (New York City
version is 20 gauge). Wire entrances are positioned on the side of
the housing to allow easy wiring access for the installer. Multiple
wire entrances are available on top or side to allow continuous row
mounting of fixtures. Optional frame restraint is available to provide
additional support to the optical frame.
Weight
Maximum 23 lbs.
Optical System
Optical assembly consists of flat acrylic panels and extruded curved
acrylic lens. A protected MesoOptics® film layer creates optimal
light distribution and high efficiency. The optical frame ends are
constructed from die-formed cold-rolled steel assembled together
with extruded aluminum profiles in a sturdy frame. The frame is
hinged to allow easy access to the inside of the fixture. Maintenance
can be performed from below the ceiling without tools. No hardware
is visible.
Ballast
Electronic. Supplied with pre-installed ballast disconnects as per
national electric codes.
Wiring
Optional flex whips are supplied in 6' lengths for 1x4, 2x2 and 2x4
fixtures. Flex connectors are supplied in 9' lengths for standard
master/satellite configurations.
Air Return
Air return option available in 2'x2' and 2'x4' sizes only. Side rails are
finished in black.
Approvals
Certified to UL & CSA Standards.
City of Chicago Approved CCEA (housing option C).
Designed to comply with NYC code requirements (Housing Option N).
Finish
Housing and Frame: Post-painted, high quality powder coat. Available
in white only.
Mounting
Fixture is compatible with most ceiling types. Integrated bend-out
tabs are provided for different T-grid heights. Optional drywall kit
is available for non-accessible ceilings. Use screws or hanger wire
(supplied by others) to secure fixture.
Filename 9422xxxxB140.pdf Rev 2.5