COOPER LIGHTING - METALUX ® DESCRIPTION The Paralux III 1' x 1' Compact Parabolic brings together rugged construction and compact fluorescent lamp sources (PL, Curvalume or Biaxial) with an efficient, aluminum parabolic louver assembly for light control and design aesthetics. Catalog # The 1' x 1' Compact Parabolic is an excellent low brightness, decor pleasing luminaire for accent, corridor, foyer and small office lighting applications. The 1' x 1' is an ideal complement to any standard parabolic installation in plaster, drywall, or ceiling tile. Comments Type Project Date Prepared by SPECIFICATION FEATURES A…Construction B…Electrical* Nominal 7" deep housing, die formed code gauge, prime cold rolled steel. Formed housing stiffeners for added strength. Captive lampholder brackets. Fully enclosed lampholder wiring permits easy lamp replacement. Dual purpose, contoured reflectors for each lamp combination provides optimum lighting distribution and conceals wiring and ballast compartments. Snap -in access plate is located on back of housing for wiring convenience. End plates, securely attached with tabs and screws. Heavy duty adjustable mounting brackets are preset at the factory and allow use of 1/2" EMT conduit, lathing channels or bar hangers for installation. Ballast are CBM/ETL Class “P” and positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. Suitable for damp locations. E…Louver 3" deep high performance louver technology. Die formed of semi-specular, low iridescent, vertical grain, anodized aluminum. (Standard) Finish is anodic oxide coating. Accurate parabolic cell are held in place with interlocking feature. True cut mitered corners, integrated light seal around entire perimeter of louver. Louver retained by torsion springs and can be easily removed. Louver Trim is attractively styled with mitered aluminum corners and is available with white (standard) or satin aluminum (optional) finish. C…Finish Painted after fabrication. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibitor. Lighting grade, baked white finish. D…Ref lector Finish Internal reflector surface, electrostatically applied baked white polyester powder finish. Multistage cleaning cycle, iron phosphate coating with rust inhibitor. Conveyorized application and baking time accurately controlled at an elevated temperature. A B C D E P3 2OC16 3OC16 2BX18 3BX18 4 or 9 Cell 4 OR 9 CELL SEMI-SPECULAR LOUVER 1' X 1', 2 OR 3 LAMP RAPID START 1' X 1', 2 OR 3 LAMP PRE-HEAT 7-1/8" [181mm] Paralux III Compact Parabolic ENERGY DATA Input Watts: EB Ballast & STD Lamps 2OC16 (33), 2BX18 (67) ES Ballast & STD Lamps 2OC16 (43) STD Ballast & STD Lamps 2BX18 (82) 12-7/8" [327mm] 15-1/2" [394mm] MOUNTING DATA LAMP CONFIGURATIONS 7/8" [22mm] K.O. (1) Access Plate X 12-7/8" [327mm] 12" [305mm] X=1-1/2" [38mm] 12" [305mm] 7-1/8" [181mm] 4-1/8" [105mm] Hanging Brackets Heavy duty adjustable mounting brackets Trim Attractively styled mitered aluminum fixture trim. (White Finish standard or optional Satin Aluminum Finish) COOPER LIGHTING 12" [305mm] 7-1/8" [181mm] 12-7/8" [327mm] 15-1/2" [394mm] 12-7/8" [327mm] 15-1/2" [394mm] 12" [305mm] 12" [305mm] 7-1/8" [181mm] LER = FP-34 Catalog Number: P3-2BX18S22I-RS Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = 7.06 *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. 7-1/8" [181mm] 12-7/8" [327mm] 15-1/2" [394mm] Luminaire Efficacy Rating LER = FP-35 Catalog Number: P3-2OC16S22I Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = 6.86 12-7/8" [327mm] 15-1/2" [394mm] LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF020539 P3 PHOTOMETRICS P3-2BX18S22I-RS Standard Ballast F18BX/SPX35/RS lamps 1250 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.4 x mounting height. Efficiency = 62.5% Test Report: P32BX18S22IRS.IES LER = FP-34 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $7.06 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 686 683 667 645 616 582 546 506 457 399 336 253 154 56 18 9 5 2 0 Across ⊥ 686 693 714 733 750 755 737 664 483 312 261 263 203 44 17 9 5 2 0 45° 686 686 688 689 686 675 651 622 563 447 291 194 135 49 19 10 5 3 0 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 74 68 62 56 51 46 42 38 34 30 28 74 66 59 52 46 41 37 33 29 26 23 74 64 56 49 43 39 33 29 26 22 20 73 68 64 60 55 51 48 44 41 37 35 73 66 61 55 50 45 41 37 34 30 27 73 65 58 52 46 41 37 33 29 26 23 73 63 55 49 43 38 33 29 26 22 20 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180 Lumens 581 967 1490 1562 14562 %Lamp 23.2 38.7 59.6 62.5 62.5 Candela Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 646 645 634 618 594 563 524 477 429 379 321 246 160 52 17 9 4 2 0 Across ⊥ 646 656 671 673 676 639 583 542 516 418 315 247 187 44 16 8 4 2 0 45° 646 652 656 654 643 628 588 527 466 413 336 228 138 47 18 9 5 2 0 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 74 70 66 61 57 53 49 45 42 38 36 P3-2OC16S22I Standard Ballast FB016/31K lamps 1250 Lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.3 x mounting height. Efficiency = 58.5% Test Report: P320C16S22IRS.IES LER = FP-35 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $6.86 Candela %Fixture 37.2 61.9 95.4 100.0 100.0 20% 50% 50 30 10 30% 50 30 10 50 69 64 59 53 49 44 40 36 33 29 27 67 62 57 52 47 43 39 35 32 29 26 64 59 55 50 46 42 38 35 31 28 26 69 63 56 50 45 40 36 32 29 25 23 69 61 54 48 42 37 33 29 26 22 20 67 60 55 49 44 39 35 32 28 25 22 67 59 53 47 42 37 33 29 25 22 20 10% 30 10 64 58 53 48 43 39 35 31 28 25 22 64 58 52 46 41 36 33 29 25 22 20 0% 0 63 56 51 45 40 35 31 28 24 21 19 Typical VCP Percentages Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Height Along 8.5’ 10.0’ 74 66 80 73 81 76 83 78 84 79 Height Across 8.5’ 10.0’ 77 69 82 75 83 78 85 79 84 80 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 70 65 61 57 53 49 45 42 38 35 33 70 63 58 52 47 43 38 35 31 28 25 70 62 55 49 43 38 34 30 27 23 21 70 60 52 46 40 35 31 27 24 20 18 68 64 60 56 52 48 44 41 38 35 32 68 62 57 51 46 42 38 34 31 28 25 68 60 54 48 43 38 34 30 26 23 21 20% 68 59 52 45 40 35 31 27 23 20 18 50% 50 30 10 30% 50 30 10 50 65 60 55 50 45 41 37 33 30 27 25 62 57 53 48 44 40 36 33 29 26 24 60 55 51 47 43 39 35 32 29 26 24 65 58 52 47 42 37 33 30 26 23 21 65 57 50 44 39 34 30 27 23 20 18 62 56 51 46 41 36 33 29 26 23 20 62 55 49 44 39 34 30 27 23 20 18 Zonal Lumen Summary Typical VCP Percentages Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens 530 859 1391 1462 1462 %Lamp 21.2 34.4 55.7 58.5 58.5 %Fixture 36.2 58.7 95.1 100.0 100.0 10% 30 10 Height Along 8.5’ 10.0’ 75 67 80 74 82 77 84 79 85 81 60 55 50 45 40 36 32 29 26 23 20 60 54 48 43 38 34 30 26 23 20 18 0% 0 58 53 47 42 37 33 29 25 22 19 17 Height Across 8.5’ 10.0’ 75 68 80 75 82 78 87 79 85 81 ORDERING INFORMATION SAMPLE NUMBER: P3-2BX18S22I-RS-120V-EB81-U Series P3=Paralux III Number of Lamps 2=2 Lamps 3=3 Lamps Ballast Start Type PH=Pre-Heat, NPF PH-HPF=Pre-Heat, HPF RS=Rapid Start Wattage OC16=16W T8 BX18=18W Biax PH BX18=18W Biax RS Voltage (1) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 Louver Color S=Silver Options GL=Single Element Fuse GM=Double Element Fuse Ballast Type (1) Blank=Standard Magnetic Ballast (Biax & 20W) EB8 = T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 Options Packaging RIF1=Radio Interference U=Unit Pack Suppressor NDF=Natural Aluminum Trim 20GA/REP=20 Gauge Riveted Endplates. For use in New York City. RLS=Rotor-Lock Socket (T8 Lamps Only) Cell Configuration 22=2 Rows of 2, 4 Cell (1' x 1') 33=3 Rows of 3, 9 Cell (1' x 1') Louver Finish I=Semi-Specular/Haze (Low Iridescent) Standard MI=Specular/Mirrored (Low Iridescent) SHIPPING INFORMATION Catalog No. NOTES: (1) Products also available in non-US voltages and frequencies for international markets. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Wt. P3-2TT13S331-PH P3-2TT13S221-PH P3-2BX18S331-PH P3-2BX18S2211-PH P3-2BX18S331-RS P3-2BX18S22I-RS P3-3BX18S33I-PH P3-3BX18S22I-PH P3-3BX18S33I-RS P3-3BX18S22I-RS 8 lbs. 8 lbs. 8 lbs. 8 lbs. 8 lbs. 8 lbs. 15 lbs. 15 lbs. 15 lbs. 15 lbs. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 5/10 ADF020539