Automation Interface Module (AIM) Worksheet ü Communications Interface Module (CIM) Worksheet Directions: Fill in section 1: Document the desired status and control points for each lighting panel. Please indicate the # of relays in each panel and whether you would like to just check status or if you would also like to issue commands. If the panels have the same command and status requirements, you may submit one sheet that has all applicable panels listed in the space provided at the bottom of this section. Fill in section 2 on one sheet only. Section I Relay Check Relay Status ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Issue Relay Commands ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü Relay Outputs If you wish to issue commands to this relay as part of a command group, please indicate group # that this relay belongs to. Local Contact Inputs Notes Input Check Input Status Notes 32 ü ü ü ü Analog Input Check Input On/Off Status Check Analog Reading 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 01 02 03 04 Occ Sensor Photocell Occ Sensor Lighting Control Relay Panel Information Panel Type (1 type per sheet) CKT Panel Address LCP1 LCP2 LCP3 LCP4 LCP5 Panel Location Electrical Rm W Electrical Rm E Electrical Rm 1A Electrical Rm N Electrical Rm S Panel Address Panel Location LCP6 Electrical Rm 2C Panel Address Panel Location Panel Address Panel Location Page Page 5 Section II Setup Information (Fill in on one sheet only and choose only one protocol) ü Automation Interface Module (AIM) Communications Interface Module (CIM) What Protocol will you be using? (circle one) BACnet BACnet BACnet willbe beusing usingBACnet BACnetover overIP IP üI Iwill Default DefaultGateway GatewayIPIPAddress Address BACnet DesiredNetwork BACnetNumber Device Object Instance ID# Desired BACnet Device Object Instance ID# LON (Please (Pleaseprovide providethe thefollowing followinginformation informationfor forproper proper configuration. configuration. Please Pleasenote note––the theMAC MACaddress address information informationofofthe theunit unitwill willbe beprovided providedon onthe thefinal final mapping mappingtable tableonce oncethe theunit unitisisconfigured) configured) 10.429.92.7 255.255.255.1 Subnet SubnetMask Mask Modbus I Iwill willbe beusing usingBACnet BACnetover overEthernet Ethernet (Please (Pleaseprovide providethe thefollowing followinginformation informationfor forproper proper configuration) configuration) IPIPAddress Address COMPLETE ONLY ONE SECTION BELOW BACnet BACnetNetwork NetworkNumber Number 10.429.92.6 60001 6 Desired DesiredBACnet BACnetDevice DeviceObject ObjectInstance InstanceID# ID# I will be using BACnet over ARC156 following information for proper I (Please will be provide using the BACnet over ARC156 I will be using BACnet over MS/TP following information I(Please will beprovide usingthe BACnet over MS/TPfor proper configuration) (Please provide the following information for proper configuration) Desired ARCnet Address configuration) (Please provide the following information for proper configuration) Desired MS/TP Address Desired BACnetARCnet NetworkAddress Number Desired Address BACnetMS/TP Network Number BACnet DesiredNetwork BACnet Number Device Object Instance ID# BACnet DesiredNetwork BACnet Number Device Object Instance ID# Desired BACnet Device Object Instance ID# Desired Device What isBACnet the desired baudObject rate Instance ID# What Whatisisthe thedesired desiredbaud Max rate Master setting? (default is 127) What is the desired Max Master setting? (default is 127) Modbus Choose Protocol Configuration: Baud Rate Data Bits Expected Choose Protocol Configuration RTU ACCII Baud Rate 1200 2400 4800 Choose Com Type RS232 2wire RS485 4 wire RE485/422 9600 19200 38400 Parity Indicate Desired Slave Address Odd Even None N2 What N2 slave address should be assigned to the AIM? (This address must be different from any other N2 device on the N2 BUS.) LON No additional Information needed Data Bits Expected 8 7 Stop Bits Expected 1 2 N2