Catalog # Type

advertisement
CORELITE
DESCRIPTION
The Corelite Class R2R Retrofit is designed to replace the core "lighting
engine" of dated and inefficient recessed luminaires, while leaving the
existing metal luminaire body intact. The total watts per luminaire can be
reduced between 30 and 40 percent while improving the overall lighting
quality and visual character of the interior space. The Class R2R is extremely
low in profile with a 3" overall height, allowing for retrofit of shallow 3"
lensed troffers. In addition to the energy cost reduction and improved
lighting conditions, the Class R2R's 80%+ luminaire efficiency meets the
requirements of many major rebate programs across the US.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
Construction
Three-piece retrofit assembly
consists of a ballast/bracket
assembly, reflector and lens.
Ballast/bracket assembly and
reflector each have captive
zinc-plated self-drilling hardware.
Mounting brackets are pre-paint
white 20-gauge die-formed steel.
Reflector is one piece die-formed
aluminum with a matte white
powder coat painted finish. Ballast
is pre-wired to factory installed
sockets on each mounting bracket
with the ballast/bracket assembly.
3" low-profile assembly will retrofit
into both parabolics and troffers.
Finish
Reflector is matte white powder
coat painted finish. Ballast brackets
are pre-paint white with white
semi-gloss finish.
Electrical
Ballast is fully tested and pre-wired
to factory installed sockets within
the ballast/bracket assembly, and
comes with captive self-drilling
hardware and integral quick
disconnects. T5/T5HO fixtures use
UL listed Class P, T5/T5HO
program rapid start universal
voltage electronic ballasts, with
pre-installed quick disconnect.
Standard Ballast Factor of 1.0 and
Power Factor of 98%.
Mounting
First, existing lamps, reflectors,
lenses, ballast covers, ballast and
socket trays must be removed
from existing luminaire. Next, the
ballast/bracket assembly is
installed by first mounting the
ballast to the top of the existing
luminaire, then by attaching the
mounting brackets. The reflector
then mounts to the ballast/bracket
assembly, and finally lamps and
lenses are installed.
Shielding
Luminaire lens is UV resistant
acrylic with an optically designed
prism structure, which diffuses
lamp image and provides high
light transmission and luminaire
efficiency (80%+).
NOTE: Fit Compatibility
Retrofit kit fits most troffers. The
end-user is responsible for
verifying fit. Therefore, a sample
kit is highly recommended.
CLASS R2R
Retrofit
Lensed
1T5
1T5HO
2'x4' Recessed Retrofit
Existing Recessed Luminiare*
3-1/8”
[79mm]
min
3”
[76mm]
24”
[610mm]
ORDERING INFORMATION
Sample Number: R2R-WL-1T5-1C-UNV-24-T1
Series
R2R=Class R2R
Retrofit
Reflector
W=White
Shielding
L=Linear Prismatic Lens
Number of Lamps
1=1 Lamp
Lamp Type
N5=T5 Normal Output
T5=T5 High Output
Number of
Circuits
1=1 Circuit
1
Wiring 1
B=Battery Pack
Voltage 1
120=120V
C=Standard Circuit
D=Dimming / Step
Dimming
277=277V
347=347V
E=Emergency
T=Nightlight
UNV=Universal
(120V-277V)
Size
24=2' x 4'
Options 1
SD=Step Dimming
Ceiling Type
T1=1" Grid2
Y=Daylight
Notes: 1
2
Not all options available. Please consult your Cooper Lighting Representative for
availability.
Ceiling Type T1 is for flush ceilings only. Consult factory for all other ceiling types.
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADE100071
09/26/2012 1:53:21 PM
Corelite
PHOTOMETRICS
Candela
Coefficients of Utilization
rc
rw
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30
RCR
0
1
2
3
4
5
6
7
8
R2R-WL-1N5 2x4
(1) F28/835
2750 Lumens
9
10
108 108 108 108
97
88
92
80
88
73
84
67
80
73
67
69
61
54
61
53
46
62
57
53
50
46
49
44
40
37
34
40
36
32
29
27
Along II
1546
1544
o
45
1546
1547
Across I
1546
1539
10
15
1524
1486
1532
1502
1532
1511
73
59
20
25
1430
1358
1460
1404
1482
1439
49
42
36
31
30
35
40
1273
1173
1064
1335
1255
1166
1389
1330
1265
45
50
55
60
65
70
75
80
950
832
713
596
480
368
262
163
1071
972
872
768
667
574
486
379
1195
1120
1043
963
886
807
708
556
85
90
76
0
197
0
293
0
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
Angle
0
5
101 101 101
97
97
97
83
69
80
65
83
30
77
93
77
93
75
91
86
74
93
79
65
57
51
46
59
51
44
39
53
45
39
34
71
62
55
49
67
57
49
43
63
52
44
38
69
60
53
48
65
55
48
42
62
51
44
38
42
38
35
33
35
31
29
26
30
26
24
22
45
41
37
34
32
38
34
31
28
26
33
29
26
24
21
43
39
36
33
31
38
34
30
28
25
33
29
26
24
21
20%
10
106 106 106 106
95 90 86 83
55
46
39
85
77
71
65
78
68
60
53
71
60
52
45
66
54
46
39
34
30
27
24
22
60
55
52
48
45
48
43
40
36
34
40
36
32
29
26
34
30
27
24
22
27
24
22
20
Efficiency 90.9%
Test Report
#P30230
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
Lumens
1218
2003
3613
%Lamp
22.1
36.4
65.7
%Fixture
24.3
40.0
72.2
Angle
in Deg
45
55
0-Deg
cd/sm
1806
1671
45-Deg
cd/sm
2036
2044
90-Deg
cd/sm
2272
2444
0-90
40-90
60-90
5002
2999
1389
90.9
54.5
25.2
100.0
60.0
27.8
65
75
85
1527
1361
1172
2122
2524
3038
2818
3677
4519
90-180
0-180
0
5002
0
90.9
0
100.0
FIT COMPATIBILITY GUIDELINES
The Class R2R is an extremely low profile retrofit design and will fit the majority of existing lensed troffers and louvered parabolics. However, Corelite cannot guarantee
fit with every existing luminaire – fit confirmation is therefore the responsibility of the end-user. For best results, contact your local representative for a sample or trial
installation prior to ordering.
CROSS SECTION
END SECTION
24”
[610mm]
Typical Existing
Recessed Housing
Various Housing
Mounting
Bracket
3”
[76mm]
3”
[76mm]
2-1/4”
[57mm]
22-1/4”
[565mm]
23-7/8”
[606mm]
1”
[26mm]
Ballast-Bracket
Assembly
Existing Luminaire
Lamps
(Optional)
Lens
Specifications and Dimensions subject to change without notice.
Corelite • 18001 E. Colfax Ave. • Aurora, CO 80011 • 303.393.1522 • FAX 303.393.1477