Type II RetroFit Installation Instructions - page 1 of 2

Class E3R -

1, 2, or 3 lamp fluorescent recessed retrofit

2’x2’ / 2’x4’

WARNINGS

1). WARNING! Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing.

2). WARNING! - Risk of Fire/Electric Shock. If not qualified, consult an electrician.

3). WARNING! – Risk of fire or electric shock. Luminaires wiring, ballasts, or other electrical parts may be damaged when drilling for installation of reflector kit hardware. Check for enclosed wiring and components.

NOTES

1). NOTE!- Fixture in compliance with UL1598B

2.) NOTE!- Luminaires employing more than one ballast must be spaced more than 25 mm

(1 inch) end to end or 100 mm (4 inch) side to side.

3). NOTE! - Reflector kit installation requires knowledge of fluorescent lighting systems and electrical systems. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings.

4). NOTE! - This product must be installed in accordance with the applicable installation code by a certified electrician, familiar with the construction and operation of the product and hazards involved.

5). NOTE! - Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installation. Do not leave any other open holes in an enclosure of wiring or electrical components.

6). NOTE! - To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or any sharp objects.

7). NOTE! - DRY LOCATIONS ONLY

8). NOTE! - Disconnect all power before proceeding.

9). NOTE! - Remove all internal components from existing luminaire to be retrofitted - louvers, lamps, ballast cover, ballast, socket tracks, lamp holders, and reflector from the housing.

Please dispose of lamps and ballasts properly, and recycle the other components, if possible.

1. Unpack Class E3R Retrofit components.

2. Affix ballast to the housing at least 5” from center of fixture and 4” from power line input location.

5” min.

Ballast / Bracket Assembly Lens / Door

4”

3. Secure ballast with screws.

Reflector

4. Prepare to install end brackets by sliding them into the ends of the housing.

Bottom flange on end brackets should sit above ceiling grid and below housing edge (sandwiched).

NOTE!- Luminaires employing more than one ballast must be spaced more than 25 mm

(1 inch) end to end or 100 mm (4 inch) side to side.

5. Secure the end brackets with the two captive self-drilling screws at each end.

6. Connect power input to ballast using supplied quick-connectors. Push stripped wire leads from power input into open end of quick-connector.

Ensure that the end bracket is pushed all the way against the housing wall before securing with screws.

18001 East Colfax Ave. Aurora, CO 80011

Ph. (303) 393-1522 Fax (303) 393-1477

ADE120787 rev 052312

Type II RetroFit Installation Instructions - page 2 of 2

Class E3R -

1, 2, or 3 lamp fluorescent recessed retrofit

2’x2’ / 2’x4’

8. Begin reflector installation by placing the reflector into the housing.

7. If housing is deeper than 3.5” it may be necessecary to extend end brackets. To adjust height, remove both screws and shift socket tray to top hole and replace screws.

2

1

3

9. Ensure reflector is properly seated in tabs and is not interfering with ballast prior to securing with screws Install reflector using locking tabs and pre-installed screws at each end.

10. Install door. Gently insert door tabs into end bracket slots and slide door assembly to edge of fixture. Ensure door flanges are fully inserted into bracket slot.

1

2

11. Install lamps.

12. Close Door. Ensure clips have engaged and are locking door in place.

18001 East Colfax Ave. Aurora, CO 80011

Ph. (303) 393-1522 Fax (303) 393-1477

ADE120787 rev 052312