COOPER LIGHTING - LUMARK ® DESCRIPTION The Lumark Quadra-Mark is designed for easy installation on main T-bars or can be hung by wires in lay-in ceilings with 2' x 2' tiles. U.L. listed and CSA certified. The Quadra-Mark provides excellent distribution with minimal glare for use in supermarkets, hardware stores, auto showrooms, airport terminals, shopping malls and other areas with high ceilings requiring perfomance and aesthetics. Catalog # Type Project Comments Date Prepared by S P E C I F I C AT I O N F E AT U R E S Construction SOCKET HOUSING: Heavy-duty die-cast aluminum socket housing, finished with white polyester powder coat, allows full adjustment of socket assembly for a variety of distributions from concentrated to wide. FRAME: Prime, cold-rolled steel pan is dieformed for maximum rigidity and has a 45° angled lip around the reflector opening to help reduce glare. It is finished with a white polyester powder coat and mounts easily into inverted T-bar ceilings. Optics REFLECTOR: Computer-designed spun aluminum faceted reflector offers maximum light output with minimum voltage rise. Electrical BALLAST: The thermally protected, high power factor 60Hz Metal Halide ballast is UL listed. QC QUADRA-MARK Pulse Start Metal Halide Metal Halide RECESSED COMMERCIAL DIMENSIONS S H I P P I N G D ATA Approximate Net Weight: 42 lbs. (19 kgs.) C ER TEM S YS D 24" [610mm] square E N E R G Y D ATA CWA Ballast Input Watts 175W MP HPF (198 Watts) G 200W MP HPF (227 Watts) G 250W MP HPF (283 Watts) G 320W MP HPF (365 Watts) G 350W MP HPF (400 Watts) G 400W MP HPF (452 Watts) G 400W HPS HPF (465 Watts) S 19-3/32" [485mm] TIFIE ADH082460 pc 2010-11-09 12:23:43 QC - QUADRA-MARK P H OTO M E T R I C S 90 5 9 60 13 30 17 CP/1000 M H Q C - Q C S A1 8 - W - 4 0 0 - T 400-Watt Metal Halide 36,000-Lumen Clear Lamp Wide Distribution Coefficients Of Utilization Effective floor cavity reflectance 20% rc 80% 70% rw 70 50 30 10 70 50 30 10 RCR 1 93 90 88 85 91 88 86 84 50% 50 30 10 30% 50 30 10 10% 50 30 10 0 0 84 82 80 80 78 77 76 75 74 72 2 87 82 78 74 85 80 76 73 77 73 71 73 71 68 70 68 66 65 3 81 74 69 64 79 72 67 63 69 65 62 67 63 60 64 61 59 57 4 75 67 61 56 73 66 60 56 63 58 54 61 57 53 58 55 52 51 5 69 60 54 49 67 59 53 49 57 52 48 55 50 47 53 49 46 44 6 65 54 47 43 62 53 47 42 51 46 42 49 44 41 48 43 40 39 7 58 48 41 36 57 47 41 36 45 40 36 44 39 35 42 38 35 33 8 54 43 36 32 52 42 36 31 41 35 31 39 34 30 38 33 30 28 9 49 38 32 27 48 38 31 27 36 31 27 35 30 26 34 29 26 24 10 45 34 28 23 44 34 27 23 32 27 23 31 26 22 30 26 22 21 Candlepower Degree CP 0 9725 5 8934 15 8131 25 10678 35 12926 45 9338 55 5204 65 844 75 109 85 10 90 1 Spacing Criterion 1.6 Zone %Lamp 0-30 22.60 0-40 44.70 0-60 77.10 0-90 80.10 90-180 .00 Total 80.10 ORDERING INFORMATION Sample Number: MHQC-QCSA18-C-175-T-120V-QMGL Lamp Type 1 MP=Pulse Start Metal1 Halide Reflector Type QCSA18=18'' MH=Metal Halide1, 2 Distribution C=Concentrated Series QC=Quadra-Mark M=Medium W=Wide Lamp Wattage MP Mounting T=T Bar Voltage 175=175W 200=200W 208V 4 240V 4 250=250W 320=320W 277V 350=350W 400=400W 480V MH 3 120V 347V 4 2 175=175W 250=250W 400=400W Notes: 1 MH and MP require OMGL. 2 MH available in non-U.S. markets only. 3 Products also available in non-US voltages and 50HZ for international markets. 4 Not available in Canada. 5 Quartz lamp wattage is 150W max. 6 Not available with HC or HL. 7 Lamp is shipped separate from luminaire. Lamp is Cooper designated product based on luminaire requirements. Specified lamps must be ordered as a separate line item. 8 Not available with EM or EM/SC. Options OR=Open Rated Socket For Metal Halide Lamps F1=Single Fuse (120, 277 or 347V only) F2=Double Fuse (208, 240 or 480V only) Q=Quartz Restrike (Hot Strike Only)5 EM=Quartz Restrike with ''Delay Relay'' (Quartz lamp strikes 6 at both hot and cold starts) EM/SC=Emergency Separate Circuit LL=Lamp Included7 CEC=California Title 20 Compliant Ballast (Applies to 250-320W and 400-450W MP only) HC=LumaWatt Fixture Control Module (Low voltage leads 8 pulled out of top connection box for areas requiring all wiring to be installed in conduit) HL=LumaWatt Fixture Control Module (Allows low voltage 8 control wire to be daisy-chained between fixtures outside AC conduit run similar to low voltage intercom's, fire alarms and phone systems) DL=UL Labeled for Damp Locations NOTE: Specifications and dimensions subject to change without notice. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH082460 pc 2010-11-09 12:23:43 2010-11-09 13:11:35