COOPER LIGHTING - METALUX ® DESCRIPTION The HBE series is an outstanding value for mounting heights greater than 40 feet. The HBE optic has been optimized to provide maximum performance from T5HO lamps. Optional uplight component is provided to enable excellent ceiling uniformity. HBE‘s high lumen package allows the benefits of fluorescent to be applied at high mounting heights that were traditionally exclusive to H.I.D. The primary benefits include exceptional color rendering, high system efficacy, 95% lumen maintenance, long lamp life, instant on/instant re-strike, economical dimming, and uniform brightness control. Primary applications include "big box" retail, shopping malls, light industrial, etc. Type Catalog # Project Date Comments Prepared by S P E C I F I C AT I O N F E AT U R E S C o n s t ru c t i o n Full body construction is achieved with channel and end plates, along w/stiffening brackets and side rails to help create a strong, clean finished frame for this luminaire. Side rails are standard on all HBE products. Finish White enamel finish preceded by a multistage cleaning cycle, iron phosphate coating with rust inhibitor to protect against contaminants and oxidation. Optics Die formed, segmented optical design optimizes performance across three distributions. Optical choices include a narrow distribution for aisles, medium distribution for assembly and loading areas, or wide distribution for general, open area lighting. An uplight option is offered to permit ceiling uniformity and allow for ample lamp and luminaire heat dissipation. E l e c t ri c a l The HBE comes with a standard Class "P" electronic ballast and twist-lock lampholders. UL/cUL listed for high ambient environments up to 55°C (131°F) for all lamp and ballast combinations when used in open uplight configurations. Suitable for damp locations. Shielding Door frame and lens assembly is optional for more demanding environments. Options Integral Occupancy Sensor available and provides from 600 sq. ft. and up to 1250 sq. ft. of coverage in a maximum mounting height of 40' using interchangeable lens caps provided. Mounting The HBE series is ideally suited for suspension mounting with optional wire hook and chain set, or cable mounting. Single monopoint mounting is also available with SPM tong hanger. HBE SERIES 2 5 " X 4 8 " H I G H - B AY 8 O R 10 T 5 H O L A M P S High-Bay Efficiency Fluorescent Luminaire 2-15/32" [63mm] 25-11/32" [644mm] E N E R G Y D ATA D I M E N S I O N TO P V I E W L A M P C O N F I G U R AT I O N S 8/10 LAMP 8 LAMP 48-7/16" [1230mm] 2-15/32" [63mm] X=2-1/4" [57mm] 20-11/32" [517mm] X X X 25-11/32" [644mm] X X 24-19/32" [625mm] Input Watts: ER Ballast 854 (450), 1054 (566) X Luminaire Efficacy Rating LER = 74 (Narrow Beam) Catalog Number: HBE-854T5-UPL 10 LAMP 25-11/32" [644mm] 2-15/32" [63mm] X=1-7/8" [48mm] X X X X X 25-11/32" [644mm] X X X *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. **Consult Pre Sales Technical Support. LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. ADF091710 pc 2011-03-30 09:41:11 HBE T5HO P H OTO M E T R I C S HBE-854T5-N-UNVEBT2-UPL (2) Electronic Ballasts (8) F54T5 54W lamps 4400 lumens Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.1 x mounting height Efficiency 94.0% Test Report: HBE854N-UPL.IES LER =71 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.38 Candela Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Across ⊥ 10951 11145 11247 11140 10744 9544 8110 7342 6673 6210 5669 5021 4688 4228 3913 3552 2342 959 9 Along II 45° 10951 10951 10984 11064 10903 11152 10700 11067 10369 10834 9921 10373 9365 9511 8714 8103 7984 6885 7200 6077 6376 5356 5508 4797 4615 4174 3690 3565 2762 3128 1869 2710 1035 2266 326 996 8 12 C o e f fi c i e n t s o f U t i l i z a t i o n rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 110 100 91 83 76 70 65 60 56 52 49 110 95 83 73 65 58 52 47 43 40 37 110 91 76 65 56 49 44 39 35 32 29 110 87 71 59 50 43 38 33 30 27 24 107 97 88 80 73 67 62 58 54 51 47 107 93 81 71 63 56 51 46 42 39 36 107 89 75 64 55 48 43 38 35 32 29 107 85 69 58 49 43 37 33 30 27 24 20% 50% 50 30 10 30% 50 30 10 50 101 87 76 67 60 54 48 44 41 37 35 95 83 72 64 57 51 46 42 39 36 33 90 78 68 60 54 49 44 40 37 34 32 101 84 71 61 53 47 42 37 34 31 28 101 82 67 56 48 41 36 32 29 26 24 95 80 68 59 51 45 40 36 33 30 27 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 8780 13886 23440 30822 33096 %Lamp 24.9 39.4 66.6 87.6 94.0 %Fixture 26.5 42.0 70.8 93.1 100.0 Average 0-Deg cd/sm 14024 13226 12025 9946 5152 95 78 64 54 46 40 36 32 28 26 23 Average 45-Deg cd/sm 11837 11519 11618 14421 15739 10% 30 10 90 76 65 56 49 44 39 35 32 29 27 90 74 62 53 45 39 35 31 28 25 23 0% 0 88 72 60 50 43 37 33 29 26 23 21 Average 90-Deg cd/sm 12096 12057 13779 18902 15155 Modular F-Bay Power Supply Option Cooper Lighting’s F-Bay Modular Power Supply option is available for use with all F-Bay products. The modular power supply allows external fixture access for safe and easy servicing. There is no need to remove lamps or reflectors to disconnect fixture power with F-Bay Modular Power Supply. Access to the individual fixture’s power supply allows servicing without turning off all the fixtures, disrupting occupants. F-Bay Modular Power Supply is a time-saver in installation – simply plug & power. Code Compliance • UL/cUL Certified for Make/Break under load (UL2549) • Meets NEC requirements for ballast disconnect (NEC 410.73G) 1 • Allows for addition of Occupancy Sensor without hard connections 2 1. Modular Power Supply Receptacle supplied mounted into fixture Access Plate 2. Modular Power Cord & Plugs in 120, 277, 347, & 480V configurations for easy plug & power into existing supply No internal fixture access required for installation or disconnecting power Modular Motion Sensor Option supplied with Mounting Box and Modular Power Supply Receptacle • Receptacles complete with insulating/dust cap Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 ADF091710 pc 2011-03-30 09:41:11 HBE T5HO O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: HBE-854T5-N-A-UNV-L5850-EBT2-U Includes V Hangers for rapid installation(4) Voltage (1) UNV=Universal 120/277 Voltage UNC=Universal 347/480 Voltage 120V=120 Volt 277V=277 Volt 347V=347 Volt Series HBE=High Bay Efficiency No. of Lamps 8=8 Lamps (6) 10=10 Lamps (6) Lamp Type 49T5=49W T5HO Lamps (48") 51T5=51W T5HO Lamps (48") 54T5=54W T5HO Lamps (48") Options Lamps Installed L5830=T5 Lamp, 80CRI 3000K L5835=T5 Lamp, 80CRI 3500K L5841=T5 Lamp, 80CRI 4100K L5850=T5 Lamp, 80CRI 5000K GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed (1) Distribution N=Narrow Beam (Standard) M=Medium Beam W=Wide Beam Ballast Type EBT =T5HO Linear Electronic Program Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EHT =T5HO Linear Electronic Program Start High Ambient. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 Shielding (6) Blank=None A=Prismatic Acrylic Lens & Doorframe WG=Wireguard & Doorframe CL=Clear Acrylic Lens & Doorframe A/WG=Acrylic Lens, Wireguard & Doorframe CL/WG=Clear Lens, Wireguard & Doorframe (1) (2) NOTES: Voltage must be specified when ordered with plugs or emergency ballasts. When ordering MS option, specify as UNV (for 120 or 277V), (3) 347 or 480V. Requires use of MC or MPC cord accessories, specify voltage for plugs. (4) Can be used in high abuse applications such as gymnasiums. (5) EHT/HT5/HCT5 ballast systems suitable for ambient environments not to exceed 149°F (65°C) in open uplight configurations and less lens (6) option. EHT ballast recommended when using lens option on 8 or 10 lamp configurations. (7) Cannot be combined with Modular Power Receptacle (MP). (8) For MWS with MP, choose MP in fixture logic and then choose MWS accessory such as MDS6 Packaging Options U=Unit Pack Blank=Side Rails (Standard) PALC=Job Pack MP=Modular Power In Carton Receptacle (Used for all Cord (3), (8) PAL=Job Pack or Cord and Plug options) UPL=Uplight Apertures on Out of Carton Reflector (7) MWS=Modular Wiring System MS=360° or 180° motion sensor installed, 120V through 347V, or 480V (2) Accessories (order separately) HBL-SPM=Single Monopoint Hanger w/Hub RH-1=Retrofit Hanger FH-1=Fixture Hook FL-1=Fixture Loop Y-TOGGLE=Y Mounting Toggle, #2 Cable (Specify 10' or 30', requires 2 per fixture) HBAYC-CHAIN/SET/U=(2) V-Hook Hangers, 36" Chain Sets w/S-Hooks MC3=3' Modular Power Cord MPC3=3' Modular Power Cord & Plug (Specify Voltage) MC6=6' Modular Power Cord MPC6=6' Modular Power Cord & Plug (Specify Voltage) MMS=360° or 180° Aisle Motion Sensor with Modular Power Receptacle (120-277V) (2) MDS6=6' Modular Power Cord with MWS 27DS18/2G06MP Connector (8) WG/HBL8-4FT-B=8 Lamp Wireguard w/Clips S H I P P I N G DATA Catalog No. HBE-854T5-A HBE-1054T5-A Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 Wt. 25 lbs. 25 lbs. ADF091710 pc 2011-03-30 09:41:11