COOPER LIGHTING - METALUX DESCRIPTION The HBI series is an outstanding solution for high mounting height industrial or retail applications. The HBI optic has been optimized to provide maximum performance from T5 lamps. Optional uplight component is provided to enable excellent ceiling uniformity. HBI‘s high lumen package allows the benefits of fluorescent to be applied at high mounting heights that were traditionally exclusive to HID. The primary benefits include exceptional color rendering, high system efficacy, 95% lumen maintenance, long lamp life, instant on/instant re-strike, economical dimming, and uniform brightness control. Primary applications include retail, shopping malls, light industrial, gymnasiums and recreational environments. ® Type Catalog # Project Date Comments Prepared by S P E C I F I C AT I O N F E AT U R E S C o n s t ru c t i o n Full bodied steel housing with integral ballast channel adds strength, rigidity and structural protection for optical assembly. E l e c t ri c a l The HBI comes standard with a high ambient Class P electronic ballast and twistlock lampholders. UL/cUL listed for high ambient environments up to 65°C (149°F) for all lamps and ballast combinations when used in open uplight configurations. Suitable for damp locations. Optional modular power receptacle meets UL2459 and NEC 410.73 and is UL/cUL rated for make and break under load from outside the luminaire to speed maintenance. Finish White enamel finish preceded by a multistage cleaning cycle, iron phosphate coating with rust inhibitor to protect against contaminants and oxidation. D ow n l i g h t / U p l i g h t O p t i c s Die-formed, segmented optical design optimizes performance across three distributions. Optical choices include a narrow distribution for aisles, medium distribution for assembly and loading areas, or wide distribution for general, open area lighting. An uplight option is offered to permit ceiling uniformity and allow for ample lamp and luminaire heat dissipation. Gasketed door frame & lens assembly is optional for more demanding environments. Options Integral Occupancy Sensor available and provides from 600 sq. ft. (MS) up to 1250 sq. ft. (MSO) of coverage at a maximum mounting height of 40' using interchangeable lens caps provided. Mounting The HBI series is suited for suspension mounting with optional wire hook and chain set or cable mounting. Single monopoint mounting is available with SPM Tong Hanger. Includes V Hangers for rapid installation. Wa rra n t y When operated in high ambient conditions, the HBI is supported by a 5 yr/55°C and 3 yr/65°C ballast warranty when used with a high ambient ballast in open, uplight configurations (T5HO lamping only). HBI SERIES U LT R A 4 7 4, 5 OR 6 T5HO LAMPS High-Bay Industrial Fluorescent Luminaire 4-5/16" [109mm] E N E R G Y D ATA 16-3/4" [427mm] Input Watts: EHT Ballast 647=310W L A M P C O N F I G U R AT I O N S 6 LAMP Luminaire Efficacy Rating LER = 81 Catalog Number: HBI-647T5-N-UPL D I M E N S I O N TO P V I E W 7/8" [23mm] K.O. 1/2" [13mm] K.O. V-Hook Hanger Location Access Plate Opening 7/8" K.O. 1/4" [7mm] 3/8" [10mm] 4-5/16" [109mm] X=1-1/8" [28mm] Y=2-13/32" [61mm] Y Y X Y Y 16-3/4" [427mm] 16-3/4" [427mm] Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.96 *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. **Consult Pre Sales Technical Support. 2-3/8" [59mm] 3-3/8" [84mm] 48-1/8" [1222mm] LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS 24-3/8" [621mm] Safe and convenient means of disconnecting power. Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. ADF110940 pc 2012-01-30 14:08:00 HBI T5 P H OTO M E T R I C S HBI-447T5-UNV-UPL C a n d e l a (1) Electronic Ballast (4) F54T5-47W Lamps Angle Along II 0 9407 4285 lumens 5 9392 10 9228 Spacing criterion: 15 8969 (II) 1.2 x mounting 20 8641 height, (⊥) 0.7 x 25 8202 mounting height 30 7678 35 7107 Efficiency 92.8% 40 6465 Test Report: 45 5776 HBI447-UPL.IES 50 5001 55 4211 LER=77 60 3405 Yearly Cost of 1000 65 2583 70 1839 lumens, 3000 hrs at 75 1127 .08 KWH =$3.11 80 85 90 Across ⊥ 9407 9016 8140 6715 5197 3992 3240 2990 2708 2473 2270 2113 1831 1362 924 485 141 47 3 45° 9407 9251 8758 7866 6751 5530 4387 3456 2849 2512 2219 1945 1691 1409 1053 626 235 47 4 509 94 0 C o e f fi c i e n t s o f U t i l i z a t i o n rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 110 98 87 77 69 63 57 52 48 45 41 110 94 81 70 62 55 49 45 41 38 35 110 91 76 65 56 49 44 40 36 33 30 107 99 91 83 77 71 66 62 58 55 52 107 95 84 75 68 61 56 51 47 44 41 107 92 79 69 61 54 49 44 40 37 34 107 89 75 64 56 49 44 39 36 33 30 20% 50% 50 30 10 30% 50 30 10 50 101 90 81 72 65 59 54 50 46 43 40 96 86 77 69 62 57 52 48 44 41 39 91 82 74 66 60 55 50 46 43 40 38 101 88 76 67 59 53 48 43 40 36 34 101 86 73 63 55 48 43 39 35 32 30 96 84 74 65 57 52 47 42 39 36 33 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 5761 8438 12951 15227 15913 %Lamp 33.6 49.2 75.6 88.8 92.8 80 85 90 789 178 4 Across ⊥ 11297 11180 10296 8982 7767 6807 6049 5841 5347 4757 4242 3611 3107 2789 2190 1490 772 93 9 45° 11297 11220 10762 9871 8771 7694 6762 5891 5245 4908 4346 3714 3152 2509 2036 1560 877 291 3 C o e f fi c i e n t s o f U t i l i z a t i o n Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 110 101 93 86 79 74 68 64 60 56 53 HBI-647T5-UNV-UPL C a n d e l a (2) Electronic Ballasts (6) F54T5-47W Lamps Angle Along II 0 11297 4285 lumens 5 11176 10 10987 Spacing criterion: 15 10714 (II) 1.2 x mounting 20 10345 height, (⊥) 0.8 x 25 9889 mounting height 30 9351 35 8730 Efficiency 97.2% 40 8041 Test Report: 45 7286 HBI647-UPL.IES 50 6465 55 5583 LER=81 60 4638 Yearly Cost of 1000 65 3654 70 2627 lumens, 3000 hrs at 75 1655 .08 KWH =$2.96 %Fixture 36.2 53.0 81.4 95.7 100.0 Average 0-Deg cd/sm 17040 15315 12750 9084 2250 96 82 70 61 53 47 42 38 35 32 29 10% 30 10 91 81 71 63 56 50 45 42 38 35 33 91 79 68 59 52 46 42 38 34 32 29 Average 45-Deg cd/sm 7411 7074 6955 5046 1125 0% 0 89 77 66 57 50 45 40 36 33 30 28 Average 90-Deg cd/sm 7296 7685 6723 3909 1125 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 115 105 96 88 81 74 69 64 60 56 53 115 101 88 78 69 62 56 51 47 43 40 115 97 82 70 61 54 48 43 39 36 33 115 93 77 64 55 48 42 37 34 30 28 111 102 93 85 78 72 67 62 58 54 51 111 98 86 76 68 61 55 50 46 43 40 111 95 80 69 60 53 47 43 39 35 32 111 91 75 63 54 47 42 37 33 30 28 20% 50% 50 30 10 30% 50 30 10 50 105 93 82 73 65 59 53 49 45 41 38 100 89 78 69 62 56 51 47 43 40 37 95 84 75 66 60 54 49 45 42 39 36 105 90 77 67 58 52 46 42 38 35 32 105 88 73 62 53 46 41 37 33 30 27 100 86 74 64 57 50 45 41 37 34 31 Zonal Lumen Summary Luminance Data Zone 0-30 0-40 0-60 0-90 0-180 Angle in Deg 45 55 65 75 85 Lumens 7543 11643 19248 23832 24988 %Lamp 29.3 45.3 74.9 92.7 97.2 %Fixture 30.2 46.6 77.0 95.4 100.0 Average 0-Deg cd/sm 22550 21302 18922 13994 4470 100 84 71 60 52 45 40 36 32 29 27 10% 30 10 95 83 71 62 55 49 44 40 36 33 31 95 81 68 59 51 45 40 35 32 29 27 Average 45-Deg cd/sm 15190 14171 12993 13191 7307 0% 0 93 79 66 56 49 42 38 33 30 27 25 Average 90-Deg cd/sm 14723 13778 14442 12599 2335 Modular F-Bay Power Supply Option Cooper Lighting’s F-Bay Modular Power Supply option is available for use with all F-Bay products. The modular power supply allows external fixture access for safe and easy servicing. There is no need to remove lamps or reflectors to disconnect fixture power with F-Bay Modular Power Supply. Access to the individual fixture’s power supply allows servicing without turning off all the fixtures, disrupting occupants. F-Bay Modular Power Supply is a time-saver in installation – simply plug & power. Code Compliance • UL/cUL Certified for Make/Break under load (UL2549) • Meets NEC requirements for ballast disconnect (NEC 410.73G) 1 • Allows for addition of Occupancy Sensor without hard connections 2 1. Modular Power Supply Receptacle supplied mounted into fixture Access Plate 2. Modular Power Cord & Plugs in 120, 277, 347, & 480V configurations for easy plug & power into existing supply No internal fixture access required for installation or disconnecting power Modular Motion Sensor Option supplied with Mounting Box and Modular Power Supply Receptacle • Receptacles complete with insulating/dust cap Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 ADF110940 pc 2012-01-30 14:08:00 HBI T5 O R D E R I N G I N F O R M AT I O N SAMPLE NUMBER: HBI-647T5-N-UNV-EHT2-MP-UPL-U Voltage 2 UNV=Universal 120/277V 120V=120 Volt 277V=277 Volt Series HBI=High Bay Industrial No. of Lamps 4=4 Lamps 5=5 Lamps 6=6 Lamps Options Lamps Installed 5 L5841=T5 Lamp, 85CRI 4100K L5850=T5 Lamp, 85CRI 5000K GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed 2 Lamp Type 47T5= 47W T5HO Lamps (48") Distribution N=Narrow Beam (Standard) M=Medium Beam W=Wide Beam Shielding Blank=None A=Prismatic Acrylic Lens & Doorframe WG=Wireguard & Doorframe A/WG=Acrylic Lens, Wireguard & Doorframe CL=Clear Acrylic Lens & Doorframe CL/WG=Clear Lens, Wireguard & Doorframe Accessories (order separately) HB-SPM=Single Monopoint Hanger w/Hub RH-1=Retrofit Hanger FH-1=Fixture Hook FL-1=Fixture Loop Y-TOGGLE- =Y Mounting Toggle, #2 Cable 6 (Specify 10' or 30', requires 2 per fixture) HBAYC-CHAIN/SET/U=(2) V-Hook Hangers, 36" Chain Sets w/S-Hooks MC3=3' Modular Power Cord Options MPC3=3' Modular Power Cord & Plug MP =Modular Power Receptacle (Specify Voltage) (Used for all Cord or Cord and MC6=6' Modular Power Cord Plug options) 1 7 MPC6=6' Modular Power Cord & Plug NUA=No uplight apertures in housing. (Specify Voltage) UPL=Uplight Apertures on Reflector MMS=360° or 180° Aisle Motion Sensor with MWS=Modular Wiring System Modular Power Receptacle (120-277V) 1 MDS6=6' Modular Power Cord with MWS MS=360° or 180° Motion Sensor, 27DS18/2G06MP Connector 8 120 through 277 3 SWG=Heavy Duty Wireguard for Field G2=Gasketed Door (Requires Installation Selection of Lensed Doorframe) Ballast Type EHT =T5HO Linear Electronic Rapid Program Start High Ambient. 4 Total Harmonic Distortion < 10% No. of Ballast 2 or 3 SDF=Slotted Doorframe (Requires Selection of Lensed Doorframe) Packaging U=Unit Pack PALC=Palletized In Carton PAL=Job Pack Out of Carton NOTES: 1 Requires use of MC or MPC cord accessories, specify voltage for plugs. 2 Voltage must be specified when ordered with plugs or emergency ballasts. 3 When ordering MS option, specify voltage as UNV (for 120 or 277V. 4 EHT/HT5/HCT5 ballast systems suitable for ambient environments not to exceed 149°F. (65°C) in open uplight configurations and less lens option. 5 Must specify lamps when ordering. 6 Two required. 7 Not compatible with UPL option. 8 For MWS with MP, choose MP in the fixture logic and then choose MWS accessory such as MDS6. S H I P P I N G DATA Catalog No. HBI-647T5-N-UPL Specifications and dimensions subject to change without notice. Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 468.4801 Wt. 16 lbs. ADF110940 pc 2012-01-30 14:08:00