Series 1 - Steven Engineering

advertisement
Series 1
10-90Amp • 120/240 Vac - AC OUTPUT
Featuring state-of-the-art Surface
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications. Output
consists of an SCR AC switch and is
available in zero-cross, random turnon (phase controllable) and normally
closed (Form B) versions with either
AC or DC input (coil) control.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
• Zero Voltage and Random
Turn-On Switching
• Panel Mount
• 600V Transient Capability
• Internal Snubber
• 110 & 125A Models
Available
• Integrated Overvoltage
Protection by Automatic
Self Turn-On (Suffix P)
A1210
D1210
A1225
D1225
A1240
D1240
A2410
D2410
A2425
D2425
A2450
D2450
A2475
D2475
A2490
D2490
24-140
24-140
24-140
24-280
24-280
24-280
24-280
24-280
10
25
40
10
25
50
75
90
Min. Load Current, [mArms]
40
40
40
40
40
40
40
40
Transient Overvoltage [Vpk]
400
400
400
600
600
600
600
600
Max. Surge Current, (16.6ms) [Apk]
120
250
625
120
250
625
1000
1200
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
Thermal Resistance Junction to Case (R θJC) [˚C/W]
1.48
1.02
0.63
1.48
1.02
0.63
0.31
0.28
60
260
1620
60
260
1620
4150
6000
8
8
8
10
10
10
10
10
500
500
500
500
500
500
500
500
0.5
0.5
MODEL NUMBERS
AC CONTROL
D C CONTROL
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current
➂ [Arms]
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Max. Turn-On Time
➁
➃
1/2 Cycle (DC Control), 10.0 msec (AC Control)
1/2 Cycle (DC Control), 40.0 msec(AC Control)
Max. Turn-Off Time
0.5
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
DC CONTROL
0.5
0.5
0.5
0.5
AC CONTROL
0.5
AC CONTROL
(E SUFFIX)
Control Voltage Range
3-32 Vdc
90-280 Vrms (60Hz)
18-36 Vrms
Max. Reverse Voltage
-32 Vdc
---
---
Max. Turn-On Voltage
3.0 Vdc
90 Vrms
18 Vrms
Min. Turn-Off Voltage
1.0 Vdc
10 Vrms
4.0 Vrms
1500 Ohms
60K Ohms
9.0K Ohms
3.4mA @ 5 Vdc, 20mA @ 28Vdc
2mA @ 120 Vrms, 4mA @ 240 Vrms
3mA @ 24 Vrms
Nominal Input Impedance
Typical Input Current
© 2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25˚ C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 3.
➃ Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).
FastFax Document No. 151
SERIES1
Rev. 102104
PAGE 1 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Series 1
10-90Amp • 120/240 Vac - AC OUTPUT
GENERAL SPECIFICATIONS
4000 Vrms
Dielectric Strength 50/60Hz Input/Output/Base
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
8 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Terminals:
Thermally Conductive Epoxy
Screws and Saddle Clamps Furnished, Unmounted
AVAILABLE OPTIONS
-B
Normally Closed (Form B)
Example: D2450-B, A2450-B
E
24 Vac Input (18-36 Vac)
Example: A2450E
F
Faston Terminals (Up to 50A Models)
Example: D1225F
G
Input Status LED.
Agencies Approval Pending
Example: D2450G
Note: Control Voltage Range 4.5-32Vdc
for DC Control Models.
P
4D
-10
Random Turn-On (AC & DC Control)
Phase Controllable (DC Control)
Example: D2450-10
Heat Transfer Pad (Attached)
Example: D2450H
Ordering System: Combination of the
suffixes should be made in the following order:
EFPG-10.
Example: A2450EFPG-10
OUTPUT
1
8-32 TERMINAL
(2 PLACES )
2
1.87
(47.5)
-4
6-32 TERMINAL
(2 PLACES)
1.10
(27.9)
.45
(11.4)
OUTPUT
1
Fastons:
Single pair (up to 25A)
Double pair* (up to 50A).
*Caution: User must connect to both pairs
--
4
2
+
INPUT
1.00
(25.4)
1.80
(45.7)
.78
(19.8)
.90
(22.9)
FASTON TERMINAL
.250 X .032 (2 PLCS.)
.87 REF.
(22.2)
1.87
(47.5)
BASE PLATE
.125 (3.2)
2.30
(58.4)
1.70
(43.2)
3
1.00
(25.4)
1.80
(45.7)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
Screw Torque Requirements:
6-32 Screws - 10 in. lbs.,
8-32 and 10-32 Screws - 20in. lbs.
(Screws dry without grease.)
+
INPUT
BASE PLATE
.125 (3.2)
Internal Overvoltage Protection.
Relay Will Self Trigger Between
450-600 Vpk. Not Suitable For Capacitive Loads.
Not Available with -B Option
Agencies Approval Pending.
Example: D2425P
400 Hz Operation
10-50 Amp Models Only
Zero Cross Switching Only
Example: 4D2450
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
2.30
(58.4)
1.70
(43.2)
3
FASTON
TERMINAL
.187 X .032
(2 PLCS.)
.78
(19.8)
.90
(22.9)
H
APPROVALS
UL
E116949
CSA LR81689
VDE 10143 UG (Not Applicable: -B and 4D)
FastFax Document No.151
SERIES1
Rev. 102104
PAGE 2 OF 3
Crydom Heat Sinks offer excellent
thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays.
Request Crydom’s Heat Sink specifica
tion sheet for all the details.
All dimensions are in inches (millimeters)
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Series 1
10-90Amp • 120/240 Vac - AC OUTPUT
CURRENT DERATING CURVES
10A
25A
12
30
110
5˚C/W
8
NO HEATSINK
115
4
120
25
100
3˚C/W
2˚C/W
20
15
110
10
NO HEATSINK
5
4
6
8
10
Load Current [Arms]
50A
40
60
5
80
.5˚C/W
80
20
40
60
80
60
80
90
1˚C/W
110
40
.2˚C/W
.4˚C/W
Power Dissipation
100
Base Plate Temp [˚C]
.3˚C/W
.5˚C/W
80
100
1˚C/W
110
40
120
120
0
Max Ambient Temp. [˚C]
40
90A
120
NO HEATSINK
0
50
20
Max Ambient Temp. [˚C]
120
95
Power Dissipation
110
20
40
25
.5˚C/W
Base Plate Temp [˚C]
100
2˚C/W
30
20
90
40
20
15
75A
1.5˚C/W
Load Current [Arms]
10
Load Current [Arms]
120
1˚C/W
Power Dissipation
20
Max Ambient Temp. [˚C]
0
15
30
45
60
Load Current [Arms]
75
20
40
60
80
Max Ambient Temp. [˚C]
20
40
60
80
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No.151
SERIES1
Rev. 102104
PAGE 3 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Base Plate Temp [˚C]
2
10
120
0
0
60
Base Plate Temp [˚C]
1˚C/W
Power Dissipation
Power Dissipation
9˚C/W
95
3˚C/W
Base Plate Temp [˚C]
7˚C/W
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series A48, D48
12-90Amp • 480 Vac - AC OUTPUT
• Zero Voltage and Random
Turn-On Switching
• Panel Mount
• 800V Transient Capability
• Internal Snubber
MODEL NUMBERS
AC CONTROL
D C CONTROL
A4812
D4812
A4825
D4825
Featuring state-of-the-art Surface
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications.
Output consists of an SCR AC switch
and is available in zero-cross, random
turn-on (phase controllable) and versions with either AC or DC input (coil)
control.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
A4850
D4850
A4875
D4875
A4890
D4890
OUTPUT SPECIFICATIONS ➀
80-530
80-530
80-530
80-530
80-530
12
25
50
75
90
Min. Load Current, [mArms]
40
40
40
40
40
Transient Overvoltage [Vpk]
800
800
800
800
800
Max. Surge Current, (16.6ms) [Apk]
140
250
625
1000
1200
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.7
1.7
1.7
1.7
1.7
Thermal Resistance Junction to Case (R θJC) [˚C/W]
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current
➂
[Arms]
1.48
1.02
0.63
0.31
0.28
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
81
260
1620
4150
6000
Max. Off-State Leakage Current @ Rated Voltage [mArms]
10
10
10
10
10
500
500
500
500
500
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁
Max. Turn-On Time ➃
1/2 Cycle (DC Input), 10.0 msec (AC Input)
Max. Turn-Off Time
1/2 Cycle (DC Input), 40.0 msec (AC Input)
0.5
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
DC CONTROL
(D PREFIX)
0.5
0.5
0.5
AC CONTROL
(A PREFIX)
Control Voltage Range
3-32 Vdc
90-280 Vrms (60Hz)
Max. Reverse Voltage
-32 Vdc
---
Max. Turn-On Voltage
3.0 Vdc
90 Vrms
Min. Turn-Off Voltage
1.0 Vdc
10 Vrms
See Note ➄
60K Ohms
2.0 mA ➄
2mA @ 120 Vrms, 4mA @ 240 Vrms
Nominal Input Impedance
Typical Input Current
© 2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀
➁
➂
➃
➄
All parameters at 25˚C unless otherwise specified.
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
Heat sinking required, for derating curves see page 2.
Turn-on time for random turn-on versions
is 0.02 msec (DC Control Models).
Input circuitry incorporates active current limiter.
FastFax Document No.
SERIES A48/D48.
Rev. 111003
PAGE 1 OF 3
0.5
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series A48, D48
12-90Amp • 480 Vac - AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
8 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
MECHANICAL SPECIFICATIONS
Weight: (typical)
Encapsulation:
Thermally Conductive Epoxy
Screws and Saddle Clamps Furnished, Unmounted
Terminals:
AVAILABLE OPTIONS
-10
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
Random Turn-On (AC & DC Control)
Phase Controllable (DC Control)
Example: D4890-10
OUTPUT
1
F
Faston Terminals (Up to 25 Amp Models)
Example: D4850F
H
--
2
+
4
Heat Transfer Pad (Attached)
Example: D4850H
INPUT
6-32 TERMINAL
(2 PLACES)
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1
OUTPUT
-4
2
+
INPUT
1.00
(25.4)
1.80
(45.7)
.78
(19.8)
.90
(22.9)
FASTON TERMINAL
.250 X .032 (2 PLCS.)
.87 REF.
(22.2)
1.87
(47.5)
BASE PLATE
.125 (3.2)
2.30
(58.4)
1.70
(43.2)
3
1.00
(25.4)
1.80
(45.7)
BASE PLATE
.125 (3.2)
Fastons:
Single pair (up to 25A)
Double pair* (up to 50A).
*Caution: User must connect to both pairs
Crydom Heat Sinks offer excellent
thermal management and are perfectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom’s Heat Sink
specification sheet for all the details.
8-32 TERMINAL
(2 PLACES )
1.87
(47.5)
Screw Torque Requirements:
6-32 Screws - 10 in. lbs.,
8-32 and 10-32 Screws - 20in. lbs.
(Screws dry without grease.)
3.0 oz. (86.5g)
2.30
(58.4)
1.70
(43.2)
3
FASTON
TERMINAL
.187 X .032
(2 PLCS.)
.78
(19.8)
.90
(22.9)
All dimensions are in inches (millimeters)
APPROVALS
UL E116949
CSA LR81689
VDE 10143 UG
FastFax Document No.
SERIES A48/D48
Rev. 111003
PAGE 2 OF 3
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series A48, D48
12-90Amp • 480 Vac - AC OUTPUT
CURRENT DERATING CURVES
12A
14
25A
12
30
110
5˚C/W
8
NO HEATSINK
6
115
4
120
25
4
6
8
10
12
.5˚C/W
40
60
5
80
20
80
60
80
Max Ambient Temp. [˚C]
40
60
80
90
1˚C/W
110
40
.2˚C/W
.4˚C/W
Power Dissipation
100
Base Plate Temp [˚C]
.3˚C/W
.5˚C/W
80
100
1ºC/W
110
40
120
120
0
40
20
Max Ambient Temp. [˚C]
90A
120
NO HEATSINK
0
20
25
120
95
Power Dissipation
110
20
50
15
.5˚C/W
Base Plate Temp [˚C]
100
2˚C/W
40
10
Load Current [Arms]
90
40
30
120
75A
1.5˚C/W
Power Dissipation
20
Max Ambient Temp. [˚C]
120
20
110
10
0
15
30
45
60
Load Current [Arms]
75
20
40
60
80
Max Ambient Temp. [˚C]
20
40
60
80
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No.
SERIES A48/D48.
Rev. 111003
PAGE 3 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Base Plate Temp [˚C]
2
50A
Load Current [Arms]
15
0
0
60
10
20
5
Load Current [Arms]
1˚C/W
2˚C/W
NO HEATSINK
2
0
100
3˚C/W
Base Plate Temp [˚C]
9˚C/W
1˚C/W
Power Dissipation
Power Dissipation
10
95
3˚C/W
Base Plate Temp [˚C]
7˚C/W
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series A48, D48
12-90Amp • 480 Vac - AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
8 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
MECHANICAL SPECIFICATIONS
Weight: (typical)
Encapsulation:
Thermally Conductive Epoxy
Screws and Saddle Clamps Furnished, Unmounted
Terminals:
AVAILABLE OPTIONS
-10
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
Random Turn-On (AC & DC Control)
Phase Controllable (DC Control)
Example: D4890-10
Faston Terminals (Up to 25 Amp Models)
Example: D4850F
H
1.87
(47.5)
INPUT
6-32 TERMINAL
(2 PLACES)
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1
OUTPUT
1.87
(47.5)
4
2
+
INPUT
1.00
(25.4)
1.80
(45.7)
.78
(19.8)
.90
(22.9)
FASTON TERMINAL
.250 X .032 (2 PLCS.)
.87 REF.
(22.2)
SOLID-STATE RELAY
--
BASE PLATE
.125 (3.2)
2.30
(58.4)
1.70
(43.2)
3
1.00
(25.4)
1.80
(45.7)
BASE PLATE
.125 (3.2)
Fastons:
Single pair (up to 25A)
Double pair* (up to 50A).
*Caution: User must connect to both pairs
Crydom Heat Sinks offer excellent
thermal management and are perfectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom’s Heat Sink
specification sheet for all the details.
+
4
Screw Torque Requirements:
6-32 Screws - 10 in. lbs.,
8-32 and 10-32 Screws - 20in. lbs.
(Screws dry without grease.)
2
SOLID-STATE RELAY
--
Heat Transfer Pad (Attached)
Example: D4850H
8-32 TERMINAL
(2 PLACES )
OUTPUT
1
F
3.0 oz. (86.5g)
2.30
(58.4)
1.70
(43.2)
3
FASTON
TERMINAL
.187 X .032
(2 PLCS.)
.78
(19.8)
.90
(22.9)
All dimensions are in inches (millimeters)
APPROVALS
UL E116949
CSA LR81689
VDE 10143 UG
FastFax Document No.
SERIES A48/D48
Rev. 111003
PAGE 2 OF 3
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series A48, D48
12-90Amp • 480 Vac - AC OUTPUT
CURRENT DERATING CURVES
12A
14
25A
12
30
110
5˚C/W
8
NO HEATSINK
6
115
4
120
25
4
6
8
10
12
.5˚C/W
40
60
5
80
20
80
60
80
Max Ambient Temp. [˚C]
40
60
80
90
1˚C/W
110
40
.2˚C/W
.4˚C/W
Power Dissipation
100
Base Plate Temp [˚C]
.3˚C/W
.5˚C/W
80
100
1ºC/W
110
40
120
120
0
40
20
Max Ambient Temp. [˚C]
90A
120
NO HEATSINK
0
20
25
120
95
Power Dissipation
110
20
50
15
.5˚C/W
Base Plate Temp [˚C]
100
2˚C/W
40
10
Load Current [Arms]
90
40
30
120
75A
1.5˚C/W
Power Dissipation
20
Max Ambient Temp. [˚C]
120
20
110
10
0
15
30
45
60
Load Current [Arms]
75
20
40
60
80
Max Ambient Temp. [˚C]
20
40
60
80
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No.
SERIES A48/D48.
Rev. 111003
PAGE 3 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Base Plate Temp [˚C]
2
50A
Load Current [Arms]
15
0
0
60
10
20
5
Load Current [Arms]
1˚C/W
2˚C/W
NO HEATSINK
2
0
100
3˚C/W
Base Plate Temp [˚C]
9˚C/W
1˚C/W
Power Dissipation
Power Dissipation
10
95
3˚C/W
Base Plate Temp [˚C]
7˚C/W
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series HA, HD
12-90Amp • 480 Vac - AC OUTPUT
Featuring state-of-the-art Surface
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications.
Output consists of an SCR AC switch
and is available in zero-cross, random
turn-on (phase controllable) and versions with either AC or DC input (coil)
control.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
• Zero Voltage and Random
Turn-On Switching
• Panel Mount
• 1200V Transient Capability
• Integrated Overvoltage
Protection by Automatic
Self Turn-On (Suffix P)
• 110 & 125A Models
Available
HA4812
HD4812
HA4825
HD4825
HA4850
HD4850
HA4875
HD4875
HA4890
HD4890
48-530
48-530
48-530
48-530
48-530
12
25
50
75
90
Min. Load Current, [mArms]
40
40
40
40
40
Transient Overvoltage [Vpk]
1200
1200
1200
1200
1200
Max. Surge Current, (16.6ms) [Apk]
140
250
625
1000
1200
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.7
1.7
1.7
1.7
1.7
Thermal Resistance Junction to Case (R θJC) [˚C/W]
MODEL NUMBERS
AC CONTROL
D C CONTROL
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current
➂
[Arms]
1.48
1.02
0.63
0.31
0.28
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
81
260
1620
4150
6000
Max. Off-State Leakage Current @ Rated Voltage [mArms]
10
10
10
10
10
500
500
500
500
500
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Max. Turn-On Time
➁
➄
1/2 Cycle (DC Input), 10.0 msec (AC Input)
1/2 Cycle (DC Input), 40.0 msec (AC Input)
Max. Turn-Off Time
0.5
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
DC CONTROL
(D PREFIX)
0.5
0.5
0.5
0.5
AC CONTROL
( A P R E F I X )➃
AC CONTROL
(E SUFFIX)
Control Voltage Range
3-32 Vdc
90-280 Vrms (60Hz)
18-36 Vrms
Max. Reverse Voltage
-32 Vdc
---
---
Max. Turn-On Voltage
3.0 Vdc
90 Vrms
18 Vrms
Min. Turn-Off Voltage
1.0 Vdc
10 Vrms
4.0 Vrms
See Note ➅
60K Ohms
9.0K Ohms
2.0 mA ➅
2mA @ 120 Vrms, 4mA @ 240 Vrms
3mA @ 24 Vrms
Nominal Input Impedance
Typical Input Current
© 2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀
➁
➂
➃
➄
All parameters at 25˚C unless otherwise specified.
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➅
Input circuitry incorporates active current limiter.
Heat sinking required, for derating curves see page 2.
24 Vac Input option, E suffix.
Turn-on time for random turn-on versions
is 0.02 msec (DC Control Models).
FastFax Document No. 158
SERIES HA/HD.
REV. 111303
PAGE 1 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series HA, HD
12-90Amp • 480 Vac - AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
8 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Terminals:
AVAILABLE OPTIONS
E
24 VAC Input (18-36 Vac)
Example: HA4825E
F
Thermally Conductive Epoxy
Screws and Saddle Clamps Furnished, Unmounted
Faston Terminals (Up to 50 Amp Models)
Example: HD4850F
Input Status LED.
Agencies Approval Pending
Example: HD4850G
Note: Control Voltage Range 4.5-32 Vdc
for DC Control Models.
G
P
Internal Overvoltage Protection.
Relay Will Self Trigger Between
900-1200 Vpk. Not Suitable For
Capacitive Loads.
Agencies Approval Pending.
Example: HD4825P
-10
H
Random Turn-On (AC & DC Control)
Phase Controllable (DC Control)
Example: HD4890-10
Heat Transfer Pad (Attached)
Example: HD4890H
Ordering System: Combination of the
suffixes should be made in the following order:
EFPG-10.
Example: HA4850EFPG-10
Crydom Heat Sinks offer excellent
thermal management and are perfectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom’s Heat Sink
specification sheet for all the details.
APPROVALS
UL E116949
CSA LR81689
VDE 10143 UG
FastFax Document No. 158
SERIES HA/HD.
REV. 111303
PAGE 2 OF 3
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1
OUTPUT
8-32 TERMINAL
(2 PLACES )
2
1.87
(47.5)
-4
3
1.00
(25.4)
1.80
(45.7)
BASE PLATE
.125 (3.2)
Screw Torque Requirements:
6-32 Screws - 10 in. lbs.,
8-32 and 10-32 Screws - 20in. lbs.
(Screws dry without grease.)
MOUNTING
6-32 TERMINAL
(2 PLACES)
1.10
(27.9)
.45
(11.4)
HOLE/SLOT
0.17 (4.3) DIA.
Fastons:
Single pair (up to 25A)
Double pair* (up to 50A).
*Caution: User must connect to both pairs
+
INPUT
1
OUTPUT
-4
2
+
INPUT
1.00
(25.4)
1.80
(45.7)
.78
(19.8)
.90
(22.9)
FASTON TERMINAL
.250 X .032 (2 PLCS.)
.87 REF.
(22.2)
1.87
(47.5)
BASE PLATE
.125 (3.2)
2.30
(58.4)
1.70
(43.2)
2.30
(58.4)
1.70
(43.2)
3
FASTON
TERMINAL
.187 X .032
(2 PLCS.)
.78
(19.8)
.90
(22.9)
All dimensions are in inches (millimeters)
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series HA, HD
12-90Amp • 480 Vac - AC OUTPUT
CURRENT DERATING CURVES
12A
14
25A
12
30
110
5˚C/W
8
NO HEATSINK
6
115
4
120
4
6
8
10
12
40
60
5
80
20
60
80
Max Ambient Temp. [˚C]
40
60
80
90
1˚C/W
110
40
.2˚C/W
.4˚C/W
Power Dissipation
100
80
Base Plate Temp [˚C]
.3˚C/W
.5˚C/W
80
100
1ºC/W
110
40
120
120
0
40
20
Max Ambient Temp. [˚C]
90A
120
NO HEATSINK
0
20
25
120
95
Power Dissipation
110
20
50
15
.5˚C/W
Base Plate Temp [˚C]
100
2˚C/W
40
10
Load Current [Arms]
90
40
30
120
75A
.5˚C/W
1.5˚C/W
Power Dissipation
20
Max Ambient Temp. [˚C]
120
20
110
10
0
15
30
45
60
Load Current [Arms]
75
20
40
60
80
Max Ambient Temp. [˚C]
20
40
60
80
0
Load Current [Arms]
20
40
60
80
Max Ambient Temp. [˚C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No. 158
SERIES HA/HD.
REV. 111303
PAGE 3 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Base Plate Temp [˚C]
2
50A
Load Current [Arms]
15
0
0
60
1˚C/W
2˚C/W
5
Load Current [Arms]
10
3˚C/W
20
NO HEATSINK
2
0
100
Base Plate Temp [˚C]
9˚C/W
95
1˚C/W
25
Power Dissipation
Power Dissipation
10
3˚C/W
Base Plate Temp [˚C]
7˚C/W
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series HA/HD60
25-125Amp • 600 Vac - AC OUTPUT
• Zero Voltage and Random
Turn-On Switching
• Panel Mount
• 1200V Blocking Capability
• 600Vac - the preferred
choice in Canada
• Integrated Overvoltage
Protection by Automatic
Self Turn-On (Suffix P)
HA6025
HD6025
HA6050
HD6050
HA6090
HD6090
HA60125
HD60125
OUTPUT SPECIFICATIONS ➀
Nominal Line Voltage (±10%) [Vrms]
600
600
600
600
Operating Voltage Range (47-63 Hz) [Vrms]
48-660
48-660
48-660
48-660
Max. Load Current ➂ [Arms]
25
50
90
125
Min. Load Current, [mArms]
40
40
40
150
Transient Overvoltage [Vpk]
1200
1200
1200
1200
Max. Surge Current, (16.6ms) [Apk]
250
625
1,200
1,750
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.7
1.7
1.7
1.7
Thermal Resistance Junction to Case (R θJC) [˚ C/W]
1.02
0.63
0.28
0.22
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
260
1,620
6,000
12,700
5
5
5
5
500
500
500
500
MODEL NUMBERS
AC CONTROL
D C CONTROL
Featuring state-of-the-art Surface
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications.
Output consists of an SCR AC switch
and is available in zero-cross, random
turn-on (phase controllable) and versions with either AC or DC input (coil)
control.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
Max. Off-State Leakage Current @ Rated Voltage [mArms]
➆
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁
Max. Turn-On Time
➄
1/2 Cycle (DC Input), 10.0 msec (AC Input)
1/2 Cycle (DC Input), 40.0 msec (AC Input)
Max. Turn-Off Time
0.5
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
DC CONTROL
(D PREFIX)
0.5
0.5
0.5
AC CONTROL
(A PREFIX) ➃
AC CONTROL
(E SUFFIX)
Control Voltage Range
3-32 Vdc
90-280 Vrms (60Hz)
18-36 Vrms
Max. Reverse Voltage
-32 Vdc
---
---
Max. Turn-On Voltage
3.0 Vdc
90 Vrms
18 Vrms
Min. Turn-Off Voltage
1.0 Vdc
10 Vrms
4.0 Vrms
See Note ➅
60K Ohms
9.0K Ohms
2.0 mA ➅
2mA @ 120 Vrms, 4mA @ 240 Vrms
3mA @ 24 Vrms
Nominal Input Impedance
Typical Input Current
© 2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25˚C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ 24 Vac Input option, E suffix.
➄ Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).
➅ Input circuitry incorporates active current limiter.
➆ No internal snubber.
FastFax Document No.159
SERIES HA/HD60.
Rev. 111303
PAGE 1 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series HA/HD60
25-125Amp • 600 Vac - AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
8 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
AVAILABLE OPTIONS
E
24 VAC Input (18-36 Vac)
Example: HA6025E
F
Screws and Saddle Clamps Furnished, Unmounted
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
Faston Terminals (Up to 50 Amp Models)
Example: HD6050F
Input Status LED.
Agencies Approval Pending
Example: HD6050G
Note: Control Voltage Range 4.5-32Vdc
for DC Control Models.
G
P
Internal Overvoltage Protection.
Relay Will Self Trigger Between
900-1200 Vpk. Not Suitable For
Capacitive Loads.
Agencies Approval Pending.
Example: HD6025P
-10
Random Turn-On (AC & DC Control)
Phase Controllable (DC Control)
Example: HD6090-10
H
Heat Transfer Pad (Attached)
Example: HD6090H
Ordering System: Combination of the
suffixes should be made in the following order:
EFPG-10.
Example: HA6050EFPG-10
1
Screw Torque Requirements:
6-32 Screws - 10 in./lbs.,
8-32 and 10-32 Screws - 20in./lbs.
(Screws dry without grease.)
1.10
(27.9)
.45
(11.4)
8-32 TERMINAL
(2 PLACES )
OUTPUT
2
1.87
(47.5)
-4
+
3
INPUT
1.00
(25.4)
1.80
(45.7)
BASE PLATE
.125 (3.2)
Fastons:
Single pair (up to 25A)
Double pair* (up to 50A).
* Caution: User must connect to both pairs
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1
1
6-32 TERMINAL
(2 PLACES)
1.10
(27.9)
.45
(11.4)
.78
(19.8)
.90
(22.9)
FASTON TERMINAL
.250 X .032 (2 PLCS.)
.87 REF.
(22.2)
OUTPUT 2
2
1.87
(47.5)
2.30
(58.4)
1.70
(43.2)
44
BASE PLATE
.125 (3.2)
2.30
(58.4)
1.70
(43.2)
INPUT
1.00
(25.4)
1.80
(45.7)
3
3
FASTON
TERMINAL
.187 X .032
(2 PLCS.)
.78
(19.8)
.90
(22.9)
Crydom Heat Sinks offer excellent
thermal management and are perfectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom’s Heat Sink
specification sheet for all the details.
All dimensions are in inches (millimeters)
APPROVALS
UL
E116950
CSA LR81689
VDE 10143 UG
FastFax Document No.159
SERIES HA/HD60.
Rev. 111303
PAGE 2 OF 3
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series HA/HD60
25-125Amp • 600 Vac - AC OUTPUT
CURRENT DERATING CURVES
50A
25A
60
95
1˚C/W .5˚C/W
3˚C/W 2˚C/W
20
15
110
10
NO HEATSINK
5
Power Dissipation
40
100
2˚C/W
110
20
120
120
NO HEATSINK
0
0
15
20
25
20
40
60
10
80
90A
.5˚C/W
30
40
50
20
80
100
1˚C/W
110
40
60
80
160
90
.2˚C/W
.4˚C/W
40
Max Ambient Temp. [˚C]
125A
90
120
20
Load Current [Arms]
Max Ambient Temp. [˚C]
.4˚C/W
Power Dissipation
10
Load Current [Arms]
Base Plate Temp [˚C]
5
Power Dissipation
90
1.5˚C/W
120
.5˚C/W
.2˚C/W
100
80
1˚C/W
110
40
120
0
Base Plate Temp [˚C]
Power Dissipation
100
Base Plate Temp [˚C]
1˚C/W
25
Base Plate Temp [˚C]
30
120
0
20
40
60
80
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
30
60
90 120
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No.159
SERIES HA/HD60.
Rev. 111303
PAGE 3 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series H12C
50-90Amp • 480 Vac • AC OUTPUT
•
•
•
•
1200 Volt Blocking
Panel Mount
Up to 660 Vac
Zero Voltage and Random
Turn-On
• SCR Output
• Integrated Overvoltage
Protection by Automatic
Self Turn-On (Suffix P)
High voltage relays use IC driven circuits for switching loads up to 660
VAC. All models come with 1200
Volts blocking and are available with
either AC or DC input (coil) control.
Types H12CA and H12CD are
snubberless (reduced leakage current).
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
M O D E L N U M B E R S DC CONTROL
H12CD4850
H12CD4890
AC CONTROL
H12CA4850
H12CA4890
48-660
48-660
Max. Load Current ➂ [Arms]
50
90
Min. Load Current, [mArms]
150
150
Transient Overvoltage [Vpk]
1200
1200
Max. Surge Current, (16.6ms) [Apk]
625
1200
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
Thermal Resistance Junction to Case (R θJC) [˚ C/W]
.63
.28
1620
6000
Max. Off-State Leakage Current @ Rated Voltage [mArms]
1.0
1.0
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁
500
500
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms]
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
Max. Turn-On Time
➃
1/2 Cycle (DC Control), 10.0 msec (AC Control)
1/2 Cycle (DC Control), 40.0 msec (AC Control)
Max. Turn-Off Time
0.5
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
DC CONTROL
0.5
AC CONTROL
(H12CD PREFIX)
(H12CA PREFIX)
Control Voltage Range
4-15 Vdc
90-140 Vrms
Max. Turn-On Voltage
4.0 Vdc
90 Vrms
Min. Turn-Off Voltage
1.0 Vdc
10.0 Vrms
300 Ohms
8K Ohms
15 mA @ 5 Vdc
15 mA @ 120 Vrms
Nominal Input Impedance
Typical Input Current
© 2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25˚C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ Turn-on time for DC control random turn-on versions is 0.02 msec.
SERIES H12C.
REV. 111203
PAGE 1 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series H12C
50-90Amp • 480 Vac • AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
8 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Terminals:
Crydom Heat Sinks offer excellent thermal management and are perfectly
matched to the load current ratings of
Crydom panel mount relays. Request
Crydom’s Heat Sink specification sheet
for all the details.
Thermally Conductive Epoxy
Screws and Saddle Clamps Furnished, Unmounted
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1
1.10
(27.9)
.45
(11.4)
OUTPUT
8-32 TERMINAL
(2 PLACES )
2
1.87
(47.5)
-4
+
INPUT
2.30
(58.4)
1.70
(43.2)
3
Available Options
F
Faston Terminals.
(50 Amp Models Only)
Example: H12CD4850F
G
Input Status LED.
Agencies Approval Pending
Example: H12CD4850G
Note: Control Voltage Range 5.5-15Vdc
for DC Control Models.
Internal Overvoltage Protection.
Relay Will Self Trigger Between
900-1200Vpk. Not Suitable For
Capacitive Loads.
Agencies Approval Pending
Example: H12CD4850P
P
-10
H
1.00
(25.4)
1.80
(45.7)
BASE PLATE
.125 (3.2)
Ordering System: Combination of the
suffixes should be made in the following order:
FPG-10.
Example: H12CD4850FPG-10
.78
(19.8)
.90
(22.9)
Screw Torque Requirements:
*6-32 Screws - 10 in. lbs.,
8-32 and 10-32 Screws - 20in. lbs.
(Screws dry without grease.)
Fastons:
Double pair* (50A model only).
Caution: User must connect to both pairs
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
Random Turn-On.
Example: H12CD4850-10
Heat Transfer Pad (Attached)
Example: H12CD4850H
6-32 TERMINAL
(2 PLACES)
1
OUTPUT
FASTON TERMINAL
.250 X .032 (2 PLCS.)
.87 REF.
(22.2)
2
1.87
(47.5)
+
--
4
BASE PLATE
.125 (3.2)
INPUT
1.00
(25.4)
1.80
(45.7)
2.30
(58.4)
1.70
(43.2)
3
FASTON
TERMINAL
.187 X .032
(2 PLCS.)
.78
(19.8)
.90
(22.9)
All dimensions are in inches (millimeters)
APPROVALS
UL
E116949
CSA LR81689
VDE 10143 UG
SERIES H12C.
Rev. 111203
PAGE 2 OF 3
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series H12C
50-90Amp • 480 Vac • AC OUTPUT
CURRENT DERATING CURVES
50A
90A
.5˚C/W
90
100
2˚C/W
110
20
20
30
40
Load Current [Arms]
50
20
40
60
80
80
Max Ambient Temp. [˚C]
100
1˚C/W
110
40
120
120
NO HEATSINK
0
10
.2˚C/W
.4˚C/W
Power Dissipation
1.5˚C/W
40
.5˚C/W
Base Plate Temp [˚C]
1˚C/W
Power Dissipation
90
120
Base Plate Temp [˚C]
60
0
20
40
60
80
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
SERIES H12C.
Rev. 111203
PAGE 3 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series H12D
25-90Amp • 480 Vac - AC OUTPUT
•
•
•
•
1200 Volt Blocking
Panel Mount
Up to 530 Vac
Zero Voltage and Random
Turn-On
• SCR Output
• Integrated Overvoltage
Protection by Automatic
Self Turn-On (Suffix P)
High voltage relays use IC driven circuits for switching loads up to 660
VAC. All models come with 1200
Volts blocking and are available with
either AC or DC input (coil) control.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
H12D4825 H12D4850
MODEL NUMBERS
H12D4875 H12D4890
OUTPUT SPECIFICATIONS ➀
48-530
48-530
48-530
48-530
25
50
75
90
Min. Load Current, [mArms]
150
150
150
150
Transient Overvoltage [Vpk]
1200
1200
1200
1200
Max. Surge Current, (16.6ms) [Apk]
250
625
1000
1200
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
Thermal Resistance Junction to Case (R JC) [˚C/W]
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
1.02
.63
.31
.28
260
1620
4150
6000
10
10
10
10
500
500
500
500
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current
➂
[Arms]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁
Max. Turn-On Time
➃
Max. Turn-Off Time
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
0.5
Power Factor (Min.) with Max. Load
0.5
0.5
0.5
INPUT SPECIFICATIONS ➀
Control Voltage Range
4-32Vdc
Max. Turn-On Voltage
4.0 Vdc
Min. Turn-Off Voltage
1.0 Vdc
See Note 5
Nominal Input Impedance
15 mA @ 5 Vdc ➄
Typical Input Current
© 2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25˚ C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ Turn-on time for DC control random turn-on versions is 0.02 msec.
➄ Input circuitry incorporates active current limiter.
FastFax Document No.157
SERIES H12D.
Rev. 111203
PAGE 1 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series H12D
25-90Amp • 480 Vac - AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
8 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Terminals:
Available Options
F
P
H
Screws and Saddle Clamps Furnished, Unmounted
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
Faston Terminals.
(Up to 50 Amp Models)
Example: H12D4850F
G
Thermally Conductive Epoxy
1
OUTPUT
-4
+
INPUT
6-32 TERMINAL
(2 PLACES)
.78
(19.8)
.90
(22.9)
Screw Torque Requirements:
6-32 Screws - 10 in. lbs.,
8-32 and 10-32 Screws - 20in. lbs.
(Screws dry without grease.)
Fastons:
Single pair (up to 25A)
Double pair* (up to 50A).
*Caution: User must connect to both pairs
Heat Transfer Pad (Attached)
Example: H12D4850H
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
Ordering System: Combination of the
suffixes should be made in the following order:
FPG-10.
Example: H12D4850FPG-10
1
OUTPUT
FASTON TERMINAL
.250 X .032 (2 PLCS.)
.87 REF.
(22.2)
2
1.87
(47.5)
+
--
4
Crydom Heat Sinks offer excellent ther
mal management and are perfectly
matched to the load current ratings ofCrydom panel mount relays. Request
Crydom’s Heat Sink specification sheet
for all the details.
FastFax Document No.157
SERIES H12D.
Rev. 111203
PAGE 2 OF 3
2.30
(58.4)
1.70
(43.2)
3
1.00
(25.4)
1.80
(45.7)
BASE PLATE
.125 (3.2)
Internal Overvoltage Protection.
Relay Will Self Trigger Between
900-1200Vpk. Not Suitable For
Capacitive Loads.
Agencies Approval Pending.
Example: H12D4850P
UL
E116949
CSA LR81689
VDE 10143 UG
2
1.87
(47.5)
Input Status LED.
Agencies Approval Pending
Example: H12D4850G
Note: Control Voltage Range 5.5-32 Vdc
APPROVALS
8-32 TERMINAL
(2 PLACES )
BASE PLATE
.125 (3.2)
INPUT
1.00
(25.4)
1.80
(45.7)
2.30
(58.4)
1.70
(43.2)
3
FASTON
TERMINAL
.187 X .032
(2 PLCS.)
.78
(19.8)
.90
(22.9)
All dimensions are in inches (millimeters)
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series H12D
25-90Amp • 480 Vac - AC OUTPUT
CURRENT DERATING CURVES
25A
50A
95
60
1˚C/W
2˚C/W
20
15
110
10
NO HEATSINK
5
.5˚C/W
90
1.5˚C/W
Power Dissipation
40
100
2˚C/W
110
20
120
120
NO HEATSINK
0
5
10
15
20
25
Load Current [Arms]
20
40
60
0
80
10
Max Ambient Temp. [˚C]
20
30
40
50
Load Current [Arms]
20
40
60
90A
75A
90
120
120
100
80
1˚C/W
110
40
.2˚C/W
.4˚C/W
Power Dissipation
95
.3˚C/W
.5˚C/W
Base Plate Temp [˚C]
.5˚C/W
Power Dissipation
80
Max Ambient Temp. [˚C]
80
100
1˚C/W
110
40
Base Plate Temp [˚C]
Power Dissipation
100
3˚C/W
Base Plate Temp [˚C]
1˚C/W
25
Base Plate Temp [˚C]
30
120
120
0
0
15
30
45
60
Load Current [Arms]
75
20
40
60
80
Max Ambient Temp. [˚C]
20
40
60
80
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No.157
SERIES H12D.
Rev. 111203
PAGE 3 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series H12WD
25-125Amp • 480 Vac - AC OUTPUT
• 1200 Volt Blocking
• Panel Mount
• Up to 660 Vac
• Zero Voltage and Random
Turn-On
• SCR Output
• Integrated Overvoltage
Protection by Automatic
Self Turn-On (Suffix P)
MODEL NUMBERS
H12WD4825
H12WD4850
48-660
48-660
High voltage relays use IC driven circuits for switching loads up to 660
VAC. All models come with 1200
Volts blocking.
Type H12WD is a snubberless
(reduced leakage current).
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
H12WD4875 H12WD4890
➅
H12WD48125
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms]
48-660
48-660
48-660
Max. Load Current ➂ [Arms]
25
50
75
90
125
Min. Load Current, [mArms]
150
150
150
150
150
Transient Overvoltage [Vpk]
1200
1200
1200
1200
1200
Max. Surge Current, (16.6ms) [Apk]
250
625
1000
1200
1750
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
1.7
Thermal Resistance Junction to Case (R θJC) [˚C/W]
1.02
.63
.31
.28
.22
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
260
1620
4150
6000
12700
Max. Off-State Leakage Current @ Rated Voltage [mArms]
1.0
1.0
1.0
1.0
1.0
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁
500
500
500
500
500
Max. Turn-On Time ➃
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
Max. Turn-Off Time
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
0.5
0.5
0.5
Power Factor (Min.) with Max. Load
0.5
0.5
INPUT SPECIFICATIONS ➀
Control Voltage Range
4-32 Vdc
Max. Turn-On Voltage
4.0 Vdc
Min. Turn-Off Voltage
1.0 Vdc
Nominal Input Impedance
See Note 5
15 mA @ 5 Vdc ➄
Typical Input Current
© 2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25˚C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ Turn-on time for DC control random turn-on versions is 0.02 msec.
➄ Input circuitry incorporates active current limiter.
Compliant only.
➅
SERIES H12WD.
Rev. 111203
PAGE 1 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series H12WD
25-125Amp • 480 Vac - AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
8 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Terminals:
Thermally Conductive Epoxy
Screws and Saddle Clamps Furnished, Unmounted
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
Crydom Heat Sinks offer excellent thermal management and are perfectly
matched to the load current ratings of
Crydom panel mount relays. Request
Crydom’s Heat Sink specification sheet
for all the details.
OUTPUT
1
--
G
P
-10
H
INPUT
6-32 TERMINAL
(2 PLACES)
.78
(19.8)
.90
(22.9)
Screw Torque Requirements:
6-32 Screws - 10 in. lbs.,
8-32 and 10-32 Screws - 20in. lbs.
(Screws dry without grease.)
Internal Overvoltage Protection.
Relay Will Self Trigger Between
900-1200Vpk. Not Suitable For
Capacitive Loads.
Agencies Approval Pending.
Example: H12WD4850P
Fastons:
Single pair (up to 25A)
Double pair* (up to 50A).
*Caution: User must connect to both pairs
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1
OUTPUT
FASTON TERMINAL
.250 X .032 (2 PLCS.)
.87 REF.
(22.2)
2
1.87
(47.5)
+
--
Ordering System: Combination of the
suffixes should be made in the following order:
FPG-10.
Example: H12WD4850FPG-10
2.30
(58.4)
1.70
(43.2)
3
1.00
(25.4)
1.80
(45.7)
BASE PLATE
.125 (3.2)
Input Status LED.
Agencies Approval Pending
Example: H12WD4850G
Note: Control Voltage Range 5.5-32 Vdc
Heat Transfer Pad (Attached)
Example: H12WD4850H
+
4
Faston Terminals.
(Up to 50 Amp Models)
Example: H12WD4850F
Random Turn-On.
Example: H12WD4850-10
2
1.87
(47.5)
Available Options
F
8-32 TERMINAL
(2 PLACES )
4
BASE PLATE
.125 (3.2)
INPUT
1.00
(25.4)
1.80
(45.7)
2.30
(58.4)
1.70
(43.2)
3
FASTON
TERMINAL
.187 X .032
(2 PLCS.)
.78
(19.8)
.90
(22.9)
All dimensions are in inches (millimeters)
© 2003 CRYDOM CORP, Specifications subject to change without notice.
APPROVALS
UL
E116949
CSA LR81689
VDE 10143 UG
SERIES H12WD.
Rev. 111203
PAGE 2 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series H12WD
25-125Amp • 480 Vac - AC OUTPUT
CURRENT DERATING CURVES
25A
50A
95
60
1˚C/W
3˚C/W
2˚C/W
20
15
110
10
NO HEATSINK
5
.5˚C/W
90
1.5˚C/W
Power Dissipation
40
100
2˚C/W
110
20
120
120
NO HEATSINK
0
5
10
15
20
25
Load Current [Arms]
20
40
60
0
80
10
Max Ambient Temp. [˚C]
20
30
40
50
Load Current [Arms]
20
40
60
90A
75A
90
120
120
100
80
1˚C/W
110
40
.2˚C/W
.4˚C/W
Power Dissipation
95
.3˚C/W
.5˚C/W
Base Plate Temp [˚C]
.5˚C/W
Power Dissipation
80
Max Ambient Temp. [˚C]
80
100
1˚C/W
110
40
Base Plate Temp [˚C]
Power Dissipation
100
Base Plate Temp [˚C]
1˚C/W
25
Base Plate Temp [˚C]
30
120
120
0
0
15
30
45
60
Load Current [Arms]
75
20
40
60
20
80
40
60
80
0
Load Current [Arms]
Max Ambient Temp. [˚C]
20
40
60
80
Max Ambient Temp. [˚C]
125A
160
Power Dissipation
.5˚C/W
.2˚C/W
100
80
1˚C/W
110
40
Base Plate Temp [˚C]
90
.4˚C/W
120
120
0
30
60
90 120
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
SERIES H12WD.
Rev. 111203
PAGE 3 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series 1-DC
7-40Amp • 0-500 Vdc - DC OUTPUT
DC output relays feature MOSFET tech
nology for low on-state resistance,
assuring easy paralleling and switching
capabilities to 40 amps at 100 Vdc.
Lower current models are also available
to 500 Vdc. All models come in
Crydom's standard panel-mount package.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
• M OSFET Output
• Low On-State Resistance
• Paralleling Capability for
Higher Currents
• Panel M ount
OUTPUT SPECIFICATIONS ➀
MODEL NUMBERS
Operating Voltage Range [Vdc]
Max. Load Current ➂ [Adc]
D1D07 D1D12 D1D20 D1D40
D2D07 D2D12
D4D07 D4D12
D5D07 D5D10
0-100
0-200 0-200
0-400 0-400
0-500 0-500
0-100 0-100 0-100
7
12
20
40
7
12
7
12
7
10
Min. Load Current [mA]
20
20
20
20
20
20
20
20
20
20
Max. Surge Current, [Adc] (10Msec)
15
28
42
106
22
27
17
36
19
29
Max. On-State Voltage Drop @ Rated Current [Vdc]
2.0
1.6
2.1
2.1
2.0
2.8
4.2
4.2
5.7
5.5
Thermal Resistance Junction to Case [RθJC] C/W
2.2
1.34
1.06
0.83
1.5
1.06
1.06
0.8
1.0
0.8
Max On-state Resistance @ Rated Current (RDS-ON) [Ohms]
.29
.13
.10
.05
.29
.23
.6
.35
.8
.55
Max. Off-State Leakage Current @ Rated Voltage [mA]
0.1
0.2
0.3
0.3
0.1
0.3
0.3
0.3
0.2
0.3
Max. Turn-On Time [µsec]
100
100
100
100
100
100
100
100
100
100
Max. Turn-Off Time [msec]
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
INPUT SPECIFICATIONS ➀
DC CONTROL
3.5-32 Vdc
Control Voltage Range
Maximum Turn-On Voltage
3.5 Vdc
Minimum Turn-Off Voltage
1.0 Vdc
See Note 4
Nominal Input Impedance
1.6 mA (5 Vdc), 28 mA (32 Vdc) ➃
Maximum Input Current
GENERAL NOTES
©2003 CRYDOM CORP, Specifications subject to change without notice.
➀ All parameters at 25ºC unless otherwise specified.
➁ Dielectric strength and insulation resistance are measured between input and output.
➂ Heat sinking required, for derating curves see page 3.
➃ Input circuitry incorporates active current limiter.
FastFax Document No. 164
SERIES 1DC.
Rev. 111003
PAGE 1 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series 1-DC
7-40Amp • 0-500 Vdc - DC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 60Hz
2500 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
50 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-20 to 80ºC
Ambient Storage Temperature Range
-20 to 125ºC
M ECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
Screws and Saddle Clamps Furnished, Unmounted
M AXIM UM SURGE vs . DURATION
1.10
(27.9)
.45
(11.4)
8-32 TERMINAL
(2 PLACES )
60
D1D20
-1.87
(47.5)
+
OUTPUT
1
--
2.30
(58.4)
1.70
(43.2)
2
4
MAX. SURGE CURRENT (Amps)
55
3
+
INPUT
1.00
(25.4)
1.80
(45.7)
6-32 TERMINAL
(2 PLACES)
50
45
40
D1D12
D2D12
35
30
25
20
15
D2D07
D1D07
10
5
.78
(19.8)
.90
(22.9)
2
3 4 5 6 8 10
2 3 4 5 6 8102
2 3 4 5 6 8103
SURGE DURATION (msec)
2
3 4 5 6 8104
2
3 4 5 6 8104
2
3 4 5 6 8104
All dimensions are in inches (millimeters)
60
Input and output polarity must be observed.
Inductive loads must be diode suppressed.
4 (–)
55
MAX. SURGE CURRENT (Amps)
Screw Torque Requirements: 6-32 Screws - 10 in. lbs., 8-32 and
10-32 Screws - 20in. lbs. (Screws dry without grease.)
50
D4D12
45
40
35
D5D10
30
25
D4D07
20
D5D07
15
10
5
2
1 (–)
3 4 5 6 8 10
2 3 4 5 6 8102
2 3 4 5 6 8103
SURGE DURATION (msec)
3 4 5 6 8 10
2
3 (+)
2 (+)
(–)
(+)
Transient Protection
All loads are inductive, even ones that are not so labeled. An
inductive load will produce harmful transient voltages when it
is turned off. The more perfect the switch, the larger the transient voltages; the MOSFET output is so nearly an ideal switch
that the transient voltages produced by seemingly "non-inductive" loads can cause damage if not suppressed. Diodes should
be fast recovery type with PIV rated greater than supply voltage.
200
MAX. SURGE CURRENT (Amps)
SSR
OUTPUT
DC
CONTROL
SOURCE
INPUT
LOAD
D1D40
150
100
50
2
3 4 5 6 8102
2
3 4 5 6 8103
SURGE DURATION (msec)
©2003 CRYDOM CORP, Specifications subject to change without notice.
APPROVALS
UL
E116950 (100 Volt Models Only)
FastFax Document No. 164
SERIES 1DC.
Rev. 111003
PAGE 2 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series 1-DC
7-40Amp • 0-500 Vdc - DC OUTPUT
Crydom Heat Sinks offer excellent
thermal management and are perfectly matched to the load current ratings
of Crydom panel mount relays.
Request Crydom’s Heat Sink specification sheet for all the details.
CURRENT DERATING CURVES
D1D07 - 7A
D1D12 - 12A
4ºC/W
12
6ºC/W
8
NO HEATSINK
4
120
5 6
20
7
Load Current [Adc]
40
60
80
2
Max Ambient Temp. [ºC]
4
6
8
Load Current [Adc]
D1D40 - 40A
20
40
60
80
Max Ambient Temp. [ºC]
100
2ºC/W
120
140
0
24
32
40
20
Load Current [Adc]
40
60
2ºC/W
100
4ºC/W
12
6ºC/W
9
110
6
NO HEATSINK
2
3
20
4ºC/W
110
6ºC/W
10
NO HEATSINK
120
5
6 7
20
40
60
60
2ºC/W
110
6ºC/W
10
2
4
6
100
110
4ºC/W
20
8
10 12
20
2ºC/W
30
105
4ºC/W
20
10
120
NO HEATSINK
0
2
4
6
8
Load Current [Adc]
FastFax Document No. 164
SERIES 1DC.
Rev. 111003
PAGE 3 OF 3
10
20
40
60
80
Max Ambient Temp. [ºC]
60
80
40
60
85
1ºC/W
30
2ºC/W
20
4ºC/W
100
80
Max Ambient Temp. [ºC]
110
6ºC/W
10
120
NO HEATSINK
0
1
2
3
4
5
6 7
Load Current [Adc]
Base Plate Temp [ºC]
90
40
40
40
120
NO HEATSINK
6
20
Max Ambient Temp. [ºC]
D5D07 - 7A
30
4
10 12
8
Load Current [Adc]
0.5ºC/W
1ºC/W
120
NO HEATSINK
20
40
60
80
Max Ambient Temp. [ºC]
©2003 CRYDOM CORP, Specifications subject to change without notice.
75
50
100
4ºC/W
20
80
1ºC/W
Load Current [Adc]
D5D10 - 10A
60
Power Dissipation
40
2ºC/W
2
80
Max Ambient Temp. [ºC]
120
80
Max Ambient Temp. [ºC]
30
Max Ambient Temp. [ºC]
40
0
4
60
1ºC/W
85
0.5ºC/W
10
0
3
20
50
Power Dissipation
100
2
6 7
60
Base Plate Temp [ºC]
Power Dissipation
30
40
85
D4D12 - 12A
D4D07 - 7A
Load Current [Adc]
5
4
Load Current [Adc]
1ºC/W
20
0
Max Ambient Temp. [ºC]
2ºC/W
20
120
1
85
16
40
0
80
40
1
12
D2D12 - 12A
3
NO HEATSINK
16
8
Load Current [Adc]
95
15
Power Dissipation
1ºC/W
1.5ºC/W
Base Plate Temp [ºC]
60
8
4
18
80
0.2ºC/W
0.5ºC/W
110
6ºC/W
D2D07 - 7A
90
30
10 12
Power Dissipation
4
Power Dissipation
3
15
NO HEATSINK
Base Plate Temp [ºC]
2
100
4ºC/W
0
Base Plate Temp [ºC]
1
90
2ºC/W
120
0
0
Power Dissipation
110
1ºC/W
30
Base Plate Temp [ºC]
NO HEATSINK
4
100
16
Base Plate Temp [ºC]
110
2ºC/W
Base Plate Temp [ºC]
6ºC/W
8
80
45
Power Dissipation
100
90
20
Power Dissipation
4ºC/W
Base Plate Temp [ºC]
Power Dissipation
2ºC/W
12
D1D20 - 20A
24
90
Base Plate Temp [ºC]
16
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Series 1-DCL
7-40Amp • 0-500 Vdc - DC OUTPUT
• MOSFET Output
• Low On-State Resistance
• Paralleling Capability for
Higher Currents
• Panel Mount
• Optically Coupled
DC output relays feature MOSFET technology for low on-state resistance,
assuring easy paralleling and switching
capabilities to 40 amps at 100 Vdc.
Lower current models are also available
to 500 Vdc. All models come in
Crydom's standard panel-mount package.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
OUTPUT SPECIFICATIONS➀
M O D E L N U M B E R S D1D07L D1D12L D1D20L D1D40L D2D07L D2D12L D4D07L D4D12L D5D07L D5D10L
Operating Voltage Range [Vdc]
➂ [Adc]
0-100
0-100 0-100
0-100
0-200 0-200
0-400 0-400
0-500 0-500
7
12
20
40
7
12
7
12
7
10
Min. Load Current [mA]
20
20
20
20
20
20
20
20
20
20
Max. Surge Current, [Adc] (10msec)
15
28
42
106
22
27
17
36
19
29
Max. On-State Voltage Drop @ Rated Current [Vdc]
2.0
1.6
2.1
2.1
2.0
2.8
4.2
4.2
5.7
5.5
Thermal Resistance Junction to Case [R θJC ]˚C/W
2.2
1.34
1.06
0.83
1.5
1.06
1.06
0.8
1.0
0.8
Max On-state Resistance @ Rated Current (R DS-ON ) [Ohms]
.29
.13
.10
.05
.29
.23
.6
.35
.8
.55
Max. Off-State Leakage Current @ Rated Voltage [mA]
0.1
0.2
0.3
0.3
0.1
0.3
0.3
0.3
0.2
0.3
Max. Turn-On Time [msec]
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Max. Turn-Off Time [msec]
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
Max. Load Current
INPUT SPECIFICATIONS ➀
DC CONTROL
3.5-32 Vdc
Control Voltage Range
Maximum Turn-On Voltage
3.5 Vdc
Minimum Turn-Off Voltage
1.0 Vdc
Nominal Input Impedance
See Note 4
20mA ➃
Typical Input Current
GENERAL NOTES
© 2003 CRYDOM CORP, Specifications subject to change without notice.
➀ All parameters at 25˚C unless otherwise specified.
➁ Dielectric strength and insulation resistance are measured between input and output.
➂ Heat sinking required, for derating curves see page 3.
➃ Input circuitry incorporates active current limiter.
FastFax Document No.
SERIES 1DCL.
Rev. 102704
PAGE 1 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Series 1-DCL
7-40Amp • 0-500 Vdc - DC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 60Hz
2500 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
50 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
MAXIMUM SURGE vs. DURATION
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
Screws and Saddle Clamps Furnished, Unmounted
8-32 TERMINAL
(2 PLACES )
60
D1D20
-1.87
(47.5)
+
OUTPUT
1
2.30
(58.4)
1.70
(43.2)
2
4
3
--
MAX. SURGE CURRENT (Amps)
55
+
INPUT
1.00
(25.4)
1.80
(45.7)
6-32 TERMINAL
(2 PLACES)
50
45
40
D1D12
D2D12
35
30
25
20
15
D2D07
D1D07
10
5
.78
(19.8)
.90
(22.9)
2
3 4 5 6 8 10
2 3 4 5 6 8102
2 3 4 5 6 8103
SURGE DURATION (msec)
2
3 4 5 6 8104
2
3 4 5 6 8104
2
3 4 5 6 8104
All dimensions are in inches (millimeters)
60
Input and output polarity must be observed.
Inductive loads must be diode suppressed.
4 (–)
55
MAX. SURGE CURRENT (Amps)
Screw Torque Requirements:6-32 Screws - 10 in. lbs., 8-32 and
10-32 Screws - 20in. lbs. (Screws dry without grease.)
1 (–)
50
D4D12
45
40
35
D5D10
30
25
D4D07
20
D5D07
15
10
5
LOAD
3 (+)
2 (+)
3 4 5 6 8 10
2 3 4 5 6 8102
2 3 4 5 6 8103
SURGE DURATION (msec)
3 4 5 6 8 10
2
(–)
(+)
Transient Protection
All loads are inductive, even ones that are not so labeled. An
inductive load will produce harmful transient voltages when it
is turned off. The more perfect the switch, the larger the transient voltages; the MOSFET output is so nearly an ideal switch
that the transient voltages produced by seemingly "non-inductive" loads can cause damage if not suppressed. Diodes should
be fast recovery type with PIV rated greater than supply voltage.
MAX. SURGE CURRENT (Amps)
SSR
OUTPUT
INPUT
2
DC
CONTROL
SOURCE
200
D1D40
150
100
50
2
3 4 5 6 8102
2
3 4 5 6 8103
SURGE DURATION (msec)
© 2003 CRYDOM CORP, Specifications subject to change without notice.
APPROVALS
UL
E116950 (100 Volt Models Only)
FastFax Document No.
SERIES 1DCL.
Rev. 102704
PAGE 2 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Series 1-DCL
7-40Amp • 0-500 Vdc - DC OUTPUT
Crydom Heat Sinks offer excellent
thermal management and are perfectly matched to the load current ratings
of Crydom panel mount relays.
Request Crydom’s Heat Sink specification sheet for all the details.
CURRENT DERATING CURVES
D1D07 - 7A
D1D12 - 12A
NO HEATSINK
4˚C/W
12
6˚C/W
8
NO HEATSINK
4
120
3
4
5 6
20
7
Load Current [Adc]
40
60
80
2
Max Ambient Temp. [˚C]
4
6
8
10 12
Load Current [Adc]
D1D40 - 40A
20
40
60
80
100
2˚C/W
120
2˚C/W
100
4˚C/W
12
6˚C/W
9
110
6
NO HEATSINK
20
Load Current [Adc]
40
60
80
2
3
6 7
20
40
60
4˚C/W
110
6˚C/W
10
NO HEATSINK
120
4
5
6 7
110
6˚C/W
10
2
4
6
20
40
60
100
2˚C/W
30
110
4˚C/W
20
85
1˚C/W
30
2˚C/W
20
4˚C/W
100
30
105
4˚C/W
20
10
2
4
6
8
Load Current [Adc]
FastFax Document No.
SERIES 1DCL.
Rev. 102704
PAGE 3 OF 3
10
20
40
60
80
Max Ambient Temp. [˚C]
120
NO HEATSINK
6
8
10 12
20
40
60
80
Max Ambient Temp. [˚C]
1
2
3
4
5
Load Current [Adc]
6 7
20
40
60
80
Max Ambient Temp. [˚C]
120
NO HEATSINK
0
110
6˚C/W
10
Base Plate Temp [˚C]
90
2˚C/W
80
40
0.5˚C/W
40
60
© 2003 CRYDOM CORP, Specifications subject to change without notice.
75
1˚C/W
40
0
4
Load Current [Adc]
D5D10 - 10A
60
20
Max Ambient Temp. [˚C]
120
NO HEATSINK
2
80
Max Ambient Temp. [˚C]
50
120
D5D07 - 7A
1˚C/W
40
10 12
8
Load Current [Adc]
0
3
100
4˚C/W
NO HEATSINK
85
0.5˚C/W
10
0
2
2˚C/W
20
80
50
Power Dissipation
100
Base Plate Temp [˚C]
1˚C/W
30
Load Current [Adc]
30
Max Ambient Temp. [˚C]
60
85
1
120
80
85
D4D12 - 12A
D4D07 - 7A
Power Dissipation
5
4
Load Current [Adc]
40
20
60
0
1
Max Ambient Temp. [˚C]
2˚C/W
40
1˚C/W
Power Dissipation
40
20
Max Ambient Temp. [˚C]
120
Base Plate Temp [˚C]
32
20
40
0
24
16
140
0
16
12
D2D12 - 12A
3
8
8
Load Current [Adc]
95
15
Power Dissipation
1˚C/W
1.5˚C/W
Base Plate Temp [˚C]
60
NO HEATSINK
Power Dissipation
4
Max Ambient Temp. [˚C]
18
80
0.2˚C/W
0.5˚C/W
110
6˚C/W
D2D07 - 7A
90
30
15
NO HEATSINK
Power Dissipation
2
100
4˚C/W
0
Base Plate Temp [˚C]
1
90
2˚C/W
120
0
0
Power Dissipation
110
1˚C/W
30
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Base Plate Temp [˚C]
4
100
16
Base Plate Temp [˚C]
110
2˚C/W
Base Plate Temp [˚C]
6˚C/W
8
80
45
Power Dissipation
100
90
20
Power Dissipation
4˚C/W
Base Plate Temp [˚C]
Power Dissipation
2˚C/W
12
D1D20 - 20A
24
90
Base Plate Temp [˚C]
16
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series D06D
60-100Amp • 0-60 Vdc • DC OUTPUT
• MOSFET Output
• Low On-State Resistance
• High Current Ratings
• Panel Mount
DC output relays feature MOSFET tech-nology for low on-state resistance,
assuring easy paralleling and switching
capabilities to 100 amps at 60 Vdc.
Lower current models are also available
to 500 Vdc. All models come in
Crydom's standard panel-mount package.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
OUTPUT SPECIFICATIONS➀
MODEL NUMBERS
D06D60
D06D80
D06D100
0-60
0-60
0-60
60
80
100
5
5
5
Max. Surge Current, [Adc] (10msec)
180
220
270
Max. On-State Voltage Drop @ Rated Current [Vdc]
0.6
0.7
0.5
Thermal Resistance Junction to Case (R θJC) [C/W]
0.6
0.47
0.32
Max On-state Resistance @ Rated Current (R DS-ON) [Ohms]
.010
.008
.005
Max. Off-State Leakage Current @ Rated Voltage [mA]
0.1
0.2
0.3
Max. Turn-On Time [µsec]
300
300
300
Max. Turn-Off Time [msec]
1.0
1.0
1.0
Operating Voltage Range [Vdc]
Max. Load Current
➂ [Adc]
Min. Load Current [mA]
INPUT SPECIFICATIONS➀
DC CONTROL
3.5-32 Vdc
Control Voltage Range
Maximum Turn-On Voltage
3.5 Vdc
Minimum Turn-Off Voltage
1.0 Vdc
Nominal Input Impedance
See Note 4
1.6 mA (5 Vdc), 28 mA (32 Vdc) ➃
Maximum Input Current
GENERAL NOTES
©2003 CRYDOM CORP, Specifications subject to change without notice.
➀ All parameters at 25º C unless otherwise specified.
➁ Dielectric strength and insulation resistance are measured between input and output.
➂ Heat sinking required, for derating curves see page 2.
➃ Input circuitry incorporates active current limiter.
FastFax Document No. 450
SERIES D06D.
Rev. 111203
PAGE 1 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series D06D
60-100Amp • 0-60 Vdc • DC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 60Hz
2500 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
50 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-30 to 80ºC
Ambient Storage Temperature Range
-40 to 125ºC
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
Screws and Saddle Clamps Furnished, Unmounted
Input and output polarity must be observed.
Inductive loads must be diode suppressed.
8-32 TERMINAL
(2 PLACES )
4 (–)
LOAD
+
2
--
+
4
2.30
(58.4)
1.70
(43.2)
DC
CONTROL
SOURCE
INPUT
OUTPUT
1
SSR
(–)
3
INPUT
3 (+)
1.00
(25.4)
1.80
(45.7)
BASE PLATE
.125 (3.2)
OUTPUT
-1.87
(47.5)
1 (–)
6-32 TERMINAL
(2 PLACES)
(+)
2 (+)
Transient Protection
.78
(19.8)
.90
(22.9)
All loads are inductive, even ones that are not so labeled. An
inductive load will produce harmful transient voltages when it
is turned off. The more perfect the switch, the larger the transient voltages; the MOSFET output is so nearly an ideal switch
that the transient voltages produced by seemingly "non-inductive" loads can cause damage if not suppressed. Diodes should
be fast recovery type with PIV rated greater than supply voltage.
All dimensions are in inches (millimeters)
Screw Torque Requirements: 6-32 Screws - 10 in./lbs., 8-32 and
10-32 Screws - 20in./lbs. (Screws dry without grease.)
D06D100
D06D80
100
110
20
No Heatsink
10
120
50
100
2˚C
/W
40
30
3˚C
/W
20
No Heatsi
nk
10
110
120
Power Dissipation [W]
90
Base Plate Temperature [˚C]
3˚C
/W
Power Dissipation [W]
30
100
Base Plate Temperature [˚C]
2˚C
/W
40
1˚
C
/W
70
60
/W
˚C
0.5
90
50
70
60
/W
C
1˚
80
/W
C
5˚
0.
/W
C
5˚
0.
1˚
C
/W
60
80
80
90
100
50
2˚
C/
W
40
30
110
3˚C
/W
20
No Heats
ink
10
120
0
0
0
60
40
20
Load Current [Arms]
60
80
40
20
Ambient Temperature [˚C]
APPROVALS
Pending
FastFax Document No. 450
SERIES D06D.
Rev. 111203
PAGE 2 OF 2
0
60
40
20
Load Current [Arms]
80
80
40
20
60
Ambient Temperature [˚C]
60
100 20
40
80
40
60
20
Load Current [Arms] Ambient Temperature [˚C]
80
©2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Base Plate Temperature [˚C]
90
80
70
Power Dissipation [W]
100
90
D06D60
80
80
110
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series DC60
3-7Amp • 60 Vdc - DC OUTPUT
• Cost Effective
• Industry Standard Package
• AC or DC Control
• Panel M ount
MODEL NUMBERS
Bipolar transistor outputs are available
in 3, 5 and 7 amp ratings. Cost-effective relays offer 4000 Volt isolation and
come in Crydom's standard panelmount package.
Manufactured in Crydom's ISO 9001
Certified facility for optimum product
performance and reliability.
DC CONTROL
A C CONTROL
DC60S3
DC60S5
DC60S7
DC60SA3
DC60SA5
DC60SA7
Operating Voltage Range [Vdc]
3-60
3-60
3-60
3-60
3-60
3-60
Load Current Range➁ [Adc]
.02-3
.02-5
.02-7
.02-3
.02-5
.02-7
6
10
14
6
10
14
Max. On-State Voltage Drop @ Rated Current [Vdc]
1.3
1.5
1.7
1.3
1.5
1.7
Thermal Resistance Junction to Case (R¯JC ) [ûC/W]
2.2
2.2
2.2
2.2
2.2
2.2
Max. Off-State Leakage Current @ Rated Voltage [mA]
0.1
0.1
0.1
0.1
0.1
0.1
Max. Turn-On Time [msec]
0.1
0.1
0.1
10
10
10
Max. Turn-Off Time [msec]
0.3
0.3
0.3
40
40
40
OUTPUT SPECIFICATIONS ➀
Max. Surge Current, (1 sec) [Adc]
INPUT SPECIFICATIONS ➀
DC CONTROL
AC CONTROL
Control Voltage Range
3.5-32 Vdc
90-280 Vrms
Max. Turn-On Voltage
3.5 Vdc
90 Vrms
Min. Turn-Off Voltage
1.0 Vdc
10 Vrms
1500 Ohms
60K Ohms
2.2mA @ 5 Vdc
2mA @ 120 Vrms, 4mA @ 240 Vrms
Nominal Input Impedence
Typical Input Current
GENERAL NOTES
➀
➁
©2003 CRYDOM CORP, Specifications subject to change without notice.
All parameters at 25˚C unless otherwise specified.
Heat sinking required, for derating curves see page 2.
FastFax Document No. 163
SERIES DC60.
Rev. 111203
PAGE 1 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series DC60
3-7Amp • 60 Vdc - DC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz (input/output/base)
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
8 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-30 to 80˚C
Ambient Storage Temperature Range
-30 to 125˚C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
4
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
Input and output polarity must be observed.
Inductive loads must be diode suppressed.
8-32 TERMINAL
(2 PLACES )
All dimensions are in inches
(millimeters)
1 (+)
INPUT
LOAD
OUTPUT
AC CONTROL M ODELS
PIN 3: AC CONTROL
PIN 4: AC CONTROL
DC CONTROL M ODELS
PIN 3 : + DC CONTROL
PIN 4: -- DC CONTROL
Screws and Saddle Clamps Furnished, Unmounted
SSR
3
+
1.87
(47.5)
(+)
(Ð)
2 (--)
--
OUTPUT
1
2
4
3
--
2.30
(58.4)
1.70
(43.2)
Screw Torque Requirements :
6-32 Screws - 10 in. lbs.,
8-32 and 10-32 Screws - 20in. lbs.
(Screws dry without grease.)
+
INPUT
Transient Protection
All loads are inductive, even ones that are not so labeled. An
inductive load will produce harmful transient voltages when it
is turned off. Diodes should be fast recovery type with PIV rated
greater than supply voltage.
1.00
(25.4)
1.80
(45.7)
6-32 TERMINAL
(2 PLACES)
CURRENT DERATING CURVES
3A
5A
12
105
NO HEAT SINK
110
115
4
Power Dissipation
7.5˚C/W
8
2˚C/W
Base Plate Temp [˚C]
Power Dissipation
100
7.5˚C/W
5˚C/W
100
105
8
NO HEAT SINK
110
115
4
120
Base Plate Temp [˚C]
12
.78
(19.8)
.90
(22.9)
120
0
0
1
1.5
2
Load Current [Arms]
2.5
3
20
40
60
80
100
1
Max Ambient Temp. [˚C]
2
3
4
5
Load Current [Arms]
20
40
60
80
100
Max Ambient Temp. [˚C]
7A
7.5˚C/W
5˚C/W
100
105
8
NO HEAT SINK
110
115
4
Base Plate Temp [˚C]
2˚C/W
Power Dissipation
Crydom Heat Sinks offer excellent
thermal management and are perfectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom's Heat Sink
specification sheet for all the details.
12
120
0
1
2
3
4
5
Load Current [Arms]
6
7
20
40
60
80
100
Max Ambient Temp. [˚C]
©2003 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No. 163
SERIES DC60.
Rev. 111203
PAGE 2 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series DSD, DLD
Time Delay Relay • 10-50 Amp
• DC Control, AC Output
• External Adjustment
• Industry Standard Package
• Zero Voltage Turn-On
• Panel Mount
MODEL NUMBERS
These “on-operate” (pull-in) time-delay
solid state relays are housed in a single
industry standard package. AC output
is controlled by a DC input and has an
externally adjustable time delay.
Choices include models with two timedelay ranges.
Manufactured in Crydom''s ISO 9001
Certified facility for optimum product
performance and reliability.
DSD2410
DSD2425
DSD2450
DLD2410
DLD2425
DLD2450
48-280
48-280
48-280
48-280
48-280
48-280
.04-10
.04-25
.04-50
.04-10
.04-25
.04-50
Transient Overvoltage [Vpk]
600
600
600
600
600
600
Max. Surge Current, (16.6ms) [Apk]
120
250
625
120
250
625
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
1.6
1.6
OUTPUT SPECIFICATIONS➀
Operating Voltage Range (47-63 Hz) [Vrms]
➂ [Arms]
Load Current Range
Thermal Resistance Junction to Case [R θJC]
1.48
1.02
0.63
1.48
1.02
0.63
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
60
260
1620
60
260
1620
Max. Off-State Leakage Current @ Rated Voltage [mArms]
10
10
10
10
10
10
500
500
500
500
500
500
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Max. Turn-On Time
➁
➃
Adjustable, See Table
Max. Turn-Off Time
Max. Reset Time [µsec]
➄
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
100
100
100
100
100
100
0.5
0.5
0.5
0.5
0.5
0.5
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
Control Voltage Range
3.5-15Vdc
Max. Turn-On Voltage
3.5 Vdc
Min. Turn-Off Voltage
1.0 Vdc
Min. Input Impedance
1500 Ohms
Typical Input Current
TYPICAL TURN-ON DELAY ➀
DC CONTROL
3.4mA @ 5 Vdc, 11.4mA @ 15Vdc
RESISTOR
O (Short)
10K Ω
100KΩ
470KΩ
1.0MΩ
➃
TIME (DSD)
TIME (DLD)
0.10 sec
0.19 sec
0.94 sec
4.0 sec
8.3 sec
1.6 sec
3.1 sec
15 sec
64 sec
133 sec
© 2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25˚C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ Timing Resistor may be as high as 10M Ohm with performance dependent on resistor quality.
➄ Before and after time-out.
FastFax Document No. 201
DSD,DLD.
Rev.111203
PAGE 1 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series DSD, DLD
Time Delay Relay • 10-50 Amp
GENERAL SPECIFICATIONS
Dielectric Strength, Input section/output/base
4000 Vrms
1010
Insulation Resistance @ 500Vdc
Ambient Operating Temperature Range
-30 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (43g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
Screws and Saddle Clamps Furnished, Unmounted
WIRING DIAGRAM
1.10
(27.9)
.45
(11.4)
~
1
OUTPUT
8-32 TERMINAL
(2 PLACES )
2
2.30
(58.4)
1.70
(43.2)
1.87
(47.5)
4A 4B
3B 3A
INPUT
--
Timing
Resistor
.250
(6.35)
1.00
(25.4)
1.80
(45.7)
+
DC CONTROL
.78
(19.8)
.87
(22.2)
FASTON
TERMINAL
.187 X .032
4 PLCS.
All dimensions are in inches (millimeters)
CURRENT DERATING CURVES
25A
3°C/W
120
100
3°C/W 2°C/W
20
15
110
10
NO HEATSINK
5
2
4
6
8
Load Current [Arms]
10
20
40
60
80
Max Ambient Temp. [°C]
1°C/W .5°C/W
40
5
10
15
20
Load Current [Arms]
25
20
40
60
80
Max Ambient Temp. [°C]
100
2°C/W
110
20
120
0
90
1.5°C/W
Power Dissipation
NO HEATSINK
0
60
Base Plate Temp [°C]
115
25
Power Dissipation
Power Dissipation
8
4
95
1°C/W
5°C/W 110
Base Plate Temp [°C]
7°C/W
9°C/W
50A
30
Base Plate Temp [°C]
10A
12
120
NO HEATSINK
0
10
20
30
40
Load Current [Arms]
50
20
40
60
80
Max Ambient Temp. [°C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
APPROVALS
UL E116949
FastFax Document No. 201
DSD,DLD.
Rev.111203
PAGE 2 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series CS
10-90Amp • 120/240 Vac • AC OUTPUT
• Low Leakage
• SCR Output
• Panel Mount
• Zero and Random
Voltage Switching
• Internal Overvoltage
Protection Available
MODEL NUMBERS
The Series CS has an SCR AC switch
output featuring low off-state leakage
(1mA, snubberless), zero and random
voltage switching and a broadened
operating range (24-280Vac).
This wide range permits optimum
performance at both120Vac and
240Vac line voltages.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
CSD2410
CSE2410
CSD2425
CSE2425
CSD2450
CSE2450
CSD2475
CSE2475
CSD2490
CSE2490
24-280
24-280
24-280
24-280
24-280
0.15-10
0.15-25
0.15-50
0.25-75
0.25-90
Transient Overvoltage [Vpk]
600
600
600
600
600
Max. Surge Current, (16.6ms) [Apk]
120
250
625
1000
1200
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
1.6
Thermal Resistance Junction to Case (RθJC ) [˚C/W]
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms]
➂ [Arms]
Load Current Range
1.48
1.02
0.63
0.31
0.28
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
60
260
1620
4150
6000
Max. Off-State Leakage Current @ Rated Voltage [mA]
1.0
1.0
1.0
1.0
1.0
➁
500
500
500
500
500
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
0.5
0.5
0.5
0.5
0.5
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Max. Turn-On Time
➃
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS➀
DC CONTROL
DC CONTROL
(CSD PREFIX)
(CSE PREFIX)
Control Voltage Range
3.5-15 Vdc
15-32 Vdc
Max. Turn-On Voltage
3.5 Vdc
15.0 Vdc
Min. Turn-Off Voltage
1.0 Vdc
1.0 Vdc
300 Ohm
2k Ohm
15 mA @ 5 Vdc
7mA @ 15 V
Nominal Input Impedence
Typical Input Current
© 2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25ºC unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ Turn-on time for random turn-on version (-10 suffix) is 0.1ms
FastFax Document No.162
SERIES CS.
Rev. 111103
PAGE 1 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Series CS
10-90Amp • 120/240 Vac - AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz , Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
10 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Terminals:
Thermally Conductive Epoxy
Screws and Saddle Clamps Furnished, Unmounted
AVAILABLE OPTIONS
F
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
Faston Terminals (Up to 50A Models)
Example: CSD2425F
1
OUTPUT
8-32 TERMINAL
(2 PLACES )
2
1.87
(47.5)
G
--
Input Status LED.
Example: CSD2425G
Note: Control Voltage Range 5-15Vdc
for CSD Models.
4
Internal Overvoltage Protection.
Relay Will Self Trigger Between
450-600 Vpk. Not Suitable For Capacitive Loads.
Example: CSD2425P
-10
Phase Controllable
Example: CSD2425-10
1
Fastons:
Single pair (up to 25A)
Double pair* (up to 50A).
* Caution: User must connect to both pairs
Crydom Heat Sinks offer excellent
thermal management and are perfectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom’s Heat Sink
specification sheet for all the details.
APPROVALS
UL
E116949
CSA LR81689
VDE 10143 UG
FastFax Document No.162
SERIES CS.
Rev. 111103
PAGE 2 OF 3
6-32 TERMINAL
(2 PLACES)
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
Screw Torque Requirements:
6-32 Screws - 10 in./lbs.,
8-32 and 10-32 Screws - 20in./lbs.
(Screws dry without grease.)
3
1.00
(25.4)
1.80
(45.7)
BASE PLATE
.125 (3.2)
P
+
INPUT
OUTPUT
-4
2
+
INPUT
1.00
(25.4)
1.80
(45.7)
.78
(19.8)
.90
(22.9)
FASTON TERMINAL
.250 X .032 (2 PLCS.)
.87 REF.
(22.2)
1.87
(47.5)
BASE PLATE
.125 (3.2)
2.30
(58.4)
1.70
(43.2)
2.30
(58.4)
1.70
(43.2)
3
FASTON
TERMINAL
.187 X .032
(2 PLCS.)
.78
(19.8)
.90
(22.9)
All dimensions are in inches (millimeters)
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Series CS
10-90Amp • 120/240 Vac - AC OUTPUT
CURRENT DERATING CURVES
10A
25A
12
30
4
120
100
3˚C/W
2˚C/W
20
15
110
10
NO HEATSINK
5
0
6
8
10
50A
40
60
80
5
80
20
40
60
80
60
80
90
1˚C/W
110
40
.2˚C/W
.4˚C/W
Power Dissipation
100
Base Plate Temp [˚C]
.3˚C/W
.5˚C/W
80
100
1ºC/W
110
40
120
120
0
Max Ambient Temp. [˚C]
40
90A
120
NO HEATSINK
0
50
20
Max Ambient Temp. [˚C]
120
95
Power Dissipation
110
20
40
25
.5˚C/W
Base Plate Temp [˚C]
100
2˚C/W
30
20
90
40
20
15
75A
.5˚C/W
1.5˚C/W
Load Current [Arms]
10
Load Current [Arms]
120
1˚C/W
Power Dissipation
Power Dissipation
20
Max Ambient Temp. [˚C]
0
15
30
45
60
Load Current [Arms]
75
20
40
60
80
Max Ambient Temp. [˚C]
20
40
60
80
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No.162
SERIES CS.
Rev. 111103
PAGE 3 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Base Plate Temp [˚C]
4
Load Current [Arms]
10
120
0
2
60
Base Plate Temp [˚C]
115
NO HEATSINK
25
Power Dissipation
8
Base Plate Temp [˚C]
1˚C/W
110
5˚C/W
Power Dissipation
95
3˚C/W
7˚C/W
9˚C/W
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series CMD/CMA24
25-125Amp • 240 Vac - AC OUTPUT
• Zero Voltage and Random
Turn-On Switching
• Panel Mount
• Status Indicating LED
• DC or AC Control
• Integrated Overvoltage
Protection by Automatic
Self Turn-On (Suffix P)
MODEL NUMBERS
Featuring state-of-the-art Surface
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications. Output
consists of an SCR AC switch and is
available in zero-cross or random
turn-on versions.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
CMD2425
CMA2425
CMD2450
CMA2450
CMD2475
CMA2475
CMD2490
CMA2490
24-280
24-280
24-280
24-280
24-280
24-280
25
50
75
90
110
125
Min. Load Current, [Arms]
0.15
0.15
0.25
0.25
0.25
0.25
Transient Overvoltage [Vpk]
600
600
600
600
600
600
Max. Surge Current, (16.6ms) [Apk]
250
625
1000
1200
1500
1750
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
1.6
1.6
Thermal Resistance Junction to Case (R θJC) [˚C/W]
1.02
0.63
0.31
0.28
0.25
0.22
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
260
1620
4150
6000
9340
12700
10
10
10
10
10
10
500
500
500
500
500
500
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current➂ [Arms]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Max. Turn-On Time
➁
➃
1/2 Cycle (DC Control), 10.0 msec (AC Control)
1/2 Cycle (DC Control), 40.0 msec(AC Control)
Max. Turn-Off Time
0.5
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀ DC CONTROL
Control Voltage Range
CMD24110 CMD24125
CMA24110 CMA24125
3-32 Vdc
AC CONTROL
90-140 Vrms
Max. Reverse Voltage
32 Vdc
—
Max. Turn-On Voltage
3.0 Vdc
90 Vrms
Min. Turn-Off Voltage
1.0 Vdc
10 Vrms
30.0mA ➄
—
0.5
0.5
0.5
0.5
0.5
GENERAL SPECIFICATIONS
4000 Vrms
Dielectric Strength 50/60Hz Input/Output/Base
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
8 pF
Max. Capacitance Input/Output
Max. Input Current
Typical Input Current
17mA @ 5 Vdc 15mA @ 120 Vrms
GENERAL NOTES
➀ All parameters at 25˚C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ HEAT SINKING REQUIRED, for derating curves see page 2.
➃ Turn-on time for DC control random turn-on versions is 0.02msec.
➄ Input circuitry incorporates active current limiter.
-40 to 80˚C
Ambient Operating Temperature Range
-40 to 125˚C
Ambient Storage Temperature Range
Green LED
Status Indicating Display
MECHANICAL SPECIFICATIONS
Weight: (typical)
Encapsulation:
3.0 oz. (86.5g)
Thermally Conductive Epoxy
Terminals:
Cage Type
Maximum Wire Size- Output: AWG 8 (3.8mm) Input: AWG12 (2.5mm)
Recommended Terminal Screw Torque Range:
Output: 10-15 in lb (1.1-1.7 Nm)
Input: 5-6 in lb (0.6-0.7 Nm)
© 2003 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No. 170
SERIES CMD/CMA.
Rev. 111403
PAGE 1 OF 6
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series CMD/CMA24
25-125Amp • 240 Vac - AC OUTPUT
0.75
(19.1)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
.45
(11.4)
MECHANICAL SPECIFICATIONS
TU
INP
S
All dimensions are in inches (millimeters)
U
T ST A
INPUT
2.5
(63.5)
2.4
(63.5)
3.0
(76.2)
CMRD24/CMRA24 available with
factory mounted heat sink and DIN rail
mounting clip. Specifications available
via FastFax, request document No. 171.
OUTPUT
AVAILABLE OPTIONS
-10
Random Turn-On, Phase Controllable
Example: CMD2450-10
1.75
(44.5)
E
24 Vac Input (18-36 Vac)
Example: CMA2450E
.9
(22.9)
P
Internal Overvoltage Protection
Relay Will Self Trigger Between
450-600 Vpk. Not Suitable For Capacitive Loads
Example: CMD2450P
3.0
(76.2)
1.15
(29.2)
CURRENT DERATING CURVES
25A
50A
75A
60
90
15
110
NO HEATSINK
5
40
110
20
120
15
20
25
20
40
60
80
20
90A
40
50
20
40
60
80
110
40
20
40
60
80
Max Ambient Temp. [˚C]
60
75
20
40
60
80
Max Ambient Temp. [˚C]
90
.2˚C/W
120
.5˚C/W
100
80
1˚C/W
110
40
90
.4ºC/W
120
.5˚C/W
.2˚C/W
100
80
1˚C/W
110
40
120
0
0
45
125A
120
0
Load Current [Arms]
30
Load Current [Arms]
160
.4˚C/W
Power Dissipation
100
1˚C/W
80
15
160
Base Plate Temp [˚C]
80
60
110
30
Max Ambient Temp. [˚C]
.2˚C/W
.4˚C/W
40
1˚C/W
110A
90
.5˚C/W
Power Dissipation
30
Load Current [Arms]
120
20
60
0
10
Max Ambient Temp. [˚C]
100
120
0
Power Dissipation
10
Load Current [Arms]
95
.3˚C/W
.5˚C/W
120
NO HEATSINK
0
5
100
2˚C/W
Base Plate Temp [˚C]
10
90
Base Plate Temp [˚C]
20
.5˚C/W
1.5˚C/W
Power Dissipation
100
2˚C/W
Base Plate Temp [˚C]
Power Dissipation
3˚C/W
Power Dissipation
1˚C/W
1˚C/W
25
Base Plate Temp [˚C]
95
Base Plate Temp [˚C]
30
120
0
30
60
90 120
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
30
60
90 120
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
APPROVALS
UL E116949, E116950
CSA LR81689
VDE 126921 UG (up to 90A models only)
FastFax Document No. 170
SERIES CMD/CMA.
Rev. 111403
PAGE 2 OF 6
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series CMD/CMA48
25-125Amp • 480 Vac - AC OUTPUT
• Zero Voltage and Random
Turn-On Switching
• Panel Mount
• Status Indicating LED
• DC or AC Control
• Integrated Overvoltage
Protection by Automatic
Self Turn-On (Suffix P)
MODEL NUMBERS
Featuring state-of-the-art Surface
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications. Output
consists of an SCR AC switch and is
available in zero-cross or random
turn-on versions.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
CMD4825
CMA4825
CMD4850
CMA4850
CMD4875
CMA4875
CMD4890
CMA4890
48-530
48-530
48-530
48-530
48-530
48-530
25
50
75
90
110
125
Min. Load Current, [Arms]
0.15
0.15
0.25
0.25
0.25
0.25
Transient Overvoltage [Vpk]
1200
1200
1200
1200
1200
1200
Max. Surge Current, (16.6ms) [Apk]
250
625
1000
1200
1500
1750
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.7
1.7
1.7
1.7
1.7
1.7
Thermal Resistance Junction to Case (R θJC) [˚ C/W]
1.02
0.63
0.31
0.28
0.25
0.22
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
260
1620
4150
6000
9340
12700
10
10
10
10
10
10
500
500
500
500
500
500
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current
➂ [Arms]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Max. Turn-On Time
➁
➃
1/2 Cycle (DC Control), 10.0 msec (AC Control)
1/2 Cycle (DC Control), 40.0 msec(AC Control)
Max. Turn-Off Time
0.5
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀ DC CONTROL AC CONTROL
Control Voltage Range
4-32 Vdc
90-140 Vrms
Max. Reverse Voltage
32 Vdc
—
Max. Turn-On Voltage
4.0 Vdc
90 Vrms
Min. Turn-Off Voltage
1.0 Vdc
10 Vrms
30.0mA ➄
—
Max. Input Current
Typical Input Current
CMD48110 CMD48125
CMA48110 CMA48125
14mA @ 5 Vdc 15mA @ 120 Vrms
GENERAL NOTES
➀ All parameters at 25˚ C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ HEAT SINKING REQUIRED, for derating curves see page 2.
➃ Turn-on time for DC control random turn-on versions is 0.02msec.
➄ Input circuitry incorporates active current limiter.
0.5
0.5
0.5
0.5
0.5
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
8 pF
Max. Capacitance Input/Output
-40 to 80˚C
Ambient Operating Temperature Range
-40 to 125˚C
Ambient Storage Temperature Range
Green LED
Status Indicating Display
MECHANICAL SPECIFICATIONS
3.0 oz. (86.5g)
Weight: (typical)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
Cage Type
Maximum Wire Size- Output: AWG 8 (3.8mm) Input: AWG12 (2.5mm)
Recommended Terminal Screw Torque Range:
Output: 10-15 in lb (1.1-1.7 Nm)
Input: 5-6 in lb (0.6-0.7 Nm)
© 2003 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No. 170
SERIES CMD/CMA.
Rev. 111403
PAGE 3 OF 6
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series CMD/CMA48
25-125Amp • 480 Vac - AC OUTPUT
0.75
(19.1)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
.45
(11.4)
MECHANICAL SPECIFICATIONS
TU
INP
S
All dimensions are in inches (millimeters)
U
T ST A
INPUT
2.5
(63.5)
2.4
(63.5)
3.0
(76.2)
CMRD48/CMRA48 available with
factory mounted heat sink and DIN rail
mounting clip. Specifications available
via FastFax, request document No. 171.
OUTPUT
AVAILABLE OPTIONS
-10
Random Turn-On, Phase Controllable
Example: CMD4850-10
1.75
(44.5)
E
24 Vac Input (18-36 Vac)
Example: CMA4850E
.9
(22.9)
P
Internal Overvoltage Protection.
Relay Will Self Trigger Between
900-1200Vpk. Not suitable For Capacitive Loads.
Example: CMD4850P
3.0
(76.2)
1.15
(29.2)
CURRENT DERATING CURVES
25A
50A
75A
60
90
20
15
110
10
NO HEATSINK
5
40
110
20
20
25
20
40
60
80
10
Max Ambient Temp. [˚C]
20
90A
40
50
20
40
60
80
110
40
20
40
60
80
Max Ambient Temp. [˚C]
APPROVALS
UL E116949, E116950
CSA LR81689
VDE 126921 UG (up to 90A models only)
FastFax Document No. 170
SERIES CMD/CMA.
Rev. 111403
PAGE 4 OF 6
60
75
20
40
60
80
Max Ambient Temp. [˚C]
90
.2˚C/W
120
.5˚C/W
100
80
1˚C/W
110
40
90
.4˚C/W
120
.5˚C/W
.2˚C/W
100
80
1˚C/W
110
40
120
0
0
45
125A
120
0
80
30
Load Current [Arms]
160
.4˚C/W
Power Dissipation
100
1˚C/W
60
15
160
Base Plate Temp [˚C]
80
40
110
30
Max Ambient Temp. [˚C]
.2˚C/W
.4˚C/W
Load Current [Arms]
1˚C/W
110A
90
.5˚C/W
Power Dissipation
30
Load Current [Arms]
120
20
60
0
Power Dissipation
15
100
120
0
Base Plate Temp [˚C]
10
95
.3˚C/W
.5˚C/W
120
NO HEATSINK
0
Load Current [Arms]
100
2˚C/W
120
5
90
Base Plate Temp [˚C]
2˚C/W
.5˚C/W
1.5˚C/W
Power Dissipation
3˚C/W
Base Plate Temp [˚C]
Power Dissipation
100
Power Dissipation
1˚C/W
1˚C/W
25
Base Plate Temp [˚C]
95
Base Plate Temp [˚C]
30
120
0
30
60
90 120
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
30
60
90 120
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series CMD/CMA60
25-125Amp • 600Vac - AC OUTPUT
• DC or AC Control
Featuring state-of-the-art Surface
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications. Output
consists of an SCR AC switch and is
available in zero-cross or random
turn-on versions.
• Integrated Overvoltage
Protection by Automatic
Self Turn-On (Suffix P)
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
• Zero Voltage and Random
Turn-On Switching
• Panel Mount
• Status Indicating LED
MODEL NUMBERS
CMD6025
CMA6025
OUTPUT SPECIFICATIONS ➀
CMD6050
CMA6050
CMD6075
CMA6075
CMD6090
CMA6090
CMD60110 CMD60125
CMA60110 CMA60125
600
600
600
600
600
600
48-660
48-660
48-660
48-660
48-660
48-660
25
50
75
90
110
125
Min. Load Current, [Arms]
0.15
0.15
0.25
0.25
0.25
0.25
Transient Overvoltage [Vpk]
1200
1200
1200
1200
1200
1200
Max. Surge Current, (16.6ms) [Apk]
250
625
1000
1200
1500
1750
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.7
1.7
1.7
1.7
1.7
1.7
Thermal Resistance Junction to Case (R θJC) [˚C/W]
1.02
0.63
0.31
0.28
0.25
0.22
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
260
1620
4150
6000
9340
12700
Max. Off-State Leakage Current @ Rated Voltage [mArms]
1.0
1.0
1.0
1.0
1.0
1.0
500
500
500
500
500
500
Nominal LIne Voltage ( ±10%) [Vrms]
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current
➂ [Arms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Max. Turn-On Time
➁
➃
1/2 Cycle (DC Control), 10.0 msec (AC Control)
1/2 Cycle (DC Control), 40.0 msec(AC Control)
Max. Turn-Off Time
0.5
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀ DC CONTROL AC CONTROL
Control Voltage Range
4-32 Vdc
90-140 Vrms
Max. Reverse Voltage
32 Vdc
—
Max. Turn-On Voltage
4.0 Vdc
90 Vrms
Min. Turn-Off Voltage
1.0 Vdc
10 Vrms
30.0mA ➄
—
Max. Input Current
Typical Input Current
GENERAL NOTES
14mA @ 5 Vdc 15mA @ 120 Vrms
0.5
0.5
0.5
0.5
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
8 pF
Max. Capacitance Input/Output
-40 to 80˚C
Ambient Operating Temperature Range
-40 to 125˚C
Ambient Storage Temperature Range
Green LED
Status Indicating Display
MECHANICAL SPECIFICATIONS
3.0 oz. (86.5g)
Weight: (typical)
➀ All parameters at 25˚C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ HEAT SINKING REQUIRED, for derating curves see page 2.
➃ Turn-on time for DC control random turn-on versions is 0.02msec.
➄ Input circuitry incorporates active current limiter.
0.5
Encapsulation:
Thermally Conductive Epoxy
Terminals:
Cage Type
Maximum Wire Size- Output: AWG 8 (3.8mm) Input: Awg12 (2.5mm)
Recommended Terminal Screw Torque Range:
Output: 10-15 in lb (1.1-1.7 Nm)
Input: 5-6 in lb (0.6-0.7 Nm)
© 2003 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No. 170
SERIES CMD/CMA.
Rev. 111403
PAGE 5 OF 6
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series CMD/CMA60
25-125Amp • 600Vac - AC OUTPUT
0.75
(19.1)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
.45
(11.4)
MECHANICAL DIMENSIONS
U
TU
INP
S
All dimensions are in inches (millimeters)
T ST A
INPUT
2.5
(63.5)
2.4
(63.5)
3.0
(76.2)
CMRD60/CMRA60 available with
factory mounted heat sink and DIN rail
mounting clip. Specifications available
via FastFax, request document No. 171.
OUTPUT
AVAILABLE OPTIONS
-10
Random Turn-On, Phase Controllable
Example: CMD6050-10
E
24 Vac Input (18-36 Vac)
Example: CMA6050E
P
Internal Overvoltage Protection.
Relay Will Self Trigger Between
900-1200Vpk. Not Suitable For
Capacitive Loads.
Example: CMD6050P
1.75
(44.5)
3.0
(76.2)
.9
(22.9)
1.15
(29.2)
CURRENT DERATING CURVES
25A
50A
75A
60
90
110
10
NO HEATSINK
5
40
110
20
120
20
25
20
40
60
80
10
Max Ambient Temp. [˚C]
20
90A
40
50
20
40
60
80
110
40
0
20
40
60
80
Max Ambient Temp. [˚C]
75
20
40
60
80
Max Ambient Temp. [˚C]
90
.2˚C/W
120
.5˚C/W
100
80
1˚C/W
110
40
90
.4˚C/W
120
.5˚C/W
.2˚C/W
100
80
1˚C/W
110
40
120
0
80
60
125A
120
0
45
160
.4˚C/W
Power Dissipation
100
1˚C/W
60
30
Load Current [Arms]
160
Base Plate Temp [˚C]
80
40
15
Max Ambient Temp. [˚C]
.2˚C/W
.4˚C/W
Load Current [Arms]
110
30
110A
90
.5˚C/W
Power Dissipation
30
Load Current [Arms]
120
20
1˚C/W
0
Power Dissipation
15
60
120
0
Base Plate Temp [˚C]
10
Load Current [Arms]
100
120
NO HEATSINK
0
5
100
2˚C/W
.3˚C/W
.5˚C/W
Base Plate Temp [˚C]
15
95
Power Dissipation
20
90
1.5˚C/W
Power Dissipation
2˚C/W
Base Plate Temp [˚C]
Power Dissipation
100
3˚C/W
.5˚C/W
1˚C/W
1˚C/W
25
Base Plate Temp [˚C]
95
Base Plate Temp [˚C]
30
120
0
30
60
90 120
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
30
60
90 120
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
APPROVALS
UL E116949, E116950
CSA LR81689
VDE 126921 UG (up to 90A models only)
FastFax Document No. 170
SERIES CMD/CMA.
Rev. 111403
PAGE 6 OF 6
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series CSW
10-90Amp • 120/240 Vac • AC OUTPUT
• Low Leakage
The Series CS has an SCR AC switch
output featuring low off-state leakage
(1mA, snubberless), zero-voltage
switching and a broadened operating
range (24-280Vac). This wide range
permits optimum performance at both
120Vac and 240Vac line voltages.
• SCR Output
• Panel Mount
• Zero Voltage Switching
• Wide Control Range
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
MODEL NUMBERS
CSW2410
CSW2425
CSW2450
CSW2475
CSW2490
24-280
24-280
24-280
24-280
24-280
0.15-10
0.15-25
0.15-50
0.25-75
0.25-90
Transient Overvoltage [Vpk]
600
600
600
600
600
Max. Surge Current, (16.6ms) [Apk]
120
250
625
1000
1200
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
1.6
Thermal Resistance Junction to Case (RθJC ) [˚C/W]
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms]
Load Current Range
➂ [Arms]
1.48
1.02
0.63
0.31
0.28
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
60
260
1620
4150
6000
Max. Off-State Leakage Current @ Rated Voltage [mA]
1.0
1.0
1.0
1.0
1.0
➁
500
500
500
500
500
Max. Turn-On Time
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
Max. Turn-Off Time
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
0.5
0.5
0.5
0.5
0.5
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS
➀
DC CONTROL
Control Voltage Range
3-32 Vdc
Max. Turn-On Voltage
3 Vdc
Min. Turn-Off Voltage
1.0 Vdc
See note 4
Nominal Input Impedence
10mA @ 12 Vdc
Typical Input Current
© 2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➁ All parameters at 25ºC unless otherwise specified.
➂ Heat sinking required, for derating curves see page 2.
➃ Input Circuit Incorporates Active Current Limiter.
SERIES CSW.
Rev. 111803
PAGE 1 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series CSW
10-90Amp • 120/240 Vac • AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz , Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
10 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
MECHANICAL SPECIFICATIONS
Weight: (typical)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
Screws and Saddle Clamps Furnished, Unmounted
AVAILABLE OPTIONS
F
Faston Terminals (Up to 50A Models)
Example: CSW2425F
G
Input Status LED.
Example: CSW2425G
P
Phase Controllable
Example: CSW2425-10
H
Heat Transfer Pad (Attached)
Example: CSW2425H
1
--
2
+
INPUT
6-32 TERMINAL
(2 PLACES)
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1
OUTPUT
-4
2
+
INPUT
1.00
(25.4)
1.80
(45.7)
.78
(19.8)
.90
(22.9)
FASTON TERMINAL
.250 X .032 (2 PLCS.)
.87 REF.
(22.2)
1.87
(47.5)
BASE PLATE
.125 (3.2)
2.30
(58.4)
1.70
(43.2)
3
1.00
(25.4)
1.80
(45.7)
BASE PLATE
.125 (3.2)
Fastons:
Single pair (up to 25A)
Double pair* (up to 50A).
* Caution: User must connect to both pairs
EN61000-4-2, Level 3 ESD
EN61000-4-4, Level 3 Burst
Output: EN61000-4-2, Level 3 ESD
Level 4 ESD (with P option)
EN61000-4-4, Level 3 Burst
Level 4 Burst (with P option)
EN61000-4-5, Level 4 Surge
SERIES CSW.
Rev. 111803
PAGE 2 OF 3
4
Screw Torque Requirements:
6-32 Screws - 10 in./lbs.,
8-32 and 10-32 Screws - 20in./lbs.
(Screws dry without grease.)
EMC Compatibility
APPROVALS
UL
Pending
CSA Pending
VDE Pending
OUTPUT
8-32 TERMINAL
(2 PLACES )
1.87
(47.5)
Crydom Heat Sinks offer excellent
thermal management and are perfectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom’s Heat Sink
specification sheet for all the details.
Input:
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
Internal Overvoltage Protection.
Relay Will Self Trigger Between
450-600 Vpk. Not Suitable For Capacitive Loads.
Example: CSW2425P
-10
3.0 oz. (86.5g)
2.30
(58.4)
1.70
(43.2)
3
FASTON
TERMINAL
.187 X .032
(2 PLCS.)
.78
(19.8)
.90
(22.9)
All dimensions are in inches (millimeters)
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series CSW
10-90Amp • 120/240 Vac • AC OUTPUT
CURRENT DERATING CURVES
10A
25A
12
30
4
120
100
3˚C/W
2˚C/W
20
15
110
10
NO HEATSINK
5
0
6
8
10
50A
40
60
80
5
.5˚C/W
80
20
40
60
80
60
80
90
1˚C/W
110
40
.2˚C/W
.4˚C/W
Power Dissipation
100
Base Plate Temp [˚C]
.3˚C/W
.5˚C/W
80
100
1ºC/W
110
40
120
120
0
Max Ambient Temp. [˚C]
40
90A
120
NO HEATSINK
0
50
20
Max Ambient Temp. [˚C]
120
95
Power Dissipation
110
20
40
25
.5˚C/W
Base Plate Temp [˚C]
100
2˚C/W
30
20
90
40
20
15
75A
1.5˚C/W
Load Current [Arms]
10
Load Current [Arms]
120
1˚C/W
Power Dissipation
20
Max Ambient Temp. [˚C]
0
15
30
45
60
Load Current [Arms]
75
20
40
60
80
Max Ambient Temp. [˚C]
20
40
60
80
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
SERIES CSW.
Rev. 111803
PAGE 3 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Base Plate Temp [˚C]
4
Load Current [Arms]
10
120
0
2
60
Base Plate Temp [˚C]
115
NO HEATSINK
25
Power Dissipation
8
Base Plate Temp [˚C]
1˚C/W
110
5˚C/W
Power Dissipation
95
3˚C/W
7˚C/W
9˚C/W
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
CW 24
10-125Amp - 120/240 Vac - AC OUTPUT
•
•
•
•
•
•
•
•
•
600V Blocking
Low Leakage
SCR Output
Zero and Random
Voltage Switching
LED Status Indicator
Panel Mount
Intergrated Removable
Fingerproof Cover
User Friendly, Universal
Connectors
EMC Compliant Design
Crydom's CW24 line of solid state relays offer
an SCR AC switch output featuring low offstate leakage (1mA, snubberless), zero and
random voltage switching and a broadened
operating range (24-280Vac). This wide
range permits optimum perfomance at both
120Vac and 240Vac line voltages.
Manufactured in Crydom's ISO 9001
Certified facility for optimum product
performance and reliability.
CWD2410
CWA2410
CWD2425
CWA2425
CWD2450
CWA2450
CWD2490
CWA2490
CWD24125
CWA24125
24-280
24-280
24-280
24-280
24-280
0.15-10
0.15-25
0.15-50
0.25-90
0.25-125
Transient Overvoltage [Vpk]
600
600
600
600
600
Max. Surge Current, (16.6ms) [Apk]
400
600
850
1350
2000
Max. Surge Current (20ms) [Apk]
380
570
810
1290
1900
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.3
1.3
1.3
1.3
1.25
Thermal Resistance Junction to Case (RθJC ) [˚C/W]
0.35
0.35
0.2
0.14
0.13
Maximum I 2 t for Fusing, (8.3 ms) [A 2s]
660
1500
3000
7560
16600
Maximum I 2 t for Fusing, (10ms) [A 2 s]
720
1620
3280
8320
18000
Max. Off-State Leakage Current @ Rated Voltage [mA] ➅
1.0
1.0
1.0
1.0
1.0
500
500
500
500
500
Max. Turn-On Time ➃ ➄
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
Max. Turn-Off Time ➄
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
0.5
0.5
0.5
0.5
0.5
MODEL NUMBERS
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms]
Load Current Range
➂
[Arms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µs]
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
➁
DC Control
AC Control
24 Vac nominal
E - suffix
Control Voltage Range
3-32 Vdc
18-36 Vrms
90-280 Vrms
Max. Turn-On Voltage
3 Vdc
18 Vrms
90 Vrms
Min. Turn-Off Voltage
1.0 Vdc
2 Vrms
10 Vrms
See note 7
1 k ohm
Nominal Input Impedence
Typical Input Current
10 mA @ 12 Vdc
GENERAL NOTES
➀ All parameters at 25˚C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ Turn-on time for random turn-on version is 0.02 msec.
➄ Turn-on and turn-off time for AC input models is 50ms.
➅ 10mA for models with snubber.
➆ Input circuit incorporates active current limiter.
SERIES CW24
Rev. 081403
PAGE 1 OF 3
24mA@24Vrms
AC Control
120/240Vac nominal
Std. (no suffix)
21.5 k ohms
6 mA @ 120 Vrms
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
8 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation
Thermally Conductive Epoxy
Terminals
Screw Type, Finger Proof
Output: 8-32, Combo Drive
Input: 6-32, Combo Drive
Max. Torque
Output: 20 in lb (2.2Nm)
Input: 10 in lb (1.1Nm)
Output: 2 x AWG 8 (3.8mm)
Input: 2 x AWG 12 (2.5mm)
Max. Wire Size
Available Options
-10
MECHANICAL OUTLINE
Random Turn-On.
Example: CWD2425-10
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
E
24 Vac Input (18-36 Vac)
Example: CWA2425E
P
Internal Overvoltage Protection.
Relay Will Self Trigger Between
450-600 Vpk. Not Suitable For Capacitive Loads.
Example: CWD2425P
Internal Snubber Example: CWD2425S
S
H
Heat Transfer Pad (Attached)
Example: CWD2425H
2.30
(58.4)
2/T1
1.87
(47.5)
1.70
(43.2)
+3/A1
4/A2
INPUT
1.00
(25.4)
1.30
(33.0)
All dimensions are in inches (millimeters)
EN61000-4-2, Level 3 ESD
EN61000-4-4, Level 3 Burst
EN61000-4-2, Level 3 ESD
Level 4 ESD (with P option)
EN61000-4-4, Level 3 Burst
Level 4 Burst (with P option)
EN61000-4-5, Level 4 Surge
APPROVALS
UL
E116949
CSA 1405925
VDE 40007242
SERIES CW24
Rev. 081403
PAGE 2 OF 3
OUTPUT
1.80
(45.7)
EMC Compatibility
Output:
OUTPUT
1/L1
BASE PLATE
.125 (3.2)
Crydom Heat Sinks offer excellent thermal management and are perfectly
matched to the load current ratings of
Crydom panel mount relays. Request
Crydom's Heat Sink specification sheet
for all the details.
Input:
1.10
(27.9)
.45
(11.4)
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
CW 24
10-125Amp - 120/240 Vac - AC OUTPUT
CURRENT DERATING CURVES
20
3˚C/W
15
120
10
5
2
0
2
4
6
8
10
Load Current [Arms]
20
40
60
120
80
50
.1˚C/W
2˚C/W
123
40
1.5˚C/W
115
117
30
119
20
121
10
123
0
0
5
Max Ambient Temp. [˚C]
10
15
20
25
Load Current [Arms]
20
40
60
10
80
20
30
40
Load Current [Arms]
Max Ambient Temp. [˚C]
50
20
40
60
80
Max Ambient Temp. [˚C]
125A
90A
130
120
80
.5˚C/W
115
1˚C/W
60
118
40
121
20
.4˚C/W
100
Power Dissipation
112
Base Plate Temp [˚C]
.4˚C/W
100
Power Dissipation
116
109
112
.5˚C/W
115
80
1˚C/W
60
117
40
120
20
122
124
0
0
20
40
60
80
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
30
60
90 120
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
SERIES CW24
Rev. 081403
PAGE 3 OF 3
Base Plate Temp [˚C]
123
4
2˚C/W
4˚C/W
Base Plate Temp [˚C]
6
25
Power Dissipation
8
7˚C/W
Power Dissipation
121
9˚C/W
Base Plate Temp [˚C]
10
Power Dissipation
50A
25A
Base Plate Temp [˚C]
10A
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
CW 48
10-125Amp - 600Vac - AC OUTPUT
•
•
•
•
1200V Blocking
Low Leakage
SCR Output
Zero and Random
Voltage Switching
LED Status Indicator
Panel Mount
Intergrated Removable
Fingerproof Cover
User Friendly, Universal
Connectors
EMC Compliant Design
•
•
•
•
•
The Series CW48 has an SCR AC switch
output featuring low off-state leakage
(1mA, snubberless), zero and random
voltage switching and a broadened
operating range (48-660Vac).
This wide range permits optimum
perfomance at voltages from 240 Vac to
600 Vac line voltages.
Manufactured in Crydom's ISO 9001
Certified facility for optimum product
performance and reliability.
CWD4810
CWA4810
CWD4825
CWA4825
CWD4850
CWA4850
CWD4890
CWA4890
48-660
48-660
48-660
48-660
48-660
0.15-10
0.15-25
0.15-50
0.25-90
0.25-125
1200
1200
1200
1200
1200
Max. Surge Current (16.6ms) [Apk]
400
600
850
1350
2000
MODEL NUMBERS
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms] ➇
Load Current Range
➂
[Arms]
Transient Overvoltage [Vpk]
CWD48125
CWA48125
Max. Surge Current (20ms) [Apk]
380
570
810
1290
1900
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.3
1.3
1.3
1.3
1.25
Thermal Resistance Junction to Case (RθJC ) [˚C/W]
0.35
0.35
0.2
0.14
0.13
Maximum I 2 t for Fusing, (8.3 ms) [A 2s]
660
1500
3000
7560
16600
Maximum I 2 t for Fusing, (10 ms) [A 2s]
720
1620
3280
8320
18000
Max. Off-State Leakage Current @ Rated Voltage [mA] ➅
1.0
1.0
1.0
1.0
1.0
500
500
500
500
500
Max. Turn-On Time ➃ ➄
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
Max. Turn-Off Time ➄
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
1/2 Cycle
0.5
0.5
0.5
0.5
0.5
Min. Off-State dv/dt @ Max. Rated Voltage [V/µs]
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
➁
DC Control
AC Control
24 Vac nominal
E - suffix
Control Voltage Range
4-32 Vdc
18-36 Vrms
90-280 Vrms
Max. Turn-On Voltage
4 Vdc
18 Vrms
90 Vrms
Min. Turn-Off Voltage
1.0 Vdc
2 Vrms
10 Vrms
See note 7
1 k ohm
Nominal Input Impedence
Typical Input Current
10 mA @ 12 Vdc
GENERAL NOTES
➀ All parameters at 25˚C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ Turn-on time for random turn-on version is 0.02 msec.
➄ Turn-on and turn-off time for AC input models is 50ms.
➅ 10mA for models with snubber.
➆ Input circuit incorporates active current limiter.
➇ 48-530 Vrms for models with snubber.
SERIES CW48
Rev. 081803
PAGE 1 OF 3
24mA@24Vrms
AC Control
120/240Vac nominal
Std. (no suffix)
21.5 k ohms
6 mA @ 120 Vrms
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
CW 48
10-125Amp - 600Vac - AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
8 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation
Thermally Conductive Epoxy
Terminals
Screw Type, Finger Proof
Output: 8-32, Combo Drive
Input: 6-32, Combo Drive
Max. Torque
Output: 20 in lb (2.2Nm)
Input: 10 in lb (1.1Nm)
Output: 2 x AWG 8 (3.8mm)
Input: 2 x AWG 12 (2.5mm)
Max. Wire Size
Available Options
MECHANICAL OUTLINE
-10
Random Turn-On.
Example: CWD4825-10
E
24 Vac Input (18-36 Vac)
Example: CWA4825E
P
Internal Overvoltage Protection.
Relay Will Self Trigger Between
900-1200 Vpk. Not Suitable For Capacitive Loads.
Example: CWD4825P
Internal Snubber Example: CWD4825S
S
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1.10
(27.9)
.45
(11.4)
OUTPUT
1/L1
2.30
(58.4)
2/T1
1.87
(47.5)
1.70
(43.2)
+3/A1
4/A2
INPUT
H
Heat Trasfer Pad (Attached)
Example: CWD4825H
BASE PLATE
.125 (3.2)
Crydom Heat Sinks offer excellent thermal management and are perfectly
matched to the load current ratings of
Crydom panel mount relays. Request
Crydom's Heat Sink specification sheet
for all the details.
1.00
(25.4)
1.30
(33.0)
1.80
(45.7)
EMC Compatibility
Input:
Output:
EN61000-4-2, Level 3 ESD
EN61000-4-4, Level 3 Burst
EN61000-4-2, Level 3 ESD
Level 4 ESD (with P option)
EN61000-4-4, Level 3 Burst
Level 4 Burst (with P option)
EN61000-4-5, Level 4 Surge
APPROVALS
UL
E116949
CSA 1405925
VDE 40007242
SERIES CW48
Rev. 081803
PAGE 2 OF 3
All dimensions are in inches (millimeters)
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
CW 48
10-125Amp - 600Vac - AC OUTPUT
CURRENT DERATING CURVES
4
20
3˚C/W
15
120
10
5
2
0
2
4
6
8
10
Load Current [Arms]
20
40
60
120
80
5
10
15
20
Load Current [Arms]
25
20
121
10
123
40
60
10
80
20
30
40
50
Load Current [Arms]
115
1˚C/W
60
118
40
121
20
124
0
20
40
60
80
Max Ambient Temp. [˚C]
.4˚C/W
100
Power Dissipation
.5˚C/W
Base Plate Temp [˚C]
Power Dissipation
112
80
0
20
20
40
60
80
Max Ambient Temp. [˚C]
125A
.4˚C/W
80
119
130
120
100
60
1.5˚C/W
115
117
30
Max Ambient Temp. [˚C]
90A
40
40
0
0
Load Current [Arms]
.1˚C/W
2˚C/W
123
Max Ambient Temp. [˚C]
20
50
109
112
.5˚C/W
115
80
1˚C/W
60
117
40
120
20
122
0
30
60
90 120
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
SERIES CW48
Rev. 081803
PAGE 3 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Base Plate Temp [˚C]
123
116
2˚C/W
4˚C/W
Base Plate Temp [˚C]
6
25
Power Dissipation
8
7˚C/W
Power Dissipation
121
9˚C/W
Base Plate Temp [˚C]
10
Power Dissipation
50A
25A
Base Plate Temp [˚C]
10A
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series EZ
5-18Amp • 120/240, 480 Vac • AC OUTPUT
•
•
•
•
Low Leakage
Quick Connect Terminals
SCR Output
24V Control Available
(EZE Models)
The Series EZ SPST-NO AC output
relays offer a low profile package
with the convenience of quick con-
AC CONTROL (120Vac)
(24Vac)
MODEL NUMBERS
DC CONTROL (5Vdc)
(24Vdc)
nect terminals. The Series EZ is the
preferred choice for replacement of
120V and 240V Electro-mechanical
relays. Output consists of an SCR
switch and is available in Zero-Cross
and Random Turn-On (Phase
Controlable) versions.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
EZ240A12
EZE240A12
EZ240A18
EZE240A18
EZ480A12
EZE480A12
EZ480A18
EZE480A18
EZ240D5
EZ240D12
EZE240D12
EZ240D18
EZE240D18
EZ480D12
EZE480D12
EZ480D18
EZE480D18
24-280
24-280
24-280
48-660
48-660
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms]
5
12
18
12
18
Min. Load Current, [mArms]
150
150
150
150
150
Transient Overvoltage [Vpk]
600
600
600
1200
1200
Max. Surge Current, (16.6ms) [Apk]
40
150
200
150
200
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.5
1.5
1.5
1.5
1.5
Thermal Resistance Junction to Case (R θJC) [˚C/W]
2.0
2.0
1.1
2.0
1.1
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
95
95
170
95
170
Max. Off-State Leakage Current @
Rated Voltage [mArms] ➄
0.1
0.1
0.1
0.1
0.1
Min. Off-State dv/dt @ Max. Rated Voltage [V/ µsec] ➁
500
500
500
500
500
0.5
0.5
Max. Load Current ➃ [Arms]
Max. Turn-On Time
➅
1/2 Cycle (DC Input), 10.0 msec (AC Input)
1/2 Cycle (DC Input), 40.0 msec (AC Input)
Max. Turn-Off Time
0.5
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
Nominal Voltage
0.5
0.5
DC CONTROL
5Vdc
5Vdc
5Vdc
AC CONTROL
EZ240D5
EZ240D12
EZ240D18
EZ480D12
EZ480D18
24Vdc
EZE240D12
EZE240D18
EZE480D12
EZE480D18
Control Voltage Range
4-15 Vdc
3-15 Vdc
4-15 Vdc
15-32 Vdc
90-140 Vrms
18-36 Vrms
Max. Turn-On Voltage
4.0 Vdc
3.0 Vdc
4.0 Vdc
15.0 Vdc
90.0 Vrms
18.0 Vrms
Min. Turn-Off Voltage
1.0 Vdc
1.0 Vdc
1.0 Vdc
1.0 Vdc
10.0 Vrms
2.0 Vrms
300 Ohms
300 Ohms
240 Ohms
1500 Ohms
10.6k Ohms
1.8k Ohms
13 mAdc
15 mAdc
15 mAdc
15 mAdc
10 mArms
10 mArms
MODEL NUMBERS
Nominal Input Impedance
Typical Input Current @ Nominal Voltage
GENERAL NOTES
120Vac
EZ240A12
EZ240A18
EZ480A12
EZ480A18
24Vac
EZE240A12
EZE240A18
EZE480A12
EZE480A18
© 2003 CRYDOM CORP, Specifications subject to change without notice.
All parameters at 25˚ C unless otherwise specified.
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
240V, DC control models only, all others 2500Vrms.
Heat sinking required, for derating curves see page 2.
For recommended applications and more information contact:
Off-State leakage for snubbered
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
version (suffix S) is 10.0 mArms.
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
➅ Turn-on time for random turn-on versions
Email: sales@crydom.com WEB SITE: http://www.crydom.com
is 0.1 msec (DC Control Models).
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
FastFax Document No.160
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
SERIES EZ.
GERMANY: +49 (0)180 3000 506
Rev. 111203
PAGE 1 OF 2
➀
➁
➂
➃
➄
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series EZ
5-18Amp • 120/240, 480 Vac • AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength ➂ 50/60Hz Input/Output/Base
4000 Vrms*
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
8 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
MECHANICAL SPECIFICATIONS
Weight: (typical)
1.5 oz. (43g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
.25 Inch Faston
AVAILABLE OPTIONS
*240V, DC Control Models Only.
2.63
(66.8)
S
Internal Snubber
Example: EZ240D12S
R
Random Turn-On Switching
Example: EZ240D12R, EZ240D12RS
EZ240D5R
2.24
(56.9)
1
.197 DIA.
(2 PLCS)
2
OUTPUT
1.00
(25.4)
.49
(12.4)
3+
Crydom Heat Sinks offer excellent thermal management and are perfectly
matched to the load current ratings of
Crydom panel mount relays. Request
Crydom’s Heat Sink specification sheet for
all the details.
PIN
PIN
PIN
PIN
4
INPUT
FASTON
TERMINAL
.250 X .032
4 PLCS.
1.50
(38.1)
1:
2:
3:
4:
AC LOAD
AC LOAD
+DC CONTROL
--- DC CONTROL
.40
(10.2)
1.73
(43.9)
.12
(3.0)
.95
(24.1)
All dimensions are in inches (millimeters)
CURRENT DERATING CURVES
12A
5A
18
2
120
6˚C/W
116
NO HEATSINK
5
120
2˚C/W
12
5˚C/W
116
NO HEATSINK
6
112
120
1
124
0
1
2
3
4
5
Load Current [Arms]
10
20
40
60
80
Max Ambient Temp. [˚C]
APPROVALS
2
4
6
8
10
Load Current [Arms]
12
20
40
60
80
Max Ambient Temp. [˚C]
124
0
3
6
9
12
15
18
Load Current [Arms]
40
60
80
Max Ambient Temp. [˚C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
UL
E116950
CSA LR81689
VDE 10139 UG (240V DC Control Only)
FastFax Document No.160
SERIES EZ
Rev. 111203
PAGE 2 OF 2
20
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Base Plate Temp [˚C]
115
112
4˚C/W
10
Power Dissipation [W]
NO HEATSINK
3
Power Dissipation [W]
4
Base Plate Temp [˚C]
110
5˚C/W
Base Plate Temp [˚C]
2˚C/W
10˚C/W
5
Power Dissipation
18A
15
6
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series 2
8Amp • 120, 240 Vac - AC OUTPUT
• Zer o V oltage Switching
• 2500 V olt Isolation
• Panel M ount
• Triac Output
CURRENT DERATING CURVES
Relays combine small size and high ratings in a package designed for easy
heat sink or panel mounting. Standard
.187 push-on terminals assure quick
connection and are arranged to provide
maximum isolation between signal and
power circuits. Model S228C is a snubber- less design for applications that
require low off-state leakage.
Manufactured in Crydom's ISO 9001
Certified facility for optimum product
performance and reliability.
MODEL NUMBERS
S218
S228
S228C
Operating Voltage (47-63 Hz) [Vrms]
20-140
40-280
40-280
Max. Load Current Range [Arms]
.15-8.0
.15-8.0
.15-8.0
OUTPUT SPECIFICATIONS ➀
3.6˚C/W
2.5˚C/W
Power Dissipation [W]
1¼C/W
65
5¼C/W
8
7.5¼C/W
75
10¼C/W
85
4
95
Max Allowable Base Temp. [˚C]
12
0
2
4
6
8
Load Current [Arms]
20
40
60
80
Max Ambient Temp. [˚C]
Transient Overvoltage [Vpk]
400
600
600
Max. Surge Current, (16.6ms) [Apk]
120
120
120
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
Thermal Resistance Junction to Case (RθJC) [ûC/W]
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
1.5
1.5
1.5
60
60
60
Max. Off-State Leakage Current @ Rated Voltage [mA]
4.0
4.0
0.1
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁
200
200
200
Max. Turn-On Time
1/2 cycle
1/2 cycle
1/2 cycle
Max. Turn-Off Time
1/2 cycle
1/2 cycle
1/2 cycle
0.5
0.5
0.5
Power Factor (Min.) with Max. Load
MOUNTING HOLE
0.125 (.300) DIA.
INPUT SPECIFICATIONS ➀
3.5-8.0
OUTPUT
1.50
(38.1)
1.75
(44.4)
INPUT
+
4
200 Ohm
Nominal Input Impedence
2
1
Control Voltage Range
3
.85
(21.6)
BASE
PLATE
.06 (1.5)
.562
(14.3)
.83
(21.1)
.60
(15.2)
All dimensions are in inches (millimeters)
Max. Turn-On Voltage
3.5 Vdc
Min. Turn-Off Voltage
1.0 Vdc
Typical Input Current @ 5Vdc
18 mA
GENERAL SPECIFICATIONS
Dielectric Strength
➁
2500 Vrms
Insulation Resistance (Min.) @ 500 Vdc
➁
109 Ohm
8.0 pF
Max. Capacitance
Ambient Operating Temperature Range
-30 to 80¼C
Ambient Storage Temperature Range
-30 to 125¼C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
Encapsulation:
GENERAL NOTES
APPROVALS
UL
E116949
CSA LR81689
FastFax Document No.156
SERIES 2.
Rev. 111403
PAGE 1 OF 1
➀
➁
➂
1.3 oz. (40 g)
Thermally Conductive Epoxy
©2003 CRYDOM CORP, Specifications subject to change without notice.
All parameters at 25¼C unless otherwise specified.
Dielectric and insulation resistance are measured between input and output.
Off-State dv/dt test method per EIA/NARM standard RS-443.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Series LR
25-40Amp • 120/240/480 Vac - AC OUTPUT
• DC or AC Control
• Zero Cross and Random Switching
• Up to 1200V Transient Capability
• SCR Output
• PCB Mount
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
• Low Profile
OUTPUT SPECIFICATIONS ➀
CURRENT DERATING CURVES
25A
30
100
3˚C/W
2˚C/W
20
15
110
10
5
Base Plate Temp [˚C]
1˚C/W
Power Dissipation
Operating Voltage Range (47-63 Hz) [Vrms]
24-280
24-280
48-530
48-530
Load Current Range [Arms]
0.15-25
0.15-40
0.15-25
0.15-40
Transient Over-Voltage [Vpk]
600
600
1200
1200
250
400
250
400
Max. I t For Fusing (8.3 msec.) [A sec]
260
660
260
660
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➂
500
500
500
500
Max.Off-State Leakage @ Rated Voltage [mArms]
0.1
0.1
0.1
0.1
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
95
25
120
0
5
10
15
20
25
Load Current [Arms]
20
40
60
80
Max Ambient Temp. [˚C]
40A
Max. Surge Current Non-Repetitive, (16.6ms) [Apk]
2
2
Max.Turn-On Time
60
.5˚C/W
90
1.5˚C/W
40
100
2˚C/W
110
20
120
➃
Max. Turn-Off Time
Base Plate Temp [˚C]
1˚C/W
Power Dissipation
LR600240D25 LR600240D40 LR1200480D25 LR1200480D40
LR600240D25R LR600240D40R LR1200480D25R LR1200480D40R
Zero Cross Turn-on
Random Turn-on
MODEL NUMBERS
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
0.5
Power Factor (Min.) WIth Max. Load
INPUT SPECIFICATIONS ➀
1/2 cycle
120 Vac Control
Control Voltage Range
Must Turn On Voltage
0.5
➅
0.5
0.5
DC Control
➅
240V AC Control
90-140 Vac
4-32 Vdc
180-260 Vac
90 Vac
4 Vdc
180 Vac
10 Vac
1 Vdc
0
10
20
30
40
50
Load Current [Arms]
20
40
60
80
Max Ambient Temp. [˚C]
Must Turn Off Voltage
Typical Input Current at 5Vdc ➄ ➅
15mA@120 Vac
9 mA@ 5 Vdc
10 Vac
11mA@ 240Vac
MECHANICAL DIMENSIONS
All dimensions are in inches (millimeters)
Output
-
Input
+
GENERAL SPECIFICATIONS
Dielectric Strength ➁
1.38
(35.0)
1.0
(25.4)
AC
AC
1.12
(28.4)
.78
(19.8)
2500 Vrms
Insulation Resistance (Min.) @ 500 Vdc ➁
10 9 Ohm
Max. Capacitance
8.0 pF
Ambient Operating Temperature Range
-30 to 80˚C
Ambient Storage Temperature Range
-30 to 125˚C
MECHANICAL SPECIFICATIONS
0.5 oz. (14.4 g)
Weight: (typical)
.050 Typ.
(1.2)
.500
(12.7)
APPROVALS
UL
(Pending)
CSA (Pending)
VDE (Pending)
Series LR
Rev. 111303
PAGE 1 OF 1
.39
(9.8)
.25
(6.3)
GENERAL NOTES
➀
➁
➂
➃
➄
➅
© 2003 CRYDOM CORP, Specifications subject to change without notice.
All parameters at 25˚C unless otherwise specified.
Dielectric and insulation resistance are measured between input and output.
Off-State dv/dt test method per EIA/NARM standard RS-443.
Turn on time for random switching models is 0.1 ms (use suffix when ordering random turn on version)
DC Input circuitry incorporates active current limiter.
Use suffix -120 for 120Vac control and -240 for 240Vac control.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series SMR24-6
25-90Amp • 120/240 Vac - AC OUTPUT
condition alarms. Low line voltage,
load circuit high impedance, relay output
and loss of DC supply current are
constantly monitored by this unique
Solid State Relay (SSR).
• System Monitoring
Solid State Relay
• LED Status Indicators
• Alarm Output Signal
• Zero Voltage Switching
• Invert/Non Invert Control
Inputs and Alarm Outputs
The alarm circuit can sink or source
100mA. The sink output is Normally
Closed (NPN) and the source output is
Normally Open (PNP).
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
The SMR Series of System Monitoring
Relays offer the user a number of fault
MODEL NUMBERS
SMR2425-6
SMR2450-6
SMR2490-6
60-280
60-280
60-280
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms]
➂ [Arms]
25
50
90
Min. Load Current, [mArms]
40
40
40
Transient Overvoltage [Vpk]
600
600
600
Max. Surge Current, (16.6ms) [Apk]
250
625
1200
Max. Load Current
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
Thermal Resistance Junction to Case (R θJC) [˚C/W]
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
1.02
0.63
0.28
260
1620
6000
10
10
10
Max. Off-State Leakage Current @ Rated Voltage [mArms]
➁
500
500
500
Max. Turn-On Time
1/2 Cycle
1/2 Cycle
1/2 Cycle
Max. Turn-Off Time
1/2 Cycle
1/2 Cycle
1/2 Cycle
0.5
0.5
0.5
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Power Factor (Min.) with Max. Load
CONTROL SPECIFICATIONS ➀➃
Logic Supply Voltage Range
INVERTING
NON-INVERTING
8-32 Vdc (pin 3)
8-32 Vdc (pin 3)
8 mA
14 mA (plus pin 8 loading)
Input-On Voltage Range
8-32 Vdc (pin 6)
0-1.0 Vdc (pin 5)
Input-Off Voltage Range
0-0.4 Vdc (pin 6)
8-32 Vdc (pin 5)
6 mA (pin 6)
1.0 mA (pin 5)
Logic Supply Current @ 12 Vdc
Input-On Current @ 12 Vdc (Logic Supply)
ALARM SPECIFICATIONS ➀➃
NORMALLY CLOSED
Supply Voltage (with load)
Alarm-On Voltage
Open Col. NPN (pin 7)
Alarm-Off Voltage
Maximum Alarm Output Current
Alarm Delay (Min.-Max.)
RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ All voltages are positive in respect to common (pin 4).
SERIES SMR24-6
Rev. 111803
PAGE 1 OF 2
Supply Voltage (minus 1.0 V)
Active High PNP (pin 8)
1.5 Vdc
0.0 Vdc (with load)
Active Low NPN (pin 7)
Open Col. PNP (pin 8)
100 mA
100 mA
30-100 msec.
30-100 msec.
© 2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25˚C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard
NORMALLY OPEN
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
* Note:
*
SMR family of relays is not available for purchase in Germany
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series SMR24-6
25-90Amp • 120/240 Vac - AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
Max. Capacitance Input/Output
8 pF
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Thermally Conductive Epoxy
Encapsulation:
Screws and Saddle Clamps Furnished, Unmounted
Output Terminals:
Input Connector (locking):
Panduit No. MLSS100-6 or Equivalent
Mating Connector (supplied):
.95
(24.2)
8-32 TERMINAL
(2 PLACES )
WIRING DIAGRAM
AC
1
OUTPUT
AC
AC
2.30
.10
(2.54) (58.4)
TYP.
1.87
(47.5)
Red LED
Alarm Status
INPUT
All dimensions are in inches (millimeters)
Screw Torque Requirements:
8-32 Screws - 20in./lbs.
(Screws dry without grease.)
.025 SQUARE
TERMINALS
(6 PLACES)
95
90A
10
NO HEATSINK
2˚C/W
110
20
120
0
100
Power Dissipation
110
1.5˚C/W
40
.5˚C/W
Base Plate Temp [ºC]
15
Power Dissipation
2˚C/W
90
1˚C/W .5˚C/W
Base Plate Temp [ºC]
100
3˚C/W
20
10
15
20
Load Current [Arms]
STATUS
CHART
25
20
40
60
80
Max Ambient Temp. [ ˚C]
Normal
Relay
OFF
Normal
Relay
ON
.2˚C/W
.4˚C/W 100
80
1˚C/W
110
40
120
120
NO HEATSINK
0
0
5
90
120
60
1˚C/W
Power Dissipation
.78
(19.8)
50A
30
5
8
CURRENT DERATING CURVES
25A
Logic Supply 8-32 Vdc
Common (–)
Control Non-Inverting
Control Inverting
Alarm N/C
Alarm N/O
3
Green LED
Input Status
1.80
(45.7)
25
AC
2
Base Plate Temp [˚C]
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
Panduit No. CT100F22-6 or Equivalent
10
20
30
40
Load Current [Arms]
50
20
40
60
20
80
Relay
Fails
Shorted
Relay
Logic
Logic
Line Line Voltage Load
Circuit
Supply Supply Loss Fails to
Low
Voltage
High
Loss w/Control Turn ON
w/Control
Low
Impedance
40
60
80
Load Current [Arms]
Max Ambient Temp. [˚C]
0
20
40
60
80
Max Ambient Temp. [˚C]
Relay
Fails
Shorted
Crydom Heat Sinks offer excellent
thermal management and are per
fectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom’s Heat Sink
specification sheet for all the
details.
LINE VOLTAGE
LOAD CURRENT
CONTROL INVERTING
CONTROL NON-INVERTING
GREEN LED
LOGIC SUPPLY
RED LED & ALARM N/O
ALARM N/C
© 2003 CRYDOM CORP, Specifications subject to change without notice.
APPROVALS
UL
PENDING
CSA PENDING
VDE PENDING
SERIES SMR24-6
Rev. 111803
PAGE 2 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
* Note:
*
SMR family of relays is not available for purchase in Germany
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series SMR48-6
25-90Amp • 480 Vac • AC OUTPUT
• System Monitoring
Solid State Relay
• LED Status Indicators
• Alarm Output Signal
• Zero Voltage Switching
• Invert/Non Invert Control
Inputs and Alarm Outputs
The SMR Series of System Monitoring
Relays offer the user a number of fault
MODEL NUMBERS
condition alarms. Low line voltage,
load circuit high impedance, relay output
and loss of DC supply current are
constantly monitored by this unique
Solid State Relay (SSR).
The alarm circuit can sink or source
100mA. The sink output is Normally
Closed (NPN) and the source output is
Normally Open (PNP).
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
SMR4825-6
SMR4850-6
SMR4890-6
96-530
96-530
96-530
25
50
90
40
40
40
Transient Overvoltage [Vpk]
1200
1200
1200
Max. Surge Current, (16.6ms) [Apk]
250
625
1200
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current
➂ [Arms]
Min. Load Current, [mArms]
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
Thermal Resistance Junction to Case (R θJC) [˚C/W]
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
1.02
0.63
0.28
260
1620
6000
10
10
10
Max. Off-State Leakage Current @ Rated Voltage [mArms]
➁
500
500
500
Max. Turn-On Time
1/2 Cycle
1/2 Cycle
1/2 Cycle
Max. Turn-Off Time
1/2 Cycle
1/2 Cycle
1/2 Cycle
0.5
0.5
0.5
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
Power Factor (Min.) with Max. Load
CONTROL SPECIFICATIONS ➀➃
Logic Supply Voltage Range
INVERTING
NON-INVERTING
8-32 Vdc (pin 3)
8-32 Vdc (pin 3)
8 mA
14 mA (plus pin 8 loading)
Input-On Voltage Range
8-32 Vdc (pin 6)
0-1.0 Vdc (pin 5)
Input-Off Voltage Range
0-0.4 Vdc (pin 6)
8-32 Vdc (pin 5)
6 mA (pin 6)
1.0 mA (pin 5)
Logic Supply Current @ 12 Vdc
Input-On Current @ 12 Vdc (Logic Supply)
ALARM SPECIFICATIONS ➀➃
NORMALLY CLOSED
Supply Voltage (with load)
Alarm-On Voltage
Open Col. NPN (pin 7)
Alarm-Off Voltage
Maximum Alarm Output Current
Alarm Delay (Min.-Max.)
RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ All voltages are positive in respect to common (pin 4).
SERIES SMR48-6
Rev. 111803
PAGE 1 OF 2
Supply Voltage (minus 1.0 V)
Active High PNP (pin 8)
1.5 Vdc
0.0 Vdc (with load)
Active Low NPN (pin 7)
Open Col. PNP (pin 8)
100 mA
100 mA
30-100 msec.
30-100 msec.
© 2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25˚C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard
NORMALLY OPEN
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
* Note:
*
SMR family of relays is not available for purchase in Germany
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series SMR48-6
25-90Amp • 480 Vac • AC OUTPUT
GENERAL SPECIFICATIONS
4000 Vrms
Dielectric Strength 50/60Hz Input/Output/Base
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
8 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Thermally Conductive Epoxy
Encapsulation:
Screws and Saddle Clamps Furnished, Unmounted
Output Terminals:
Input Connector (locking):
Panduit No. MLSS100-6 or Equivalent
Mating Connector (supplied):
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
Panduit No. CT100F22-6 or Equivalent
.95
(24.2)
8-32 TERMINAL
(2 PLACES )
WIRING DIAGRAM
AC
1
OUTPUT
AC
AC
2.30
.10
(2.54) (58.4)
TYP.
1.87
(47.5)
.025 SQUARE
TERMINALS
(6 PLACES)
.78
(19.8)
90A
50A
95
15
110
10
NO HEATSINK
5
40
90
100
2˚C/W
110
20
120
0
.5˚C/W
1.5˚C/W
Power Dissipation
2˚C/W
Base Plate Temp [˚C]
100
3˚C/W
20
1˚C/W
.5˚C/W
10
15
20
25
STATUS
CHART
20
40
60
80
Max Ambient Temp. [˚C]
Normal
Relay
OFF
Normal
Relay
ON
80
100
1˚C/W
110
40
120
120
NO HEATSINK
0
0
Load Current [Arms]
.2˚C/W
.4˚C/W
Power Dissipation
1˚C/W
25
90
120
60
Base Plate Temp [˚C]
30
5
8
CURRENT DERATING CURVES
25A
Logic Supply 8-32 Vdc
Common (–)
Control Non-Inverting
Control Inverting
Alarm N/C
Alarm N/O
3
Green LED
Input Status
1.80
(45.7)
Power Dissipation
Red LED
Alarm Status
INPUT
All dimensions are in inches (millimeters)
Screw Torque Requirements:
8-32 Screws - 20in./lbs.
(Screws dry without grease.)
AC
2
Base Plate Temp [˚C]
1.10
(27.9)
.45
(11.4)
10
20
30
40
Load Current [Arms]
50
20
40
60
20
80
Relay
Logic
Logic
Line Line Voltage Load
Supply Supply Loss Fails to
Low
Circuit
Voltage
Loss w/Control Turn ON
w/Control
High
Low
Impedance
LINE VOLTAGE
LOAD CURRENT
CONTROL INVERTING
CONTROL NON-INVERTING
GREEN LED
LOGIC SUPPLY
Relay
Fails
Shorted
40
60
80
Load Current [Arms]
Max Ambient Temp. [˚C]
0
20
40
60
80
Max Ambient Temp. [˚C]
Relay
Fails
Shorted
Crydom Heat Sinks offer excellent
thermal management and are perfectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom’s Heat Sink
specification sheet for all the
details.
RED LED & ALARM N/O
ALARM N/C
© 2003 CRYDOM CORP, Specifications subject to change without notice.
APPROVALS
UL
PENDING
CSA PENDING
VDE PENDING
FastFax Document No.154
SERIES SMR48-6
Rev. 111803
PAGE 2 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
* Note:
*
SMR family of relays is not available for purchase in Germany
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series T
10-25Amp • 120/240 Vac - AC OUTPUT
•
•
•
•
•
•
Featuring state-of-the-art Surface
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications.
Zero Voltage Switching
Panel Mount
600V Transient Capability
Internal Snubber
DC or AC Control
Triac Output
TA1210
TD1210
TA1225
TD1225
TA2410
TD2410
TA2425
TD2425
24-140
24-140
24-280
24-280
10
25
10
25
Min. Load Current, [mArms]
40
40
40
40
Transient Overvoltage [Vpk]
400
400
600
600
Max. Surge Current, (16.6ms) [Apk]
120
250
120
250
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
Thermal Resistance Junction to Case (R θJC) [˚C/W]
1.48
1.02
1.48
1.02
60
260
60
260
8
8
10
10
200
200
200
200
MODEL NUMBERS
AC CONTROL
D C CONTROL
Manufactured in Crydom's ISO 9001
Certified facility for optimum product
performance and reliability.
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current
➂ [Arms]
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
➁
Max. Turn-On Time
1/2 Cycle (DC Control), 10.0 msec (AC Control)
Max. Turn-Off Time
1/2 Cycle (DC Control), 40.0 msec(AC Control)
0.5
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
0.5
0.5
DC CONTROL
AC CONTROL
Control Voltage Range
3-32 Vdc
90-280 Vrms (60Hz)
Max. Reverse Voltage
-32 Vdc
---
Max. Turn-On Voltage
3.0 Vdc
90 Vrms
Min. Turn-Off Voltage
1.0 Vdc
10 Vrms
1500 Ohms
60K Ohms
Nominal Input Impedance
Typical Input Current
3.4mA @ 5 Vdc, 20mA @ 28Vdc
0.5
2mA @ 120 Vrms, 4mA @ 240 Vrms
© 2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25˚ C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 3.
Series T
Rev. 111703
Page 1 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 ¥ FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series T
10-25Amp • 120/240 Vac - AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
Max. Capacitance Input/Output
8 pF
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
Screws and Saddle Clamps Furnished, Unmounted
MECHANICAL DIMENSIONS
All dimensions are in inches (millimeters)
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
Screw Torque Requirements:
6-32 Screws - 10 in. lbs.,
8-32 Screws - 20in. lbs.
(Screws dry without grease.)
8-32 TERMINAL
(2 PLACES )
OUTPUT
1
2
1.87
(47.5)
--
+
4
3
INPUT
1.00
(25.4)
1.80
(45.7)
BASE PLATE
.125 (3.2)
Crydom Heat Sinks offer excellent
thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays.
Request CrydomÕ
s Heat Sink specifica
tion sheet for all the details.
2.30
(58.4)
1.70
(43.2)
6-32 TERMINAL
(2 PLACES)
.78
(19.8)
.90
(22.9)
CURRENT DERATING CURVES
10A
25A
12
30
110
5˚C/W
8
NO HEATSINK
115
4
120
25
100
3˚C/W
2˚C/W
20
15
110
10
NO HEATSINK
5
0
4
6
8
Load Current [Arms]
UL
E116949
CSA LR81689
VDE 10143 UG
Series T
Rev. 111703
PAGE 2 OF 2
120
0
2
APPROVALS
Base Plate Temp [˚C]
1˚C/W
Power Dissipation
Power Dissipation
9˚C/W
95
3˚C/W
Base Plate Temp [˚C]
7˚C/W
10
20
40
60
80
Max Ambient Temp. [˚C]
5
10
15
20
Load Current [Arms]
25
20
40
60
80
Max Ambient Temp. [˚C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 ¥ FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series PRG
150Amp • 120/240, 480 Vac - AC OUTPUT
• Zero Voltage and Random
Turn-On Swi tching
• Extra High Steady-Stat e
Current
• Panel M ount
• Internal Snubber
DC CONTROL
AC CONTROL
Featuring state-of-the-art Surface
Mount Technology, this SPST-NO
relay delivers proven reliability in the
most demanding applications.
Output consists of an SCR AC switch
and is available in zero-cross and random turn-on (phase controllable) versions.
Manufactured in Crydom's ISO 9001
Certified facility for optimum product
performance and reliability.
PRGD24150
PRGA24150
PRGD48150
PRGA48150
Operating Voltage (47-63 Hz) [Vrms]
24-280
48-530
Load Current Range ➂ [Arms]
.15-150
.15-150
600
1200
1750
1750
1.7
1.7
0.15
12,700
0.15
12,700
MODEL NUMBERS
OUTPUT SPECIFICATIONS ➀
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
Max. On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (RθJC) [ûC/W]
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁
5
500
5
500
Max. Turn-On Time ➃
1/2 cycle (DC Control), 10 msec (AC Control)
Max. Turn-Off Time
1/2 cycle (DC Control), 40 msec (AC Control)
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
DC(240V Models)
0.5
0.5
DC(480V Models)
AC
Control Voltage Range
3-15 Vdc
4-15 Vdc
90-140 Vac
Max. Turn-On Voltage
3.0 Vdc
4.0 Vdc
90 Vac
Min. Turn-Off Voltage
Nominal Input Impedance
Typical Input Current
1.0 Vdc
300 Ohms
15 mA @ 5 Vdc
1.0 Vdc
300 Ohms
15 mA @ 5 Vdc
10 Vac
14.1K Ohms
10 mA @ 120 Vac
© 2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25˚C and per section unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, see derating curves on page 2.
➃ Turn-On time for Random versions is 0.02 msec. (DC Control Models).
FastFax Document No. 153
PRG.
Rev. 111403
PAGE 1 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series PRG
150Amp • 120/240, 480 Vac - AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength (min.)
4000 Vac
Insulation Resistance (Min.) @ 500 Vdc
1010Ohm
Max. Capacitance Input/Output
10 pF
Ambient Operating Temperature Range
-30 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
12 oz. (340g)
Thermally Conductive Epoxy
Encapsulation:
Power Terminals:
M5 Screws Furnished, Mounted
Control Terminals:
.050 x .020 Square Pins
.125" Copper Base Plate
(Integral Part of Package)
CURRENT DERATING CURVES
.30
(7.6)
150A
Power Dissipation
120
110
90
1˚C/W
60
115
30
120
0
30
60
90 120
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
Crydom Heat Sinks offer excellent thermal management and are perfectly
matched to the load current ratings of
Crydom panel mount relays. Request
Crydom's Heat Sink specification sheet for
all the details.
-- +
AC
2.50
(63.5)
MOUNTING
HOLE/SLOT
0.16 (4.1) DIA.
INPUT
OUTPUT
100
.4˚C/W
.2˚C/W
.5˚C/W
105
150
.25
(6.3)
1.66
(42.2)
AC
180
Base Plate Temp [˚C]
210
.125
(3.2)
.95
(24.1)
1.17
(29.7)
.20
(5.1)
.20
(5.1)
.65
(16.5)
2.50
(63.5)
3.60
(91.4)
4.00
(101.5)
PIN DETAIL
.055
(1.4)
CUT HERE FOR FASTON
(AMP TYPE 61060-1 RECOMMEND)
.110 x .020 THICK
.400
(10.2)
All dimensions are in inches (millimeters)
AVAILABLE OPTIONS
-10 Random Turn-On (AC & DC Control)
Phase Controllable (DC Control)
Example: PRGA24 150-10
APPROVALS
PENDING
FastFax Document No. 153
PRG.
Rev. 111403
PAGE 2 OF 2
©2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Series PS
10-90Amp • 120/240 Vac - AC OUTPUT
•
•
•
•
•
Peak Switching
Panel Mount
600V Transient Capability
Internal Snubber
Input Status Indicator
Option Available
Output consists of an SCR AC switch turning ON
at the next peak of sinusoidal AC wave form after
the input has been activated. Continuing to
conduct normally until the input is de-activated
and then turning off at the next current zero cross
Suitable for switching of transformers and
other highly inductive loads where significant
inrush current may otherwise cause problems.
Manufactured in Crydom’s ISO 9001 Certified
facility for optimum product performance and
reliability.
Featuring state-of-the-art Surface Mount
Technology, these SPST-NO relays deliver
proven reliability in the most demanding
applications.
MODEL NUMBER
PSD2410
PSD2425
PSD2450
PSD2490
90-280
90-280
90-280
90-280
10
25
50
90
Min. Load Current, [mArms]
40
40
40
40
Transient Overvoltage [Vpk]
600
600
600
600
Max. Surge Current, (16.6ms) [Apk]
120
250
625
1200
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
Thermal Resistance Junction to Case (R θJC) [˚C/W]
1.48
1.02
0.63
0.28
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
60
260
1620
6000
Max. Off-State Leakage Current @ Rated Voltage [mArms]
10
10
10
10
500
500
500
500
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current
➂ [Arms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]
➁
Max. Turn-On Time
1/2 Cycle
Max. Turn-Off Time
1/2 Cycle
Power Factor (Min.) with Max. Load
0.5
0.5
0.5
0.5
INPUT SPECIFICATIONS ➀
Control Voltage Range
3-32 Vdc
Max. Reverse Voltage
-32 Vdc
Max. Turn-On Voltage
3.0 Vdc
Min. Turn-Off Voltage
1.0 Vdc
See Note ➃
Nominal Input Impedance
2mA ➃
Typical Input Current
© 2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25˚ C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 3.
➃ Input circuit incorporates active current limiter.
SERIES PS
Rev. 111403
PAGE 1 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Series PS
10-90Amp • 120/240 Vac - AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
8 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
MECHANICAL SPECIFICATIONS
3.0 oz. (86.5g)
Weight: (typical)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
Screws and Saddle Clamps Furnished, Unmounted
MECHANICAL OUTLINE
Screw Torque Requirements:
6-32 Screws - 10 in. lbs. max.
8-32 Screws - 20in. lbs. max.
(Screws dry without grease.)
AVAILABLE OPTIONS
G
Input Status Indicator
Example: PSD2425G
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
8-32 TERMINAL
(2 PLACES )
Note: Control Voltage Range 4.5-32Vdc
1
OUTPUT
Crydom Heat Sinks offer excellent
thermal management and are perfectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom’s Heat Sink
specification sheet for all the details.
--
+
4
3
INPUT
1.00
(25.4)
1.80
(45.7)
BASE PLATE
.125 (3.2)
6-32 TERMINAL
(2 PLACES)
10A
25A
12
30
110
5˚C/W
8
NO HEATSINK
115
4
120
25
100
3˚C/W
2˚C/W
20
15
110
10
NO HEATSINK
5
0
120
0
4
6
8
Load Current [Arms]
10
20
40
60
80
5
Max Ambient Temp. [˚C]
10
15
20
50A
.5˚C/W
90
100
2˚C/W
110
20
40
APPROVALS
UL/cUL E116950
50
80
20
40
60
90
.2˚C/W
.4˚C/W
80
80
Max Ambient Temp. [˚C]
100
1˚C/W
110
40
120
NO HEATSINK
0
30
60
.5˚C/W
Power Dissipation
1.5˚C/W
40
20
40
120
Base Plate Temp [˚C]
1˚C/W
Load Current [Arms]
20
Max Ambient Temp. [˚C]
90A
60
10
25
Load Current [Arms]
Base Plate Temp [˚C]
2
Power Dissipation
Base Plate Temp [˚C]
1˚C/W
Power Dissipation
9˚C/W
95
3˚C/W
Base Plate Temp [˚C]
7˚C/W
SERIES PS
Rev. 111403
PAGE 2 OF 2
.78
(19.8)
.90
(22.9)
All dimensions are in inches (millimeters)
CURRENT DERATING CURVES
Power Dissipation
2.30
(58.4)
1.70
(43.2)
2
1.87
(47.5)
120
0
20
40
60
80
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
G2 Series/ 1 FORM A
Solid State Relays
Model Number
Parameters
Input Characteristics
G2-1A02 G2-1A03 G2-1A05 G2-1A06 G2-1A07
Sym.
Test Conditions
Units
LED Forward Current - Turn on
IFon
IL = 100mA, t = 10ms
mADC
Max
Typ
LED Forward Current - Turn off
IFoff
IL = 0.2mA, VL = (Note 1)
mADC
Min
Typ
Recommended Forward Current
IF
mADC
Min
Max
LED Forward Voltage
VF
IF = 20mA
VDC
1 Form A 1 Form A 1 Form A 1 Form A 1 Form A
Max
5.0
2.0
0.1
1.8
10
30
1.1
1.4
5.0
2.0
0.1
1.8
10
30
1.1
1.4
5.0
2.0
0.1
1.8
10
30
1.1
1.4
5.0
2.0
0.1
1.8
10
30
1.1
1.4
5.0
2.0
0.1
1.8
10
30
1.1
1.4
Max
Min
Maximum Input Ratings
LED Forward Current
IF
50
50
50
50
50
LED Reverse Voltage Withstand
VR
IR = 10mA
Max
10
10
10
10
10
Switching Voltage
VL
IL = 50mA
V PEAK Max
400
400
400
250
150
Switching Current: AC Mode(Note2)
IL
Pin 4 to Pin 6
mA
Max
Switching Current: DC Mode(Note2)
Current Limit: AC Mode(Note2)
Current Limit: DC Mode(Note2)
On Resistance: AC Mode(Note2)
On Resistance: DC Mode(Note2)
IL
Pins 5(-) to Pins 4&6 (+)
mA
Max
Typ
150
250
380
540
24
6
0.5
5000
200
0.5
1
5.0
1.0
95
10
0.2
150
250
n/a
n/a
18
4.5
0.5
5000
200
0.5
1
5.0
1.0
95
10
0.2
120
200
380
540
35
8.75
0.5
5000
200
0.5
1
5.0
1.0
60
7
0.2
150
250
380
760
18
4.5
0.5
5000
200
0.5
1
5.0
1.0
110
15
0.2
450
900
n/a
n/a
5
1.25
0.5
5000
200
0.5
1
5.0*
1.0
170
30
0.2
3750
0.8
500
3750
0.8
500
3750
0.8
500
3750
0.8
500
3750
0.8
600
mADC
Output Characteristics
Off State Resistance
ILmt
IF = 5mA, t = 5ms
mA
ILmt
IF = 5mA, t = 5ms
mA
Typ
Ron
IF = 5mA, IL = 50mA
W
Max
Ron
IF = 5mA, IL = 50mA
W
Max
Roff
IF = 0mA, VL = 100V
GW
Min
Typ
Ioff
IF = 0mA, VL = 100V
nA
Ioff
IF = 0mA, VL = Max
mA
Max
Typ
Max
Ton
IF = 5mA, IL = 50mA
ms
Max
Toff
IF = 5mA, IL = 50mA
ms
Max
IF = 0mA, VL = 1V
pF
Typ
IF = 0mA, VL = 50V
pF
Typ
IF = 5mA
mV
Typ
t = 60sec
VRMS
Min
pF
Typ
mW
Max
Off State Leakage
Turn On Time
Turn Off Time
Capacitance - Across Output
Thermal Offset Voltage
General Characteristics
Dielectric Strength - Input to Output
Capacitance - Input to Output
Power Dissipation
Notes:
PDiss
1: VL for LED Forward Current - Turn Off is 50 Volts less than "Switching
Voltage : Max".
2: See "AC Mode and DC Mode Operation" on Page 67 for further
description of AC and DC Mode.
3: Specifications subject to change without notice.
* I F = 10mA
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH.
MOSFET Breakdown Voltage (Volts)
G2 Series/ 1 FORM A
Load Current (mA)
300
250
I(F) = 5 mA
200
150
100
G2-1A02
G2-1A03
G2-1A06
50
G2-1A05
G2-1A07
450
G2-1A02
G2-1A03
G2-1A05
G2-1A06
400
350
I(F) = 0 mA
G2-1A07
300
250
0
200
-40
-20
0
20
40
60
80
-40
-20
0
20
Temperature (Deg. C)
40
60
80
Temperature (Deg. C)
A. Load Current vs. Ambient Temperature
B. Output MOSFET BV vs. Ambient Temperature
250
G2-1A05
G2-1A02
G2-1A03
G2-1A06
G2-1A06
50%
G2-1A05
200
CapacitancerF)
(
Change in On Resistance (%)
Normalized to 25 ° C
70%
G2-1A07
30%
10%
-10%
I(F) = 5 mA
I(L) = 50 mA
-30%
G2-1A02
G2-1A03
G2-1A06
G2-1A07
100
50
0
-40
-20
0
20
40
Temperature (Deg. C)
60
0
80
250%
200%
Change in Turn Off Time (%
)
Normalized to 25 ° C
115%
G2-1A02
G2-1A03
G2-1A05
G2-1A06
G2-1A06
I(F) = 5 mA
I(L) = 50 mA
150%
100%
G2-1A07
50%
40
60
80
100
120
D. Output Capacitance vs. Applied Voltage
350%
300%
20
Bias Voltage (Volts)
C. On-Resistance vs. Ambient Temperature
Change in Turn On Time (%)
Normalized to 25 ° C
I(F) = 0 mA
f = 1 MHz
T= 25 deg. C
150
-50%
0%
G2-1A02
G2-1A03
G2-1A06
95%
75%
55%
G2-1A05
G2-1A07
35%
15%
-5%
I(F) = 5 mA
I(L) = 50 mA
-25%
-45%
-50%
-65%
-100%
-40
-20
0
20
40
60
-40
80
-20
0
Temperature (Deg. C)
20
40
60
80
Temperature (Deg. C)
F. Turn Off Time vs. Ambient Temperature
E. On Time vs. Ambient Temperature
8000
90
G2-1A02
G2-1A03
G2-1A05
T = 25 deg. C
I(L) = 50 mA
6000
5000
G2-1A06
4000
G2-1A07
80
Turn Off Time (mSec. )
7000
Turn On Time m
( Sec.)
Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
3000
2000
T = 25 deg. C
I(L) = 50 mA
70
60
G2-1A02
G2-1A03
G2-1A05
50
G2-1A06
40
1000
G2-1A07
30
0
0
5
10
15
20
25
30
35
40
45
50
LED Forward Current (mA)
G. Turn On Time vs. LED Forward Current
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
55
0
5
10
15
20
25
30
35
40
45
50
55
LED Forward Current (mA)
H. Turn Off Time vs. LED Forward Current
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com
G2 Series/ DUAL FORM A
Solid State Relays
Model Number
Parameters
Input Characteristics
Sym.
Test Conditions
Units
LED Forward Current - Turn on
IFon
IL = 100mA, t = 10ms
mADC
Max
Typ
LED Forward Current - Turn off
IFoff
IL = 0.2mA, VL = (Note 1)
mADC
Min
Typ
mADC
Min
Max
Recommended Forward Current
IF
LED Forward Voltage
VF
IF = 20mA
VDC
G2-DA01
G2-DA02
G2-DA03
G2-DA06
Dual Form A
Dual Form A
Dual Form A
Dual Form A
Max
5.0
2.0
0.1
1.8
10
30
1.1
1.4
5.0
2.0
0.1
1.8
10
30
1.1
1.4
5.0
2.0
0.1
1.8
10
30
1.1
1.4
5.0
2.0
0.1
1.8
10
30
1.1
1.4
Min
Maximum Input Ratings
LED Forward Current
IF
mADC
Max
50
50
50
50
LED Reverse Voltage Withstand
VR
IR = 10mA
VDC
Max
10
10
10
10
Switching Voltage
VL
IL = 50mA
V PEAK
Max
400
400
400
250
Switching Current
IL
120
70
380
180
125
n/a
180
125
380
Output Characteristics
Current Limit
ILmt
IF = 5mA, t = 5ms
mA
Typ
150
110
380
On Resistance
Ron
IF = 5mA, IL = 50mA
W
Max
24
35
18
18
Off State Resistance
Roff
IF = 0mA, VL = 100V
GW
Min
Typ
0.5
5000
0.5
5000
0.5
5000
0.5
5000
Ioff
IF = 0mA, VL = 100V
nA
200
0.5
1
5.0
200
0.5
1
5.0
200
0.5
1
5.0
200
0.5
1
5.0
1.0
95
10
0.2
1.0
60
7
0.2
1.0
95
10
0.2
1.0
110
5
1
0.2
3750
1.2
600
3750
1.2
600
3750
1.2
600
3750
1.2
600
Each Channel
mA
Max
Both Ch's Simultaneously
mA
Max
Ioff
IF = 0mA, VL = Max
mA
Max
Typ
Max
Turn On Time
Ton
IF = 5mA, IL = 50mA
ms
Max
Turn Off Time
Toff
IF = 5mA, IL = 50mA
ms
Max
IF = 0mA, VL = 1V
IF = 0mA, VL = 50V
pF
pF
Typ
Typ
IF = 5mA
mV
Typ
t = 60sec
VRMS
Min
Off State Leakage
Capacitance - Across Output
Thermal Offset Voltage
General Characteristics
Dielectric Strength - Input to Output
Capacitance - Input to Output
Power Dissipation
PDiss
pF
Typ
mW
Max
Notes:
1: VL for LED Forward Current - Turn Off is 50 Volts less than "Switching
Voltage : Max".
2: Specifications subject to change without notice.
Schematic Top View:
Mold mark on top of relay indicates Pin #1
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH.
Page 1 of 2
G2 Series/ DUAL FORM A
MOSFET Breakdown Voltage (Volts
200
180
Load Current (mA)
160
140
120
100
G2-DA01
G2-DA03
G2-DA02
80
60
40
I(F) = 5 mA
G2-DA06
20
475
425
-40
I(F) = 0 mA
325
275
-20
0
20
40
Temperature (Deg. C)
60
-40
80
-20
0
20
60
80
B. Output MOSFET BV vs. Ambient Temperature
60%
160
G2-DA01
G2-DA03
G2-DA06
G2-DA02
20%
G2-DA02
140
I(F) = 0 mA
f = 1 MHz
T = 25 deg. C
120
CapacitancerF)
(
40%
0%
-20%
100
G2-DA01
G2-DA03
G2-DA06
80
60
40
I(F) = 5 mA
I(L) = 50 mA
-40%
20
0
-60%
-40
-20
0
20
40
60
0
80
20
40
60
80
100
120
Bias Voltage (Volts)
Temperature (Deg. C)
C. On-Resistance vs. Ambient Temperature
D. Output Capacitance vs. Applied Voltage
140%
140%
120%
120%
G2-DA01
G2-DA02
G2-DA03
G2-DA06
100%
80%
60%
Change in Turn Off Time (%
)
Normalized to 25° C
Change in Turn On Time (%)
Normalized to 25° C
40
Temperate (Deg. C)
A. Load Current vs. Ambient Temperature
Change in On Resistance (%)
Normalized to 25° C
G2-DA01
G2-DA02
G2-DA03
G2-DA06
375
225
0
I(F) = 5 mA
I(L) = 50 mA
40%
20%
0%
-20%
-40%
G2-DA01
G2-DA03
G2-DA06
G2-DA02
100%
80%
60%
I(F) = 5 mA
I(L) = 50 mA
40%
20%
0%
-20%
-40%
-60%
-60%
-80%
-40
-20
0
20
40
60
-40
80
-20
0
Temperature (Deg. C)
20
40
60
80
Temperature (Deg. C)
F. Turn Off Time vs. Ambient Temperature
E. On Time vs. Ambient Temperature
90
5000
G2-DA01
G2-DA03
G2-DA02
T = 25 deg. C
I(L) = 50 mA
4000
80
Turn Off Time (mSec.)
Turn On Time m
( Sec.)
Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
G2-DA06
3000
2000
70
60
1000
40
0
30
0
5
10
15
20
25
30
35
40
45
50
LED Forward Current (mA)
G. Turn On Time vs. LED Forward Current
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
55
G2-DA01
G2-DA03
G2-DA02
50
T = 25 deg. C
I(L) = 50 mA
0
5
10
15
20
25
30
G2-DA06
35
40
45
50
55
LED Forward Current (mA)
H. Turn Off Time vs. LED Forward Current
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH.
Page 2 of 2
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com
G2 Series/
2 FORM A
Solid State Relays
Model Number
Parameters
Input Characteristics
G2-2A03
2 Form A
Sym.
Test Conditions
Units
LED Forward Current - Turn on
IFon
IL = 100mA, t = 10ms
ADC
m
Max
Typ
10
3.4
LED Forward Current - Turn off
IFoff
IL = 0.2mA, VL = (Note 1)
ADC
m
Min
Typ
Recommended Forward Current
IF
ADC
m
Min
Max
VD
C
Min
Max
0.1
3.0
15
40
1.1
1.4
LED Forward Voltage
IF = 20mA
VF
Maximum Input Ratings
LED Forward Current
LED Reverse Voltage Withstand
IF
ADC
m
Max
VR
IR = 10mA
VDC
Max
Switching Voltage
Switching Current
VL
IL = 50mA
V PEAK
Max
IL
Current Limit
ILmt
Each Channel
Both Ch.'s Simultaneously
IF = 5mA, t = 5ms
mA
mA
mA
Max
Max
Min
On Resistance
Off State Resistance
Ron
IF = 5mA/0mA, IL = 50mA
W
Max
Roff
IF = 0mA, VL = 15V
GW
Min
Typ
Ioff
IF = 0mA, VL = 15V
nA
Max
Typ
50
10
Output Characteristics
Max
Off State Leakage
Ioff
IF = 0mA, VL = Max
mA
Max
Turn On Time
Ton
IF = 10mA, IL = 50mA
ms
Max
Turn Off Time
Capacitance Across Output
Toff
IF = 10mA, IL = 50mA
ms
Max
IF = 0mA, VL = 1V
pF
Typ
IF = 0mA, VL = 50V
pF
Typ
IF = 10mA
mV
Typ
t = 60sec
VRMS
Min
Thermal Offset Voltage
15
250
150
n/a
n/a
8
0.5
5000
200
0.5
1
1.5
.
0.5
40
0.2
General Characteristics
Dielectric Strength - Input to Output
Capacitance - Input to Output
Power Dissipation
PDiss
pF
Typ
mW
Max
3750
1.2
600
Notes:
1: VL for LED Forward Current - Turn Off is 50 Volts less than "Switching
Voltage Max".
2: Specifications subject to change without notice.
* I F = 10mA
Schematic Top View:
Mold mark on top of relay indicates Pin #1
Package Drawings on Page 3
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH.
Page 1 of 2
MOSFET Breakdown Voltage (Volts)
G2 Series/ 2 FORM A
Load Current (mA)
250
200
150
100
G2-2A03
I(F) = 5 mA
50
0
500
450
400
350
300
250
200
G2-2A03
I(F) = 0 mA
150
100
50
0
-40
-20
0
20
40
60
80
-40
-20
0
Temperature (Deg C)
Change in On Resistance (%)
Normalized to 25° C
20
40
60
80
Temperature (Deg C)
A. Load Current vs. Ambient Temperature
B. Output MOSFET BV vs. Ambient Temperature
140%
G2-2A03
115%
I(F) = 5 mA
I(L) = 50 mA
90%
65%
40%
15%
-10%
-35%
-60%
-40
-20
0
20
40
60
80
Temperature (Deg C)
C. On-Resistance vs. Ambient Temperature
240%
G2-2A03
Change in Turn Off Time (%
)
Normalized to 25° C
Change in Turn On Time (%)
Normalized to 25° C
140%
I(F) = 5 mA
I(L) = 50 mA
190%
140%
90%
40%
-10%
-60%
-40
-20
0
20
40
60
G2-2A03
90%
40%
-10%
I(F) = 5 mA
I(L) = 50 mA
-60%
-110%
80
-40
-20
0
Temperature (Deg C)
20
40
60
80
Temperature (Deg C)
D. On Time vs. Ambient Temperature
E. Turn Off Time vs. Ambient Temperature
90
5000
T = 25 deg. C
I(L) = 50 mA
4000
Turn Off Time (mSec.)
80
Turn On Time (mSec.)
Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
G2-2A03
3000
2000
1000
T = 25 deg. C
I(L) = 50 mA
70
60
50
G2-2A03
40
0
30
0
5
10
15
20
25
30
35
40
45
50
55
LED Forward Current (mA)
F. Turn On Time vs. LED Forward Current
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
0
5
10
15
20
25
30
35
40
45
50
55
LED Forward Current (mA)
G. Turn Off Time vs. LED Forward Current
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH.
Page 2 of 2
Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
G2 Series/ FORM B
Solid State Relays
Model Number
Parameters
Input Characteristics
Sym.
Test Conditions
Units
LED Forward Current - Turn on
IFon
IL = 100mA, t = 10ms
mADC
Max
Typ
LED Forward Current - Turn off
IFoff
IL = 0.2mA, VL = (Note 1)
mADC
Min
Typ
mADC
Min
Max
Recommended Forward Current
LED Forward Voltage
IF
VF
G2-1B01
G2-1B02
G2-DB01
1 Form B
1 Form B
Dual Form B
G2-DB02
Dual Form B
Max
5.0
3.0
0.1
1.8
10
30
1.1
1.4
5.0
3.0
0.1
1.8
10
30
1.1
1.4
5.0
3.0
0.1
1.8
10
30
1.1
1.4
5.0
3.0
0.1
1.8
10
30
1.1
1.4
mADC
Max
50
50
50
50
VDC
Max
10
10
10
10
350
250
350
250
165
330
200
400
170
120
200
140
20
5.0
0.1
1.4
0.07
1.0
1.0
5.0
1.0
200
20
0.2
13
3.25
0.1
1.4
0.07
1.0
1.0
5.0
1.0
170
25
0.2
20
n/a
0.1
1.4
0.07
1.0
1.0
5.0
1.0
200
20
0.2
13
n/a
0.1
1.4
0.07
1.0
1.0
5.0
1.0
170
25
0.2
3750
0.8
500
3750
0.8
500
3750
1.2
600
3750
1.2
600
IF = 20mA
VDC
Min
Maximum Input Ratings
LED Forward Current
IF
LED Reverse Voltage Withstand
VR
IR = 10mA
Switching Voltage
VL
IL = 50mA
Switching Current
IL
Output Characteristics
V PEAK Max
(Note 2)
mA
Max
(Note 3)
mA
Max
On Resistance (Note 2)
On Resistance (Note 4)
Ron
IF = 5mA, IL = 50mA
W
Max
Ron
IF = 5mA, IL = 50mA
W
Max
Off State Resistance
Roff
IF = 0mA, VL = 100V
GW
Min
Typ
Ioff
IF = 0mA, VL = 100V
µA
Ioff
IF = 0mA, VL = Max
µA
Max
Typ
Max
Ton
IF = 5mA, IL = 50mA
ms
Max
Toff
IF = 5mA, IL = 50mA
ms
Max
IF = 0mA, VL = 1V
pF
Typ
IF = 0mA, VL = 50V
pF
Typ
IF = 5mA
µV
Typ
t = 60sec
VRMS
pF
Min
Typ
mW
Max
Off State Leakage
Turn On Time
Turn Off Time
Capacitance - Across Output
Thermal Offset Voltage
General Characteristics
Dielectric Strength - Input to Output
Capacitance - Input to Output
Power Dissipation
Notes:
PDiss
1: VL for LED Forward Current - Turn off is 50 Volts less than "Switching
Voltage : Max"
2: For G2-1B01 and G2-1B02: Output connected to pins 4 and 6.
For G2-DB01 and G2-DB02: Each channel.
3: For G2-1B01 and G2-1B02: Output connected to pin 5(-) and pins 4 & 6(+).
For G2-DB01 and G2-DB02: Both channels switching simultaneously
4: For G2-1B01 and G2-1B02: Output connected to pin 5(-) and pins 4 & 6(+).
5: Specifications subject to change without notice
* IF = 10mA
Schematic Top View:
Mold mark on top of relay indicates Pin #1
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH.
Page 1 of 2
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
150
100
G2-1B02
G2-DB02
I(F) = 0 mA
G2-1B01
50
600
MOSFET Breakdown Voltage (Volts)
Load Current (mA)
200
G2-DB01
550
500
G2-1B02
G2-DB02
450
400
300
250
-40
-20
0
20
40
60
80
-40
-20
0
20
Temperature (Deg. C)
60
80
B. Output MOSFET BV vs. Ambient Temperature
350.00
50%
40%
G2-1B02
G2-DB02
G2-1B01
G2-DB01
20%
300.00
CapacitancerF)
(
30%
10%
0%
-10%
I(F) = 0 mA
I(L) = 50 mA
-20%
G2-1B02
G2-DB02
I(F) = 5 mA
f = 1 MHz
T = 25 deg. C
250.00
200.00
G2-1B01
G2-DB01
150.00
100.00
50.00
-30%
-40%
0.00
-40
-20
0
20
40
60
80
0
20
40
60
Temperature (Deg. C)
80
100
120
Bias Voltage (Volts)
C. On-Resistance vs.Ambient Temperature
D. Output Capacitance vs. Applied Voltage
200%
120%
150%
G2-1B01
G2-1B02
G2-DB01
G2-DB02
100%
100%
Change in Turn Off Time (%
)
Normalized to 25° C
Change in Turn On Time (%)
Normalized to 25° C
40
Temperature (Deg. C)
A. Load Current vs. Ambient Temperature
Change in On Resistance (%)
Normalized to 25° C
G2-1B01
G2-DB01
I(F) = 5 mA
350
0
I(F) = 5 mA
I(L) = 50 mA
50%
0%
-50%
G2-1B02
G2-DB02
G2-1B01
G2-DB01
80%
60%
I(F) = 5 mA
I(L) = 50 mA
40%
20%
0%
-20%
-40%
-60%
-100%
-80%
-40
-20
0
20
40
60
80
-40
-20
0
Temperature (Deg. C)
20
40
60
80
Temperature (Deg. C)
E. On Time vs. Ambient Temperature
F. Turn Off Time vs. Ambient Temperature
9000
55
8000
6000
50
G2-1B02
G2-DB02
T = 25 deg. C
I(L) = 50 mA
7000
Turn Off Time (mSec.)
Turn On Time m
( Sec.)
Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com
G2 Series/ FORM B
G2-1B01
G2-DB01
5000
4000
3000
2000
45
40
35
30
G2-1B02
G2-DB02
G2-1B01
G2-DB01
T = 25 deg. C
I(L) = 50 mA
25
20
1000
15
0
0
5
10
15
20
25
30
35
40
45
50
LED Forward Current (mA)
G. Turn On Time vs. LED Forward Current
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
0
5
10
15
20
25
30
35
40
45
50
LED Forward Current (mA)
H. Turn Off Time vs. LED Forward Current
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH.
Page 2 of 2
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com
G2 Series/
1A/1B
Solid State Relays
Model Number
Parameters
Input Characteristics
LED Forward Current - Turn on
LED Forward Current - Turn off
Recommended Forward Current
LED Forward Voltage
Sym.
G2-AB01
1A/1B
G2-AB02
1A/1B
Max
Typ
5.0
2.0
5.0
2.0
mADC
Min
Typ
mADC
Min
Max
VDC
Min
Max
0.1
1.8
10
30
1.1
1.4
0.1
1.8
10
30
1.1
1.4
50
10
50
10
400
150
110
380
24
0.5
5000
0.5
5000
200
0.17
1
0.02
1
1
5.0
1.0
0.2
250
200
150
380
13
0.5
5000
0.5
5000
200
0.17
1
0.02
1
1
5.0
1.0
0.2
3750
1.2
600
3750
1.2
600
Test Conditions
Units
IFon
IL = 100mA, t = 10ms
mADC
IFoff
IL = 0.2mA, VL = (Note 1)
IF
IF = 20mA
VF
Maximum Input Ratings
LED Forward Current
LED Reverse Voltage Withstand
IF
VR
mADC
Max
IR = 10mA
VDC
Max
IL = 50mA
V PEAK
Max
mA
mA
Max
Max
mA
Typ
W
Max
Output Characteristics
Switching Voltage
Switching Current
Current Limit: N.O. Channel Only
On Resistance
Off State Resistance: N.O. Channel
Off State Resistance: N.C. Channel
Off State Leakage: N.O. Channel
Off State Leakage: N.C. Channel
Turn On Time
Turn Off Time
Thermal Offset Voltage
VL
IL
ILmt
Ron
Each Channel
Both Ch.'s Simultaneously
IF = 5mA, t = 5ms
IF = 5mA/0mA, IL = 50mA
Roff
IF = 0mA, VL = 100V
GW
Min
Typ
Roff
IF = 5mA, VL = 100V
GW
Min
Typ
Ioff
IF = 0mA, VL = 100V
nA
Max
Typ
Ioff
IF = 0mA, VL = Max
mA
Max
Ioff
IF = 5mA, VL = 100V
mA
Ioff
IF = 5mA, VL = Max
mA
Max
Typ
Max
Ton
IF = 5mA, IL = 50mA
ms
Max
Toff
IF = 5mA, IL = 50mA
ms
Max
IF = 5mA
mV
Typ
t = 60sec
VRMS
Min
pF
Typ
mW
Max
General Characteristics
Dielectric Strength - Input to Output
Capacitance - Input to Output
Power Dissipation
PDiss
Notes:
1: VL for LED Forward Current - Turn Off is 50 Volts less than "Switching
Voltage Max".
2: Specifications subject to change without notice.
* I F = 10mA
Schematic Top View:
Mold mark on top of relay indicates Pin #1
Package Drawings on Page 3
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH.
Page 1 of 3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
1A/1B
*See page 3 for characteristic curves of normally closed switches
MOSFET Breakdown Voltage (Volts)
200
180
Load Current (mA)
160
140
120
100
G2-AB01
80
60
NO I(F) = 5 mA
NC I(F) = 0 mA
G2-AB02
40
20
0
500
450
NO
G2-AB01
400
350
300
250
-20
0
20
40
60
80
-40
-20
0
Temperature (Deg C)
20
60
80
B. Output MOSFET vs. Ambient Temperature
60%
160
40%
140
NO
G2-AB01
G2-AB02
120
CapacitancerF)
(
20%
0%
-20%
-40%
NO
G2-AB01
G2-AB02
I(F) = 0 mA
f = 1 MHz
T = 25 deg. C
100
80
60
40
I(F) = 5 mA
I(L) = 50 mA
20
0
-60%
-40
-20
0
20
40
60
0
80
10
20
30
40
Temperature (Deg C)
50
60
70
80
90
100
110
Bias Voltage (Volts)
C. On-Resistance vs. Ambient Temperature
D. Output Capacitance vs. Applied Voltage
140%
140%
120%
120%
NO
G2-AB01
G2-AB02
100%
80%
Change in Turn Off Time (%
)
Normalized to 25° C
Change in Turn On Time (%)
Normalized to 25° C
40
Temperature (Deg C)
A. Load Current vs. Ambient Temperature
Change in On Resistance (%)
Normalized to 25° C
NO
G2-AB02
I(F) = 0 mA
200
-40
I(F) = 5 mA
I(L) = 50 mA
60%
40%
20%
0%
-20%
100%
NO
G2-AB01
G2-AB02
80%
60%
I(F) = 5 mA
I(L) = 50 mA
40%
20%
0%
-20%
-40%
-40%
-60%
-60%
-80%
-40
-20
0
20
40
60
80
-40
-20
0
Temperature (Deg C)
20
40
60
80
Temperature (Deg C)
E. On Time vs. Ambient Temperature
F. Turn Off Time vs. Ambient Temperature
100
5000
NO
G2-AB01
4000
90
Turn Off Time (mSec.)
Turn On Time (mSec.)
Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com
G2 Series/
T = 25 deg. C
I(L) = 50 mA
3000
NO
G2-AB02
2000
1000
T = 25 deg. C
I(L) = 50 mA
80
70
60
NO G2-AB01
50
NO G2-AB02
40
30
0
0
5
10
15
20
25
30
35
40
45
50
55
LED Forward Current (mA)
G. Turn On Time vs. LED Forward Current
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
0
5
10
15
20
25
30
35
40
45
50
55
LED Forward Current (mA)
H. Turn Off Time vs. LED Forward Current
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH.
Page 2 of 3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
1A/1B
MOSFET Breakdown Voltage (Volts)
600
550
500
NC
G2-AB02
450
I(F) = 5 mA
400
NC
G2-AB01
350
300
250
-40
-20
0
20
40
60
80
Temperature (Deg. C)
I. Output MOSFET BV vs. Ambient Temperature
350
40%
NC
G2-AB02
30%
20%
300
CapacitancerF)
(
Change in On Resistance (%)
Normalized to 25 ° C
50%
NC
G2-AB01
10%
0%
-10%
I(F) = 0 mA
I(L) = 50 mA
-20%
I(F) = 5 mA
f = 1 MHz
T = 25 deg. C
250
200
NC
G2-AB01
150
100
-40%
0
-40
-20
0
20
40
60
80
0
10
20
30
40
Temperature (Deg. C)
50
60
70
80
90
100
110
Bias Voltage (Volts)
K. Output Capacitance vs. Applied Voltage
J. On-Resistance vs. Ambient Temperature
200%
120%
100%
NC
G2-AB02
150%
100%
Change in Turn Off Time (%
)
Normalized to 25 D C
Change in Turn On Time (%)
Normalized to 25 ° C
NC
G2-AB02
50
-30%
I(F) = 5 mA
I(L) = 50 mA
NC
G2-AB01
50%
0%
-50%
NC
G2-AB02
80%
60%
NC
G2-AB01
40%
I(F) = 5 mA
I(L) = 50 mA
20%
0%
-20%
-40%
-60%
-100%
-80%
-40
-20
0
20
40
60
80
-40
-20
0
Temperature (Deg. C)
20
40
60
80
Temperature (Deg. C)
L. On Time vs. Ambient Temperature
M. Turn Off Time vs. Ambient Temperature
4500
55.00
4000
NC
G2-AB02
3500
T = 25 deg. C
I(L) = 50 mA
3000
Turn Off Time (mSec.)
Turn On Time (mSec.)
Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com
G2 Series/
NC
G2-AB01
2500
2000
1500
1000
45.00
35.00
T = 25 deg. C
I(L) = 50 mA
25.00
NC
G2-AB02
NC
G2-AB01
500
0
15.00
0
5
10
15
20
25
30
35
40
45
50
55
0
LED Forward Current (mA)
N. Turn On Time vs. LED Forward Current
5
10
15
20
25
30
35
LED Forward Current (mA)
40
45
50
O. Turn Off Time vs. LED Forward Current
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH.
Page 3 of 3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Dual Relays
25-40Amp • 120/240, 480 Vac • AC OUTPUT
• Zero Voltage and Random
Turn-On Swi tching
• SCR Output
• Industry Standard Package
• Panel M ount
MODEL NUMBERS
OUTPUT SPECIFICATIONS ➀
D2425D
D2425DE
D2440D
D2440DE
Two totally independent AC output
relays come in a single standard panelmount package. Utilizing an AC switch
output with internal snubber, relays
provide greater protection against false
triggering. Model choices include zerovoltage or random turn-on (phase controllable) switching.
Manufactured in Crydom's ISO 9001
Certified facility for optimum product
performance and reliability.
H12D4825D
H12D4825DE
H12D4840D
H12D4840DE
Operating Voltage (47-63 Hz) [Vrms]
24-280
24-280
48-530
48-530
Load Current Range ➂ [Arms]
.15-25
.15-40
.15-25
.15-40
Transient Overvoltage [Vpk]
600
600
1200
1200
Max. Surge Current, (16.6ms) [Apk]
250
625
250
625
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
1.02
.63
1.02
.63
260
1620
260
1620
10
10
10
10
500
500
500
500
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
0.5
0.5
0.5
0.5
Thermal Resistance Junction to Case (RθJC) [ûC/W]
➀
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁
Max. Turn-On Time
➃
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
D24XXD
H12D48XXD
E-SUFFIX
Control Voltage Range
4-15Vdc
4-15Vdc
15-32Vdc
Max. Turn-On Voltage
4.0 Vdc
4.0 Vdc
15 Vdc
Min. Turn-Off Voltage
1.0 Vdc
1.0 Vdc
1.0 Vdc
300 Ohms
240 Ohms
13mA
13mA
Nominal Input Impedance
Typical Input Current @ 5Vdc (@ 24Vdc for E-Suffix)
15mA
© 2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25˚C and per section unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ Turn-on time for random turn-on (-10) versions is 0.1 msec.
FastFax Document No. 165
DUAL.
Rev. 111203
PAGE 1 OF 2
1500 Ohms
Crydom Heat Sinks offer excellent thermal
management and are perfectly matched to the
load current ratings of Crydom panel mount
relays. Request Crydom's Heat Sink specification sheet for all the details.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Dual Relays
25-40Amp • 120/240, 480 Vac • AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
10 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
.25' Fastons, .025' Square Pins
120/240 V MO DEL
AVAILABLE OPTIONS
-10
1.17
(29.7)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
Random Turn-On,
Phase Controllable
Example: D2440D-10
1.00
(25.4)
A2
15-32Vdc Control
Example: H12D4840DE
B1 B2
120/24OV - 20A
120/24OV - 20A
120/24OV - 20A
2.30
(58.4)
2.30 1.87
(58.4) (47.5)
CONTROL A
1.87 1.60
(47.5) (40.6)
CONTROL B
4-15VDC ±
H
A1 A2
B2
A1
MOUNTING HOLE/SLOT
.017 (4.3) DIA.
2 PLC'S
.250 X .032 FASTON
TERMINAL
(4 PLACES)
.55
(14.0)
B1
120/24OV - 20A
E
480V MO DEL
FASTON
TERMINAL
.250 X .032
(4 PLACES)
.15
(3.8)
± 4-15VDC
CONTROL
Heat Transfer Pad (Attached)
Example: D2440DH
-
.50
(12.7)
PIN .025 SQ.
.100 CENTERS
4 PLACES
A
1.80
(45.7)
B
+
-
.77
(19.6)
.85
(21.6)
1.31
(33.2)
.45
(11.4)
CONTROL
+
.187 X .032
FASTON
TERMINAL
(4 PLACES)
1.37
(34.8)
1.80
.85
(21.6)
1.31
(33.2)
All dimensions are in inches (millimeters)
85
25A LIMIT
(1 SECTION)
2.0˚C/W
1.0˚C/W
95
5.0˚C/W
105
20
0
100
40A
80A LIMIT
(2 SECTIONS)
80
60
0.5˚C/W
40A LIMIT
(1 SECTION)
40
90
95
1.0˚C/W
100
2.0˚C/W
20
105
5.0˚C/W
Max Allowable Base Temp. [˚C]
40
Power Dissipation [W]
Power Dissipation [W]
75
0.5˚C/W
Max Allowable Base Temp. [˚C]
CURRENT DERATING CURVES
25A
50A LIMIT
(2 SECTIONS)
0
10
20
30
40
50
10
20
Load Current [Arms]
30
40
50
60
70
Max Ambient Temp. [˚C]
80
20
40
480Vrms
120/240Vrms
LOAD A
A2
B1
A1
B2
LOAD B
60
80 100 10
Load Current [Arms]
FastFax Document No. 165
DUAL.
Rev. 111203
PAGE 2 OF 2
40
50
LOAD B
60
70
80
480Vrms
120/240Vrms
A1 A2
B1 B2
480V Model
W IRING DIAGRAM S
APPROVALS
UL E116949
CSA LR81689 (240V only)
VDE 5902 UG
30
Max Ambient Temp. [˚C]
LOAD A
240V Model
-- B CONTROL
+ B CONTROL
-- A CONTROL
+ A CONTROL
20
-- A CONTROL
+ A CONTROL
+ B CONTROL
-- B CONTROL
©2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Quad Relay
20Amp • 120/240 Vac - AC OUTPUT
• Zero Voltage and Random
Turn-On Swi tching
• Triac Output
• Industry Standard Package
• Panel M ount
MODEL NUMBER
Four independent AC output relays
come in a single standard panel-mount
package. Utilizing an AC switch output
with internal snubber, relays provide
greater protection against false triggering. Model choices include zero-voltage or random turn-on (phase controllable) switching.
Manufactured in Crydom's ISO 9001
Certified facility for optimum product
performance and reliability.
TD2420Q
TD2420QE
Operating Voltage (47-63 Hz) [Vrms]
24-280
24-280
Load Current Range ➂ [Arms]
OUTPUT SPECIFICATIONS ➀
.15-20
.15-20
Transient Overvoltage [Vpk]
600
600
Max. Surge Current, (16.6ms) [Apk]
250
250
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
Thermal Resistance Junction to Case (RθJC) [ûC/W]
1.2
1.2
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
260
260
10
10
200
200
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
0.5
0.5
Control Voltage Range
4-15 Vdc
15-28 Vdc
Max. Turn-On Voltage
4.0 Vdc
15 Vdc
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁
Max. Turn-On Time
➃
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
Min. Turn-Off Voltage
Nominal Input Impedance
Typical Input Current
1.0 Vdc
1.0 Vdc
330 Ohms
1500 Ohms
12 mA @ 5Vdc
15 mA @ 24Vdc
©2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25˚C and per section unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, max. 20A per section, max. 60A per package.
➃ Turn-on time for random turn-on versions is 0.1 msec.
FastFax Document No. 166
QUAD
Rev. 111403
PAGE 1 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Quad Relay
20Amp • 120/240 Vac - AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
2500 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
10 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
3.5 oz. (109g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
.25Ó Faston, .025 Square Pins
MOUNTING HOLE/SLOT
.017 (4.3) DIA.
.025 SQ. PINS
2 PLC'S
ON .100 CENTERS
.250 X .032 FASTON
TERMINAL
(8 PLACES)
AVAILABLE OPTIONS
-10
H
E
1.126
(28.6)
Random Turn-On, Phase Controllable
Example: TD2420Q-10
-DC SECTION A
2.30
(58.4)
Heat Transfer Pad (Attached)
Example: TD2420QH
C1
A1 A2
120/24OV - 20A
-DC SECTION B
-DC SECTION
B1
15-28Vdc Control
Example: TD2420QE
B2
C
+DC COMMON
-DC SECTION
120/24OV - 20A
C2
120/24OV - 20A
D
1.87 1.60
(47.5) (40.6)
All dimensions are in inches (millimeters)
120/24OV - 20A
D1 D2
.77
(19.6)
.375
(9.5)
.85
(21.6)
1.37
(34.8)
1.80
(45.7)
CURRENT DERATING CURVES
W IRING DIAGRAM
Power Dissipation [W]
0.25¼C/W
75
80
0.5¼C/W
90
1.0¼C/W
40
2.0¼C/W
105
5.0¼C/W
0
15
30
45
Total Load Current [Arms]
60
20
40
60
80
Max Ambient Temp. [˚C]
Max Allowable Base Temp. [¼C]
100
120/240Vrms
120/240Vrms
LOAD B
LOAD D
B1
A1
B2
A2
D1
C1
D2
C2
LOAD A
LOAD C
120/240Vrms
120/240Vrms
-- DC SECTION C
-- DC SECTION A
+ DC COMMON
-- DC SECTION B
-- DC SECTION D
Crydom Heat Sinks offer excellent
thermal management and are perfectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom's Heat Sink
specification sheet for all the details.
APPROVALS
UL E116949
CSA LR81689
FastFax Document No. 166
QUAD
Rev. 111403
PAGE 2 OF 2
©2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series 53TP
25-50Amp • 240/480 Vac - 3 PHASE
• SCR Output
• LED Status Indicator
• Protective Cover Available
(Part No. KS300)
• Panel M ount
• Integrated Overvoltage
Protection by Automatic
Self Turn-On (Suff ix P)
MODEL NUMBERS
Three-phase solid state relays switch up
to 530 Vrms directly to loads such as
motors, transformers, heating elements,
etc. Available with either AC or DC
input (coil) control in zero-voltage or
random turn-on switching versions.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
D53TP25D
D53TP50D
A53TP25D
A53TP50D
Operating Voltage (47-63 Hz) [Vrms]
48-530
48-530
48-530
48-530
Load Current Range➂ [Arms]
.05-25
.05-50
.05-25
.05-50
Transient Overvoltage [Vpk]
1200
1200
1200
1200
Max. Surge Current, (16.6ms) [Apk]
250
625
250
625
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
Thermal Resistance Junction to Case (RθJC) [˚C/W]
1.02
.63
1.02
.63
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
260
1620
260
1620
10
10
10
10
500
500
500
500
1/2 Cycle
1/2 Cycle
10.0 msec
10.0 msec
1/2 Cycle
1/2 Cycle
40.0 msec
40.0 msec
0.5
0.5
0.5
0.5
OUTPUT SPECIFICATIONS ➀
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁
Max. Turn-On Time
➃
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
DC CONTROL
AC CONTROL
Control Voltage Range
3-32 Vdc
90-280 Vrms (60Hz)
Max. Turn-On Voltage
3.0 Vdc
90 Vrms
Min. Turn-Off Voltage
1.0 Vdc
10 Vrms
450 Ohms
54.8k Ohms
Nominal Input Impedance
10mA @ 5 Vdc
Typical Input Current
2.2mA @ 120 Vrms, 4.4mA @ 240 Vrms
©2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25ºC and per section unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).
FastFax Document No.161
SERIES53TP.
Rev. 111003
PAGE 1 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series 53TP
25-50Amp • 240/480 Vac - 3 PHASE
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
4000 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
8 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80ºC
Ambient Storage Temperature Range
-40 to 125ºC
M ECHANICAL SPECIFICATIONS
Weight: (typical)
10.3 oz. (315g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
-10
DP
Non-Zero Cross,
Instantaneous Turn-On
Example: D53TP50D-10
A1
B1
H
C1
1.875
2 Controlled, 1 Linked (A1-A2) 2.125 (47.6)
Example: D53DP50D
(54.0)
Internal Overvoltage Protection.
Relay Will Self Trigger Between
900-1200 Vpk. Not Suitable For
Capacitive Loads.
Example: D53TP50DP
B2
.39 REF
(10.0)
Heat Trasfer Pad (Attached)
Example: D53TP50DH
1.18
(30.0)
Crydom Heat Sinks offer excellent
thermal management and are per
fectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom’s Heat Sink
specification sheet for all the details.
2.89
(73.4)
+
INPUT
STATUS
LED
A2
P
0.21
(5.3)
4.09
(103.8)
10-32
TERMINAL
(6 PLACES )
0.79
(20.1)
INPUT
AVAILABLE OPTIONS
Screws and Saddle Clamps Furnished
--
C2
.78
(19.8)
1.36
(34.5)
1.56
(39.6)
3.62
(91.9)
6-32
TERMINAL
(2 PLACES )
.79
(20.1)
.94
(24.0)
.125
(3.2)
BASE PLATE
THICKNESS
Screw Torque Requirements :
6-32 Screws - 10 in. lbs.,
8-32 and 10-32 Screws - 20in. lbs.
(Screws dry without grease.)
All dimensions are in inches (millimeters)
CURRENT DERATING CURVES
A53TP25D, D53TP25D
A53DP25D, D53DP25D .5ºC/W
80
40
105
110
20
115
Power Dissipation
100
100
1.5ºC/W
Base Plate Temp [ºC]
0.5ºC/W
60
105
1ºC/W
40
110
1.5ºC/W
115
20
120
120
0
0
5
10
15
20
25
Load Current [Arms]
20
40
60
5
80
10
15
60
80
95
90
0.5ºC/W
100
1ºC/W
60
105
1.5ºC/W
110
30
115
10
20
30
40
Load Current [Arms]
50
20
40
60
90
80
Max Ambient Temp. [ºC]
.25ºC/W
150
Base Plate Temp [ºC]
Power Dissipation
Power Dissipation
40
180
120
FastFax Document No.161
SERIES53TP
Rev. 111003
PAGE 2 OF 2
20
Max Ambient Temp. [ºC]
90
0.25ºC/W
APPROVALS
UL E116950
CSA LR81689
VDE 5941 UG
25
A53TP50D, D53TP50D
A53DP50D, D53DP50D
120
0
20
Load Current [Arms]
Max Ambient Temp. [ºC]
95
.5ºC/W
100
120
105
90
60
1ºC/W
110
1.5ºC/W
115
30
0
Base Plate Temp [ºC]
Power Dissipation
1ºC/W
Base Plate Temp [ºC]
60
120
10
20
30
40
Load Current [Arms]
50
20
40
60
80
Max Ambient Temp. [ºC]
©2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
SSeries
SSC
olid State DC Contactor
25Amp • 0-1000 Vdc - DC OUTPUT
•
•
•
•
IGBT Output
Panel Mount
High Voltage
Internal Overvoltage
Protection Available
• Control Voltage 12Vdc,
24Vdc, 36Vdc
Series SSC solid state DC contactors
feature IGBT technology for high
voltage DC switching applications
All models come in Crydom's
standard panel-mount package.
Manufactured in Crydom's ISO 9001
Certified facility for optium product
performance and reliability.
OUTPUT SPECIFICATIONS ➀
MODEL NUMBERS
SSC800-25
SSC1000-25
0-1000
0-800
Operating Voltage Range [Vdc]
900 ➃
1200 ➄
25
25
Min. Load Current [mA]
20
20
Max. Surge Current, [Adc] (10msec)
75
75
Max. On-State Voltage Drop @ Rated Current [Vdc]
1.6
1.6
Thermal Resistance Junction to Case [R θJC] C/W
0.8
0.8
Max. Off-State Leakage Current @ Rated Voltage [mA]
0.3
0.3
Max. Turn-On Time [msec]
1.5
1.5
Max. Turn-Off Time [msec]
1.5
1.5
Maximun Transient Voltage [Vpk]
Max. Load Current
➂ [Adc]
INPUT SPECIFICATIONS ➀
Nominal Control Voltage [Vdc] ➅
12
24
36
8-16
20-28
32-40
Maximum Turn-On Voltage [Vdc]
8
20
32
Minimum Turn-Off Voltage [Vdc]
1
1
1
Nominal Input Impedance [Ohm]
780
1500
2,400
15
15
Control Voltage Range [Vdc]
Typical Input Current at Nominal Voltage [mA]
GENERAL NOTES
15
© 2003 CRYDOM CORP, Specifications subject to change without notice.
➀ All parameters at 25ºC unless otherwise specified.
➁ Dielectric strength and insulation resistance are measured between input and output.
➂ Heat sinking required, for derating curves see page 2.
➃ Internal overvoltage protection included.
➄ Internal overvoltage protection not included.
➅ Use suffix -12, -24 or -36 to specify control voltage. For other values call factory
Sample: SSC800-25-24.
SERIES SSC.
Rev. 111703
PAGE 1 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
SSeries
SSC
olid State DC Contactor
25Amp • 0-1000 Vdc - DC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 60Hz
2500 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
50 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-30 to 80ºC
Ambient Storage Temperature Range
-40 to 125ºC
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
Screws and Saddle Clamps Furnished, Unmounted
MECHANICAL SPECIFICATIONS
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1.10
(27.9)
.45
(11.4)
WIRING CONNECTIONS
Input and output polarity must be observed.
Inductive loads must be diode suppressed.
8-32 TERMINAL
(2 PLACES )
4 (–)
1 (–)
2
1.87
(47.5)
-4
+
INPUT
DC
CONTROL
SOURCE
2.30
(58.4)
1.70
(43.2)
3
SSR
OUTPUT
OUTPUT
INPUT
LOAD
1
3 (+)
2 (+)
(–)
(+)
Transient Protection
BASE PLATE
.125 (3.2)
1.00
(25.4)
1.80
(45.7)
.78
(19.8)
.90
(22.9)
6-32 TERMINAL
(2 PLACES)
All loads are inductive, even ones that are not so labeled. An
inductive load will produce harmful transient voltages when it
is turned off. The more perfect the switch, the larger the transient voltages; the IGBT output is so nearly an ideal switch
that the transient voltages produced by seemingly "non-inductive" loads can cause damage if not suppressed. Diodes should
be fast recovery type with PIV rated greater than supply voltage.
Screw Torque Requirements: 6-32 Screws - 10 in. lbs., 8-32
- 20in. lbs. (Screws dry without grease.)
CURENT DERATING CURVE
2˚C/W
30
1˚C/W
3˚C/W
20
100
105
110
115
10
NO HEATSINK
120
Base Plate Temp [˚C]
Power Dissipation
25A
40
0
5
10
15
20
Load Current [Arms]
25 10 20 30 40 50 60 70 80
Max Ambient Temp. [˚C]
©2003 CRYDOM CORP, Specifications subject to change without notice.
SERIES SSC.
Rev. 111703
PAGE 2 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series SST
SOFT-START Modules • 10-90Amp • AC OUTPUT
• 120 & 240 Vac Models
tory about use with 480 Vac loads. For
a complete set (control module and
solid state relay) order 10SST120,
25SST120, etc.
Manufactured in Crydom's ISO 9002
Certified facility for optimum product
performance and reliability.
Models SST120 and SST240 auxiliary
function modules gradually apply
power to the load when energized by
the control voltage. They must be used
with Crydom Series 1 (-10) random
turn-on solid state relays. Consult fac-
MODEL NUMBERS
120 Vac
10SST120
25SST120
40SST120
240 Vac
10SST240
25SST240
50SST240
75SST240
90SST240
RELAY OUTPUT SPECIFICATIONS ➀
90-140 (120 Vac Models)
180-280 (240 Vac Models)
Operating Voltage Range (47-63 Hz) [Vrms]
Load Current Range ➂ [Arms]
.04-10
.04-25
.04-50
.04-75
.04-90
400 (120 Vac models)
600 (240 Vac models)
Transient Overvoltage [Vpk]
120
Max. Surge Current, (16.6ms) [Apk]
250
625
1000
1200
1.6
1.6
1.6
1.6
1.6
Thermal Resistance Junction to Case (RθJC) [¡C/W]
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
1.48
1.02
.63
.31
.28
60
260
1620
4150
6000
Max. Off-State Leakage Current @ Rated Voltage [mArms]
10.0
10.0
10.0
10.0
10.0
Max. On-State Voltage Drop @ Rated Current [Vpk]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
500
500
500
500
500
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
1/2 cycle
0.5
0.5
0.5
0.5
0.5
CONTROL M ODULE INPUT SPECIFICATIONS ( Terminal 3B ) ➀
DC CONTROL
Control Voltage Range
3.5-10Vdc
Max. Turn-On Voltage
3.5 Vdc
Min. Turn-Off Voltage
1.0 Vdc
Typical Input Current
1.6mA @ 5Vdc
Nominal Turn-On Delay Time @ 60Hz
150 msec
Nominal Swell (Ramp) Time @ 60Hz
180 msec
Max. Reset Time
100 µsec
CONTROL M ODULE OUTPUT SPECIFICATIONS (Terminal 4B-Input to relay)➀
Max. Off-State Operating Voltage
Max. Load Current (Sink)
Max. On-State Voltage @ 3mA
Max. Off-State Leakage @ 10Vdc
GENERAL NOTES
DC CONTROL
36 Vdc
3.0 mAdc
0.5 Vdc
1.0 µAdc
©2003 CRYDOM CORP, Specifications subject to change without notice.
➀ All parameters at 25˚C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard
RS-443, paragraph 13.11.1
➂ Heat sinking required (Relay Only),
see Series 1 data sheet.
FastFax Document No. 202
SERIES SST
Rev. 111703
PAGE 1 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series SST
SOFT-START Modules • 10-90Amp • AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength, Signal to Load
4000 Vrms
Dielectric Strength, Signal to Base
4000 Vrms
Ambient Operating Temperature Range
-30 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (43g)
Encapsulation:
Thermally Conductive Epoxy
AVAILABLE OPTIONS
SST120 Control Module Only (120 Vac line)
SST240 Control Module Only (240 Vac line)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1.10
(27.9)
.50
(12.7)
.270 (2)
(6.9)
FASTON TERMINAL
.250 X .032
4 PLCS.
DERATING CURVES Ð See Series 1
W IRING DIAGRAM
2.30
(58.4)
1.70
(43.2)
1.87
(47.5)
OUTPUT
1A 1B
2B 2A
SOFT-START
-- MODULE3B+3A
4A 4B
1.00
(25.4)
1.80
(45.7)
.270 FASTON
(6.9) TERMINAL
.187 X .032
4 PLCS.
.78
(19.8)
.87
(22.2)
INPUT
Control
Voltage (+)
All dimensions are in inches (millimeters)
Gnd (Ð)
Line
Load
OUTPUT
1
2
Ð10 RELAY
4
--
3
INPUT
+
Notes
1. Following pins may be interchanged: 1A & 1B, 2A & 2B, 3A & 3B.
2. Pin 4A & 4B may not be interchanged.
3. The line and load may be interchanged.
©2003 CRYDOM CORP, Specifications subject to change without notice.
APPROVALS
UL E116949
FastFax Document No. 202
SERIES SST
Rev. 111703
PAGE 2 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series NTD/NTA
10-25Amp • 120/240 Vac • AC OUTPUT
• Panel Mount
• Zero Voltage or Random
Turn-On Switching
• Wide Control Voltage
Range
• DC Control, AC Control
The Series NTD is available featuring
zero-voltage or random switching and a
broadened operating range (24280Vac). This wide range permits optimum performance at both 120Vac and
240Vac line voltages.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
AC Control (NTA) ➅
DC Control (NTD)
OUTPUT SPECIFICATIONS ➀
NTD2405
NTD2410
NTD2425
NTA2410
NTA2425
24-280
24-280
24-280
24-280
24-280
0.15-5
0.15-10
0.15-25
0.15-10
0.15-25
600
600
600
600
600
Max. Surge Current, (16.6ms) [Apk]
40
120
250
120
250
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
1.6
Thermal Resistance Junction to Case (R θJC) [˚C/W]
4.5
1.48
1.02
1.48
1.02
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
7.0
60
260
60
260
Max. Off-State Leakage Current @ Rated Voltage [mA]
.01
10
10
10
10
200
200
200
200
200
1/2 Cycle
1/2 Cycle
1/2 Cycle
10 ms
10 ms
1/2 Cycle
1/2 Cycle
1/2 Cycle
40 ms
40 ms
0.5
0.5
0.5
0.5
0.5
Control Voltage Range
4-15 Vdc
3-32 Vdc
3-32 Vdc
Max. Turn-On Voltage
4.0 Vdc
3.0 Vdc
3.0 Vdc
90 Vrms
90 Vrms
Min. Turn-Off Voltage
1.0 Vdc
1.0 Vdc
1.0 Vdc
10 Vrms
10 Vrms
Nominal Input Impedance
300 ohms
See note ⑤
See note ⑤
10.6 kOhm
10.6 kOhm
Typical Input Current @ 5 Vdc (@ 120 Vrms for NTA)
13 mAdc
10 mAdc
10 mAdc
10 mArms
10 mArms
Operating Voltage (47-63 Hz) [Vrms]
➂ [Arms]
Load Current Range
Transient Overvoltage [Vpk]
Min. Off-State dv/dt @ Max. Rated Voltage [V/ µsec] ➁
Max. Turn-On Time
➃
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
© 2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀
➁
➂
➃
⑤
➅
90-140 Vrms 90-140 Vrms
All parameters at 25˚C unless otherwise specified.
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
Heat sinking required, for derating curves see page 2.
Turn-On time for random turn-on versions is 0.02 msec. (DC control models)
Input circuitry incorporates active current limiter.
24 Vac Control Version Available (use suffix E)
FastFax Document No. 176
SERIES NTD/NTA
Rev. 111303
PAGE 1 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series NTD/NTA
10-25Amp • 120/240 Vac • AC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz, Input/Output/Base
3750 Vrms
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
10 pF
Max. Capacitance Input/Output
Ambient Operating Temperature Range
-40 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
MECHANICAL SPECIFICATIONS
Weight: (typical)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1
1.10
(27.9)
.45
(11.4)
8-32 TERMINAL
(2 PLACES )
OUTPUT
2
1.87
(47.5)
--
+
4
2.30
(58.4)
1.70
(43.2)
1.10
(27.9)
.45
(11.4)
FASTON TERMINAL
.250 X .032 (4 PLCS.)
.87 REF.
(22.2)
OUTPUT
1
--
6-32 TERMINAL
(2 PLACES)
.78
(19.8)
.90
(22.9)
All dimensions are in inches (millimeters)
2.30
(58.4)
2
1.87
(47.5)
Screw Torque Requirements:
6-32 Screws - 10 in./lbs.,
8-32 and 10-32 Screws - 20in./lbs.
(Screws dry without grease.)
1.70
(43.2)
+
4
1.00
(25.4)
1.80
(45.7)
BASE PLATE
.125 (3.2)
Screws and Saddle Clamps Furnished, Unmounted
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
3
INPUT
3.0 oz. (86.5g)
3
INPUT
Terminal Hardware Furnished:
4 Screws and 4 Saddle Clamps
.78
(19.8)
1.25
(31.8)
1.00
(25.4)
1.80
(45.7)
Crydom Heat Sinks offer excellent
thermal management and are perfectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom’s Heat Sink
specification sheet for all the details.
AVAILABLE OPTIONS
-10 Random Turn-On
Phase Controllable
Example: NTD2425-10
F
Faston Terminals
.250 x .032 Faston Terminals
(Shown above)
Example: NTD2425F
E
24 Vac Control
Example: NTA2425E
CURRENT DERATING CURVES
10A
30
120
110
5˚C/W
8
NO HEATSINK
115
4
120
25
Power Dissipation
2
1˚C/W
Base Plate Temp [˚C]
115
3
9˚C/W
Power Dissipation
NO HEATSINK
Base Plate Temp [˚C]
110
5˚C/W
4
95
3˚C/W
7˚C/W
10˚C/W
5
Power Dissipation
25A
12
6
100
3˚C/W
2˚C/W
20
15
110
10
NO HEATSINK
5
1
0
1
2
3
4
5
Load Current [Arms]
APPROVALS
UL
E116950
CSA PENDING
TUV PENDING
FastFax Document No. 176
SERIES NTD/NTA
Rev. 111303
PAGE 2 OF 2
10
20
40
60
80
Max Ambient Temp. [˚C]
120
0
2
4
6
8
Load Current [Arms]
10
20
40
60
80
Max Ambient Temp. [˚C]
5
10
15
20
Load Current [Arms]
25
20
40
60
80
Max Ambient Temp. [˚C]
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Base Plate Temp [˚C]
5A
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series CPV
Phase Control Modules
• 120 & 240 Vac Models
• 0-5 Vdc Phase Control
Models CPV120 and CPV240 auxiliary
function modules provide control of the
phased turn-on of a solid state relay, in
response to the application of a 0-5 Vdc
control signal. They must be used with
MODEL NUMBERS
Crydom Series 1 (-10) random turn-onsolid state relays. Consult factory about
use with 480 Vac loads. For a com
plete set (control module and solid state
relay) order 10CPV120, 25CPV120, etc.
Manufactured in Crydom's ISO 9001
Certified facility for optimum product
performance and reliability.
120 Vac
10CPV120
25CPV120
40CPV120
240 Vac
10CPV240
25CPV240
50CPV240
75CPV240
90CPV240
RELAY OUTPUT SPECIFICATIONS ➀
90-140 (120 Vac Models)
180-280 (240 Vac Models)
Operating Voltage Range (47-63 Hz) [Vrms]
Load Current Range ➂ [Arms]
.04-10
.04-25
.04-50
.04-75
.04-90
400 (120 Vac models)
600 (240 Vac models)
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
120
250
625
1000
1200
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.6
1.6
1.6
1.6
1.6
1.48
1.02
0.63
0.31
0.28
60
260
1620
4150
6000
Max. Off-State Leakage Current @ Rated Voltage [mArms]
10.0
10.0
10.0
10.0
10.0
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁
500
500
500
500
500
Thermal Resistance Junction to Case [RθJC] ¡C/W
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
0.02
Max. Turn-On Time [msec]
1/
2
Max. Turn-Off Time
0.02
cycle
0.5
Power Factor (Min.) with Max. Load
1/
2
0.02
1/
2
cycle
0.5
CONTROL M ODULE INPUT SPECIFICATIONS ➀
cycle
0.5
0.02
1/
2
cycle
0.5
0.02
1/
2
cycle
0.5
DC CONTROL
3.5-10Vdc
Logic Supply Range (Terminal 3A)
1.6mA @ 5Vdc
Typical Supply Current
0-5 Vdc
Control Voltage Range (Terminal 3B)
1500 Ohms
Nominal Control Input Impedance
1.0
Min. Turn-Off Voltage
CONTROL M ODULE OUTPUT (T erminal 4B Ð I nput t o R elay ) ➀
Max. Off-State Operating Voltage
36 Vdc
Max. Load Current (Sink)
3.0 mA
Max. On-State Voltage @ 3mA
0.5 Vdc
Max. Off-State Leakage @ 10Vdc
GENERAL NOTES
1.0 µAdc
© 2003 CRYDOM CORP, Specifications subject to change without notice.
➀ All parameters at 25¼C unless otherwise specified.
➁ Off-State dv/dt test method per
EIA/NARM standard RS-443,
paragraph 13.11.1
➂ Heat sinking required (Relay Only),
see Series 1 data sheet.
FastFax Document No. 203
SERIES CPV
Rev. 111103
PAGE 1 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Series CPV
Phase Control Modules
GENERAL SPECIFICATIONS
Dielectric Strength, Signal to Load
4000 Vrms
Dielectric Strength, Signal to Base
4000 Vrms
Ambient Operating Temperature Range
-30 to 80¼C
Ambient Storage Temperature Range
-40 to 125¼C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (43g)
Encapsulation:
AVAILABLE OPTIONS
CPV120 Control Module Only (120 Vac line)
CPV2 40 Control Module Only (120 Vac line)
Thermally Conductive Epoxy
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
1.10
(27.9)
.50
(12.7)
.270 (2)
(6.9)
FASTON TERMINAL
.250 X .032
4 PLCS.
DERATING CURVES Ð See Series 1
2.30
(58.4)
1.70
(43.2)
1.87
(47.5)
Positive
Supply (+)
(5Vdc)
1A 1B
2B 2A
-4A 4B
+
3B 3A
1.00
(25.4)
1.80
(45.7)
Control
Voltage (+)
(0 to 5Vdc)
Common (Ð)
.270 FASTON
(6.9) TERMINAL
.187 X .032
4 PLCS.
.78
(19.8)
.87
(22.2)
All dimensions are in inches (millimeters)
Line
Load
OUTPUT
1
2
Ð10 RELAY
4
3
INPUT
Notes
1. Following pins may be interchanged: 1A & 1B, 2A & 2B.
2. Pin 4A & 4B may not be interchanged, nor may pins 3A & 3B.
3. The line and load may be interchanged.
© 2003 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No. 203
SERIES CPV
Rev. 111103
PAGE 2 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series LPCV
Linear Proportional Load Controller
The LPCV Linear Proportional
Controllers control loads up 110
Amps. Changes in the input signal
linearly vary the firing angle of the
thyristor load control device. Control
circuitry and power switch are in the
same package. The PS-120 (120V)
and PS-240 (240V) power supplies are
designed for use with the LPCV controller to provide the 20Vac required
in addition to the control voltage.
• Precise Proportional Load
Control
• Optically Isolated
• 0-5 Vdc, 0-10 Vdc, 4-20mA
Input Control Models
• Control Circuit Requires no
Adjustment or Calibration
0-5 Vdc CONTROL
0-10 Vdc CONTROL
4-20 mA CONTROL
5LPCV2415
10LPCV2415
20LPCV2415
5LPCV2425
10LPCV2425
20LPCV2425
Operating Voltage (60 Hz) [Vrms]
20-300
20-300
Load Current Range
.10-15
MODE L NUMBERS
5LPCV2440
5LPCV2475 5LPCV24110
10LPCV2440 10LPCV2475 10LPCV24110
20LPCV2440 20LPCV2475 20LPCV24110
OUTPUT SPECIFICATIONS
[Arms]
20-300
20-300
20-300
.10-40
.15-75
.20-110
.10-25
Transient Overvoltage [Vpk]
600
600
600
600
600
Max. Surge Current, (16.6ms) [Apk]
150
250
625
1000
1500
10
15
20
30
50
1.48
1.02
0.63
0.31
0.28
94
260
1620
4150
9340
Maximum Voltage Drop (100% On) [Vpk]
1.6
1.6
1.6
1.6
1.6
Minmum Off-State dv/dt [V/µsec]
200
200
200
200
200
Power Factor (Min.) with Max. Load
0.5
0.5
0.5
0.5
0.5
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Thermal Resistance Junction to Case (R JC) [ûC/W]
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
INPUT SPECIFICATIONS
Control Range (Nominal)
Control Range Limits (Min/Msx)
Turn-On Threshold
0-5 Vdc
0-10 Vdc
4-20 mA
-0.5/10 Vdc
-1.0/20 Vdc
-0.5/25 mA
.25 Vdc
0.5 Vdc
4.5 mA
25K Ohms
460 Ohms
12.7K Ohms
Min. Input Impedance
© 2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25˚ûC unless otherwise specified.
② Linear taper potentiometer 1-10K Ohm, 1/2 Watt.
➂ 50Hz models available.
(20 mA) 10V
➃ 20Vac must be in phase with load.
TYPICAL APPLICATIONS
Firing Angle vs. Input Signal
5V
7.5V
5V
2.5V
2.5V
(4 mA) 0V
180
FastFax Document No. 207
SERIES LPCV.
Rev. 111303
PAGE 1 OF 3
0V
135
90
45
0
•
•
•
•
•
•
•
•
•
Infrared and Quartz Heaters
Resistive Heating Elements
Transformers
Rectified DC Motors
Thermal Forming Equipment
Blow Molding Equipment
Industrial Temperature Controllers
Conveyor Speed Control
Printing Applications
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series LPCV
Linear Proportional Load Controller
GENERAL SPECIFICATIONS
Dielectric Strength, Signal to Load
2500 Vrms
Dielectric Strength, Signal to Base
2500 Vrms
Ambient Operating Temperature Range
-30 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
MOUNTING SLOT
0.17 (4.3) DIA.
.62
(15.7)
~
5 4 3
12Vdc Output
For Manual Control
+
FastFax Document No. 207
SERIES LPCV.
Rev. 111303
PAGE 2 OF 3
.30 Typ.
(7.6)
1.60 Max.
(40.6)
.12
(3.0)
5
4
3
➁
Note: Not Used
if Connected to
Analog Card
.12
(3.0)
OUTPUT
2.50
(63.5)
1.00
(25.4)
INPUT
2.62
(66.5)
2.21
(56.1)
2.10
(53.3)
1.00
(25.4)
2.25
(57.2)
6-32 TERMINALS
(2 PLACES)
.250 FASTON
TERMINALS
(2 PLACES)
PS120/ PS240
PS120
120 Vac
PS240
240 Vac
20 Vac/100mA
20 Vac/100mA
Ambient Operating Temperature Range
-30 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
2
From Control
0-5 Vdc
0-10 Vdc
4-20 mA
2.00
(50.8)
Output Voltage 50/60Hz
PROPORTIONAL CONTROLLER
--
1.35 Max.
(40.6)
1.05
(26.7)
POW ER SUPPLY SPECIFICATIONS ➃
Input Voltage 50/60Hz
W IRING DIAGRAM
20 Vac from Power
Supply Module ➃
PS-120 (120Vac)
PS-240 (240Vac)
See note ➃
8-32 Screws, .25 Inch Fastons
PROPORTIONAL CONTROLLER
.250 FASTON
TERMINALS
(5 PLACES)
7 6
Terminals:
OUTPUT
8-32 TERMINALS
(2 PLACES)
1
Thermally Conductive Epoxy
1.52
(38.6)
Screw Torque Requirements :
6-32 Screws - 10 in./lbs.,
8-32 and 10-32 Screws - 20in./lbs.
(Screws dry without grease.)
OUTPUT
Encapsulation:
2.21
(56.1)
All dimensions are in inches
(millimeters)
6.0 oz. (175g)
8.6 oz. (245g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
6-32 Screws, .25 Inch Fastons
©2003 CRYDOM CORP, Specifications subject to change without notice.
NOTE: UNSUITABLE APPLICATIONS
The LPCV is not suitable for some load control applications including, but not limited to the following:
• AC Motor Control
• Three Phase Motors
• Tranformers requiring pure sine wave input
• Applications which cannot withstand thyristor noise
• Zero Crossing Applications
Please contact Crydom's application engineering department for additional information and specific application questions.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series LPCV
Linear Proportional Load Controller
CURRENT DERATING CURVES
15A
25A
15
30
116
NO HEATSINK
120
100
3˚C/W 2˚C/W
20
15
110
10
NO HEATSINK
5
Base Plate Temp [˚C]
5
6˚C/W
25
Power Dissipation
4˚C/W
10
95
1˚C/W
112
Base Plate Temp [˚C]
Power Dissipation
2˚C/W
120
124
0
0
3
6
9
12
15
Load Current [Arms]
40A
40
60
80
5
100
80
1˚C/W
110
40
Power Dissipation
.3˚C/W
Base Plate Temp [˚C]
.5˚C/W
Load Current [Arms]
60
60
80
80
20
Max Ambient Temp. [˚C]
40
60
80
0
Load Current [Arms]
20
40
60
90
.4˚C/W
.2˚C/W
.5˚C/W
120
100
80
1˚C/W
110
40
120
0
40
40
120
120
NO HEATSINK
0
20
20
Max Ambient Temp. [˚C]
160
95
Power Dissipation
110
20
Base Plate Temp [˚C]
100
2˚C/W
40
25
90
40
30
20
Base Plate Temp [˚C]
1˚C/W .5˚C/W
20
15
110A
120
1.5˚C/W
10
10
Load Current [Arms]
75A
60
Power Dissipation
20
Max Ambient Temp. [˚C]
0
80
30
Max Ambient Temp. [˚C]
60
90 120
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
PERCENTAGE ON vs. INPUT VOLTAGE
0-10 Vdc Control
100
100
80
80
60
60
Percentage ON
Percentage ON
0-5 Vdc Control
40
50 Hz
60 Hz
20
40
50 Hz
60 Hz
20
0
0
1
2
3
4
5
1
Input Voltage
2
3
4
5
6
7
8
9
10
Input Voltage
4-20 mA Control
100
Percentage ON
80
60
40
50 Hz
60 Hz
20
0
2
4
6
8
10
12
14
16
18
20
22
Input Voltage
©2003 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No. 207
SERIES LPCV.
Rev. 111303
PAGE 3 OF 3
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series PCV
Analog Input Power Controller
•
•
•
•
The PCV Series proportional controllers
are self contained power control modules integrating a complete phase fired
logic control system and a solid state
relay in the same standard package.
Typical applications include heaters,
vibratory feeders and tungsten lamps.
Operates at 60Hz & 50Hz
Internal Snubber
Industry Standard Package
Control Circuit Requires No
Adjustment or Calibration
MODEL NUMBERS
7PCV2415 7PCV2425
10PCV2415 10PCV2425 10PCV2450 10PCV2475 10PCV2490
OUTPUT SPECIFICATIONS➀
100-240
100-240
100-240
100-240
100-240
.15-15
.15-25
.15-50
.15-75
.15-90
Transient Overvoltage [Vpk]
600
600
600
600
600
Max. Surge Current, (1 Cycle) [Apk]
150
250
625
1000
1200
Max. Off-State Leakage Current @ Rated Voltage [mA]
10
15
20
20
20
Maximum I 2 t for Fusing (8.3 msec) [A 2sec]
94
260
1620
4150
6000
Maximum Voltage Drop (100% On) [Vpk]
1.6
1.6
1.6
1.6
1.6
Minimum Off-State dv/dt [V/µsec]
200
200
200
200
200
Power Factor (Min.) with Max. Load
0.5
0.5
0.5
0.5
0.5
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current Range [Arms]
INPUT SPECIFICATIONS ➀
7PCV24xx
10PCV24xx
2-7 Vdc
2-10 Vdc
4 mA
4 mA
Control Voltage Range
Typical Input Current @ 5 Vdc
GENERAL NOTES
© 2003 CRYDOM CORP, Specifications subject to change without notice.
All parameters at 25º C unless otherwise specified.
TYPICAL APPLICATIONS
• Industrial Temperature Controllers
• Light Dimming
• Vibratory Feeders
• Resistive Heating Elements
• Conveyor Speed Control
UNSUITABLE APPLICATIONS
The PCV is not suitable for some load applications
including, but not limited to the following:
•
•
•
•
Percentage On vs. Input Voltage
100
80
Percentage ON
➀
60
40
50 Hz
AC Motor Control
Three Phase Motors
Transformers requiring pure sine wave input
Zero Crossing Applications
Please contact Crydom’s application
engineering department for additional
information and specific application
questions.
FastFax Document No. 204
SERIES PCV.
Rev. 111403
85PAGE 1 OF 2
60 Hz
20
0
2.5
3.5
4.5
5.5
6.5
7.5
Input Voltage
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
8.5
9.5
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series PCV
Analog Input Power Controller
GENERAL SPECIFICATIONS
Dielectric Strength, Signal to Load
2500 Vrms
Dielectric Strength, Signal to Base
2500 Vrms
Ambient Operating Temperature Range
-30 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
3.5 oz. (100g)
Encapsulation:
Thermally Conductive Epoxy
Screws and Saddle Clamps Furnished, Unmounted
Terminals:
W IRING DIAGRAM
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
~
OUTPUT
1
-4
+
4
All dimensions are in inches (millimeters)
Screw Torque Requirements:
6-32 Screws - 10 in. lbs.,
8-32 and 10-32 Screws - 20in. lbs.
(Screws dry without grease.)
2.30
(58.4)
1.70
(43.2)
2
1.87
(47.5)
1 OUTPUT 2
PROPORTIONAL
CONTROLLER
8-32 TERMINAL
(2 PLACES )
3
INPUT
3
INPUT
1.00
(25.4)
1.80
(45.7)
--
+
6-32 TERMINAL
(2 PLACES)
.78
(19.8)
.90
(22.9)
25A
15A
30
15
2˚C/W
116
6˚C/W
NO HEATSINK
5
120
25
Power Dissipation
4˚C/W
10
Base Plate Temp [˚C]
Power Dissipation
CURRENT DERATING CURVES
95
1˚C/W
112
100
3˚C/W
2˚C/W
20
15
110
10
NO HEATSINK
5
Base Plate Temp [˚C]
BASE PLATE
.125 (3.2)
120
124
0
0
6
9
12
15
Load Current [Arms]
50A
40
60
5
80
.5˚C/W
95
.3˚C/W
.5˚C/W
100
60
1˚C/W
110
30
0
50
20
40
60
80
Max Ambient Temp. [˚C]
40
60
80
90
.2˚C/W
.4˚C/W
80
100
1˚C/W
110
40
120
120
120
NO HEATSINK
0
Power Dissipation
110
20
40
20
Max Ambient Temp. [˚C]
120
Base Plate Temp [˚C]
100
2˚C/W
30
25
.5˚C/W
Power Dissipation
1.5˚C/W
40
20
20
90
Base Plate Temp [˚C]
1˚C/W
Load Current [Arms]
15
90A
90
10
10
Load Current [Arms]
75A
60
Power Dissipation
20
Max Ambient Temp. [˚C]
Base Plate Temp [˚C]
3
0
15
30
45
60
Load Current [Arms]
75
20
40
60
80
Max Ambient Temp. [˚C]
20
40
60
80
Load Current [Arms]
0
20
40
60
80
Max Ambient Temp. [˚C]
©2003 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No. 204
SERIES PCV.
Rev. 111403
PAGE 2 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Series RPC
Solid State Proportional Controller
15-40Amp • 120/240/480 Vac - OUTPUT
• Uses Potentiometer for
Economical Pow er Control
• Industry Standard Package
8
MODEL
NUMBERS
RPC1215 RPC1225 RPC1240
The RPC series proportional controllers
provide a cost effective method of controlling power in many different applications such as heaters, universal
motors or incandescent lamps. A customer provided potentiometer is all that
is required for control. All modules are
supplied with KS100 protective cover.
RPC2415 RPC2425 RPC2440
RPC4815 RPC4825 RPC4840
200-240 200-240 200-240
400-480 400-480 400-480
OUTPUT SPECIFICATIONS ➀
90-130
90-130
90-130
Max. Load Current ➂ [Arms]
15
25
40
15
25
40
15
25
40
Min. Load Current, [mArms]
70
80
90
70
80
90
70
80
90
Transient Overvoltage [Vpk]
400
400
400
600
600
600
1200
1200
1200
Max. Surge Current, (16.6ms) [Apk]
150
250
625
150
250
625
150
250
625
Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
Thermal Resistance Junction to Case [RθJC]
1.48
1.02
.63
1.48
1.02
.63
1.48
1.02
.63
94
260
1620
94
260
1620
94
260
1620
Max. Off-State Leakage Current @ Rated Voltage [mArms] 10
10
10
7
7
7
3
3
3
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁ 500
500
500
500
500
500
500
500
500
Operating Voltage (47-63 Hz) [Vac]
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
Max. Turn-On Time
➃ [msec]
Max. Turn-Off Time [msec]
Power Factor (Min.) with Max. Load
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
Snubber (Internal)
yes
yes
yes
yes
yes
yes
no
no
no
INPUT SPECIFICATIONS ➀
Resistor, Variable [Ohms] ➃
150K (1W) 150K (1W) 150K (1W)
1M (1/2W) 1M (1/2W) 1M (1/2W) 1M (1/2W) 1M (1/2W) 1M (1/2W)
©2003 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25˚C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ Potentiometer should be selected with regards to line voltage isolation.
W ARNING
Control to load is not isolated, excercise care in handling the
RPC products to avoid the risk of electric shock.
FastFax Document No. 205
SERIES RPC.
Rev. 111403
PAGE 1 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Series RPC
Solid State Proportional Controller
15-40Amp • 120/240/480 Vac - OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength, All Terminals to Base
2500 Vrms
Ambient Operating Temperature Range
-30 to 80˚C
Ambient Storage Temperature Range
-40 to 125˚C
M ECHANICAL SPECIFICATIONS
Weight: (typical)
3.2oz. (90g)
Encapsulation:
Thermally Conductive Epoxy
Screws and Saddle Clamps Furnished, Unmounted
Terminals:
~
W IRING
DIAGRAM
1.10
(27.9)
.45
(11.4)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
8-32 TERMINAL
(2 PLACES )
CAUTION
1
2
PROPORTIONAL
CONTROLLER
4
All dimensions are in inches (millimeters)
All terminals are
at Line Voltage
Potential.
1
OUTPUT
2
1.87
(47.5)
4
3
INPUT
2.30
(58.4)
1.70
(43.2)
3
1.00
(25.4)
1.80
(45.7)
Variable Resistance
Screw Torque Requirements:
6-32 Screws - 10 in. lbs.,
8-32 and 10-32 Screws - 20in. lbs.
(Screws dry without grease.)
.78
(19.8)
.87
(22.1)
6-32 TERMINAL
(2 PLACES)
CURRENT DERATING CURVES
25A
15
NO HEATSINK
5
120
100
3˚C/W 2˚C/W
20
15
110
10
NO HEATSINK
5
3
6
9
12
Load Current [Arms]
15
20
40
60
1˚C/W .5˚C/W
40
5
Max Ambient Temp. [˚C]
10
15
20
25
Load Current [Arms]
20
40
60
100
2˚C/W
110
20
120
NO HEATSINK
0
80
90
1.5˚C/W
120
124
0
Power Dissipation
116
60
Base Plate Temp [˚C]
6˚C/W
25
Power Dissipation
10
95
1˚C/W
112
4˚C/W
Base Plate Temp [˚C]
2˚C/W
Power Dissipation
40A
30
Base Plate Temp [˚C]
15A
0
80
10
Max Ambient Temp. [˚C]
20
30
40
Load Current [Arms]
50
20
40
60
80
Max Ambient Temp. [˚C]
PERCENTAGE ON vs . INPUT RESISTANCE
RPC2415, RPC2425, RPC2440
RPC4815, RPC4825, RPC4840
100
100
80
80
80
60
40
Percentage ON
100
Percentage ON
Percentage ON
RPC1215, RPC1225, RPC1240
60
40
50 Hz
20
0
20
50 Hz
20
60 Hz
40
60
80
100
Input Resistance [k  ]
120
140
60 Hz
0
0
20
40
50 Hz
60 Hz
0
60
0
200
400
600
800
Input Resistance [k  ]
1000
1200
0
200
400
600
800
1000
1200
Input Resistance [k  ]
©2003 CRYDOM CORP, Specifications subject to change without notice.
FastFax Document No. 205
SERIES RPC.
Rev. 111403
PAGE 2 OF 2
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506