DESCRIPTION
LumaWatt motion detectors work in conjunction with the LumaWatt
controller and fixture dimmers to provide bilevel lighting control based
upon an area's occupancy. Motion detectors are passive infrared type
and react to changes in infrared energy (heat) within the coverage area.
Excellent for controlling energy costs in any area occupied less than
100% of the time. Rated for use in 55°C (131°F) ambient environment
(performance will degenerate at ambient temperatures above 35°C (95°F),
requiring higher sensitivity settings and shortening coverage areas).
Type
Catalog #
Project
Date
Comments
Prepared by
S P E C I F I C AT I O N F E AT U R E S
Electrical
24 Volt DC OUTPUT: Low voltage
output controls up to 25 LumaWattequipped fixtures. CONTROL #2
OUTPUT: Allow daisy-chaining of
multiple controllers. MOTION
DETECTOR INPUTS: Terminal block
provides input connections for one
to six passive infrared motion
sensors. REMOTE SWITCH INPUT:
Input terminal allows use of usersupplied dry-contact switch. Switch
overrides motion sensors, putting
system into high brightness mode.
In absence of motion detectors,
switch provides manual high-low
control. Consult Technical Services
for 1000W applications.
TRANSFORMER: Standard
transformer accepts 120V or 277V
user-configurable input. 208V, 240V,
347V and 480V are also available.
LED INDICATOR LIGHTS: Three
front panel lights show system
status: amber indicates that the
controller is receiving power, red
indicates that output from the
controller is at full brightness and
green indicates that output is at
low brightness. BI-LEVEL
FUNCTION SWITCH: Front panel
switch provides same function as
remote dry-contact switch.
INITIALIZING TIMER: CMOS timer
maintains system in full brightness
mode for a 15 minute warm-up
period when power is applied.
IRMD
HID MOTION
DETECTOR
HID INDOOR
DIMENSIONS
T E C H N I C A L D ATA
55 Degree C Maximum Ambient
E N E R G Y D ATA
3 5/16”
[84mm]
4”
[102mm]
2 1/4” [57mm]
2” [51mm]
2” [51mm]
CWA Ballast High/Low Input Watts
150W HPS HPF (196/118 Watts)
250W HPS HPF (300/151 Watts)
400W HPS HPF (465/215 Watts)
1000W HPS HPF (1100/616 Watts)
175W MH HPF (210/101 Watts)
250W MH HPF (295/162 Watts)
400W MH HPF (455/238 Watts)
1000W MH HPF (1080/666 Watts)
3 5/16” [84mm]
4” [102mm]
ADH041468 pc
2010-11-03 12:48:14
IRMD
HID MOTION DETECTOR
C OV E R AG E PATT E R N S
ORDERING INFORMATION
Sample Number: IRMD-N-24V
Product Family 1, 2
IRMD=LumaWatt Infrared Motion Detector
Coverage
A=Aisleway
Input Voltage
24V=24V
3
N=Narrow
W=Wide
Notes:
1 System utilizes a 30 second time delay in switching between power levels. 2 See separate cutsheet for full details on control module. 3 Products also available in non-US
voltages and 50HZ for international markets. Consult factory for availabiltiy and ordering information.
NOTE: Specifications and dimensions subject to change without notice.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
ADH041468 pc
2010-11-03 12:48:14
2010-11-03 13:11:26
Download