COOPER LIGHTING - LUMARK Catalog # Type

advertisement
COOPER LIGHTING - LUMARK ®
DESCRIPTION
The Lumark Quadra-Lume is perfect for applications which call for
reliable, affordable illumination with minimal maintenance. Quadra-Lume
is designed for easy installation on main T-bars or can be hung by wires
in lay-in ceilings with 2' x 2' tiles. U.L. listed and CSA certified.
The Quadra-Lume provides minimum surface brightness, excellent
uniformity and gentle diffusion. It is ideal for use in department stores,
banks, auto showrooms, schools, libraries, office buildings and
auditoriums.
Type
Catalog #
Project
Date
Comments
Prepared by
S P E C I F I C AT I O N F E AT U R E S
Construction
Optics
HOUSING: Die-formed, heavy-duty
housing is made of cold-rolled
steel and finished in highly
reflective white polyester powder
coat. Stamped steel ballast
mounting bracket is integral part of
housing. DOOR FRAME: Dieformed, heavy-gauge steel frame
can be hinged and latched from
either side. Stamped steel retaining
clips assure flush fit of lens with
frame.
REFLECTOR: Die-formed steel
reflector has removable panels for
easy ballast access from below.
LENS: Gasketed flat prismatic
acrylic or C73 glass lens.
QF
QUADRA-LUME
High Pressure Sodium
Pulse Start Metal Halide
Metal Halide
RECESSED COMMERCIAL
E N E R G Y D ATA
High Reactance Ballast Input Watts
150W HPS HPF (190 Watts)
DIMENSIONS
CWI Ballast Input Watts
175W MH HPF (223 Watts)
250W HPS HPF (300 Watts)
250W MH HPF (300 Watts)
400W HPS HPF (465 Watts)
400W MH HPF (475 Watts)
S H I P P I N G D ATA
Approximate Net Weight:
39 lbs. (18 kgs.)
C
ER
TEM
S
YS
D
23-7/8"
[606mm]
CWA Ballast Input Watts
175W MP HPF (198 Watts) G
200W MP HPF (227 Watts) G
250W MP HPF (283 Watts) G
320W MP HPF (365 Watts) G
350W MP HPF (400 Watts) G
400W MP HPF (452 Watts) G
400W HPS HPF (465 Watts)
S
11"
[280mm]
TIFIE
ADH081457 pc
2010-11-09 12:24:27
QF - QUADRA-LUME
P H OTO M E T R I C S
90
30
60
90
60
30
120
150
CP/100
MHQF-GL-C73-400
400-Watt Metal Halide
40,000-Lumen Coated Lamp
Coefficients Of Utilization
Candlepower
Effective floor cavity reflectance
20%
rc
80%
rw
70
50
30
RCR
0
89
89
89
70
70%
50
30
50%
50
30
30%
50
30
87
87
87
83
83
79
79
1
82
79
76
80
77
75
74
72
71
70
2
76
70
66
74
69
65
66
63
64
61
3
70
63
57
68
62
56
59
55
57
54
4
64
56
50
63
55
50
54
49
52
48
5
60
51
45
58
50
44
49
43
47
43
6
55
46
40
54
46
40
44
39
43
38
7
52
42
36
50
42
36
40
35
39
35
8
48
39
33
47
38
33
37
32
36
32
9
45
36
30
44
35
30
34
29
34
29
10
42
33
27
41
33
27
32
27
31
27
Degree
0
5
15
25
35
45
55
65
75
85
CP
12888
12878
12798
12165
10322
7253
3975
2097
1121
437
F L U S H M O U N T I N G T R I M ( F T B, F TW, F TA )
Heavy-gauge extruded
aluminum combination fixture
trim and plaster frame. Neatly
finishes out any 2’ x 2’ recessed
installation.
Aluminum fixture trim secured to
ceiling support system with screws.
24” [610mm] sq.
25 1/8’ [638mm] sq. min. opening required
26” [660mm] sq.
ORDERING INFORMATION
Sample Number: MHQF-GS-C73-400-120V-Q
Lamp Type
MP=Pulse Start Metal Halide1
Door Frame
GS=Flat Steel
Lamp Wattage
MP
120V
MH=Metal Halide1, 2
HP=High Pressure Sodium
GO/GAS=Flat Aluminum
GMXF=Flat, Non-Floating
Aluminum Door Frame
70=70W
100=100W
208V
Series
QF=Quadra-Lume w/ Flat Lens
175=175W
200=200W
GMXR=3/8'' Regressed
Non-Floating Aluminum
Door Frame
350=350W
400=400W
A/GL=Acrylic Lens w/ Glass Overlay
ACTF.140=Acrituf, 0.140'' Thick
MH
C73=Prismatic Tempered Glass
Lens
PL=Polycarbonate Refractor
Voltage
5
240V
277V
347V
250=250W
320=320W
Lens Type 1
A=Acrylic Lens
ACTF.187=Acrituf, 0.187'' Thick
H8246=Halophone 82463
4
2
175=175W
250=250W
400=400W
HP
QB=Quiet Ballast6
F1=Single Fuse (120, 277 or 347V only)
F2=Double Fuse (208, 240 or 480V only)
SCF=3' Aircraft Safety Cable secures
Housing to Ceiling (Alternative
lengths available. Example: SCF6 =
6' Cable)
150=150W
250=250W
BDF=Black Door Frame
G2=Double Gasketing Doors (Door to
Lens, Lens to Door)
2
MH available in non-U.S. markets only.
3
Not available with GMXR door frame.
4
All lamps are mogul-base except 150W Metal Halide and below are medium-base. Lamp not included.
5
Products also available in non-US voltages and 50HZ for international markets.
6
120/277V MH only.
7
Q and EM - 150W max.
8
Not available with HC or HL.
9
Lamp is shipped separate from luminaire. Lamp is Cooper designated product based on luminaire requirements. Specified
lamps must be ordered as a separate line item.
10
Adds 3-1/4" to overall fixture height.
11
Requires vertical lamp option (VL).
12
Not available with EM or EM/SC.
13
Order separately.
14
Not available with FTA, FTB or FTW.
Frame Kit, Natural
Anodized Aluminum
FTB=Flush Drywall Frame
Kit, Black
FTW=Flush Drywall
Frame Kit, White
EM/SC=Emergency Separate Circuit
LL=Lamp Included9
CEC=California Title 20 Compliant Ballast
(Applies to 250-320W and
400-450W only)
MP or MH lamps MUST have glass overlay (GL, H8246, or C73).
Accessories 13
WGQF=Wire Guard14
FTA=Flush Drywall
Q=Quartz Restrike (Hot Strike Only)7
EM=Quartz Restrike with ''Delay 7, 8
Relay'' (Quartz lamp strikes at
both hot and cold starts)
70=70W
100=100W
400=400W
Notes: 1
Options
OR=Open Rated Socket For Metal Halide
Lamps
VL=Vertical Lamp10
11, 12
HC=LumaWatt Fixture Control
Module (Low voltage leads
pulled out of top connection box
for areas requiring all wiring to
be installed in conduit)
11, 12
HL=LumaWatt Fixture Control
Module (Allows low voltage
control wire to be daisy-chained
between fixtures outside AC
conduit run similar to low voltage
intercom's, fire alarms and
phone systems)
DL=UL Labeled for Damp Locations
NOTE: Specifications and dimensions subject to change without notice.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
ADH081457 pc
2010-11-09 12:24:27
2010-11-09 12:11:32
Download