Catalog # Type

advertisement
COOPER LIGHTING - LUMARK
®
DESCRIPTION
The LumaWatt controller accepts inputs from up to four remote-mounted
motion detectors and provides a 24 volt DC low-voltage output capable of
controlling up to 25 fixtures. It switches connected fixtures from low
intensity to high, providing maximum light when an area is occupied and
lowered energy usage when the area is empty. U.L. listed and CSA certified.
Use in conjunction with LumaWatt-equipped Lumark indoor industrial
fixtures.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
A ... 24 Volt DC Output
Low voltage output controls up to
25 LumaWatt-equipped fixtures.
D ... Remote Switch Input
Input terminal allows use of
user-supplied dry-contact switch.
Switch overrides motion sensors,
putting system into high
brightness mode. In absence of
motion detectors, switch provides
manual high-low control. Consult
Technical Services for 1000W
applications.
B ... Control #2 Output
Allow daisy-chaining of multiple
controllers.
C ... Motion Detector Inputs
Terminal block provides input
connections for one to six passive
infrared motion sensors.
A
B
E ... Transformer
Standard transformer accepts 120V
or 277V user-configurable input.
208V, 240V, 347V and 480V are
also available.
F ... LED Indicator Lights
Three front panel lights show
system status: amber indicates that
the controller is receiving power,
red indicates that output from the
controller is at full brightness and
green indicates that output is at
low brightness.
G ... Bi-Level Function Switch
Front panel switch provides same
function as remote dry-contact
switch.
H ... Initializing Timer
CMOS timer maintains system in
full brightness mode for a 15
minute warm-up period when
power is applied.
D
C
CML
INDUSTRIAL HID
DIMMING SYSTEM
Controls all LumaWatt Equipped Lumark HID
Industrial Luminaires
E
CONTROL MODULE
Output
– 2 +
Control
#2
– 2 +
Aux.
Controller
+
+
Aux.
Controller
+
+
Dry
Contact
– 2 +
T E C H N I C A L D AT A
55 Degree C Maximum Ambient
E N E R G Y D AT A
G
CWA Ballast High/Low Input Watts
150W HPS HPF (196/118 Watts)
250W HPS HPF (300/151 Watts)
2 13/32"
[61mm]
4 5/8"
[117mm]
3 3/4"
[95mm]
8 23/32" [221mm]
400W HPS HPF (465/215 Watts)
1000W HPS HPF (1100/616 Watts)
175W MH HPF (210/101 Watts)
250W MH HPF (295/162 Watts)
400W MH HPF (455/238 Watts)
1000W MH HPF (1080/666 Watts)
Consult your representative for additional options and finishes.
T EM
S
Specifications and Dimensions subject to change without notice.
YS
ER
C
7 15/16" [202mm]
8 7/8" [225mm]
D
F
S
DIMENSIONS
TIFIE
ADH041467
06/25/2007 2:59:57 PM
SYSTEM CONFIGURATION
CML LUMAWATT CONTROLLER
Output
#2
#1
# 25
Maximum
Control #2
RED
Detector
Input
BLACK
BLUE
RED
Detector
Input
BLACK
BLUE
Dry Contact
Wiring Chart
Maximum distance between LumaWatt
Control Module and the first luminaire,
based upon total number of fixtures
controlled.
Number
of Fixtures
#16 AWG
#18AWG
1
7500
4700
2
3700
2300
3
2500
1600
4
1900
1200
5
1500
900
6
1200
800
7
1100
700
8
900
600
9
800
500
10
700
500
11
700
400
12-13
600
400
14-16
500
300
17-18
400
300
19-21
400
200
22-25
300
200
Master Controller
Optional Motion Detector Modules
(Maximum 6 )
LumaWatt Lamp Input Watts
Wattage
High (HW)
Low
Change (PC)
Metal Halide
Output
Control #2
1000W
1080
666
38%
400W
455
238
48%
250W
295
162
45%
175W
209
101
52%
44%
High Pr essure Sodium
Detector
Input
Detector
Input
#2
#1
1000W
1100
616
400W
465
215
54%
250W
300
151
50%
150W
196
118
40%
# 25
Maximum
Dry Contact
Additional Control Module(s) (required to control subsequent groups of fixtures up to 25 each)
Auxiliary Controller
HL FIXTURE MODULE
ORDERING INFORMATION
Sample Number: CML-120/277
Product Family 1, 2
CML=LumaWatt Control Module
Input Voltage 3
120/277=User selectable 120V or 277V input voltage
208V=208V
240V=240V
347V=347V
480V=480V
Notes:
1 System utilizes a 30 second time delay in
switching between power levels. 2 See separate
cutsheet for full details on control module. 3
Products also available in non-US voltages and
50HZ for international markets. Consult factory for
availabiltiy and ordering information.
OTHER LUMAWATT COMPONENTS
Fixture Module
(add as suffix to any Lumark indoor
industrial fixtures)
HL=Allows low voltage control wire to be
daisey-chained between
fixtures outside AC conduit run similar
to low voltage intercoms, fire alarms
and phone systems.
HC=Low voltage leads pulled out of top
connection box for areas requiring all
wiring to be installed in conduit.
Motion Detectors (order separately)
IRMD-N-24V=Passive infrared motion
detector with narrow
coverage pattern 3
IRMD-W-24V=Passive infrared motion
detector with wide
coverage pattern 3
IRMD-A-24V=Passive infrared motion
detector for aisleway
coverage 3
Specifications and Dimensions subject to change without notice.
Lumark • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADH041467
06/25/2007 2:59:57 PM
Download