COOPER LIGHTING - LUMARK ® DESCRIPTION LumaWatt motion detectors work in conjunction with the LumaWatt controller and fixture dimmers to provide bilevel lighting control based upon an area's occupancy. Motion detectors are passive infrared type and react to changes in infrared energy (heat) within the coverage area. Excellent for controlling energy costs in any area occupied less than 100% of the time. Rated for use in 55°C (131°F) ambient environment (performance will degenerate at ambient temperatures above 35°C (95°F), requiring higher sensitivity settings and shortening coverage areas). Type Catalog # Project Date Comments Prepared by S P E C I F I C AT I O N F E AT U R E S Electrical 24 Volt DC OUTPUT: Low voltage output controls up to 25 LumaWattequipped fixtures. CONTROL #2 OUTPUT: Allow daisy-chaining of multiple controllers. MOTION DETECTOR INPUTS: Terminal block provides input connections for one to six passive infrared motion sensors. REMOTE SWITCH INPUT: Input terminal allows use of usersupplied dry-contact switch. Switch overrides motion sensors, putting system into high brightness mode. In absence of motion detectors, switch provides manual high-low control. Consult Technical Services for 1000W applications. TRANSFORMER: Standard transformer accepts 120V or 277V user-configurable input. 208V, 240V, 347V and 480V are also available. LED INDICATOR LIGHTS: Three front panel lights show system status: amber indicates that the controller is receiving power, red indicates that output from the controller is at full brightness and green indicates that output is at low brightness. BI-LEVEL FUNCTION SWITCH: Front panel switch provides same function as remote dry-contact switch. INITIALIZING TIMER: CMOS timer maintains system in full brightness mode for a 15 minute warm-up period when power is applied. IRMD HID MOTION DETECTOR HID INDOOR DIMENSIONS T E C H N I C A L D ATA 55 Degree C Maximum Ambient E N E R G Y D ATA 3 5/16” [84mm] 4” [102mm] 2 1/4” [57mm] 2” [51mm] 2” [51mm] CWA Ballast High/Low Input Watts 150W HPS HPF (196/118 Watts) 250W HPS HPF (300/151 Watts) 400W HPS HPF (465/215 Watts) 1000W HPS HPF (1100/616 Watts) 175W MH HPF (210/101 Watts) 250W MH HPF (295/162 Watts) 400W MH HPF (455/238 Watts) 1000W MH HPF (1080/666 Watts) 3 5/16” [84mm] 4” [102mm] ADH041468 pc 2010-11-03 12:48:14 IRMD HID MOTION DETECTOR C OV E R AG E PATT E R N S ORDERING INFORMATION Sample Number: IRMD-N-24V Product Family 1, 2 IRMD=LumaWatt Infrared Motion Detector Coverage A=Aisleway Input Voltage 24V=24V 3 N=Narrow W=Wide Notes: 1 System utilizes a 30 second time delay in switching between power levels. 2 See separate cutsheet for full details on control module. 3 Products also available in non-US voltages and 50HZ for international markets. Consult factory for availabiltiy and ordering information. NOTE: Specifications and dimensions subject to change without notice. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH041468 pc 2010-11-03 12:48:14 2010-11-03 13:11:26