Catalog # Type

advertisement
NEO-RAY
DESCRIPTION
A graceful arched housing with elegantly contoured perforated lamp
diffusers. Available in (2'x2') or (2'x4') configurations, these luminaires have
no visible lamps, fasteners, hardware, or glaring reflectors, just soft,
diffused, and comfortable lighting. "The Fenestra" features totally soft light
diffusion. The precisely crafted components of the 202/204R Series provide
for high-tech appearance and a low tolerance fit. Combined, these elements
make the Neo-Ray Fenestra Series 202/204R an appropriate luminaire for
executive offices, private offices, conference rooms, corridors, open office
spaces, VDT workspaces, reception areas and dining spaces.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
A ... Construction
20-gauge steel housing. (2'x2' or
2'x4')
B ... Shielding
Perforated metal panels backed by
a white acrylic diffuser.
C ... Electrical
120, 277, 347 or Universal Voltage
electronic ballast. Fixtures and
electrical components certified to
UL and CUL standards. Note:
Fifthlight is not available for Biax
lamps.
D ... Finish
Durable, low gloss white, powder
coated acrylic finish.
Mounting
Recessed. Specify:
(ETG) 15/16" Flat Exposed T-grid,
(STG) 9/16" Screw Slot T-grid,
(SR) Sheet Rock (Flanged),
(FTG) 9/16" Flat Exposed T-grid.
Fenestra
202
204
2T8
2T5
2T5HO
Long Twin Tube
TIE WIRES
(NOT SUPPLIED BY NEO-RAY)
Recessed
A
B
C
Direct-Indirect
D
Light Distribution:
Indirect - 0.0%
Direct - 100.0%
6-1/4"
[159mm]
24" [610mm]
Notes: 1
Can be left blank or more than one option may be available, consult factory.
2
ORDERING
INFORMATION
Air Return not available for Slot T-Grid
3
Available in 2'x4' only.
4
Not all options available. Please consult your Cooper Lighting Representative for availability.
Series
202=2' x 2'
Options 1
C=Chicago Plenum
Mounting
R=Recessed
204=2' x 4'
A=Air Return2
T=Tannenbaum
Reflector
Number of Lamps
(Not included)
2=2 Lamps
Lamp Type
T83
T5
T5HO
BX40W
BX50W
Ceiling Type
ETG=15/16" Exposed
T-Grid
FTG=9/16" Exposed T-Grid
STG=Slot T-Grid
SR=Sheet Rock (Flanged)
Voltage
1=120V
4
2=277V
3=347V
U=Universal
Ballast
EB=Electronic Ballast
(Standard)
DB=Dimming Ballast
Emergency
EM=Emergency Pack (Consult Factory)
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADN041921
09/18/2013 7:26:41 PM
Fenestra 202, 204
PHOTOMETRICS
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
7
202-BX40W
(2) PF-L40W/35RS
3150 Lumens
8
9
10
Efficiency 61.0%
Candela
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
73
66
60
55
50
46
42
39
73
64
55
49
43
38
34
30
73
61
51
44
38
32
28
25
73
59
48
40
34
28
24
21
36
33
31
27 22 18
24 19 16
22 17 14
71
65
59
54
49
45
41
38
71
62
54
48
42
37
33
30
71
60
50
43
37
32
28
25
71
58
47
39
33
28
24
21
35 27 22 18
32 24 19 16
30 22 17 14
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
68
60
52
46
41
36
32
29
65
57
50
44
39
35
31
28
62
55
48
43
38
34
30
27
61
51
43
36
31
26
22
19
17
14
12
68
58
49
42
36
31
27
24
68
56
46
39
33
28
24
21
26 21 18
23 19 16
21 17 14
65
56
47
41
35
31
27
24
65
54
45
38
32
27
24
21
25 21 18
23 18 15
21 17 14
62
54
46
40
35
30
26
23
62
53
44
378
32
27
24
20
24 21 18
22 18 15
20 16 14
Angle
0
5
15
25
35
45
55
65
75
85
90
Along II
1243
1238
1184
1086
942
765
562
360
195
41
0
45°
1243
1237
1194
1116
1001
842
689
531
347
63
0
Across ⊥
1243
1241
1209
1149
1038
934
824
706
545
93
0
45°
2517
2505
2419
2260
2039
1739
1420
1128
809
151
0
Across ⊥
2517
2511
2439
2319
2105
1861
1651
1392
1091
196
0
Zonal Lumen Summary
Test Report
#NVLAP 168P138
Zone
(Consult factory for I.E.S. data
not included within this report.)
Lumens
%Lamp
%Fixture
0-30
971
15.4
25.2
0-40
1593
25.3
41.4
0-60
2868
45.5
74.6
0-90
3846
61.0
100.0
90-180
0
0.0
0.0
0-180
3846
61.0
100.0
Total Luminaire Efficiency = 61.0%
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
204-BX40W
(4) F40BX/SPX35/RS
3150 Lumens
Efficiency 62.8%
Candela
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
75
68
62
57
52
47
43
40
37
34
31
75
65
57
50
44
39
35
31
28
25
23
75
63
52
45
38
33
29
25
22
20
17
75
60
49
41
34
29
25
21
18
16
14
73
67
60
55
50
46
42
39
36
33
31
73
64
56
49
43
38
34
31
27
25
22
73
61
51
44
38
33
29
25
22
19
17
73
59
48
40
34
29
25
21
18
16
14
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
70
61
53
47
42
37
33
30
27
24
22
67
59
51
45
40
35
32
29
26
23
21
64
56
49
44
39
34
31
28
25
22
21
63
53
43
37
31
26
23
20
17
14
13
70
59
50
43
37
32
28
25
22
19
17
70
57
47
39
33
28
24
21
18
16
14
67
57
48
42
36
31
27
24
21
19
17
67
55
46
39
33
28
24
21
18
16
14
64
55
47
41
35
31
27
24
21
18
17
64
54
45
38
33
28
24
21
18
16
14
Angle
0
5
15
25
35
45
55
65
75
85
90
Along II
2517
2499
2397
2207
1922
1562
1142
722
374
89
0
Zonal Lumen Summary
Test Report
#NVLAP 168P140
Zone
(Consult factory for I.E.S. data
not included within this report.)
Lumens
%Lamp
%Fixture
0-30
1966
15.6
24.8
0-40
3234
25.7
40.8
0-60
5835
46.3
73.7
0-90
7919
62.8
100.0
90-180
0
0.0
0.0
0-90
7919
62.8
100.0
Total Luminaire Efficiency = 62.8%
MOUNTING INFORMATION
ETG
EXPOSED TEE GRID
STG
SLOT TEE GRID
SR
SHEET ROCK
Specifications and Dimensions subject to change without notice.
Neo-Ray • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADN041921
09/18/2013 7:26:41 PM
Download