COOPER LIGHTING - METALUX

advertisement
COOPER LIGHTING - METALUX
®
DESCRIPTION
The HBE series is an outstanding value for high mounting height
industrial or retail applications. The HBE optic has been optimized to
provide maximum performance from T5 lamps. Optional uplight
component is provided to enable excellent ceiling uniformity. HBE‘s high
lumen package allows the benefits of fluorescent to be applied at high
mounting heights that were traditionally exclusive to HID. The primary
benefits include exceptional color rendering, high system efficacy, 95%
lumen maintenance, long lamp life, instant on/instant re-strike,
economical dimming, and uniform brightness control. Primary
applications include "big box" retail, shopping malls, light industrial, etc.
Type
Catalog #
Project
Date
Comments
Prepared by
S P E C I F I C AT I O N F E AT U R E S
C o n s t ru c t i o n
Full body construction is achieved
with channel and end plates, along
w/stiffening brackets and side rails
to help create a strong, clean
finished frame for this luminaire.
Side rails are standard on all HBE
products.
inhibitor to protect against
contaminants and oxidation.
Optics
Die-formed, segmented optical
design optimizes performance
across three distributions. Optical
choices include a narrow
distribution for aisles, medium
distribution for assembly and
loading areas, or wide distribution
for general, open area lighting. An
uplight option is offered to permit
ceiling uniformity and allow for
ample lamp and luminaire heat
dissipation.
E l e c t ri c a l
The HBE comes with a standard
Class "P" electronic ballast and
twist-lock lampholders. UL/cUL
listed for high ambient
environments up to 55°C (131°F)
for all lamp and ballast
combinations when used in open
uplight configurations. Suitable for
damp locations.
Shielding
Door frame and lens assembly is
optional for more demanding
environments.
Finish
White enamel finish preceded by a
multistage cleaning cycle, iron
phosphate coating with rust
Options
Integral Occupancy Sensor
available and provides from 600
sq. ft. and up to 1250 sq. ft. of
coverage in a maximum mounting
height of 40' using interchangeable
lens caps provided.
Mounting
The HBE series is ideally suited for
suspension mounting with optional
wire hook and chain set, or cable
mounting. Single monopoint
mounting is also available with
SPM tong hanger. Includes V
Hangers for rapid installation.
Wa rra n t y
When operated in high ambient
conditions, the HBI is supported by
a 5 yr/55°C and 3 yr/65°C ballast
warranty when used with a high
ambient ballast in open, uplight
configurations (T5HO lamping
only).
2-15/32"
[63mm]
HBE
SERIES
2 0 " X 4 8 " H I G H - B AY
U LT R A 4 7
4 OR 6
T5HO LAMPS
2 5 " X 4 8 " H I G H - B AY
U LT R A 4 7
8 O R 10
T5HO LAMPS
High-Bay Efficiency
Fluorescent Luminaire
20-1/4" [512mm]
L A M P C O N F I G U R AT I O N S
D I M E N S I O N TO P V I E W
4 LAMP
4 or 6 LAMP
48-7/16" [1231mm]
2-15/32" [63mm]
X
X=3-1/2"
[89mm]
X
20-1/4" [512mm]
E N E R G Y D ATA
20-1/4"
[512mm]
6 LAMP
Input Watts:
EHT Ballast
647 = 311
2-15/32" [63mm]
Y
Y=2-3/8"
[61mm]
Y
Y
Y
20-1/4" [512mm]
Luminaire Efficacy Rating
LER = 82 (Narrow Beam)
Catalog Number: HBE-647T5-UPL
D I M E N S I O N TO P V I E W
L A M P C O N F I G U R AT I O N S
8/10 LAMP
8 LAMP
48-7/16" [1230mm]
2-15/32" [63mm]
20-11/32" [517mm]
X
X=2-1/4"
[57mm]
X
X
X
25-11/32" [644mm]
X
24-19/32" [625mm]
X
*Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
**Consult Pre Sales Technical Support.
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
10 LAMP
2-15/32" [63mm]
X=1-7/8"
[48mm]
X
X
X
X
X
25-11/32" [644mm]
X
X
X
25-11/32"
[644mm]
Safe and convenient means of
disconnecting power.
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADF110939 pc
2011-05-17 13:24:36
HBE T5HO
P H OTO M E T R I C S
HBE-447T5-UNV
(1) Electronic Ballast
(4) F54T5-47W lamps
4285 lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 0.7 x
mounting height
Efficiency 99.3%
Test Report:
HBE447-UPL.IES
LER=83
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $2.89
Candela
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
C o e f fi c i e n t s o f U t i l i z a t i o n
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
118
105
93
83
74
67
61
56
52
48
45
118
101
87
75
66
59
53
48
44
40
37
118
98
82
69
60
53
47
42
38
35
32
115
107
98
90
83
77
72
67
63
59
56
115
103
91
81
73
66
60
55
51
47
44
115
99
85
74
65
58
52
48
43
40
37
115
96
81
69
60
52
47
42
38
35
32
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
110
99
88
78
71
64
58
54
50
46
43
106
95
84
76
68
62
57
52
49
45
42
101
91
82
73
66
60
55
51
47
44
41
99
86
73
63
55
49
44
39
36
33
30
110
96
83
72
64
57
52
47
43
39
37
110
93
79
68
59
52
46
42
38
35
32
106
93
81
71
63
56
51
46
42
39
36
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
6299
9233
14204
17022
17022
%Lamp
36.7
53.9
82.9
99.3
99.3
Candela
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Across ⊥
10884
10658
9795
8645
7522
6483
5883
5653
5208
4666
4322
3911
3492
3023
2632
2037
1431
599
39
Along II
45°
10884
10884
10787
10710
10619
10181
10352
9367
9987
8378
9548
7412
9020
6452
8422
5591
7746
5046
7008
4716
6218
4186
5369
3594
4493
3175
3565
2683
2615
2204
1693
1788
854
1224
235
596
3
37
C o e f fi c i e n t s o f U t i l i z a t i o n
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
118
109
100
92
85
79
73
69
64
60
57
HBE-647T5-UNV-UPL
(2) Electronic Ballasts
(6) F54T5-47W lamps
4285 lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 0.8 x
mounting height
Efficiency 99.5%
Test Report:
HBE647-UPL.IES
LER=82
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $2.92
Across ⊥
10037
9918
9166
7664
5887
4392
3681
3333
2993
2738
2485
2226
2144
1882
1286
645
106
0
5
Along II
45°
10037
10037
9943
9932
9777
9528
9525
8737
9182
7506
8765
6096
8274
4733
7713
3690
7074
3149
6389
2771
5633
2401
4852
2105
4038
1820
3183
1544
2312
1389
1471
901
734
347
169
2
4
2
%Fixture
37.0
54.2
83.4
100.0
100.0
Average
0-Deg
cd/sm
19774
18513
16483
12438
4244
106
90
77
66
58
51
46
41
38
35
32
101
90
78
69
61
55
50
45
42
39
36
101
88
75
65
57
51
46
41
38
34
32
Average
45-Deg
cd/sm
8576
8032
7995
7619
50
Average
90-Deg
cd/sm
8474
8493
9746
5454
50
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
117
107
97
89
81
75
69
64
60
56
53
117
102
89
78
70
62
56
51
47
43
40
117
97
82
70
61
54
48
43
39
35
32
117
94
76
64
54
47
41
37
33
30
27
113
103
94
86
78
72
67
62
58
54
51
113
99
86
76
68
61
55
50
46
42
39
113
95
80
69
60
53
47
42
38
35
32
113
91
75
63
54
47
41
36
33
30
27
20%
50%
50 30 10
30%
50 30 10
50
107
93
82
72
64
58
53
48
44
41
38
101
88
77
69
61
55
50
46
42
39
36
95
84
74
65
58
53
48
44
41
38
35
107
90
77
66
58
51
45
41
37
34
31
107
87
72
61
52
45
40
36
32
29
27
101
86
73
63
55
49
44
40
36
33
30
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
7212
11157
18599
23829
25586
%Lamp
28.0
43.4
72.3
92.7
99.5
%Fixture
28.2
43.6
72.7
93.1
100.0
Average
0-Deg
cd/sm
21690
20485
18461
14315
5901
101
83
70
59
51
44
39
35
31
29
26
10%
30 10
95
82
70
61
53
47
43
39
35
32
30
0%
0
95
80
67
57
49
43
38
34
31
28
26
Average
45-Deg
cd/sm
14596
13713
13894
15119
14966
93
77
65
55
47
41
36
32
29
26
24
Average
90-Deg
cd/sm
14441
14922
15654
17224
15041
Modular F-Bay Power Supply Option
Cooper Lighting’s F-Bay Modular Power Supply option is available for use with all F-Bay products. The modular power supply
allows external fixture access for safe and easy servicing. There is no need to remove lamps or reflectors to disconnect fixture
power with F-Bay Modular Power Supply. Access to the individual fixture’s power supply allows servicing without turning off
all the fixtures, disrupting occupants. F-Bay Modular Power Supply is a time-saver in installation – simply plug & power.
Code Compliance
• UL/cUL Certified for Make/Break
under load (UL2549)
• Meets NEC requirements for
ballast disconnect (NEC 410.73G)
1
• Allows for addition of Occupancy
Sensor without hard connections
2
1. Modular Power Supply Receptacle supplied
mounted into fixture Access Plate
2. Modular Power Cord & Plugs in 120, 277, 347,
& 480V configurations for easy plug & power
into existing supply
No internal fixture
access required for
installation or
disconnecting power
Modular Motion Sensor Option
supplied with Mounting Box and
Modular Power Supply Receptacle
• Receptacles complete with
insulating/dust cap
Specifications and dimensions subject to change without notice.
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801
ADF110939 pc
2011-05-17 13:24:36
HBE T5HO
O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: HBE-647T5-N-A-UNV-L5850-EHT2-U
Voltage 1
UNV=Universal
120/277 Voltage
120V=120 Volt
277V=277 Volt
Series
HBE=High Bay
Efficiency
No. of Lamps
4=4 Lamps
6=6 Lamps
8=8 Lamps
10 =10 Lamps
Lamps Installed 5
L5841=T5 Lamp, 85CRI 4100K
L5850=T5 Lamp, 85CRI 5000K
Lamp Type
47T5=47W T5HO Lamps (48")
Ballast Type
Distribution
N=Narrow Beam (Standard)
M=Medium Beam
W=Wide Beam
EHT =T5HO Linear Electronic Program
Rapid Start High Ambient.
Total Harmonic Distortion < 10% 4
No. of Ballast
1, 2 or 3
Options
Blank=Side Rails (Standard)
MP=Modular Power
Receptacle (Used for
all Cord or Cord and Plug
options) 3
UPL=Uplight Apertures on
Reflector
6
MWS=Modular Wiring System
Packaging
U=Unit Pack
PALC =Job Pack In Carton
PAL=Job Pack Out of Carton
Shielding
Blank=None
A=Prismatic Acrylic Lens & Doorframe
WG=Wireguard
CL=Clear Acrylic Lens & Doorframe
A/WG=Acrylic Lens, Wireguard & Doorframe
CL/WG=Clear Lens, Wireguard & Doorframe
Accessories (order separately)
HB-SPM =Single Monopoint Hanger w/Hub
RH-1=Retrofit Hanger
FH-1=Fixture Hook
FL-1=Fixture Loop
Y-TOGGLE=Y Mounting Toggle, #2 Cable (Specify
10' or 30', requires 2 per fixture) 7
HBAYC-CHAIN/SET/U=(2) V-Hook Hangers,
36" Chain Sets w/S-Hooks
MC3=3' Modular Power Cord
MPC3=3' Modular Power Cord & Plug (Specify
Voltage)
MC6=6' Modular Power Cord
MPC6=6' Modular Power Cord & Plug (Specify
Voltage)
MMS=360° or 180° Aisle Motion Sensor with
Modular Power Receptacle (120-277V) 1
MDS6=6' Modular Power Cord with MWS
27DS18/2G06MP Connector 8
WG/HBL6-4FT-B=4/6 Lamp w/Lamp Wireguard w/Clips
WG/HBL8-4FT-B=8 Lamp w/Lamp Wireguard w/Clips
NOTES:
1 Voltage must be specified when ordered with plugs or emergency ballasts.
2 When ordering MS option, specify voltage as UNV (for 120 or 277V).
3 Requires use of MC or MPC cord accessories, specify voltage for plugs.
4 EHT/HT5/HCT5 ballast systems suitable for ambient environments not to exceed 149°F (65°C) in open uplight configurations and less lens option.
5 Must specify lamps when ordering.
6 Cannot be combined with Modular Power Receptacle (MP). For MWS with MP, choose MP in fixture logic and then choose MWS.
7 Two required.
8 For MWS with MP, choose MP in the fixture logic and then choose MWS accessory such as MDS6.
S H I P P I N G DATA
Catalog No.
HBE-647T5
Specifications and dimensions subject to change without notice.
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801
Wt.
18 lbs.
ADF110939 pc
2011-05-17 13:24:36
Download