COOPER LIGHTING - METALUX ® DESCRIPTION The HBE series is an outstanding value for mounting heights greater than 40 feet. The HBE optic has been optimized to provide maximum performance from T8 lamps. Optional uplight component is provided to enable excellent ceiling uniformity. HBE‘s high lumen package allows the benefits of fluorescent to be applied at high mounting heights that were traditionally exclusive to H.I.D. The primary benefits include exceptional color rendering, high system efficacy, 95% lumen maintenance, long lamp life, instant on/instant re-strike, economical dimming, and uniform brightness control. Primary applications include "big box" retail, shopping malls, light industrial, etc. Type Catalog # Project Date Comments Prepared by S P E C I F I C AT I O N F E AT U R E S C o n s t ru c t i o n Full body construction is achieved with channel and end plates, along w/stiffening brackets and side rails to help create a strong, clean finished frame for this luminaire. Side rails are standard on all HBE products. Finish White enamel finish preceded by a multistage cleaning cycle, iron phosphate coating with rust inhibitor to protect against contaminants and oxidation. Optics Die formed, segmented optical design optimizes performance across three distributions. Optical choices include a narrow distribution for aisles, medium distribution for assembly and loading areas, or wide distribution for general, open area lighting. An uplight option is offered to permit ceiling uniformity and allow for ample lamp and luminaire heat dissipation. E l e c t ri c a l The HBE comes with a standard Class "P" electronic ballast and twist-lock lampholders. UL/cUL listed for high ambient environments up to 55°C (131°F) for all lamp and EB/PLUS or ER/PLUS ballast combinations when used in open uplight configurations. Suitable for damp locations. Shielding Door frame and lens assembly is optional for more demanding environments. Options Integral Occupancy Sensor available and provides from 600 sq. ft. and up to 1250 sq. ft. of coverage in a maximum mounting height of 40' using interchangeable lens caps provided. Mounting The HBE series is ideally suited for suspension mounting with optional wire hook and chain set, or cable mounting. Single monopoint mounting is also available with SPM tong hanger. HBE SERIES 2 5 " X 4 8 " H I G H - B AY 8 O R 10 T 8 L A M P S High-Bay Efficiency Fluorescent Luminaire 2-15/32" [63mm] 25-11/32" [644mm] E N E R G Y D ATA L A M P C O N F I G U R AT I O N S D I M E N S I O N TO P V I E W 8 LAMP 8/10 LAMP 48-7/16" [1230mm] 2-15/32" [63mm] X=2-1/4" [57mm] 20-11/32" [517mm] X X X 25-11/32" [644mm] X X 24-19/32" [625mm] X Input Watts: EB Ballast 832 (218), 1032 (270) EB/Plus Ballast 832 (290), 1032 (363) ER Ballast 832 (224), 1032 (282) ER/Plus Ballast 832 (288), 1032 (362) Luminaire Efficacy Rating LER = 90 (Narrow Beam) Catalog Number: HBE-832-UPL 10 LAMP 25-11/32" [644mm] 2-15/32" [63mm] X=1-7/8" [48mm] X X X X X 25-11/32" [644mm] X X X *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. **Consult Pre Sales Technical Support. LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. ADF091709 pc 2011-03-30 09:42:32 HBE T8 P H OTO M E T R I C S P H OTO M E T R I C S HBE-832-N-A-UPL HBE-832-N-UPL Candela (2) Electronic Ballasts (8) 32W T8 Lamps 2850 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.1 x mounting height Efficiency 72.8% Test Report: HBE832-A-UPL.IES LER =FL73 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.28 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 6785 6738 6626 6445 6176 5835 5414 4910 4314 3659 2963 2325 1763 1286 930 674 495 271 20 Across ⊥ 6785 6720 6519 6188 5783 5393 5033 4679 4283 3776 3179 2549 1924 1384 996 771 576 317 65 45° 6785 6726 6574 6312 5953 5526 5087 4630 4117 3541 2966 2396 1770 1179 742 519 409 238 41 C o e f fi c i e n t s o f U t i l i z a t i o n rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 85 75 66 59 53 47 43 39 36 33 31 85 72 62 54 47 41 37 33 30 27 25 85 70 58 49 42 37 32 29 26 23 21 82 76 69 64 59 54 50 47 44 41 38 82 73 64 57 51 46 42 38 35 32 30 82 70 60 52 46 41 36 33 30 27 25 82 68 57 48 42 36 32 28 26 23 21 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 77 69 61 54 49 44 40 37 34 31 29 72 65 58 51 46 42 38 35 32 30 28 68 61 55 49 44 40 36 33 31 29 27 66 57 48 42 36 32 28 25 23 21 19 77 67 58 50 44 39 35 32 29 26 24 77 65 55 47 40 35 32 28 25 23 21 72 63 55 48 42 38 34 31 28 25 23 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 4982 7923 12846 15091 16593 %Lamp 21.9 34.7 56.3 66.2 72.8 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 7207 7180 7059 6858 6586 6281 5941 5583 5181 4711 4184 3613 2998 2374 1755 1183 636 198 8 Across ⊥ 7207 7058 6815 6517 6037 5277 4682 4478 4389 4332 4084 3646 3447 3038 2399 1731 1084 473 8 45° 7207 7107 6889 6641 6334 5914 5269 4548 4020 3765 3564 3362 2995 2570 2269 1692 1061 459 8 C o e f fi c i e n t s o f U t i l i z a t i o n Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 85 78 72 66 61 56 52 48 45 42 40 Candela (2) Electronic Ballasts (8) 32W T8 Lamps 2850 lumens Spacing criterion: (II) 1.2 x mounting height, (⊥) 1.1 x mounting height Efficiency 89.9% Test Report: HBE832N-UPL.IES LER =FL82 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.93 %Fixture 30.0 47.7 77.4 91.0 100.0 Average 0-Deg cd/sm 6618 5184 3891 3330 3980 72 62 52 45 39 34 31 27 25 22 20 68 60 52 46 41 36 33 30 27 25 23 68 59 50 44 38 34 30 27 24 22 20 Average 45-Deg cd/sm 6405 5343 3567 2563 3493 Average 90-Deg cd/sm 6830 5683 4187 3811 4644 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 106 96 87 79 72 67 61 57 53 50 47 106 92 79 69 61 55 49 45 41 38 35 106 106 87 84 73 68 62 56 53 47 47 41 41 35 37 31 33 28 30 25 28 23 103 93 84 76 70 64 59 55 51 48 45 103 89 77 68 60 53 48 44 40 37 34 103 85 71 61 52 46 41 36 33 30 27 20% 103 82 66 55 47 40 35 31 28 25 23 50% 50 30 10 30% 50 30 10 50 97 84 73 64 57 51 46 42 38 35 33 91 79 69 61 54 48 44 40 37 34 31 86 75 66 58 51 46 42 38 35 33 30 97 81 68 58 50 44 39 35 32 30 27 97 78 64 53 45 39 34 30 27 24 22 91 77 65 56 49 43 38 34 31 28 26 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 5225 8250 14471 19168 20501 %Lamp 22.9 36.2 63.5 84.1 89.9 %Fixture 25.5 40.2 70.6 93.5 100.0 Average 0-Deg cd/sm 8520 8055 7184 5843 2899 91 75 62 52 44 38 34 30 27 24 22 10% 30 10 86 73 62 54 47 41 37 33 30 27 25 86 72 59 50 43 37 33 29 26 24 22 Average 45-Deg cd/sm 9217 7497 7777 8362 6733 0% 0 84 69 57 48 41 35 31 27 24 22 20 Average 90-Deg cd/sm 9217 8129 9194 8555 6945 Modular F-Bay Power Supply Option Cooper Lighting’s F-Bay Modular Power Supply option is available for use with all F-Bay products. The modular power supply allows external fixture access for safe and easy servicing. There is no need to remove lamps or reflectors to disconnect fixture power with F-Bay Modular Power Supply. Access to the individual fixture’s power supply allows servicing without turning off all the fixtures, disrupting occupants. F-Bay Modular Power Supply is a time-saver in installation – simply plug & power. Code Compliance • UL/cUL Certified for Make/Break under load (UL2549) • Meets NEC requirements for ballast disconnect (NEC 410.73G) 1 • Allows for addition of Occupancy Sensor without hard connections 2 1. Modular Power Supply Receptacle supplied mounted into fixture Access Plate 2. Modular Power Cord & Plugs in 120, 277, 347, & 480V configurations for easy plug & power into existing supply No internal fixture access required for installation or disconnecting power Modular Motion Sensor Option supplied with Mounting Box and Modular Power Supply Receptacle • Receptacles complete with insulating/dust cap Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 ADF091709 pc 2011-03-30 09:42:32 HBE T8 O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: HBE-832-N-A-UNV-L8850-EB82/PLUS-U Ballast Type (4) EB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 /PLUS=T8 Electronic Instant Start. (10) High Ballast Factor >1.15. No. of Total Harmonic Distortion < 10% Ballast 1, 2 or 3 ER8 =T8 Electronic Program Rapid Start.(7) Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 ER8 /PLUS=T8 Electronic Program Start.(7) High Ballast Factor >1.15. No. of Total Harmonic Distortion < 10% Ballast 1, 2 or 3 Voltage (1) UNV=Universal 120/277 Voltage UNC=Universal 347/480 Voltage (EB8/PLUS only) (10) 120V=120 Volt 277V=277 Volt 347V=347 Volt Series HBE=High Bay Efficiency No. of Lamps 8=8 Lamps 10=10 Lamps Lamp Type 32=32W T8 Lamps (48") Distribution N=Narrow Beam (Standard) M=Medium Beam W=Wide Beam Shielding (6) Blank=None A=Prismatic Acrylic Lens & Doorframe WG=Wireguard & Doorframe CL=Clear Acrylic Lens & Doorframe A/WG=Acrylic Lens, Wireguard & Doorframe CL/WG=Clear Lens, Wireguard & Doorframe (1) Includes V Hangers for rapid installation(5) Options Lamps Installed L8830=T8 Lamp, 80CRI 3000K L8835=T8 Lamp, 80CRI 3500K L8841=T8 Lamp, 80CRI 4100K L8850=T8 Lamp, 80CRI 5000K HL=Add HL at end of lamp for high lumen lamps GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed (1) (2) NOTES: Voltage must be specified when ordered with plugs, motion sensor or emergency ballasts. When ordering MS option, specify as UNV (for 120 or (3) 277V), 347 or 480V. Requires use of MC or MPC cord accessories, specify voltage for plugs. (4) T8 ballast systems suitable for operation in ambient environments up to 131°F (55°C) in open uplight configuration. (5) Can be used in high abuse applications such as gymnasiums. (6) Not recommended in 10 lamp configurations at ambient temperatures above 102°F (40°C). (7) Recommended when utilizing motion sensor options. (8) Cannot be combined with Modular Power Receptacle (MP). (9) For MWS with MP, choose MP in fixture logic and then choose MWS accessory such as MDS6. (10) 2/3 lamp ballast configuration in EB8/PLUS only for UNC version. Packaging Options U=Unit Pack Blank=Side Rails (Standard) PALC=Job Pack MP=Modular Power In Carton Receptacle (Used for all PAL=Job Pack Cord or Cord and Plug Out of Carton options )(3), (9) UPL=Uplight Apertures on Reflector MWS=Modular Wiring System (8) MS=360° or 180° motion sensor installed, 120V through 347V, or 480V (2) Accessories (order separately) HBL-SPM=Single Monopoint Hanger w/Hub RH-1=Retrofit Hanger FH-1=Fixture Hook FL-1=Fixture Loop Y-TOGGLE=Y Mounting Toggle, #2 Cable (Specify 10' or 30', requires 2 per fixture) HBAYC-CHAIN/SET/U=(2) V-Hook Hangers, 36" Chain Sets w/S-Hooks MC3=3' Modular Power Cord MPC3=3' Modular Power Cord & Plug (Specify Voltage) MC6=6' Modular Power Cord MPC6=6' Modular Power Cord & Plug (Specify Voltage) MMS=360° or 180° Aisle Motion Sensor with Modular Power Receptacle (120-277V) (3) MDS6=6' Modular Power Cord with MWS 27DS18/2G06MP Connector (9) WG/HBL8-4FT-B=8 Lamp Wireguard w/Clips S H I P P I N G DATA Catalog No. HBE-832 HBE-1032 Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 Wt. 18 lbs. 18 lbs. ADF091709 pc 2011-03-30 09:42:32