Metalux D ES C R IPTION The Paralux III Tannenbaum louver offers designers an exciting new appearance forlow brightness recessed applications. The luminaire incorporates a unique European louver design featuring low iridescent specular and Tannenbaum aluminum optical surfaces. This louver integrates into the Paralux III 4-3/4" deep para-contoured housing for optimum performance. The Paralux III series is compatible with all of today’s popular ceiling systems and is available with a number of options and accessories to application versatility. The Paralux III Tannenbaum louver is a great visual alternative to traditional recessed luminaires and provides efficient, low glare ambient lighting appropriate for most commercial interior environments. Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S C on s t r u c t i o n E le ctrica l* * H inging/Latching 4-3/4" deep, para-contoured housing, die formed code gauge, prime cold rolled steel. Die embossed housing has full length die formed stiffeners for added strength. Contoured ballast/ wireway cover is easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy end plates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. End plates have integral Grid-Lock feature for safety and convenience. Ballasts are CBM/ETL Class “P” and are positively secured. 2G11 base lampholders have doubleedge wiping action pressure lock contacts with vertically oriented lamp support clips. UL/CUL listed. Suitable for damp locations. Positive spring loaded, self locking, steel latches. Safety lock T-hinges allow hinging and latching from either side. F in ish Lighting grade, baked white enamel finish. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibition. Louver Die formed of low iridescent anodized specular and Tannenbaum aluminum. Finish is anodic oxide coating. Accurate precision contours are held in place with interlocking feature. Trus cut mitered corners. Black reveal with integral mechanical light seal around entire perimeter of louver. Louver protected from construction contaminants by poly cover. 2EP3GAX 2U6T8 2U1-5/8, 3U1-5/8 2BX40, 3BX40 18 Cell 4-3/4" [121mm] 2' X 2' PARABOLIC 2 OR 3 LAMP TANNENBAUM LOUVER 23-3/4" [603mm] Paralux III Recessed Static or Air Supply Troffer MOUNTING D A TA 2 LAMP 7/8" [22mm] K.O. (2) L A MP CONF IGURA T IONS Access Plate 7/8" [22mm] K.O. (2) 3 LAMP Access Plate 7/8" [22mm] (2) 7/8" [22mm] K.O. (4) 3 LAMP – 18 CELL 4-3/4" [121mm] 2-5/8" [67mm] 7" 7" [178mm] [178mm] 23-3/4" [603mm] 23-3/4" [603mm] 23-3/4" [603mm] ENERGY DATA 2 LAMP – 18 CELL 4-3/4" [121mm] 3-5/8" [93mm] 1-3/4" [45mm] 1-3/4" [45mm] 6-7/8" [176mm] 24" [608mm] 2-5/8" [67mm] X=1-5/8" [41mm] 6-7/8" [176mm] 24" [608mm] 3 LAMP – 18 CELL 23-3/4" [603mm] 2 LAMP – 18 CELL 2 LAMP – 18 CELL 4-3/4" [121mm] 4-3/4" [121mm] X 5-3/8" X 5-3/8" X [137mm] [137mm] 2-5/8" [67mm] X=6" [152mm] 23-3/4" [603mm] 10-1/2" [267mm] 2-5/8" [67mm] 3-5/8" [93mm] 4-3/4" [121mm] X 4-5/8" [117mm] 2-5/8" [67mm] X=1-5/8" [41mm] X 23-3/4" [603mm] X 8-7/8" X [225mm] 23-3/4" [603mm] C EILING C OM PA TIB IL I T Y G Grid/Lay-in Standard G Concealed T G Slot Grid F Aluminum Flange Trim With Supporting Swing Gates MZ Modular Trim With Supporting Swing Gates Ceiling Type Trim Type Exposed Grid Concealed T Slot Grid Flange Concealed “T” or ”Z“ Metal Pan G G G F MZ MZ (Verify compatibility/ consult factory.) Input Watts: EB Ballast & STD Lamps 2BX40 (67), 3BX40 (110), 2U6T8 (61), 2U1-5/8 (61), 3U1-5/8 (91) Luminaire Efficacy Rating LER = FP-55 Catalog Number: 2EP3GAX3BX40ST36MI Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.36 **Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. ADF090228 2013-02-05 08:21:51 2 E P 3 GAX T ANNE NB AUM PH OTOM ETR IC S Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 2EP3GX3BX40ST36MI Electronic Ballast Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 75 70 65 60 55 51 48 44 41 39 36 75 67 60 54 49 44 40 37 34 31 29 75 65 57 50 44 39 35 32 29 26 24 75 63 54 46 40 35 31 28 25 23 21 73 68 63 58 54 50 46 43 40 38 36 73 66 59 53 48 43 39 36 33 31 28 73 64 56 49 43 39 35 31 28 26 24 73 62 53 46 40 35 31 28 25 23 21 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 70 63 57 51 46 42 38 35 32 30 28 67 61 55 50 45 41 37 34 32 29 27 64 59 53 48 44 40 36 33 31 29 27 63 56 48 42 37 33 29 26 24 21 19 70 62 54 48 43 38 34 31 28 26 24 70 60 52 45 39 35 31 28 25 23 21 67 60 53 47 42 37 34 30 28 25 23 67 58 51 44 39 35 31 28 25 23 21 F40BX/SPX35/RS Lamps 3150 Lumens Zonal Lumen Summary Typical VCP Percentages Spacing criterion: (II) 1.1 x mounting height, (⊥) 1.6 x mounting height Zone 0-30 0-40 0-60 0-90 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 Efficiency 62.8% 0-180 Lumens %Lamp %Fixture 2116 3600 5449 5936 5936 22.4 38.1 57.7 62.8 62.8 35.6 60.6 91.8 100.0 100.0 60 x 60 Height Along 8.5’ 10.0’ 50 52 50 50 45 44 57 57 50 49 64 58 51 46 41 37 33 30 27 25 23 64 57 50 44 38 34 31 27 25 22 21 Height Across 8.5’ 10.0’ 76 75 75 73 78 76 73 72 75 73 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 2597 2517 2396 2279 2133 1988 1838 1674 1512 1334 1142 943 746 560 414 275 158 59 0 Across ⊥ 2597 2617 2663 2770 2910 3059 3275 3122 2350 987 580 405 272 46 21 12 6 0 0 45° 2597 2561 2504 2455 2427 2401 2328 2276 2206 1903 1368 658 389 270 175 110 60 20 0 Test Report: 2EP3GX3BX40ST36MI.IES LER = FP-55 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $4.36 ORDER ING INFOR M A TION SAMPLE NUMBER: 2EP3GAX-3BX40ST36MI-120V-EB51-U Rating Blank= Standard ATW-SW4= Chicago Rated HR=Heat Removal (1) Wattage (Length) BX40=40W Biax (24") U6T8=32W T8 (24") U15/8=31W T8 (24") Width 2=2' Width Louver Color/Type ST=Silver Tannenbaum EP=Paralux Louver 3=3" Louver Depth Trim Type G=Grid/Lay-in (Standard) G=Concealed T/Slot Grid (7) F=Aluminum Flange Trim (8) MZ=Modular Trim AX=Air Supply Floating Louver X=Blank Side/Floating Louver Non-Air Supply (Omit A) AVX=Air Supply Floating Louver with Directional Air Vane (Add V) Voltage (4) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (5) Number of Lamps 2=2 Lamps 3=3 Lamps (3) Cell Configuration 36=3 Rows of 6, 18 Cell Louver Finish MI=Specular/Mirrored (Low Iridescent) (Silver Only) Options GL=Single Element Fuse GM=Double Element Fuse WTR=White Reveal Lamps=Lamps Installed (refer to lamp ordering options) Flex=Flex Installed (Reference Flex ordering information) EL=Emergency Installed (6) Option – Aluminum Flange Trim (8) Blank=SW (Single White) Type Color ‘S’ Single ‘N’ Natural ‘R’ In Row ‘W’ White ‘E’ End of Row Ballast Type EB8 = T8 Electronic Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Start. Total Harmonic Distortion < 10% No. of High Ballast Factor >1.15 Ballast 1, 2 or 3 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB5 =T5 Biax Electronic Instant Start. (9) Total Harmonic Distortion < 20% No. of Ballast 1, 2 or 3 TEB5 =T5 Biax Electronic Instant Start (9) Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 ER5 = T5 Biax Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 Options PAF=Painted After Fabrication REP=Riveted Endplates Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton ACCESSORIES EQ-CLIP-U=T-BAR Safety Earthquake Clips(2) (1) (2) NOTES: Integral end plate grid lock feature not available in heat removal. An EQ Grid Clip is recommended for all 9/16" ceiling systems. Four required per (3) (4) (5) fixture. Standard off-center ballast on 3-lamp fixtures. Products also available in non-US voltages and frequencies for international markets. Not available (6) when specifying emergencies, voltage must be specific. Fixtures equipped with “EL” option may require a 5-1/2" housing depth. If installing in field, must (7) (8) use low profile battery pack. Louver is recessed by 5/16" in Concealed T or Slot Grid T. Specify row configuration, type in catalog number when ordering (9) complete fixture. Not available in UNV voltages. Must specify voltage. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. SH IP P ING D A T A Catalog No. 2EP3GAX-2U1-5/8ST36MI 2EP3GAX-3U1-5/8ST36MI 2EP3GAX-2U6T8ST36MI 2EP3GAX-2BX40ST36MI 2EP3GAX-3BX40ST36MI Wt. 28 lbs. 28 lbs. 28 lbs. 28 lbs. 28 lbs. ADF090228 2013-02-05 08:21:51