FAIL-SAFE

advertisement
FAIL-SAFE
D ES C R IPTION
The Prolume Prismatic Luminaire has been designed and constructed
specifically for food processing industry environments. UL/cUL listed.
NEMA 4 watertight. Accepts up to 1300 PSI water spray cleaning. NSF
and FDA compliant. Ideal for mounting heights between 12-25', utilize the
Prolume for food processing facilities where ease of cleaning is required.
Luminaire housing and optical components may be quickly disassembled
for easy maintenance.
®
Type
Catalog #
Project
Date
Comments
Prepared by
S PEC IFIC A TION FEA T U R E S
Mounting
Re fra c tor
Do o r R efractor
Die-cast mounting box is tapped
with an opening for 3/4” conduit.
Side access plate allows for quick
connections and easy installation.
The high-efficiency prismatic
acrylic refractor is sealed to the
ballast housing to prevent ingress
of water and dirt. Mounted to
the ballast housing with toolless
fasteners, the vertical prisms
provide a natural run-off under
high-pressure hosedown cleaning.
Twist and lock refractor door
allows for toolless removal. Sealed
and gasketed to exclude dirt and
moisture. Conical prism design
minimizes direct glare.
Housing
The heavy-duty, spun aluminum
housing is finished in a standard
white polyester powder coat. Other
finish colors available including an
anodized aluminum.
Soc ke t
Mogul-base porcelain socket. For
Metal Halide, protected socket is
standard, for use with “O” openrated, protected Metal Halide
lamps only.
B allast
High power factor ballast with
class H insulation. UL/cUL listed for
40°C (105°F) ambient temperature
operation. Minimum starting
temperature is -40°C (-40° F) for
High Pressure Sodium and -30°C
(-20° F) for Metal Halide. Pulse
Start Metal Halide systems are
also available in CWA and Linear
Reactor (277V only) configurations
for greater operating efficiencies.
FP
22” PROLUME
High Pressure Sodium
Pulse Start Metal Halide
Clean Room / Food Processing
Prismatic Acrylic
1300 PSI Hosedown
D IMENS IONS
5"
[127mm]
ENERGY DATA
27"
[686mm]
23 1/4" [591mm]
CWA Ballast Input Watts
175W MP HPF (198 Watts) E
200W MP HPF (227 Watts) E
250W MP HPF (283 Watts) E
320W MP (365 Watts) E
350W MP (400 Watts) E
400W MP HPF (452 Watts) E
400W HPS HPF (465 Watts)
450W MP HPF (508 Watts) E
CWI Ballast Input Watts
200W HPS HPF (250 Watts)
250W HPS HPF (300 Watts)
400W HPS HPF (465 Watts)
ADC040987
2014-09-02 10:27:08
FP 2 2 ” PR O L U M E
ORDER ING INFOR M A TION
SAMPLE NUMBER: MPFP-TL22-400-MT-OR
Lamp
Type
Reflector
Type
Series
Reflector
Diameter
TL
FP
HP= High Pressure
MP= Pulse Start
MH (CWA)
Socket
120= 120V
208= 208V
240= 240V
277= 277V
347= 347V
480= 480V
MT= Multi-Tap 1
TT= Triple-Tap 1
MP
175=175W
200=200W
250=250W
320=320W
350=350W
400=400W
_____ = Not applicable
(HPS or not
compatible
with OR
Socket)
F1= Single Fuse - 120, 277 or
347V (Specify single
voltage only.)
F2= Double Fused - 208, 240 or
408V (Specify single
voltage only)
AZ= Anodized Ballast Housing
Q= Quartz Restrike DC Bayonet
Base (Hot strike only)
EM= Quartz Restrike with
“Delay Relay” (Strikes at
(Cold Start)
CWI=Isolated Secondary Ballast
HC=LumaWatt Fixture Control
Module (Low voltage leads
pulled out of top connection
box for areas requiring all
wiring to be installed in conduit)
OR = Open-rated socket
for pulse start
metal halide
lamps 4
TL=Twist & Lock
Prismatic C/W
Conical Prismatic
Door
Catalog
Number 1
HPFP-TL22-200
HPFP-TL22-250
HPFP-TL22-400
MPFP-TL22-320
MPFP-TL22-350
Accessories
(Order separately)
Options
22
22=22"
FP=Prolume
Voltage 2
Lamp
Lamp
Type/Base
HPS/Mogul
HPS/Mogul
HPS/Mogul
Pulse Start MH/Mogul
Pulse Start MH/Mogul
Lamp
Wattage
200
250
400
320
350
S/MH
1.8
1.8
1.8
1.8
1.8
Net Wt.
(lbs.)
34
34
37
35
35
Distribution
Wide
Wide
Wide
Wide
Wide
FH-1=Fixture Hook (Not for NEMA
4 application)
FL-1=Fixture Loop (Not for NEMA
4 application)
FLN-5=Fixture Loop Approved
for NEMA 4 application)
C3=Cord-NoPlug-Requires FH-1,
FL-1 or FLN-5
LL=Lamp Included (Metal halide
lamp is coated.)
Fixture
Height
32" (784mm)
32" (784mm)
32" (784mm)
32" (784mm)
32" (784mm)
Shipping
Volume (cu. ft.)
Ballast
1/ctn.
0.80
5/ctn.
3.66
NOTES: 1 Multi-Tap ballast is 120/208/240/277V wired 277V. Triple-Tap ballast is 120/277/347V wired 347V. Add desired voltge before “MT” OR “TT”
2 Products also available in non-US voltages and 50 Hz for international markets. Various ballast configurations available.
3 277V only; not available in quartz restrike.
4 Not applicable for HPS lamps.
PH OTOM ETR IC S
90˚
2.0
###
4.9
6.1
8.1
M H F P- T L 2 2 - 4 0 0 - M T
400-Watt Metal Halide
36,000-Lumen Clear Lamp
60˚
30˚
Coefficients Of Utilization
Effective floor cavity reflectance
rc
80%
70%
rw 70 50 30 10
70 50 30
RCR
1 97 92 87 84
92 87 83
2 88 80 73 68
83 76 70
3 80 70 62 56
76 67 60
4 73 62 54 48
69 59 52
5 67 55 47 41
63 53 45
6 62 50 41 35
58 47 40
7 57 45 37 31
54 43 35
8 53 41 33 27
50 39 32
9 49 37 29 24
47 35 28
10 46 34 27 22
44 33 26
Spacing Criterion
1.8
Zone
%Lamp
Zone
0-30
16.7
0-90
0-40
30.6
90-180
0-60
54.9
Total
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
10
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
80
65
54
46
39
34
30
26
24
21
79
69
61
54
48
43
39
36
33
30
71
62
55
49
44
39
36
33
30
28
64
56
50
44
40
36
33
30
27
25
57
47
40
34
29
25
22
20
18
16
76
64
55
48
42
37
33
29
26
24
73
60
50
43
37
32
28
25
22
20
%Lamp
70.8
24.0
94.8
Eaton’s Cooper Lighting Business
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
Specifications and
dimensions subject to
change without notice.
69
58
50
44
38
34
30
27
25
22
67
55
47
40
34
30
26
23
21
19
62
53
46
40
35
31
28
25
23
21
61
51
43
37
32
28
25
22
20
18
Candlepower
Degree CP
0
5979
5
6180
15
6819
25
7435
35
8177
45
6686
55
3964
65
2269
75
1616
85
1525
90
1540
95
1643
105
1798
115
1765
125
1342
135
991
145
846
155
843
165
850
175
568
180
441
ADC040987
2014-09-02 10:27:08
Download