COOPER LIGHTING - LUMARK Catalog # Type

advertisement
COOPER LIGHTING - LUMARK ®
DESCRIPTION
The Lumark Quadra-Mark is designed for easy installation on main T-bars
or can be hung by wires in lay-in ceilings with 2' x 2' tiles. U.L. listed and
CSA certified.
The Quadra-Mark provides excellent distribution with minimal glare for
use in supermarkets, hardware stores, auto showrooms, airport
terminals, shopping malls and other areas with high ceilings requiring
perfomance and aesthetics.
Catalog #
Type
Project
Comments
Date
Prepared by
S P E C I F I C AT I O N F E AT U R E S
Construction
SOCKET HOUSING: Heavy-duty
die-cast aluminum socket housing,
finished with white polyester
powder coat, allows full
adjustment of socket assembly for
a variety of distributions from
concentrated to wide. FRAME:
Prime, cold-rolled steel pan is dieformed for maximum rigidity and
has a 45° angled lip around the
reflector opening to help reduce
glare. It is finished with a white
polyester powder coat and mounts
easily into inverted T-bar ceilings.
Optics
REFLECTOR: Computer-designed
spun aluminum faceted reflector
offers maximum light output with
minimum voltage rise.
Electrical
BALLAST: The thermally protected,
high power factor 60Hz Metal
Halide ballast is UL listed.
QC
QUADRA-MARK
Pulse Start Metal Halide
Metal Halide
RECESSED COMMERCIAL
DIMENSIONS
S H I P P I N G D ATA
Approximate Net Weight:
42 lbs. (19 kgs.)
C
ER
TEM
S
YS
D
24"
[610mm]
square
E N E R G Y D ATA
CWA Ballast Input Watts
175W MP HPF (198 Watts) G
200W MP HPF (227 Watts) G
250W MP HPF (283 Watts) G
320W MP HPF (365 Watts) G
350W MP HPF (400 Watts) G
400W MP HPF (452 Watts) G
400W HPS HPF (465 Watts)
S
19-3/32"
[485mm]
TIFIE
ADH082460 pc
2010-11-09 12:23:43
QC - QUADRA-MARK
P H OTO M E T R I C S
90
5
9
60
13
30
17
CP/1000
M H Q C - Q C S A1 8 - W - 4 0 0 - T
400-Watt Metal Halide
36,000-Lumen Clear Lamp
Wide Distribution
Coefficients Of Utilization
Effective floor cavity reflectance
20%
rc
80%
70%
rw
70 50 30 10
70 50 30 10
RCR
1
93 90 88 85
91 88 86 84
50%
50 30 10
30%
50 30 10
10%
50 30 10
0
0
84 82 80
80 78 77
76 75 74
72
2
87 82 78 74
85 80 76 73
77 73 71
73 71 68
70 68 66
65
3
81 74 69 64
79 72 67 63
69 65 62
67 63 60
64 61 59
57
4
75 67 61 56
73 66 60 56
63 58 54
61 57 53
58 55 52
51
5
69 60 54 49
67 59 53 49
57 52 48
55 50 47
53 49 46
44
6
65 54 47 43
62 53 47 42
51 46 42
49 44 41
48 43 40
39
7
58 48 41 36
57 47 41 36
45 40 36
44 39 35
42 38 35
33
8
54 43 36 32
52 42 36 31
41 35 31
39 34 30
38 33 30
28
9
49 38 32 27
48 38 31 27
36 31 27
35 30 26
34 29 26
24
10
45 34 28 23
44 34 27 23
32 27 23
31 26 22
30 26 22
21
Candlepower
Degree CP
0
9725
5
8934
15
8131
25
10678
35
12926
45
9338
55
5204
65
844
75
109
85
10
90
1
Spacing Criterion 1.6
Zone
%Lamp
0-30
22.60
0-40
44.70
0-60
77.10
0-90
80.10
90-180
.00
Total
80.10
ORDERING INFORMATION
Sample Number: MHQC-QCSA18-C-175-T-120V-QMGL
Lamp Type 1
MP=Pulse Start Metal1
Halide
Reflector Type
QCSA18=18''
MH=Metal Halide1, 2
Distribution
C=Concentrated
Series
QC=Quadra-Mark
M=Medium
W=Wide
Lamp Wattage
MP
Mounting
T=T Bar
Voltage
175=175W
200=200W
208V
4
240V
4
250=250W
320=320W
277V
350=350W
400=400W
480V
MH
3
120V
347V
4
2
175=175W
250=250W
400=400W
Notes: 1
MH and MP require OMGL.
2
MH available in non-U.S. markets only.
3
Products also available in non-US voltages and 50HZ for international markets.
4
Not available in Canada.
5
Quartz lamp wattage is 150W max.
6
Not available with HC or HL.
7
Lamp is shipped separate from luminaire. Lamp is Cooper designated product based on luminaire requirements. Specified lamps
must be ordered as a separate line item.
8
Not available with EM or EM/SC.
Options
OR=Open Rated Socket For Metal Halide Lamps
F1=Single Fuse (120, 277 or 347V only)
F2=Double Fuse (208, 240 or 480V only)
Q=Quartz Restrike (Hot Strike Only)5
EM=Quartz Restrike with ''Delay Relay'' (Quartz lamp strikes 6
at both hot and cold starts)
EM/SC=Emergency Separate Circuit
LL=Lamp Included7
CEC=California Title 20 Compliant Ballast (Applies to
250-320W and 400-450W MP only)
HC=LumaWatt Fixture Control Module (Low voltage leads 8
pulled out of top connection box for areas requiring all
wiring to be installed in conduit)
HL=LumaWatt Fixture Control Module (Allows low voltage 8
control wire to be daisy-chained between fixtures outside
AC conduit run similar to low voltage intercom's, fire
alarms and phone systems)
DL=UL Labeled for Damp Locations
NOTE: Specifications and dimensions subject to change without notice.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801