Series 601 Optically Isolated AC Solid-State Relay 5 and 10A/250 Vac

advertisement
Series 601
Optically Isolated 5 and 10A/250 Vac
AC Solid-State Relay
Part Number
Description
601-1*
5A, 280Vac solid-state relay
601-2*
10A, 280Vac solid-state relay
*Add H suffix for higher over voltage
See Note 3
MECHANICAL SPECIFICATION
1.00
(25.4)
.80
(15.24)
3
FEATURES
• Optical Isolation: Isolates control elements from
load transients
• Floating Output: Eliminates ground loops and
signal-level ground noise.
• Zero Voltage Turn-On: Reduces switching
transient noise
• Low Off-State Leakage Current: High off-state
impedance.
• High Dielectric Strength: For safety and
protection of signal-level circuits.
.970 MAX
(24.54)
.375
(9.52)
MIN
4
2.00
1.50 (50.8)
(38.1) ±.02
1
2
.032 (.81) DIA
PIN (4 PL)
DESCRIPTION
This series of AC SSRs has been designed to
incorporate custom integrated circuits to replace
conventional discrete circuitry. The result is a relay
with low component count, high performance,
reliability, and low cost. Optical coupling between
control and load provides a minimum of 1500
Vrms input/output isolation. The output circuitry
includes built-in snubber protection to guarantee
high immunity from false triggering and reliable
switching of low power factor loads.These relays
are available in three terminal styles for optimum
mounting flexibility. Pin terminals mount directly
on a printed circuit board, screw terminals or quick
disconnect terminals are for chassis or heat sink
mounting.
PC BOARD VERSION (5A)
601-1, -1H
1.00
(25.4)
.60
(15.24)
2
.90
(22.8)
MAX
.04 ±.02
1
2.00
1.50 (50.8)
(38.1)
4
.750
(19.05)
3
TO ACCEPT
#6–32 TERMINAL
SCREWS (4 PL)
.110 (2.794) DIA
THRU MTG. HOLE
ANTIROTATION
TO ACCEPT
BOSS ON VERTICAL
#6 SCREW
CENTER LINE
SCREW TERMINAL VERSION (10A)
601-2, -2H
WEIGHT: 3.0 oz. (85g)
UNLESS OTHERWISE SPECIFIED, TOLERANCES ARE:
X.XX ±.01 INCHES
X.XXX ±.005 INCHES
INPUT (CONTROL) SPECIFICATIONS
Figure 1 – 601-1 and 601-2 relays;
dimensions in inches (mm)
Control Voltage Range
Min
Max
Units
3.0
32.0
Vdc
14
mA
Input Current
WIRING DIAGRAM
Must Turn-On Voltage
*MOV
Vdc
1.0
Vdc
Reverse Voltage
–32
Vdc
LOAD
1+
3.0
Must Turn-Off Voltage
1
3
2
4
DC CONTROL
SOURCE
1–
*Optional MOV
AC LINE
Figure 2
601 16
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2002 TELEDYNE RELAYS
601\072002\Q1
Series 601
OUTPUT (LOAD) SPECIFICATIONS
Load Voltage Rating
CHARACTERISTICS CURVES
Max
Units
250
Vrms
12
CONTROL CURRENT (mA)
Min
Output Current Rating
601-1
0.1
5.0
Arms
601-2
0.1
10.0
Arms
47
70.0
Hz
Frequency Range
Over Voltage Range
601-1, -2
500
Vpeak
601-1H, -2H
600
Vpeak
On-State Voltage Drop
4.0
Vrms
1000
%
10
8
6
4
2
0
0
5
10
15
20
25
30
35
CONTROL VOLTAGE (Vdc)
Figure 3 – Typical input current vs. control voltage
(@ Rated Current)
(See Figure 6 and Note 4)
Turn-On Time
0.5
Cycle
Turn-Off Time
1.0
Cycle
Off-State Leakage @ 250 Vrms
9.0
mArms
Off-State dv/dt (See Note 1) 200
Capacitance (Input to Output)
V/µs
15.0
6
5
LOAD CURRENT (A)
Surge Current Rating (16 ms)
NO
4
HE
AT
SIN
K
3
2
1
pF
0
0
10
20
ENVIRONMENTAL SPECIFICATIONS
Max
Units
Operating Temperature
–40
+80
°C
Storage Temperature
–40
+80
°C
125
°C
Dielectric Strength
Isolation
40
50
60
70
80
90
1500
Vac
109
Ohms
Thermal Resistance
(θJA) 601-1
19.0
°C/W
(θJS) 601-2
4.8
°C/W
Figure 4 – Maximum load current vs.
ambient temperature 601-1
12
MOUNTED ON 1.0˚C/W HEAT SINK (SEE NOTE 5)
LOAD CURRENT (A)
Min
Junction Temperature (TJ)
30
AMBIENT TEMPERATURE (˚C)
10
8
6
NO HE
AT SIN
K
4
2
0
0
10
20
30
40
50
60
70
80
90
AMBIENT TEMPERATURE (˚C)
Figure 5 – Maximum load current vs.
ambient temperature 601-2
© 2002 TELEDYNE RELAYS
1000
PEAK SURGE CURRENT
(% RATED CURRENT)
NOTES
1. Output transient (dv/dt) protection is provided in all models
and they are designed to switch resistive or inductive loads
to 0.2 power factor. The dv/dt rating is based on a source
impedance of 50 ohms.
2. For any mounting conditions: 5-amp relays, θJA = 19°C/W.
For 10-amp relays, θJS = 4.8°C/W.
3. Basic part number provides screw terminals or PC board
pins (Figure 1). For single 1/4-inch quick disconnect
terminals, add suffix ‘Q” to 10-amp part numbers, or “QQ”
suffix for double 1/4-inch quick disconnects. (Examples:
601-2Q, 601-2QQ).
4. Triac may lose blocking capability during and after surge
until T(J) falls below maximum.
5. Relays mounted with silicone grease on heat sink such as
Astrodyne, Inc., Type 2518-0500-A00B (for 1.0°C/W).
800
600
400
200
10
100
1000
10000
SURGE DURATION (ms) - NON-REPETITIVE
Figure 6 – Maximum surge as function of load voltage
(800) 284-7007 • www.teledynerelays.com
601 17
601\072002\Q1