SURE-LITES D es c r iption The Sure-Lites INV125CI is a UL Listed stand-alone modified sine wave output inverter designed to provide power to designated emergency lighting fixtures. In a power loss situation, the unit will supply 125W of power from the onboard battery supply. It works in conjunction with incandescent, LED, and fluorescent lamps and fixture types and will automatically run switched, normally-on, or normally-off designated emergency fixtures. The INV125CI is ideal for applications requiring an emergency source for lighting arrangements that utilize multiple lamp and fixture types. It is designed for installation in the ceiling grid and comes with a three-year warranty and seven-year pro-rata warranty. The INV125CI is not for use in air supply/air return ceilings. Catalog # ® Type Project Comments Date Prepared by Spe c ific a tion F ea t u r e s E le c t r i c a l Hous i ng Cons t ru ction Co d e Co mplian ce - Dual voltage 120/277 60Hz - Emergency lighting supplied from one convenient source - Operates incandescent, LED and fluorescent fixtures including fixtures with dimmable fluorescent ballasts - Includes momentary contact test switch, yellow ready indicator, green inverter-on indicator, and red charging indicator - Durable 18-gauge steel housing design with white semi-gloss powder-coat paint finish - Grid ceiling mounting design - Replaceable output fuse protection - Variable-rate, temperaturecompensated charger - Includes momentary contact test switch, yellow ready indicator, green inverter-on indicator, and red charging indicator - UL 924 Listed - Meets or exceeds all National Electrical Code and Life Safety Code Emergency Lighting Requirements Ap p lication - LED, Fluorescent and Incandescent Lighting Warran ty -3/7 Pro-Rata Warranty INV125CI Emergency Inverter Series LED Fluorescent Incandescent On-line P ow er I nv er ter S y s tem s spec ific a tions Input Voltage:........................................................................................ (Dual) 120/277V, 60Hz Input Rating (bulk):............................................................................... 150 Watts Output Voltage:..................................................................................... (Dual) 120/277V, 60Hz Output Power:....................................................................................... 125 Watts (@ .9 leading to .9 lagging PF) Lamps Operated:.................................................................................. LED, Fluorescent, Incandescent Transfer Time:....................................................................................... less than 50 milliseconds Emergency Operation:......................................................................... 90 minutes Voltage Regulation (emergency):........................................................ +/- 10% Frequency Regulation (emergency):................................................... +/- 3% Load Power Factor Range:................................................................... .9 leading to .9 lagging Operating Temp:................................................................................... 20° to 30° C Battery:.................................................................................................. Valve Regulated Lead Acid (VRLA) Weight:.................................................................................................. 42.5 lbs. ADX142596 2014-11-14 10:16:18 INV125CI Emergency Inverter Series Wir ing D ia gr a m Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton’s Cooper Lighting Business 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com Specifications and dimensions subject to change without notice.