INSTALLATION INSTRUCTIONS VH/VAH/VCH Hibay

advertisement
INSTALLATION INSTRUCTIONS
VH/VAH/VCH Hibay
File: 5900461-000.doc Rev. 0 05-11-15
These instructions may not provide directions to cover every variation and detail. To obtain additional information,
consult the applicable electrical codes or contact the factory directly for assistance before attempting anything with
uncertainty. All wiring should be performed by a qualified electrician.
WARNING: To avoid electrical shock, TURN POWER SUPPLY OFF before installing or servicing this unit.
NOTE:
All “-T” models are supplied with Tri-tap ballast voltage (120 / 277 / 347) and are factory pre-wired
and tested to 347Volt. If 120V or 277V is required, open wiring compartment and change voltage lead from ballast.
All other models (ex. “-2” for 208 volt) are ordered, tested and supplied with the desired voltage pre-wired.
Installing EHS Reflector to Ballast Housing:
Install Yoke Bracket** to
housing bottom with (4)
screws provided through
keyhole slots
Attach Reflector Straps into outer slots
in reflector as shown and rotate up to
lock in position (x2)
Attach Reflector Straps onto
Yoke Bracket with the (2)
screws provided and adjust
to desired setting
** Note: some models may have yoke factory installed
Installing EAS Acrylic Reflector to Ballast Housing:
Install Yoke Bracket** to
housing bottom with (4)
screws provided through
keyhole slots
Attach Reflector Straps into outer slots
in reflector as shown and rotate up to
lock in position (x2)
Attach Reflector Straps onto
Yoke Bracket with the (2)
screws provided and adjust
to desired setting
** Note: some models may have yoke factory installed
KEENE is a Product Group of Canlyte, 455 Dobbie Drive, P.O. Box 874, Cambridge, ON. N1R 5W4 tel: 519-623-8820 fax: 519-623-4435 QF4010 rev. 3 02-09-18
Page 1 of 2
INSTALLATION INSTRUCTIONS - VH/VAH/VCH Hibay
File: 5900461-000.doc Rev. 0 05-11-15
Installing Ballast Housing: Hook & Cord Mount
Fig 1
Fig 1.
Fig 2.
Fig 3.
Fig 4.
Fig 2
Fig 3
Fig 4
Hang ballast housing by cast hook onto suitable rigid mounting mechanism such as eyebolt or power hook.
Ensure safety screw on hook is securely tightened to prevent accidental removal.
Make electrical connections to power supply in electrical junction box or by securing the (optional) twist lock
NEMA rated plug into mating receptacle.
If required, remove wire access plate and change the voltage tap from ballast to the required voltage. Tri-tap
fixtures (“-T” = 120/277/347 volt) are factory pre-wired and tested to 347 volt. If fixtures were ordered as a
specific voltage, ex. “-1” for 120 volt, then this step is not necessary.
VALUE HIBAY - REFLECTOR STRAP POSITIONING CHART
PART 1
VH SERIES
Distribution pattern / Strap Position
Catalogue No.
VH250LXK-T
VH400LXK-T
VH400MAK-T
Lamp
250HPS CLEAR
400HPS CLEAR
400MA CLEAR
Reflector Type
15” DIFFUSE ALUMINUM
15” DIFFUSE ALUMINUM
15” DIFFUSE ALUMINUM
Narrow
10
8
--
Lamp
250HPS COATED
400HPS COATED
400MH COATED
Reflector Type
19” ACRYLIC
19” ACRYLIC
19” ACRYLIC
Narrow
1
1
Lamp
250HPS COATED
400HPS COATED
400MH COATED
Reflector Type
19” ACRYLIC
19” ACRYLIC
19” ACRYLIC
Narrow
1
1
Medium
7
6
9
Wide
4
2
6
VAH Series
Distribution pattern / Strap Position
Catalogue No.
VAH250LXK-T
VAH400LXK-T
VAH400MAK-T
Medium
3
3
Wide
6
1
6
VCH Series
Distribution pattern / Strap Position
Catalogue No.
VCH250LXK-T
VCH400LXK-T
VCH400MAK-T
Medium
3
3
Wide
6
1
6
www.canlyte.com
KEENE is a Product Group of Canlyte, 455 Dobbie Drive, P.O. Box 874, Cambridge, ON. N1R 5W4 tel: 519-623-8820 fax: 519-623-4435 QF4010 rev. 3 02-09-18
Page 2 of 2