COOPER LIGHTING - LUMARK ® DESCRIPTION The Lumark Quadra-Lume is perfect for applications which call for reliable, affordable illumination with minimal maintenance. Quadra-Lume is designed for easy installation on main T-bars or can be hung by wires in lay-in ceilings with 2' x 2' tiles. U.L. listed and CSA certified. The Quadra-Lume provides minimum surface brightness, excellent uniformity and gentle diffusion. It is ideal for use in department stores, banks, auto showrooms, schools, libraries, office buildings and auditoriums. Type Catalog # Project Date Comments Prepared by S P E C I F I C AT I O N F E AT U R E S Construction Optics HOUSING: Die-formed, heavy-duty housing is made of cold-rolled steel and finished in highly reflective white polyester powder coat. Stamped steel ballast mounting bracket is integral part of housing. DOOR FRAME: Dieformed, heavy-gauge steel frame can be hinged and latched from either side. Stamped steel retaining clips assure flush fit of lens with frame. REFLECTOR: Die-formed steel reflector has removable panels for easy ballast access from below. LENS: Gasketed flat prismatic acrylic or C73 glass lens. QF QUADRA-LUME High Pressure Sodium Pulse Start Metal Halide Metal Halide RECESSED COMMERCIAL E N E R G Y D ATA High Reactance Ballast Input Watts 150W HPS HPF (190 Watts) DIMENSIONS CWI Ballast Input Watts 175W MH HPF (223 Watts) 250W HPS HPF (300 Watts) 250W MH HPF (300 Watts) 400W HPS HPF (465 Watts) 400W MH HPF (475 Watts) S H I P P I N G D ATA Approximate Net Weight: 39 lbs. (18 kgs.) C ER TEM S YS D 23-7/8" [606mm] CWA Ballast Input Watts 175W MP HPF (198 Watts) G 200W MP HPF (227 Watts) G 250W MP HPF (283 Watts) G 320W MP HPF (365 Watts) G 350W MP HPF (400 Watts) G 400W MP HPF (452 Watts) G 400W HPS HPF (465 Watts) S 11" [280mm] TIFIE ADH081457 pc 2010-11-09 12:24:27 QF - QUADRA-LUME P H OTO M E T R I C S 90 30 60 90 60 30 120 150 CP/100 MHQF-GL-C73-400 400-Watt Metal Halide 40,000-Lumen Coated Lamp Coefficients Of Utilization Candlepower Effective floor cavity reflectance 20% rc 80% rw 70 50 30 RCR 0 89 89 89 70 70% 50 30 50% 50 30 30% 50 30 87 87 87 83 83 79 79 1 82 79 76 80 77 75 74 72 71 70 2 76 70 66 74 69 65 66 63 64 61 3 70 63 57 68 62 56 59 55 57 54 4 64 56 50 63 55 50 54 49 52 48 5 60 51 45 58 50 44 49 43 47 43 6 55 46 40 54 46 40 44 39 43 38 7 52 42 36 50 42 36 40 35 39 35 8 48 39 33 47 38 33 37 32 36 32 9 45 36 30 44 35 30 34 29 34 29 10 42 33 27 41 33 27 32 27 31 27 Degree 0 5 15 25 35 45 55 65 75 85 CP 12888 12878 12798 12165 10322 7253 3975 2097 1121 437 F L U S H M O U N T I N G T R I M ( F T B, F TW, F TA ) Heavy-gauge extruded aluminum combination fixture trim and plaster frame. Neatly finishes out any 2’ x 2’ recessed installation. Aluminum fixture trim secured to ceiling support system with screws. 24” [610mm] sq. 25 1/8’ [638mm] sq. min. opening required 26” [660mm] sq. ORDERING INFORMATION Sample Number: MHQF-GS-C73-400-120V-Q Lamp Type MP=Pulse Start Metal Halide1 Door Frame GS=Flat Steel Lamp Wattage MP 120V MH=Metal Halide1, 2 HP=High Pressure Sodium GO/GAS=Flat Aluminum GMXF=Flat, Non-Floating Aluminum Door Frame 70=70W 100=100W 208V Series QF=Quadra-Lume w/ Flat Lens 175=175W 200=200W GMXR=3/8'' Regressed Non-Floating Aluminum Door Frame 350=350W 400=400W A/GL=Acrylic Lens w/ Glass Overlay ACTF.140=Acrituf, 0.140'' Thick MH C73=Prismatic Tempered Glass Lens PL=Polycarbonate Refractor Voltage 5 240V 277V 347V 250=250W 320=320W Lens Type 1 A=Acrylic Lens ACTF.187=Acrituf, 0.187'' Thick H8246=Halophone 82463 4 2 175=175W 250=250W 400=400W HP QB=Quiet Ballast6 F1=Single Fuse (120, 277 or 347V only) F2=Double Fuse (208, 240 or 480V only) SCF=3' Aircraft Safety Cable secures Housing to Ceiling (Alternative lengths available. Example: SCF6 = 6' Cable) 150=150W 250=250W BDF=Black Door Frame G2=Double Gasketing Doors (Door to Lens, Lens to Door) 2 MH available in non-U.S. markets only. 3 Not available with GMXR door frame. 4 All lamps are mogul-base except 150W Metal Halide and below are medium-base. Lamp not included. 5 Products also available in non-US voltages and 50HZ for international markets. 6 120/277V MH only. 7 Q and EM - 150W max. 8 Not available with HC or HL. 9 Lamp is shipped separate from luminaire. Lamp is Cooper designated product based on luminaire requirements. Specified lamps must be ordered as a separate line item. 10 Adds 3-1/4" to overall fixture height. 11 Requires vertical lamp option (VL). 12 Not available with EM or EM/SC. 13 Order separately. 14 Not available with FTA, FTB or FTW. Frame Kit, Natural Anodized Aluminum FTB=Flush Drywall Frame Kit, Black FTW=Flush Drywall Frame Kit, White EM/SC=Emergency Separate Circuit LL=Lamp Included9 CEC=California Title 20 Compliant Ballast (Applies to 250-320W and 400-450W only) MP or MH lamps MUST have glass overlay (GL, H8246, or C73). Accessories 13 WGQF=Wire Guard14 FTA=Flush Drywall Q=Quartz Restrike (Hot Strike Only)7 EM=Quartz Restrike with ''Delay 7, 8 Relay'' (Quartz lamp strikes at both hot and cold starts) 70=70W 100=100W 400=400W Notes: 1 Options OR=Open Rated Socket For Metal Halide Lamps VL=Vertical Lamp10 11, 12 HC=LumaWatt Fixture Control Module (Low voltage leads pulled out of top connection box for areas requiring all wiring to be installed in conduit) 11, 12 HL=LumaWatt Fixture Control Module (Allows low voltage control wire to be daisy-chained between fixtures outside AC conduit run similar to low voltage intercom's, fire alarms and phone systems) DL=UL Labeled for Damp Locations NOTE: Specifications and dimensions subject to change without notice. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH081457 pc 2010-11-09 12:24:27 2010-11-09 12:11:32