SURE-LITES ®

advertisement
SURE-LITES
D es c r iption
The Sure-Lites INV125CI is a UL Listed stand-alone modified sine wave
output inverter designed to provide power to designated emergency
lighting fixtures. In a power loss situation, the unit will supply 125W of
power from the onboard battery supply. It works in conjunction with
incandescent, LED, and fluorescent lamps and fixture types and will
automatically run switched, normally-on, or normally-off designated
emergency fixtures. The INV125CI is ideal for applications requiring an
emergency source for lighting arrangements that utilize multiple lamp
and fixture types. It is designed for installation in the ceiling grid and
comes with a three-year warranty and seven-year pro-rata warranty. The
INV125CI is not for use in air supply/air return ceilings.
Catalog #
®
Type
Project
Comments
Date
Prepared by
Spe c ific a tion F ea t u r e s
E le c t r i c a l
Hous i ng Cons t ru ction
Co d e Co mplian ce
- Dual voltage 120/277 60Hz
- Emergency lighting supplied from
one convenient source
- Operates incandescent, LED and
fluorescent fixtures including
fixtures with dimmable
fluorescent ballasts
- Includes momentary contact test
switch, yellow ready indicator,
green inverter-on indicator, and
red charging indicator
- Durable 18-gauge steel housing
design with white semi-gloss
powder-coat paint finish
- Grid ceiling mounting design
- Replaceable output fuse
protection
- Variable-rate, temperaturecompensated charger
- Includes momentary contact test
switch, yellow ready indicator,
green inverter-on indicator, and
red charging indicator
- UL 924 Listed
- Meets or exceeds all National
Electrical Code and Life Safety
Code Emergency Lighting
Requirements
Ap p lication
- LED, Fluorescent and
Incandescent Lighting
Warran ty
-3/7 Pro-Rata Warranty
INV125CI
Emergency
Inverter
Series
LED
Fluorescent
Incandescent
On-line P ow er I nv er ter
S y s tem s
spec ific a tions
Input Voltage:........................................................................................ (Dual) 120/277V, 60Hz
Input Rating (bulk):............................................................................... 150 Watts
Output Voltage:..................................................................................... (Dual) 120/277V, 60Hz
Output Power:....................................................................................... 125 Watts (@ .9 leading to .9 lagging PF)
Lamps Operated:.................................................................................. LED, Fluorescent, Incandescent
Transfer Time:....................................................................................... less than 50 milliseconds
Emergency Operation:......................................................................... 90 minutes
Voltage Regulation (emergency):........................................................ +/- 10%
Frequency Regulation (emergency):................................................... +/- 3%
Load Power Factor Range:................................................................... .9 leading to .9 lagging
Operating Temp:................................................................................... 20° to 30° C
Battery:.................................................................................................. Valve Regulated Lead Acid (VRLA)
Weight:.................................................................................................. 42.5 lbs.
ADX142596
2014-11-14 10:16:18
INV125CI Emergency Inverter Series
Wir ing D ia gr a m
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Eaton’s Cooper Lighting Business
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
Specifications and
dimensions subject to
change without notice.
Download