FAIL-SAFE D ES C R IPTION The Prolume Prismatic Luminaire has been designed and constructed specifically for food processing industry environments. UL/cUL listed. NEMA 4 watertight. Accepts up to 1300 PSI water spray cleaning. NSF and FDA compliant. Ideal for mounting heights between 12-25', utilize the Prolume for food processing facilities where ease of cleaning is required. Luminaire housing and optical components may be quickly disassembled for easy maintenance. ® Type Catalog # Project Date Comments Prepared by S PEC IFIC A TION FEA T U R E S Mounting Re fra c tor Do o r R efractor Die-cast mounting box is tapped with an opening for 3/4” conduit. Side access plate allows for quick connections and easy installation. The high-efficiency prismatic acrylic refractor is sealed to the ballast housing to prevent ingress of water and dirt. Mounted to the ballast housing with toolless fasteners, the vertical prisms provide a natural run-off under high-pressure hosedown cleaning. Twist and lock refractor door allows for toolless removal. Sealed and gasketed to exclude dirt and moisture. Conical prism design minimizes direct glare. Housing The heavy-duty, spun aluminum housing is finished in a standard white polyester powder coat. Other finish colors available including an anodized aluminum. Soc ke t Mogul-base porcelain socket. For Metal Halide, protected socket is standard, for use with “O” openrated, protected Metal Halide lamps only. B allast High power factor ballast with class H insulation. UL/cUL listed for 40°C (105°F) ambient temperature operation. Minimum starting temperature is -40°C (-40° F) for High Pressure Sodium and -30°C (-20° F) for Metal Halide. Pulse Start Metal Halide systems are also available in CWA and Linear Reactor (277V only) configurations for greater operating efficiencies. FP 22” PROLUME High Pressure Sodium Pulse Start Metal Halide Clean Room / Food Processing Prismatic Acrylic 1300 PSI Hosedown D IMENS IONS 5" [127mm] ENERGY DATA 27" [686mm] 23 1/4" [591mm] CWA Ballast Input Watts 175W MP HPF (198 Watts) E 200W MP HPF (227 Watts) E 250W MP HPF (283 Watts) E 320W MP (365 Watts) E 350W MP (400 Watts) E 400W MP HPF (452 Watts) E 400W HPS HPF (465 Watts) 450W MP HPF (508 Watts) E CWI Ballast Input Watts 200W HPS HPF (250 Watts) 250W HPS HPF (300 Watts) 400W HPS HPF (465 Watts) ADC040987 2014-09-02 10:27:08 FP 2 2 ” PR O L U M E ORDER ING INFOR M A TION SAMPLE NUMBER: MPFP-TL22-400-MT-OR Lamp Type Reflector Type Series Reflector Diameter TL FP HP= High Pressure MP= Pulse Start MH (CWA) Socket 120= 120V 208= 208V 240= 240V 277= 277V 347= 347V 480= 480V MT= Multi-Tap 1 TT= Triple-Tap 1 MP 175=175W 200=200W 250=250W 320=320W 350=350W 400=400W _____ = Not applicable (HPS or not compatible with OR Socket) F1= Single Fuse - 120, 277 or 347V (Specify single voltage only.) F2= Double Fused - 208, 240 or 408V (Specify single voltage only) AZ= Anodized Ballast Housing Q= Quartz Restrike DC Bayonet Base (Hot strike only) EM= Quartz Restrike with “Delay Relay” (Strikes at (Cold Start) CWI=Isolated Secondary Ballast HC=LumaWatt Fixture Control Module (Low voltage leads pulled out of top connection box for areas requiring all wiring to be installed in conduit) OR = Open-rated socket for pulse start metal halide lamps 4 TL=Twist & Lock Prismatic C/W Conical Prismatic Door Catalog Number 1 HPFP-TL22-200 HPFP-TL22-250 HPFP-TL22-400 MPFP-TL22-320 MPFP-TL22-350 Accessories (Order separately) Options 22 22=22" FP=Prolume Voltage 2 Lamp Lamp Type/Base HPS/Mogul HPS/Mogul HPS/Mogul Pulse Start MH/Mogul Pulse Start MH/Mogul Lamp Wattage 200 250 400 320 350 S/MH 1.8 1.8 1.8 1.8 1.8 Net Wt. (lbs.) 34 34 37 35 35 Distribution Wide Wide Wide Wide Wide FH-1=Fixture Hook (Not for NEMA 4 application) FL-1=Fixture Loop (Not for NEMA 4 application) FLN-5=Fixture Loop Approved for NEMA 4 application) C3=Cord-NoPlug-Requires FH-1, FL-1 or FLN-5 LL=Lamp Included (Metal halide lamp is coated.) Fixture Height 32" (784mm) 32" (784mm) 32" (784mm) 32" (784mm) 32" (784mm) Shipping Volume (cu. ft.) Ballast 1/ctn. 0.80 5/ctn. 3.66 NOTES: 1 Multi-Tap ballast is 120/208/240/277V wired 277V. Triple-Tap ballast is 120/277/347V wired 347V. Add desired voltge before “MT” OR “TT” 2 Products also available in non-US voltages and 50 Hz for international markets. Various ballast configurations available. 3 277V only; not available in quartz restrike. 4 Not applicable for HPS lamps. PH OTOM ETR IC S 90˚ 2.0 ### 4.9 6.1 8.1 M H F P- T L 2 2 - 4 0 0 - M T 400-Watt Metal Halide 36,000-Lumen Clear Lamp 60˚ 30˚ Coefficients Of Utilization Effective floor cavity reflectance rc 80% 70% rw 70 50 30 10 70 50 30 RCR 1 97 92 87 84 92 87 83 2 88 80 73 68 83 76 70 3 80 70 62 56 76 67 60 4 73 62 54 48 69 59 52 5 67 55 47 41 63 53 45 6 62 50 41 35 58 47 40 7 57 45 37 31 54 43 35 8 53 41 33 27 50 39 32 9 49 37 29 24 47 35 28 10 46 34 27 22 44 33 26 Spacing Criterion 1.8 Zone %Lamp Zone 0-30 16.7 0-90 0-40 30.6 90-180 0-60 54.9 Total Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com 10 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 80 65 54 46 39 34 30 26 24 21 79 69 61 54 48 43 39 36 33 30 71 62 55 49 44 39 36 33 30 28 64 56 50 44 40 36 33 30 27 25 57 47 40 34 29 25 22 20 18 16 76 64 55 48 42 37 33 29 26 24 73 60 50 43 37 32 28 25 22 20 %Lamp 70.8 24.0 94.8 Eaton’s Cooper Lighting Business 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com Specifications and dimensions subject to change without notice. 69 58 50 44 38 34 30 27 25 22 67 55 47 40 34 30 26 23 21 19 62 53 46 40 35 31 28 25 23 21 61 51 43 37 32 28 25 22 20 18 Candlepower Degree CP 0 5979 5 6180 15 6819 25 7435 35 8177 45 6686 55 3964 65 2269 75 1616 85 1525 90 1540 95 1643 105 1798 115 1765 125 1342 135 991 145 846 155 843 165 850 175 568 180 441 ADC040987 2014-09-02 10:27:08