Series 1 10-90Amp • 120/240 Vac - AC OUTPUT Featuring state-of-the-art Surface Mount Technology, these SPST-NO relays deliver proven reliability in the most demanding applications. Output consists of an SCR AC switch and is available in zero-cross, random turnon (phase controllable) and normally closed (Form B) versions with either AC or DC input (coil) control. Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. • Zero Voltage and Random Turn-On Switching • Panel Mount • 600V Transient Capability • Internal Snubber • 110 & 125A Models Available • Integrated Overvoltage Protection by Automatic Self Turn-On (Suffix P) A1210 D1210 A1225 D1225 A1240 D1240 A2410 D2410 A2425 D2425 A2450 D2450 A2475 D2475 A2490 D2490 24-140 24-140 24-140 24-280 24-280 24-280 24-280 24-280 10 25 40 10 25 50 75 90 Min. Load Current, [mArms] 40 40 40 40 40 40 40 40 Transient Overvoltage [Vpk] 400 400 400 600 600 600 600 600 Max. Surge Current, (16.6ms) [Apk] 120 250 625 120 250 625 1000 1200 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 Thermal Resistance Junction to Case (R θJC) [˚C/W] 1.48 1.02 0.63 1.48 1.02 0.63 0.31 0.28 60 260 1620 60 260 1620 4150 6000 8 8 8 10 10 10 10 10 500 500 500 500 500 500 500 500 0.5 0.5 MODEL NUMBERS AC CONTROL D C CONTROL OUTPUT SPECIFICATIONS ➀ Operating Voltage (47-63 Hz) [Vrms] Max. Load Current ➂ [Arms] Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] Max. Off-State Leakage Current @ Rated Voltage [mArms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] Max. Turn-On Time ➁ ➃ 1/2 Cycle (DC Control), 10.0 msec (AC Control) 1/2 Cycle (DC Control), 40.0 msec(AC Control) Max. Turn-Off Time 0.5 Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ DC CONTROL 0.5 0.5 0.5 0.5 AC CONTROL 0.5 AC CONTROL (E SUFFIX) Control Voltage Range 3-32 Vdc 90-280 Vrms (60Hz) 18-36 Vrms Max. Reverse Voltage -32 Vdc --- --- Max. Turn-On Voltage 3.0 Vdc 90 Vrms 18 Vrms Min. Turn-Off Voltage 1.0 Vdc 10 Vrms 4.0 Vrms 1500 Ohms 60K Ohms 9.0K Ohms 3.4mA @ 5 Vdc, 20mA @ 28Vdc 2mA @ 120 Vrms, 4mA @ 240 Vrms 3mA @ 24 Vrms Nominal Input Impedance Typical Input Current © 2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ All parameters at 25˚ C unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 3. ➃ Turn-on time for random turn-on versions is 0.02 msec (DC Control Models). FastFax Document No. 151 SERIES1 Rev. 102104 PAGE 1 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Series 1 10-90Amp • 120/240 Vac - AC OUTPUT GENERAL SPECIFICATIONS 4000 Vrms Dielectric Strength 50/60Hz Input/Output/Base 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 8 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Terminals: Thermally Conductive Epoxy Screws and Saddle Clamps Furnished, Unmounted AVAILABLE OPTIONS -B Normally Closed (Form B) Example: D2450-B, A2450-B E 24 Vac Input (18-36 Vac) Example: A2450E F Faston Terminals (Up to 50A Models) Example: D1225F G Input Status LED. Agencies Approval Pending Example: D2450G Note: Control Voltage Range 4.5-32Vdc for DC Control Models. P 4D -10 Random Turn-On (AC & DC Control) Phase Controllable (DC Control) Example: D2450-10 Heat Transfer Pad (Attached) Example: D2450H Ordering System: Combination of the suffixes should be made in the following order: EFPG-10. Example: A2450EFPG-10 OUTPUT 1 8-32 TERMINAL (2 PLACES ) 2 1.87 (47.5) -4 6-32 TERMINAL (2 PLACES) 1.10 (27.9) .45 (11.4) OUTPUT 1 Fastons: Single pair (up to 25A) Double pair* (up to 50A). *Caution: User must connect to both pairs -- 4 2 + INPUT 1.00 (25.4) 1.80 (45.7) .78 (19.8) .90 (22.9) FASTON TERMINAL .250 X .032 (2 PLCS.) .87 REF. (22.2) 1.87 (47.5) BASE PLATE .125 (3.2) 2.30 (58.4) 1.70 (43.2) 3 1.00 (25.4) 1.80 (45.7) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Screw Torque Requirements: 6-32 Screws - 10 in. lbs., 8-32 and 10-32 Screws - 20in. lbs. (Screws dry without grease.) + INPUT BASE PLATE .125 (3.2) Internal Overvoltage Protection. Relay Will Self Trigger Between 450-600 Vpk. Not Suitable For Capacitive Loads. Not Available with -B Option Agencies Approval Pending. Example: D2425P 400 Hz Operation 10-50 Amp Models Only Zero Cross Switching Only Example: 4D2450 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 2.30 (58.4) 1.70 (43.2) 3 FASTON TERMINAL .187 X .032 (2 PLCS.) .78 (19.8) .90 (22.9) H APPROVALS UL E116949 CSA LR81689 VDE 10143 UG (Not Applicable: -B and 4D) FastFax Document No.151 SERIES1 Rev. 102104 PAGE 2 OF 3 Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specifica tion sheet for all the details. All dimensions are in inches (millimeters) © 2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Series 1 10-90Amp • 120/240 Vac - AC OUTPUT CURRENT DERATING CURVES 10A 25A 12 30 110 5˚C/W 8 NO HEATSINK 115 4 120 25 100 3˚C/W 2˚C/W 20 15 110 10 NO HEATSINK 5 4 6 8 10 Load Current [Arms] 50A 40 60 5 80 .5˚C/W 80 20 40 60 80 60 80 90 1˚C/W 110 40 .2˚C/W .4˚C/W Power Dissipation 100 Base Plate Temp [˚C] .3˚C/W .5˚C/W 80 100 1˚C/W 110 40 120 120 0 Max Ambient Temp. [˚C] 40 90A 120 NO HEATSINK 0 50 20 Max Ambient Temp. [˚C] 120 95 Power Dissipation 110 20 40 25 .5˚C/W Base Plate Temp [˚C] 100 2˚C/W 30 20 90 40 20 15 75A 1.5˚C/W Load Current [Arms] 10 Load Current [Arms] 120 1˚C/W Power Dissipation 20 Max Ambient Temp. [˚C] 0 15 30 45 60 Load Current [Arms] 75 20 40 60 80 Max Ambient Temp. [˚C] 20 40 60 80 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] © 2003 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No.151 SERIES1 Rev. 102104 PAGE 3 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Base Plate Temp [˚C] 2 10 120 0 0 60 Base Plate Temp [˚C] 1˚C/W Power Dissipation Power Dissipation 9˚C/W 95 3˚C/W Base Plate Temp [˚C] 7˚C/W Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series A48, D48 12-90Amp • 480 Vac - AC OUTPUT • Zero Voltage and Random Turn-On Switching • Panel Mount • 800V Transient Capability • Internal Snubber MODEL NUMBERS AC CONTROL D C CONTROL A4812 D4812 A4825 D4825 Featuring state-of-the-art Surface Mount Technology, these SPST-NO relays deliver proven reliability in the most demanding applications. Output consists of an SCR AC switch and is available in zero-cross, random turn-on (phase controllable) and versions with either AC or DC input (coil) control. Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. A4850 D4850 A4875 D4875 A4890 D4890 OUTPUT SPECIFICATIONS ➀ 80-530 80-530 80-530 80-530 80-530 12 25 50 75 90 Min. Load Current, [mArms] 40 40 40 40 40 Transient Overvoltage [Vpk] 800 800 800 800 800 Max. Surge Current, (16.6ms) [Apk] 140 250 625 1000 1200 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.7 1.7 1.7 1.7 1.7 Thermal Resistance Junction to Case (R θJC) [˚C/W] Operating Voltage (47-63 Hz) [Vrms] Max. Load Current ➂ [Arms] 1.48 1.02 0.63 0.31 0.28 Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] 81 260 1620 4150 6000 Max. Off-State Leakage Current @ Rated Voltage [mArms] 10 10 10 10 10 500 500 500 500 500 Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁ Max. Turn-On Time ➃ 1/2 Cycle (DC Input), 10.0 msec (AC Input) Max. Turn-Off Time 1/2 Cycle (DC Input), 40.0 msec (AC Input) 0.5 Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ DC CONTROL (D PREFIX) 0.5 0.5 0.5 AC CONTROL (A PREFIX) Control Voltage Range 3-32 Vdc 90-280 Vrms (60Hz) Max. Reverse Voltage -32 Vdc --- Max. Turn-On Voltage 3.0 Vdc 90 Vrms Min. Turn-Off Voltage 1.0 Vdc 10 Vrms See Note ➄ 60K Ohms 2.0 mA ➄ 2mA @ 120 Vrms, 4mA @ 240 Vrms Nominal Input Impedance Typical Input Current © 2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ ➁ ➂ ➃ ➄ All parameters at 25˚C unless otherwise specified. Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 Heat sinking required, for derating curves see page 2. Turn-on time for random turn-on versions is 0.02 msec (DC Control Models). Input circuitry incorporates active current limiter. FastFax Document No. SERIES A48/D48. Rev. 111003 PAGE 1 OF 3 0.5 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series A48, D48 12-90Amp • 480 Vac - AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 8 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS Weight: (typical) Encapsulation: Thermally Conductive Epoxy Screws and Saddle Clamps Furnished, Unmounted Terminals: AVAILABLE OPTIONS -10 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Random Turn-On (AC & DC Control) Phase Controllable (DC Control) Example: D4890-10 OUTPUT 1 F Faston Terminals (Up to 25 Amp Models) Example: D4850F H -- 2 + 4 Heat Transfer Pad (Attached) Example: D4850H INPUT 6-32 TERMINAL (2 PLACES) 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1 OUTPUT -4 2 + INPUT 1.00 (25.4) 1.80 (45.7) .78 (19.8) .90 (22.9) FASTON TERMINAL .250 X .032 (2 PLCS.) .87 REF. (22.2) 1.87 (47.5) BASE PLATE .125 (3.2) 2.30 (58.4) 1.70 (43.2) 3 1.00 (25.4) 1.80 (45.7) BASE PLATE .125 (3.2) Fastons: Single pair (up to 25A) Double pair* (up to 50A). *Caution: User must connect to both pairs Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. 8-32 TERMINAL (2 PLACES ) 1.87 (47.5) Screw Torque Requirements: 6-32 Screws - 10 in. lbs., 8-32 and 10-32 Screws - 20in. lbs. (Screws dry without grease.) 3.0 oz. (86.5g) 2.30 (58.4) 1.70 (43.2) 3 FASTON TERMINAL .187 X .032 (2 PLCS.) .78 (19.8) .90 (22.9) All dimensions are in inches (millimeters) APPROVALS UL E116949 CSA LR81689 VDE 10143 UG FastFax Document No. SERIES A48/D48 Rev. 111003 PAGE 2 OF 3 © 2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series A48, D48 12-90Amp • 480 Vac - AC OUTPUT CURRENT DERATING CURVES 12A 14 25A 12 30 110 5˚C/W 8 NO HEATSINK 6 115 4 120 25 4 6 8 10 12 .5˚C/W 40 60 5 80 20 80 60 80 Max Ambient Temp. [˚C] 40 60 80 90 1˚C/W 110 40 .2˚C/W .4˚C/W Power Dissipation 100 Base Plate Temp [˚C] .3˚C/W .5˚C/W 80 100 1ºC/W 110 40 120 120 0 40 20 Max Ambient Temp. [˚C] 90A 120 NO HEATSINK 0 20 25 120 95 Power Dissipation 110 20 50 15 .5˚C/W Base Plate Temp [˚C] 100 2˚C/W 40 10 Load Current [Arms] 90 40 30 120 75A 1.5˚C/W Power Dissipation 20 Max Ambient Temp. [˚C] 120 20 110 10 0 15 30 45 60 Load Current [Arms] 75 20 40 60 80 Max Ambient Temp. [˚C] 20 40 60 80 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] © 2003 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No. SERIES A48/D48. Rev. 111003 PAGE 3 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Base Plate Temp [˚C] 2 50A Load Current [Arms] 15 0 0 60 10 20 5 Load Current [Arms] 1˚C/W 2˚C/W NO HEATSINK 2 0 100 3˚C/W Base Plate Temp [˚C] 9˚C/W 1˚C/W Power Dissipation Power Dissipation 10 95 3˚C/W Base Plate Temp [˚C] 7˚C/W Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series A48, D48 12-90Amp • 480 Vac - AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 8 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS Weight: (typical) Encapsulation: Thermally Conductive Epoxy Screws and Saddle Clamps Furnished, Unmounted Terminals: AVAILABLE OPTIONS -10 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Random Turn-On (AC & DC Control) Phase Controllable (DC Control) Example: D4890-10 Faston Terminals (Up to 25 Amp Models) Example: D4850F H 1.87 (47.5) INPUT 6-32 TERMINAL (2 PLACES) 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1 OUTPUT 1.87 (47.5) 4 2 + INPUT 1.00 (25.4) 1.80 (45.7) .78 (19.8) .90 (22.9) FASTON TERMINAL .250 X .032 (2 PLCS.) .87 REF. (22.2) SOLID-STATE RELAY -- BASE PLATE .125 (3.2) 2.30 (58.4) 1.70 (43.2) 3 1.00 (25.4) 1.80 (45.7) BASE PLATE .125 (3.2) Fastons: Single pair (up to 25A) Double pair* (up to 50A). *Caution: User must connect to both pairs Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. + 4 Screw Torque Requirements: 6-32 Screws - 10 in. lbs., 8-32 and 10-32 Screws - 20in. lbs. (Screws dry without grease.) 2 SOLID-STATE RELAY -- Heat Transfer Pad (Attached) Example: D4850H 8-32 TERMINAL (2 PLACES ) OUTPUT 1 F 3.0 oz. (86.5g) 2.30 (58.4) 1.70 (43.2) 3 FASTON TERMINAL .187 X .032 (2 PLCS.) .78 (19.8) .90 (22.9) All dimensions are in inches (millimeters) APPROVALS UL E116949 CSA LR81689 VDE 10143 UG FastFax Document No. SERIES A48/D48 Rev. 111003 PAGE 2 OF 3 © 2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series A48, D48 12-90Amp • 480 Vac - AC OUTPUT CURRENT DERATING CURVES 12A 14 25A 12 30 110 5˚C/W 8 NO HEATSINK 6 115 4 120 25 4 6 8 10 12 .5˚C/W 40 60 5 80 20 80 60 80 Max Ambient Temp. [˚C] 40 60 80 90 1˚C/W 110 40 .2˚C/W .4˚C/W Power Dissipation 100 Base Plate Temp [˚C] .3˚C/W .5˚C/W 80 100 1ºC/W 110 40 120 120 0 40 20 Max Ambient Temp. [˚C] 90A 120 NO HEATSINK 0 20 25 120 95 Power Dissipation 110 20 50 15 .5˚C/W Base Plate Temp [˚C] 100 2˚C/W 40 10 Load Current [Arms] 90 40 30 120 75A 1.5˚C/W Power Dissipation 20 Max Ambient Temp. [˚C] 120 20 110 10 0 15 30 45 60 Load Current [Arms] 75 20 40 60 80 Max Ambient Temp. [˚C] 20 40 60 80 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] © 2003 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No. SERIES A48/D48. Rev. 111003 PAGE 3 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Base Plate Temp [˚C] 2 50A Load Current [Arms] 15 0 0 60 10 20 5 Load Current [Arms] 1˚C/W 2˚C/W NO HEATSINK 2 0 100 3˚C/W Base Plate Temp [˚C] 9˚C/W 1˚C/W Power Dissipation Power Dissipation 10 95 3˚C/W Base Plate Temp [˚C] 7˚C/W Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series HA, HD 12-90Amp • 480 Vac - AC OUTPUT Featuring state-of-the-art Surface Mount Technology, these SPST-NO relays deliver proven reliability in the most demanding applications. Output consists of an SCR AC switch and is available in zero-cross, random turn-on (phase controllable) and versions with either AC or DC input (coil) control. Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. • Zero Voltage and Random Turn-On Switching • Panel Mount • 1200V Transient Capability • Integrated Overvoltage Protection by Automatic Self Turn-On (Suffix P) • 110 & 125A Models Available HA4812 HD4812 HA4825 HD4825 HA4850 HD4850 HA4875 HD4875 HA4890 HD4890 48-530 48-530 48-530 48-530 48-530 12 25 50 75 90 Min. Load Current, [mArms] 40 40 40 40 40 Transient Overvoltage [Vpk] 1200 1200 1200 1200 1200 Max. Surge Current, (16.6ms) [Apk] 140 250 625 1000 1200 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.7 1.7 1.7 1.7 1.7 Thermal Resistance Junction to Case (R θJC) [˚C/W] MODEL NUMBERS AC CONTROL D C CONTROL OUTPUT SPECIFICATIONS ➀ Operating Voltage (47-63 Hz) [Vrms] Max. Load Current ➂ [Arms] 1.48 1.02 0.63 0.31 0.28 Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] 81 260 1620 4150 6000 Max. Off-State Leakage Current @ Rated Voltage [mArms] 10 10 10 10 10 500 500 500 500 500 Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] Max. Turn-On Time ➁ ➄ 1/2 Cycle (DC Input), 10.0 msec (AC Input) 1/2 Cycle (DC Input), 40.0 msec (AC Input) Max. Turn-Off Time 0.5 Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ DC CONTROL (D PREFIX) 0.5 0.5 0.5 0.5 AC CONTROL ( A P R E F I X )➃ AC CONTROL (E SUFFIX) Control Voltage Range 3-32 Vdc 90-280 Vrms (60Hz) 18-36 Vrms Max. Reverse Voltage -32 Vdc --- --- Max. Turn-On Voltage 3.0 Vdc 90 Vrms 18 Vrms Min. Turn-Off Voltage 1.0 Vdc 10 Vrms 4.0 Vrms See Note ➅ 60K Ohms 9.0K Ohms 2.0 mA ➅ 2mA @ 120 Vrms, 4mA @ 240 Vrms 3mA @ 24 Vrms Nominal Input Impedance Typical Input Current © 2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ ➁ ➂ ➃ ➄ All parameters at 25˚C unless otherwise specified. Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➅ Input circuitry incorporates active current limiter. Heat sinking required, for derating curves see page 2. 24 Vac Input option, E suffix. Turn-on time for random turn-on versions is 0.02 msec (DC Control Models). FastFax Document No. 158 SERIES HA/HD. REV. 111303 PAGE 1 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series HA, HD 12-90Amp • 480 Vac - AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 8 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Terminals: AVAILABLE OPTIONS E 24 VAC Input (18-36 Vac) Example: HA4825E F Thermally Conductive Epoxy Screws and Saddle Clamps Furnished, Unmounted Faston Terminals (Up to 50 Amp Models) Example: HD4850F Input Status LED. Agencies Approval Pending Example: HD4850G Note: Control Voltage Range 4.5-32 Vdc for DC Control Models. G P Internal Overvoltage Protection. Relay Will Self Trigger Between 900-1200 Vpk. Not Suitable For Capacitive Loads. Agencies Approval Pending. Example: HD4825P -10 H Random Turn-On (AC & DC Control) Phase Controllable (DC Control) Example: HD4890-10 Heat Transfer Pad (Attached) Example: HD4890H Ordering System: Combination of the suffixes should be made in the following order: EFPG-10. Example: HA4850EFPG-10 Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. APPROVALS UL E116949 CSA LR81689 VDE 10143 UG FastFax Document No. 158 SERIES HA/HD. REV. 111303 PAGE 2 OF 3 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1 OUTPUT 8-32 TERMINAL (2 PLACES ) 2 1.87 (47.5) -4 3 1.00 (25.4) 1.80 (45.7) BASE PLATE .125 (3.2) Screw Torque Requirements: 6-32 Screws - 10 in. lbs., 8-32 and 10-32 Screws - 20in. lbs. (Screws dry without grease.) MOUNTING 6-32 TERMINAL (2 PLACES) 1.10 (27.9) .45 (11.4) HOLE/SLOT 0.17 (4.3) DIA. Fastons: Single pair (up to 25A) Double pair* (up to 50A). *Caution: User must connect to both pairs + INPUT 1 OUTPUT -4 2 + INPUT 1.00 (25.4) 1.80 (45.7) .78 (19.8) .90 (22.9) FASTON TERMINAL .250 X .032 (2 PLCS.) .87 REF. (22.2) 1.87 (47.5) BASE PLATE .125 (3.2) 2.30 (58.4) 1.70 (43.2) 2.30 (58.4) 1.70 (43.2) 3 FASTON TERMINAL .187 X .032 (2 PLCS.) .78 (19.8) .90 (22.9) All dimensions are in inches (millimeters) © 2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series HA, HD 12-90Amp • 480 Vac - AC OUTPUT CURRENT DERATING CURVES 12A 14 25A 12 30 110 5˚C/W 8 NO HEATSINK 6 115 4 120 4 6 8 10 12 40 60 5 80 20 60 80 Max Ambient Temp. [˚C] 40 60 80 90 1˚C/W 110 40 .2˚C/W .4˚C/W Power Dissipation 100 80 Base Plate Temp [˚C] .3˚C/W .5˚C/W 80 100 1ºC/W 110 40 120 120 0 40 20 Max Ambient Temp. [˚C] 90A 120 NO HEATSINK 0 20 25 120 95 Power Dissipation 110 20 50 15 .5˚C/W Base Plate Temp [˚C] 100 2˚C/W 40 10 Load Current [Arms] 90 40 30 120 75A .5˚C/W 1.5˚C/W Power Dissipation 20 Max Ambient Temp. [˚C] 120 20 110 10 0 15 30 45 60 Load Current [Arms] 75 20 40 60 80 Max Ambient Temp. [˚C] 20 40 60 80 0 Load Current [Arms] 20 40 60 80 Max Ambient Temp. [˚C] © 2003 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No. 158 SERIES HA/HD. REV. 111303 PAGE 3 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Base Plate Temp [˚C] 2 50A Load Current [Arms] 15 0 0 60 1˚C/W 2˚C/W 5 Load Current [Arms] 10 3˚C/W 20 NO HEATSINK 2 0 100 Base Plate Temp [˚C] 9˚C/W 95 1˚C/W 25 Power Dissipation Power Dissipation 10 3˚C/W Base Plate Temp [˚C] 7˚C/W Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series HA/HD60 25-125Amp • 600 Vac - AC OUTPUT • Zero Voltage and Random Turn-On Switching • Panel Mount • 1200V Blocking Capability • 600Vac - the preferred choice in Canada • Integrated Overvoltage Protection by Automatic Self Turn-On (Suffix P) HA6025 HD6025 HA6050 HD6050 HA6090 HD6090 HA60125 HD60125 OUTPUT SPECIFICATIONS ➀ Nominal Line Voltage (±10%) [Vrms] 600 600 600 600 Operating Voltage Range (47-63 Hz) [Vrms] 48-660 48-660 48-660 48-660 Max. Load Current ➂ [Arms] 25 50 90 125 Min. Load Current, [mArms] 40 40 40 150 Transient Overvoltage [Vpk] 1200 1200 1200 1200 Max. Surge Current, (16.6ms) [Apk] 250 625 1,200 1,750 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.7 1.7 1.7 1.7 Thermal Resistance Junction to Case (R θJC) [˚ C/W] 1.02 0.63 0.28 0.22 Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] 260 1,620 6,000 12,700 5 5 5 5 500 500 500 500 MODEL NUMBERS AC CONTROL D C CONTROL Featuring state-of-the-art Surface Mount Technology, these SPST-NO relays deliver proven reliability in the most demanding applications. Output consists of an SCR AC switch and is available in zero-cross, random turn-on (phase controllable) and versions with either AC or DC input (coil) control. Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. Max. Off-State Leakage Current @ Rated Voltage [mArms] ➆ Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁ Max. Turn-On Time ➄ 1/2 Cycle (DC Input), 10.0 msec (AC Input) 1/2 Cycle (DC Input), 40.0 msec (AC Input) Max. Turn-Off Time 0.5 Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ DC CONTROL (D PREFIX) 0.5 0.5 0.5 AC CONTROL (A PREFIX) ➃ AC CONTROL (E SUFFIX) Control Voltage Range 3-32 Vdc 90-280 Vrms (60Hz) 18-36 Vrms Max. Reverse Voltage -32 Vdc --- --- Max. Turn-On Voltage 3.0 Vdc 90 Vrms 18 Vrms Min. Turn-Off Voltage 1.0 Vdc 10 Vrms 4.0 Vrms See Note ➅ 60K Ohms 9.0K Ohms 2.0 mA ➅ 2mA @ 120 Vrms, 4mA @ 240 Vrms 3mA @ 24 Vrms Nominal Input Impedance Typical Input Current © 2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ All parameters at 25˚C unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 2. ➃ 24 Vac Input option, E suffix. ➄ Turn-on time for random turn-on versions is 0.02 msec (DC Control Models). ➅ Input circuitry incorporates active current limiter. ➆ No internal snubber. FastFax Document No.159 SERIES HA/HD60. Rev. 111303 PAGE 1 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series HA/HD60 25-125Amp • 600 Vac - AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 8 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Thermally Conductive Epoxy Terminals: AVAILABLE OPTIONS E 24 VAC Input (18-36 Vac) Example: HA6025E F Screws and Saddle Clamps Furnished, Unmounted MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Faston Terminals (Up to 50 Amp Models) Example: HD6050F Input Status LED. Agencies Approval Pending Example: HD6050G Note: Control Voltage Range 4.5-32Vdc for DC Control Models. G P Internal Overvoltage Protection. Relay Will Self Trigger Between 900-1200 Vpk. Not Suitable For Capacitive Loads. Agencies Approval Pending. Example: HD6025P -10 Random Turn-On (AC & DC Control) Phase Controllable (DC Control) Example: HD6090-10 H Heat Transfer Pad (Attached) Example: HD6090H Ordering System: Combination of the suffixes should be made in the following order: EFPG-10. Example: HA6050EFPG-10 1 Screw Torque Requirements: 6-32 Screws - 10 in./lbs., 8-32 and 10-32 Screws - 20in./lbs. (Screws dry without grease.) 1.10 (27.9) .45 (11.4) 8-32 TERMINAL (2 PLACES ) OUTPUT 2 1.87 (47.5) -4 + 3 INPUT 1.00 (25.4) 1.80 (45.7) BASE PLATE .125 (3.2) Fastons: Single pair (up to 25A) Double pair* (up to 50A). * Caution: User must connect to both pairs MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1 1 6-32 TERMINAL (2 PLACES) 1.10 (27.9) .45 (11.4) .78 (19.8) .90 (22.9) FASTON TERMINAL .250 X .032 (2 PLCS.) .87 REF. (22.2) OUTPUT 2 2 1.87 (47.5) 2.30 (58.4) 1.70 (43.2) 44 BASE PLATE .125 (3.2) 2.30 (58.4) 1.70 (43.2) INPUT 1.00 (25.4) 1.80 (45.7) 3 3 FASTON TERMINAL .187 X .032 (2 PLCS.) .78 (19.8) .90 (22.9) Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. All dimensions are in inches (millimeters) APPROVALS UL E116950 CSA LR81689 VDE 10143 UG FastFax Document No.159 SERIES HA/HD60. Rev. 111303 PAGE 2 OF 3 © 2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series HA/HD60 25-125Amp • 600 Vac - AC OUTPUT CURRENT DERATING CURVES 50A 25A 60 95 1˚C/W .5˚C/W 3˚C/W 2˚C/W 20 15 110 10 NO HEATSINK 5 Power Dissipation 40 100 2˚C/W 110 20 120 120 NO HEATSINK 0 0 15 20 25 20 40 60 10 80 90A .5˚C/W 30 40 50 20 80 100 1˚C/W 110 40 60 80 160 90 .2˚C/W .4˚C/W 40 Max Ambient Temp. [˚C] 125A 90 120 20 Load Current [Arms] Max Ambient Temp. [˚C] .4˚C/W Power Dissipation 10 Load Current [Arms] Base Plate Temp [˚C] 5 Power Dissipation 90 1.5˚C/W 120 .5˚C/W .2˚C/W 100 80 1˚C/W 110 40 120 0 Base Plate Temp [˚C] Power Dissipation 100 Base Plate Temp [˚C] 1˚C/W 25 Base Plate Temp [˚C] 30 120 0 20 40 60 80 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] 30 60 90 120 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] © 2003 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No.159 SERIES HA/HD60. Rev. 111303 PAGE 3 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series H12C 50-90Amp • 480 Vac • AC OUTPUT • • • • 1200 Volt Blocking Panel Mount Up to 660 Vac Zero Voltage and Random Turn-On • SCR Output • Integrated Overvoltage Protection by Automatic Self Turn-On (Suffix P) High voltage relays use IC driven circuits for switching loads up to 660 VAC. All models come with 1200 Volts blocking and are available with either AC or DC input (coil) control. Types H12CA and H12CD are snubberless (reduced leakage current). Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. M O D E L N U M B E R S DC CONTROL H12CD4850 H12CD4890 AC CONTROL H12CA4850 H12CA4890 48-660 48-660 Max. Load Current ➂ [Arms] 50 90 Min. Load Current, [mArms] 150 150 Transient Overvoltage [Vpk] 1200 1200 Max. Surge Current, (16.6ms) [Apk] 625 1200 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 Thermal Resistance Junction to Case (R θJC) [˚ C/W] .63 .28 1620 6000 Max. Off-State Leakage Current @ Rated Voltage [mArms] 1.0 1.0 Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁ 500 500 OUTPUT SPECIFICATIONS ➀ Operating Voltage (47-63 Hz) [Vrms] Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] Max. Turn-On Time ➃ 1/2 Cycle (DC Control), 10.0 msec (AC Control) 1/2 Cycle (DC Control), 40.0 msec (AC Control) Max. Turn-Off Time 0.5 Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ DC CONTROL 0.5 AC CONTROL (H12CD PREFIX) (H12CA PREFIX) Control Voltage Range 4-15 Vdc 90-140 Vrms Max. Turn-On Voltage 4.0 Vdc 90 Vrms Min. Turn-Off Voltage 1.0 Vdc 10.0 Vrms 300 Ohms 8K Ohms 15 mA @ 5 Vdc 15 mA @ 120 Vrms Nominal Input Impedance Typical Input Current © 2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ All parameters at 25˚C unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 2. ➃ Turn-on time for DC control random turn-on versions is 0.02 msec. SERIES H12C. REV. 111203 PAGE 1 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series H12C 50-90Amp • 480 Vac • AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 8 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Terminals: Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. Thermally Conductive Epoxy Screws and Saddle Clamps Furnished, Unmounted MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1 1.10 (27.9) .45 (11.4) OUTPUT 8-32 TERMINAL (2 PLACES ) 2 1.87 (47.5) -4 + INPUT 2.30 (58.4) 1.70 (43.2) 3 Available Options F Faston Terminals. (50 Amp Models Only) Example: H12CD4850F G Input Status LED. Agencies Approval Pending Example: H12CD4850G Note: Control Voltage Range 5.5-15Vdc for DC Control Models. Internal Overvoltage Protection. Relay Will Self Trigger Between 900-1200Vpk. Not Suitable For Capacitive Loads. Agencies Approval Pending Example: H12CD4850P P -10 H 1.00 (25.4) 1.80 (45.7) BASE PLATE .125 (3.2) Ordering System: Combination of the suffixes should be made in the following order: FPG-10. Example: H12CD4850FPG-10 .78 (19.8) .90 (22.9) Screw Torque Requirements: *6-32 Screws - 10 in. lbs., 8-32 and 10-32 Screws - 20in. lbs. (Screws dry without grease.) Fastons: Double pair* (50A model only). Caution: User must connect to both pairs 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Random Turn-On. Example: H12CD4850-10 Heat Transfer Pad (Attached) Example: H12CD4850H 6-32 TERMINAL (2 PLACES) 1 OUTPUT FASTON TERMINAL .250 X .032 (2 PLCS.) .87 REF. (22.2) 2 1.87 (47.5) + -- 4 BASE PLATE .125 (3.2) INPUT 1.00 (25.4) 1.80 (45.7) 2.30 (58.4) 1.70 (43.2) 3 FASTON TERMINAL .187 X .032 (2 PLCS.) .78 (19.8) .90 (22.9) All dimensions are in inches (millimeters) APPROVALS UL E116949 CSA LR81689 VDE 10143 UG SERIES H12C. Rev. 111203 PAGE 2 OF 3 © 2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series H12C 50-90Amp • 480 Vac • AC OUTPUT CURRENT DERATING CURVES 50A 90A .5˚C/W 90 100 2˚C/W 110 20 20 30 40 Load Current [Arms] 50 20 40 60 80 80 Max Ambient Temp. [˚C] 100 1˚C/W 110 40 120 120 NO HEATSINK 0 10 .2˚C/W .4˚C/W Power Dissipation 1.5˚C/W 40 .5˚C/W Base Plate Temp [˚C] 1˚C/W Power Dissipation 90 120 Base Plate Temp [˚C] 60 0 20 40 60 80 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] © 2003 CRYDOM CORP, Specifications subject to change without notice. SERIES H12C. Rev. 111203 PAGE 3 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series H12D 25-90Amp • 480 Vac - AC OUTPUT • • • • 1200 Volt Blocking Panel Mount Up to 530 Vac Zero Voltage and Random Turn-On • SCR Output • Integrated Overvoltage Protection by Automatic Self Turn-On (Suffix P) High voltage relays use IC driven circuits for switching loads up to 660 VAC. All models come with 1200 Volts blocking and are available with either AC or DC input (coil) control. Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. H12D4825 H12D4850 MODEL NUMBERS H12D4875 H12D4890 OUTPUT SPECIFICATIONS ➀ 48-530 48-530 48-530 48-530 25 50 75 90 Min. Load Current, [mArms] 150 150 150 150 Transient Overvoltage [Vpk] 1200 1200 1200 1200 Max. Surge Current, (16.6ms) [Apk] 250 625 1000 1200 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 Thermal Resistance Junction to Case (R JC) [˚C/W] Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] 1.02 .63 .31 .28 260 1620 4150 6000 10 10 10 10 500 500 500 500 Operating Voltage (47-63 Hz) [Vrms] Max. Load Current ➂ [Arms] Max. Off-State Leakage Current @ Rated Voltage [mArms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁ Max. Turn-On Time ➃ Max. Turn-Off Time 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 0.5 Power Factor (Min.) with Max. Load 0.5 0.5 0.5 INPUT SPECIFICATIONS ➀ Control Voltage Range 4-32Vdc Max. Turn-On Voltage 4.0 Vdc Min. Turn-Off Voltage 1.0 Vdc See Note 5 Nominal Input Impedance 15 mA @ 5 Vdc ➄ Typical Input Current © 2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ All parameters at 25˚ C unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 2. ➃ Turn-on time for DC control random turn-on versions is 0.02 msec. ➄ Input circuitry incorporates active current limiter. FastFax Document No.157 SERIES H12D. Rev. 111203 PAGE 1 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series H12D 25-90Amp • 480 Vac - AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 8 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Terminals: Available Options F P H Screws and Saddle Clamps Furnished, Unmounted 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Faston Terminals. (Up to 50 Amp Models) Example: H12D4850F G Thermally Conductive Epoxy 1 OUTPUT -4 + INPUT 6-32 TERMINAL (2 PLACES) .78 (19.8) .90 (22.9) Screw Torque Requirements: 6-32 Screws - 10 in. lbs., 8-32 and 10-32 Screws - 20in. lbs. (Screws dry without grease.) Fastons: Single pair (up to 25A) Double pair* (up to 50A). *Caution: User must connect to both pairs Heat Transfer Pad (Attached) Example: H12D4850H 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Ordering System: Combination of the suffixes should be made in the following order: FPG-10. Example: H12D4850FPG-10 1 OUTPUT FASTON TERMINAL .250 X .032 (2 PLCS.) .87 REF. (22.2) 2 1.87 (47.5) + -- 4 Crydom Heat Sinks offer excellent ther mal management and are perfectly matched to the load current ratings ofCrydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. FastFax Document No.157 SERIES H12D. Rev. 111203 PAGE 2 OF 3 2.30 (58.4) 1.70 (43.2) 3 1.00 (25.4) 1.80 (45.7) BASE PLATE .125 (3.2) Internal Overvoltage Protection. Relay Will Self Trigger Between 900-1200Vpk. Not Suitable For Capacitive Loads. Agencies Approval Pending. Example: H12D4850P UL E116949 CSA LR81689 VDE 10143 UG 2 1.87 (47.5) Input Status LED. Agencies Approval Pending Example: H12D4850G Note: Control Voltage Range 5.5-32 Vdc APPROVALS 8-32 TERMINAL (2 PLACES ) BASE PLATE .125 (3.2) INPUT 1.00 (25.4) 1.80 (45.7) 2.30 (58.4) 1.70 (43.2) 3 FASTON TERMINAL .187 X .032 (2 PLCS.) .78 (19.8) .90 (22.9) All dimensions are in inches (millimeters) © 2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series H12D 25-90Amp • 480 Vac - AC OUTPUT CURRENT DERATING CURVES 25A 50A 95 60 1˚C/W 2˚C/W 20 15 110 10 NO HEATSINK 5 .5˚C/W 90 1.5˚C/W Power Dissipation 40 100 2˚C/W 110 20 120 120 NO HEATSINK 0 5 10 15 20 25 Load Current [Arms] 20 40 60 0 80 10 Max Ambient Temp. [˚C] 20 30 40 50 Load Current [Arms] 20 40 60 90A 75A 90 120 120 100 80 1˚C/W 110 40 .2˚C/W .4˚C/W Power Dissipation 95 .3˚C/W .5˚C/W Base Plate Temp [˚C] .5˚C/W Power Dissipation 80 Max Ambient Temp. [˚C] 80 100 1˚C/W 110 40 Base Plate Temp [˚C] Power Dissipation 100 3˚C/W Base Plate Temp [˚C] 1˚C/W 25 Base Plate Temp [˚C] 30 120 120 0 0 15 30 45 60 Load Current [Arms] 75 20 40 60 80 Max Ambient Temp. [˚C] 20 40 60 80 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] © 2003 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No.157 SERIES H12D. Rev. 111203 PAGE 3 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series H12WD 25-125Amp • 480 Vac - AC OUTPUT • 1200 Volt Blocking • Panel Mount • Up to 660 Vac • Zero Voltage and Random Turn-On • SCR Output • Integrated Overvoltage Protection by Automatic Self Turn-On (Suffix P) MODEL NUMBERS H12WD4825 H12WD4850 48-660 48-660 High voltage relays use IC driven circuits for switching loads up to 660 VAC. All models come with 1200 Volts blocking. Type H12WD is a snubberless (reduced leakage current). Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. H12WD4875 H12WD4890 ➅ H12WD48125 OUTPUT SPECIFICATIONS ➀ Operating Voltage (47-63 Hz) [Vrms] 48-660 48-660 48-660 Max. Load Current ➂ [Arms] 25 50 75 90 125 Min. Load Current, [mArms] 150 150 150 150 150 Transient Overvoltage [Vpk] 1200 1200 1200 1200 1200 Max. Surge Current, (16.6ms) [Apk] 250 625 1000 1200 1750 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 1.7 Thermal Resistance Junction to Case (R θJC) [˚C/W] 1.02 .63 .31 .28 .22 Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] 260 1620 4150 6000 12700 Max. Off-State Leakage Current @ Rated Voltage [mArms] 1.0 1.0 1.0 1.0 1.0 Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁ 500 500 500 500 500 Max. Turn-On Time ➃ 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle Max. Turn-Off Time 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 0.5 0.5 0.5 Power Factor (Min.) with Max. Load 0.5 0.5 INPUT SPECIFICATIONS ➀ Control Voltage Range 4-32 Vdc Max. Turn-On Voltage 4.0 Vdc Min. Turn-Off Voltage 1.0 Vdc Nominal Input Impedance See Note 5 15 mA @ 5 Vdc ➄ Typical Input Current © 2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ All parameters at 25˚C unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 2. ➃ Turn-on time for DC control random turn-on versions is 0.02 msec. ➄ Input circuitry incorporates active current limiter. Compliant only. ➅ SERIES H12WD. Rev. 111203 PAGE 1 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series H12WD 25-125Amp • 480 Vac - AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 8 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Terminals: Thermally Conductive Epoxy Screws and Saddle Clamps Furnished, Unmounted 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. OUTPUT 1 -- G P -10 H INPUT 6-32 TERMINAL (2 PLACES) .78 (19.8) .90 (22.9) Screw Torque Requirements: 6-32 Screws - 10 in. lbs., 8-32 and 10-32 Screws - 20in. lbs. (Screws dry without grease.) Internal Overvoltage Protection. Relay Will Self Trigger Between 900-1200Vpk. Not Suitable For Capacitive Loads. Agencies Approval Pending. Example: H12WD4850P Fastons: Single pair (up to 25A) Double pair* (up to 50A). *Caution: User must connect to both pairs 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1 OUTPUT FASTON TERMINAL .250 X .032 (2 PLCS.) .87 REF. (22.2) 2 1.87 (47.5) + -- Ordering System: Combination of the suffixes should be made in the following order: FPG-10. Example: H12WD4850FPG-10 2.30 (58.4) 1.70 (43.2) 3 1.00 (25.4) 1.80 (45.7) BASE PLATE .125 (3.2) Input Status LED. Agencies Approval Pending Example: H12WD4850G Note: Control Voltage Range 5.5-32 Vdc Heat Transfer Pad (Attached) Example: H12WD4850H + 4 Faston Terminals. (Up to 50 Amp Models) Example: H12WD4850F Random Turn-On. Example: H12WD4850-10 2 1.87 (47.5) Available Options F 8-32 TERMINAL (2 PLACES ) 4 BASE PLATE .125 (3.2) INPUT 1.00 (25.4) 1.80 (45.7) 2.30 (58.4) 1.70 (43.2) 3 FASTON TERMINAL .187 X .032 (2 PLCS.) .78 (19.8) .90 (22.9) All dimensions are in inches (millimeters) © 2003 CRYDOM CORP, Specifications subject to change without notice. APPROVALS UL E116949 CSA LR81689 VDE 10143 UG SERIES H12WD. Rev. 111203 PAGE 2 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series H12WD 25-125Amp • 480 Vac - AC OUTPUT CURRENT DERATING CURVES 25A 50A 95 60 1˚C/W 3˚C/W 2˚C/W 20 15 110 10 NO HEATSINK 5 .5˚C/W 90 1.5˚C/W Power Dissipation 40 100 2˚C/W 110 20 120 120 NO HEATSINK 0 5 10 15 20 25 Load Current [Arms] 20 40 60 0 80 10 Max Ambient Temp. [˚C] 20 30 40 50 Load Current [Arms] 20 40 60 90A 75A 90 120 120 100 80 1˚C/W 110 40 .2˚C/W .4˚C/W Power Dissipation 95 .3˚C/W .5˚C/W Base Plate Temp [˚C] .5˚C/W Power Dissipation 80 Max Ambient Temp. [˚C] 80 100 1˚C/W 110 40 Base Plate Temp [˚C] Power Dissipation 100 Base Plate Temp [˚C] 1˚C/W 25 Base Plate Temp [˚C] 30 120 120 0 0 15 30 45 60 Load Current [Arms] 75 20 40 60 20 80 40 60 80 0 Load Current [Arms] Max Ambient Temp. [˚C] 20 40 60 80 Max Ambient Temp. [˚C] 125A 160 Power Dissipation .5˚C/W .2˚C/W 100 80 1˚C/W 110 40 Base Plate Temp [˚C] 90 .4˚C/W 120 120 0 30 60 90 120 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] © 2003 CRYDOM CORP, Specifications subject to change without notice. SERIES H12WD. Rev. 111203 PAGE 3 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series 1-DC 7-40Amp • 0-500 Vdc - DC OUTPUT DC output relays feature MOSFET tech nology for low on-state resistance, assuring easy paralleling and switching capabilities to 40 amps at 100 Vdc. Lower current models are also available to 500 Vdc. All models come in Crydom's standard panel-mount package. Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. • M OSFET Output • Low On-State Resistance • Paralleling Capability for Higher Currents • Panel M ount OUTPUT SPECIFICATIONS ➀ MODEL NUMBERS Operating Voltage Range [Vdc] Max. Load Current ➂ [Adc] D1D07 D1D12 D1D20 D1D40 D2D07 D2D12 D4D07 D4D12 D5D07 D5D10 0-100 0-200 0-200 0-400 0-400 0-500 0-500 0-100 0-100 0-100 7 12 20 40 7 12 7 12 7 10 Min. Load Current [mA] 20 20 20 20 20 20 20 20 20 20 Max. Surge Current, [Adc] (10Msec) 15 28 42 106 22 27 17 36 19 29 Max. On-State Voltage Drop @ Rated Current [Vdc] 2.0 1.6 2.1 2.1 2.0 2.8 4.2 4.2 5.7 5.5 Thermal Resistance Junction to Case [RθJC] C/W 2.2 1.34 1.06 0.83 1.5 1.06 1.06 0.8 1.0 0.8 Max On-state Resistance @ Rated Current (RDS-ON) [Ohms] .29 .13 .10 .05 .29 .23 .6 .35 .8 .55 Max. Off-State Leakage Current @ Rated Voltage [mA] 0.1 0.2 0.3 0.3 0.1 0.3 0.3 0.3 0.2 0.3 Max. Turn-On Time [µsec] 100 100 100 100 100 100 100 100 100 100 Max. Turn-Off Time [msec] 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 INPUT SPECIFICATIONS ➀ DC CONTROL 3.5-32 Vdc Control Voltage Range Maximum Turn-On Voltage 3.5 Vdc Minimum Turn-Off Voltage 1.0 Vdc See Note 4 Nominal Input Impedance 1.6 mA (5 Vdc), 28 mA (32 Vdc) ➃ Maximum Input Current GENERAL NOTES ©2003 CRYDOM CORP, Specifications subject to change without notice. ➀ All parameters at 25ºC unless otherwise specified. ➁ Dielectric strength and insulation resistance are measured between input and output. ➂ Heat sinking required, for derating curves see page 3. ➃ Input circuitry incorporates active current limiter. FastFax Document No. 164 SERIES 1DC. Rev. 111003 PAGE 1 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series 1-DC 7-40Amp • 0-500 Vdc - DC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength 60Hz 2500 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 50 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -20 to 80ºC Ambient Storage Temperature Range -20 to 125ºC M ECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Thermally Conductive Epoxy Terminals: MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Screws and Saddle Clamps Furnished, Unmounted M AXIM UM SURGE vs . DURATION 1.10 (27.9) .45 (11.4) 8-32 TERMINAL (2 PLACES ) 60 D1D20 -1.87 (47.5) + OUTPUT 1 -- 2.30 (58.4) 1.70 (43.2) 2 4 MAX. SURGE CURRENT (Amps) 55 3 + INPUT 1.00 (25.4) 1.80 (45.7) 6-32 TERMINAL (2 PLACES) 50 45 40 D1D12 D2D12 35 30 25 20 15 D2D07 D1D07 10 5 .78 (19.8) .90 (22.9) 2 3 4 5 6 8 10 2 3 4 5 6 8102 2 3 4 5 6 8103 SURGE DURATION (msec) 2 3 4 5 6 8104 2 3 4 5 6 8104 2 3 4 5 6 8104 All dimensions are in inches (millimeters) 60 Input and output polarity must be observed. Inductive loads must be diode suppressed. 4 (–) 55 MAX. SURGE CURRENT (Amps) Screw Torque Requirements: 6-32 Screws - 10 in. lbs., 8-32 and 10-32 Screws - 20in. lbs. (Screws dry without grease.) 50 D4D12 45 40 35 D5D10 30 25 D4D07 20 D5D07 15 10 5 2 1 (–) 3 4 5 6 8 10 2 3 4 5 6 8102 2 3 4 5 6 8103 SURGE DURATION (msec) 3 4 5 6 8 10 2 3 (+) 2 (+) (–) (+) Transient Protection All loads are inductive, even ones that are not so labeled. An inductive load will produce harmful transient voltages when it is turned off. The more perfect the switch, the larger the transient voltages; the MOSFET output is so nearly an ideal switch that the transient voltages produced by seemingly "non-inductive" loads can cause damage if not suppressed. Diodes should be fast recovery type with PIV rated greater than supply voltage. 200 MAX. SURGE CURRENT (Amps) SSR OUTPUT DC CONTROL SOURCE INPUT LOAD D1D40 150 100 50 2 3 4 5 6 8102 2 3 4 5 6 8103 SURGE DURATION (msec) ©2003 CRYDOM CORP, Specifications subject to change without notice. APPROVALS UL E116950 (100 Volt Models Only) FastFax Document No. 164 SERIES 1DC. Rev. 111003 PAGE 2 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series 1-DC 7-40Amp • 0-500 Vdc - DC OUTPUT Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. CURRENT DERATING CURVES D1D07 - 7A D1D12 - 12A 4ºC/W 12 6ºC/W 8 NO HEATSINK 4 120 5 6 20 7 Load Current [Adc] 40 60 80 2 Max Ambient Temp. [ºC] 4 6 8 Load Current [Adc] D1D40 - 40A 20 40 60 80 Max Ambient Temp. [ºC] 100 2ºC/W 120 140 0 24 32 40 20 Load Current [Adc] 40 60 2ºC/W 100 4ºC/W 12 6ºC/W 9 110 6 NO HEATSINK 2 3 20 4ºC/W 110 6ºC/W 10 NO HEATSINK 120 5 6 7 20 40 60 60 2ºC/W 110 6ºC/W 10 2 4 6 100 110 4ºC/W 20 8 10 12 20 2ºC/W 30 105 4ºC/W 20 10 120 NO HEATSINK 0 2 4 6 8 Load Current [Adc] FastFax Document No. 164 SERIES 1DC. Rev. 111003 PAGE 3 OF 3 10 20 40 60 80 Max Ambient Temp. [ºC] 60 80 40 60 85 1ºC/W 30 2ºC/W 20 4ºC/W 100 80 Max Ambient Temp. [ºC] 110 6ºC/W 10 120 NO HEATSINK 0 1 2 3 4 5 6 7 Load Current [Adc] Base Plate Temp [ºC] 90 40 40 40 120 NO HEATSINK 6 20 Max Ambient Temp. [ºC] D5D07 - 7A 30 4 10 12 8 Load Current [Adc] 0.5ºC/W 1ºC/W 120 NO HEATSINK 20 40 60 80 Max Ambient Temp. [ºC] ©2003 CRYDOM CORP, Specifications subject to change without notice. 75 50 100 4ºC/W 20 80 1ºC/W Load Current [Adc] D5D10 - 10A 60 Power Dissipation 40 2ºC/W 2 80 Max Ambient Temp. [ºC] 120 80 Max Ambient Temp. [ºC] 30 Max Ambient Temp. [ºC] 40 0 4 60 1ºC/W 85 0.5ºC/W 10 0 3 20 50 Power Dissipation 100 2 6 7 60 Base Plate Temp [ºC] Power Dissipation 30 40 85 D4D12 - 12A D4D07 - 7A Load Current [Adc] 5 4 Load Current [Adc] 1ºC/W 20 0 Max Ambient Temp. [ºC] 2ºC/W 20 120 1 85 16 40 0 80 40 1 12 D2D12 - 12A 3 NO HEATSINK 16 8 Load Current [Adc] 95 15 Power Dissipation 1ºC/W 1.5ºC/W Base Plate Temp [ºC] 60 8 4 18 80 0.2ºC/W 0.5ºC/W 110 6ºC/W D2D07 - 7A 90 30 10 12 Power Dissipation 4 Power Dissipation 3 15 NO HEATSINK Base Plate Temp [ºC] 2 100 4ºC/W 0 Base Plate Temp [ºC] 1 90 2ºC/W 120 0 0 Power Dissipation 110 1ºC/W 30 Base Plate Temp [ºC] NO HEATSINK 4 100 16 Base Plate Temp [ºC] 110 2ºC/W Base Plate Temp [ºC] 6ºC/W 8 80 45 Power Dissipation 100 90 20 Power Dissipation 4ºC/W Base Plate Temp [ºC] Power Dissipation 2ºC/W 12 D1D20 - 20A 24 90 Base Plate Temp [ºC] 16 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Series 1-DCL 7-40Amp • 0-500 Vdc - DC OUTPUT • MOSFET Output • Low On-State Resistance • Paralleling Capability for Higher Currents • Panel Mount • Optically Coupled DC output relays feature MOSFET technology for low on-state resistance, assuring easy paralleling and switching capabilities to 40 amps at 100 Vdc. Lower current models are also available to 500 Vdc. All models come in Crydom's standard panel-mount package. Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. OUTPUT SPECIFICATIONS➀ M O D E L N U M B E R S D1D07L D1D12L D1D20L D1D40L D2D07L D2D12L D4D07L D4D12L D5D07L D5D10L Operating Voltage Range [Vdc] ➂ [Adc] 0-100 0-100 0-100 0-100 0-200 0-200 0-400 0-400 0-500 0-500 7 12 20 40 7 12 7 12 7 10 Min. Load Current [mA] 20 20 20 20 20 20 20 20 20 20 Max. Surge Current, [Adc] (10msec) 15 28 42 106 22 27 17 36 19 29 Max. On-State Voltage Drop @ Rated Current [Vdc] 2.0 1.6 2.1 2.1 2.0 2.8 4.2 4.2 5.7 5.5 Thermal Resistance Junction to Case [R θJC ]˚C/W 2.2 1.34 1.06 0.83 1.5 1.06 1.06 0.8 1.0 0.8 Max On-state Resistance @ Rated Current (R DS-ON ) [Ohms] .29 .13 .10 .05 .29 .23 .6 .35 .8 .55 Max. Off-State Leakage Current @ Rated Voltage [mA] 0.1 0.2 0.3 0.3 0.1 0.3 0.3 0.3 0.2 0.3 Max. Turn-On Time [msec] 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Max. Turn-Off Time [msec] 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Max. Load Current INPUT SPECIFICATIONS ➀ DC CONTROL 3.5-32 Vdc Control Voltage Range Maximum Turn-On Voltage 3.5 Vdc Minimum Turn-Off Voltage 1.0 Vdc Nominal Input Impedance See Note 4 20mA ➃ Typical Input Current GENERAL NOTES © 2003 CRYDOM CORP, Specifications subject to change without notice. ➀ All parameters at 25˚C unless otherwise specified. ➁ Dielectric strength and insulation resistance are measured between input and output. ➂ Heat sinking required, for derating curves see page 3. ➃ Input circuitry incorporates active current limiter. FastFax Document No. SERIES 1DCL. Rev. 102704 PAGE 1 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Series 1-DCL 7-40Amp • 0-500 Vdc - DC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength 60Hz 2500 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 50 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Thermally Conductive Epoxy Terminals: MAXIMUM SURGE vs. DURATION 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Screws and Saddle Clamps Furnished, Unmounted 8-32 TERMINAL (2 PLACES ) 60 D1D20 -1.87 (47.5) + OUTPUT 1 2.30 (58.4) 1.70 (43.2) 2 4 3 -- MAX. SURGE CURRENT (Amps) 55 + INPUT 1.00 (25.4) 1.80 (45.7) 6-32 TERMINAL (2 PLACES) 50 45 40 D1D12 D2D12 35 30 25 20 15 D2D07 D1D07 10 5 .78 (19.8) .90 (22.9) 2 3 4 5 6 8 10 2 3 4 5 6 8102 2 3 4 5 6 8103 SURGE DURATION (msec) 2 3 4 5 6 8104 2 3 4 5 6 8104 2 3 4 5 6 8104 All dimensions are in inches (millimeters) 60 Input and output polarity must be observed. Inductive loads must be diode suppressed. 4 (–) 55 MAX. SURGE CURRENT (Amps) Screw Torque Requirements:6-32 Screws - 10 in. lbs., 8-32 and 10-32 Screws - 20in. lbs. (Screws dry without grease.) 1 (–) 50 D4D12 45 40 35 D5D10 30 25 D4D07 20 D5D07 15 10 5 LOAD 3 (+) 2 (+) 3 4 5 6 8 10 2 3 4 5 6 8102 2 3 4 5 6 8103 SURGE DURATION (msec) 3 4 5 6 8 10 2 (–) (+) Transient Protection All loads are inductive, even ones that are not so labeled. An inductive load will produce harmful transient voltages when it is turned off. The more perfect the switch, the larger the transient voltages; the MOSFET output is so nearly an ideal switch that the transient voltages produced by seemingly "non-inductive" loads can cause damage if not suppressed. Diodes should be fast recovery type with PIV rated greater than supply voltage. MAX. SURGE CURRENT (Amps) SSR OUTPUT INPUT 2 DC CONTROL SOURCE 200 D1D40 150 100 50 2 3 4 5 6 8102 2 3 4 5 6 8103 SURGE DURATION (msec) © 2003 CRYDOM CORP, Specifications subject to change without notice. APPROVALS UL E116950 (100 Volt Models Only) FastFax Document No. SERIES 1DCL. Rev. 102704 PAGE 2 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Series 1-DCL 7-40Amp • 0-500 Vdc - DC OUTPUT Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. CURRENT DERATING CURVES D1D07 - 7A D1D12 - 12A NO HEATSINK 4˚C/W 12 6˚C/W 8 NO HEATSINK 4 120 3 4 5 6 20 7 Load Current [Adc] 40 60 80 2 Max Ambient Temp. [˚C] 4 6 8 10 12 Load Current [Adc] D1D40 - 40A 20 40 60 80 100 2˚C/W 120 2˚C/W 100 4˚C/W 12 6˚C/W 9 110 6 NO HEATSINK 20 Load Current [Adc] 40 60 80 2 3 6 7 20 40 60 4˚C/W 110 6˚C/W 10 NO HEATSINK 120 4 5 6 7 110 6˚C/W 10 2 4 6 20 40 60 100 2˚C/W 30 110 4˚C/W 20 85 1˚C/W 30 2˚C/W 20 4˚C/W 100 30 105 4˚C/W 20 10 2 4 6 8 Load Current [Adc] FastFax Document No. SERIES 1DCL. Rev. 102704 PAGE 3 OF 3 10 20 40 60 80 Max Ambient Temp. [˚C] 120 NO HEATSINK 6 8 10 12 20 40 60 80 Max Ambient Temp. [˚C] 1 2 3 4 5 Load Current [Adc] 6 7 20 40 60 80 Max Ambient Temp. [˚C] 120 NO HEATSINK 0 110 6˚C/W 10 Base Plate Temp [˚C] 90 2˚C/W 80 40 0.5˚C/W 40 60 © 2003 CRYDOM CORP, Specifications subject to change without notice. 75 1˚C/W 40 0 4 Load Current [Adc] D5D10 - 10A 60 20 Max Ambient Temp. [˚C] 120 NO HEATSINK 2 80 Max Ambient Temp. [˚C] 50 120 D5D07 - 7A 1˚C/W 40 10 12 8 Load Current [Adc] 0 3 100 4˚C/W NO HEATSINK 85 0.5˚C/W 10 0 2 2˚C/W 20 80 50 Power Dissipation 100 Base Plate Temp [˚C] 1˚C/W 30 Load Current [Adc] 30 Max Ambient Temp. [˚C] 60 85 1 120 80 85 D4D12 - 12A D4D07 - 7A Power Dissipation 5 4 Load Current [Adc] 40 20 60 0 1 Max Ambient Temp. [˚C] 2˚C/W 40 1˚C/W Power Dissipation 40 20 Max Ambient Temp. [˚C] 120 Base Plate Temp [˚C] 32 20 40 0 24 16 140 0 16 12 D2D12 - 12A 3 8 8 Load Current [Adc] 95 15 Power Dissipation 1˚C/W 1.5˚C/W Base Plate Temp [˚C] 60 NO HEATSINK Power Dissipation 4 Max Ambient Temp. [˚C] 18 80 0.2˚C/W 0.5˚C/W 110 6˚C/W D2D07 - 7A 90 30 15 NO HEATSINK Power Dissipation 2 100 4˚C/W 0 Base Plate Temp [˚C] 1 90 2˚C/W 120 0 0 Power Dissipation 110 1˚C/W 30 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Base Plate Temp [˚C] 4 100 16 Base Plate Temp [˚C] 110 2˚C/W Base Plate Temp [˚C] 6˚C/W 8 80 45 Power Dissipation 100 90 20 Power Dissipation 4˚C/W Base Plate Temp [˚C] Power Dissipation 2˚C/W 12 D1D20 - 20A 24 90 Base Plate Temp [˚C] 16 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series D06D 60-100Amp • 0-60 Vdc • DC OUTPUT • MOSFET Output • Low On-State Resistance • High Current Ratings • Panel Mount DC output relays feature MOSFET tech-nology for low on-state resistance, assuring easy paralleling and switching capabilities to 100 amps at 60 Vdc. Lower current models are also available to 500 Vdc. All models come in Crydom's standard panel-mount package. Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. OUTPUT SPECIFICATIONS➀ MODEL NUMBERS D06D60 D06D80 D06D100 0-60 0-60 0-60 60 80 100 5 5 5 Max. Surge Current, [Adc] (10msec) 180 220 270 Max. On-State Voltage Drop @ Rated Current [Vdc] 0.6 0.7 0.5 Thermal Resistance Junction to Case (R θJC) [C/W] 0.6 0.47 0.32 Max On-state Resistance @ Rated Current (R DS-ON) [Ohms] .010 .008 .005 Max. Off-State Leakage Current @ Rated Voltage [mA] 0.1 0.2 0.3 Max. Turn-On Time [µsec] 300 300 300 Max. Turn-Off Time [msec] 1.0 1.0 1.0 Operating Voltage Range [Vdc] Max. Load Current ➂ [Adc] Min. Load Current [mA] INPUT SPECIFICATIONS➀ DC CONTROL 3.5-32 Vdc Control Voltage Range Maximum Turn-On Voltage 3.5 Vdc Minimum Turn-Off Voltage 1.0 Vdc Nominal Input Impedance See Note 4 1.6 mA (5 Vdc), 28 mA (32 Vdc) ➃ Maximum Input Current GENERAL NOTES ©2003 CRYDOM CORP, Specifications subject to change without notice. ➀ All parameters at 25º C unless otherwise specified. ➁ Dielectric strength and insulation resistance are measured between input and output. ➂ Heat sinking required, for derating curves see page 2. ➃ Input circuitry incorporates active current limiter. FastFax Document No. 450 SERIES D06D. Rev. 111203 PAGE 1 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series D06D 60-100Amp • 0-60 Vdc • DC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength 60Hz 2500 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 50 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -30 to 80ºC Ambient Storage Temperature Range -40 to 125ºC MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Thermally Conductive Epoxy Terminals: 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Screws and Saddle Clamps Furnished, Unmounted Input and output polarity must be observed. Inductive loads must be diode suppressed. 8-32 TERMINAL (2 PLACES ) 4 (–) LOAD + 2 -- + 4 2.30 (58.4) 1.70 (43.2) DC CONTROL SOURCE INPUT OUTPUT 1 SSR (–) 3 INPUT 3 (+) 1.00 (25.4) 1.80 (45.7) BASE PLATE .125 (3.2) OUTPUT -1.87 (47.5) 1 (–) 6-32 TERMINAL (2 PLACES) (+) 2 (+) Transient Protection .78 (19.8) .90 (22.9) All loads are inductive, even ones that are not so labeled. An inductive load will produce harmful transient voltages when it is turned off. The more perfect the switch, the larger the transient voltages; the MOSFET output is so nearly an ideal switch that the transient voltages produced by seemingly "non-inductive" loads can cause damage if not suppressed. Diodes should be fast recovery type with PIV rated greater than supply voltage. All dimensions are in inches (millimeters) Screw Torque Requirements: 6-32 Screws - 10 in./lbs., 8-32 and 10-32 Screws - 20in./lbs. (Screws dry without grease.) D06D100 D06D80 100 110 20 No Heatsink 10 120 50 100 2˚C /W 40 30 3˚C /W 20 No Heatsi nk 10 110 120 Power Dissipation [W] 90 Base Plate Temperature [˚C] 3˚C /W Power Dissipation [W] 30 100 Base Plate Temperature [˚C] 2˚C /W 40 1˚ C /W 70 60 /W ˚C 0.5 90 50 70 60 /W C 1˚ 80 /W C 5˚ 0. /W C 5˚ 0. 1˚ C /W 60 80 80 90 100 50 2˚ C/ W 40 30 110 3˚C /W 20 No Heats ink 10 120 0 0 0 60 40 20 Load Current [Arms] 60 80 40 20 Ambient Temperature [˚C] APPROVALS Pending FastFax Document No. 450 SERIES D06D. Rev. 111203 PAGE 2 OF 2 0 60 40 20 Load Current [Arms] 80 80 40 20 60 Ambient Temperature [˚C] 60 100 20 40 80 40 60 20 Load Current [Arms] Ambient Temperature [˚C] 80 ©2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Base Plate Temperature [˚C] 90 80 70 Power Dissipation [W] 100 90 D06D60 80 80 110 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series DC60 3-7Amp • 60 Vdc - DC OUTPUT • Cost Effective • Industry Standard Package • AC or DC Control • Panel M ount MODEL NUMBERS Bipolar transistor outputs are available in 3, 5 and 7 amp ratings. Cost-effective relays offer 4000 Volt isolation and come in Crydom's standard panelmount package. Manufactured in Crydom's ISO 9001 Certified facility for optimum product performance and reliability. DC CONTROL A C CONTROL DC60S3 DC60S5 DC60S7 DC60SA3 DC60SA5 DC60SA7 Operating Voltage Range [Vdc] 3-60 3-60 3-60 3-60 3-60 3-60 Load Current Range➁ [Adc] .02-3 .02-5 .02-7 .02-3 .02-5 .02-7 6 10 14 6 10 14 Max. On-State Voltage Drop @ Rated Current [Vdc] 1.3 1.5 1.7 1.3 1.5 1.7 Thermal Resistance Junction to Case (R¯JC ) [ûC/W] 2.2 2.2 2.2 2.2 2.2 2.2 Max. Off-State Leakage Current @ Rated Voltage [mA] 0.1 0.1 0.1 0.1 0.1 0.1 Max. Turn-On Time [msec] 0.1 0.1 0.1 10 10 10 Max. Turn-Off Time [msec] 0.3 0.3 0.3 40 40 40 OUTPUT SPECIFICATIONS ➀ Max. Surge Current, (1 sec) [Adc] INPUT SPECIFICATIONS ➀ DC CONTROL AC CONTROL Control Voltage Range 3.5-32 Vdc 90-280 Vrms Max. Turn-On Voltage 3.5 Vdc 90 Vrms Min. Turn-Off Voltage 1.0 Vdc 10 Vrms 1500 Ohms 60K Ohms 2.2mA @ 5 Vdc 2mA @ 120 Vrms, 4mA @ 240 Vrms Nominal Input Impedence Typical Input Current GENERAL NOTES ➀ ➁ ©2003 CRYDOM CORP, Specifications subject to change without notice. All parameters at 25˚C unless otherwise specified. Heat sinking required, for derating curves see page 2. FastFax Document No. 163 SERIES DC60. Rev. 111203 PAGE 1 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series DC60 3-7Amp • 60 Vdc - DC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz (input/output/base) 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 8 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -30 to 80˚C Ambient Storage Temperature Range -30 to 125˚C M ECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Thermally Conductive Epoxy Terminals: 4 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Input and output polarity must be observed. Inductive loads must be diode suppressed. 8-32 TERMINAL (2 PLACES ) All dimensions are in inches (millimeters) 1 (+) INPUT LOAD OUTPUT AC CONTROL M ODELS PIN 3: AC CONTROL PIN 4: AC CONTROL DC CONTROL M ODELS PIN 3 : + DC CONTROL PIN 4: -- DC CONTROL Screws and Saddle Clamps Furnished, Unmounted SSR 3 + 1.87 (47.5) (+) (Ð) 2 (--) -- OUTPUT 1 2 4 3 -- 2.30 (58.4) 1.70 (43.2) Screw Torque Requirements : 6-32 Screws - 10 in. lbs., 8-32 and 10-32 Screws - 20in. lbs. (Screws dry without grease.) + INPUT Transient Protection All loads are inductive, even ones that are not so labeled. An inductive load will produce harmful transient voltages when it is turned off. Diodes should be fast recovery type with PIV rated greater than supply voltage. 1.00 (25.4) 1.80 (45.7) 6-32 TERMINAL (2 PLACES) CURRENT DERATING CURVES 3A 5A 12 105 NO HEAT SINK 110 115 4 Power Dissipation 7.5˚C/W 8 2˚C/W Base Plate Temp [˚C] Power Dissipation 100 7.5˚C/W 5˚C/W 100 105 8 NO HEAT SINK 110 115 4 120 Base Plate Temp [˚C] 12 .78 (19.8) .90 (22.9) 120 0 0 1 1.5 2 Load Current [Arms] 2.5 3 20 40 60 80 100 1 Max Ambient Temp. [˚C] 2 3 4 5 Load Current [Arms] 20 40 60 80 100 Max Ambient Temp. [˚C] 7A 7.5˚C/W 5˚C/W 100 105 8 NO HEAT SINK 110 115 4 Base Plate Temp [˚C] 2˚C/W Power Dissipation Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom's Heat Sink specification sheet for all the details. 12 120 0 1 2 3 4 5 Load Current [Arms] 6 7 20 40 60 80 100 Max Ambient Temp. [˚C] ©2003 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No. 163 SERIES DC60. Rev. 111203 PAGE 2 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series DSD, DLD Time Delay Relay • 10-50 Amp • DC Control, AC Output • External Adjustment • Industry Standard Package • Zero Voltage Turn-On • Panel Mount MODEL NUMBERS These “on-operate” (pull-in) time-delay solid state relays are housed in a single industry standard package. AC output is controlled by a DC input and has an externally adjustable time delay. Choices include models with two timedelay ranges. Manufactured in Crydom''s ISO 9001 Certified facility for optimum product performance and reliability. DSD2410 DSD2425 DSD2450 DLD2410 DLD2425 DLD2450 48-280 48-280 48-280 48-280 48-280 48-280 .04-10 .04-25 .04-50 .04-10 .04-25 .04-50 Transient Overvoltage [Vpk] 600 600 600 600 600 600 Max. Surge Current, (16.6ms) [Apk] 120 250 625 120 250 625 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 1.6 1.6 OUTPUT SPECIFICATIONS➀ Operating Voltage Range (47-63 Hz) [Vrms] ➂ [Arms] Load Current Range Thermal Resistance Junction to Case [R θJC] 1.48 1.02 0.63 1.48 1.02 0.63 Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] 60 260 1620 60 260 1620 Max. Off-State Leakage Current @ Rated Voltage [mArms] 10 10 10 10 10 10 500 500 500 500 500 500 Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] Max. Turn-On Time ➁ ➃ Adjustable, See Table Max. Turn-Off Time Max. Reset Time [µsec] ➄ 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle 100 100 100 100 100 100 0.5 0.5 0.5 0.5 0.5 0.5 Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ Control Voltage Range 3.5-15Vdc Max. Turn-On Voltage 3.5 Vdc Min. Turn-Off Voltage 1.0 Vdc Min. Input Impedance 1500 Ohms Typical Input Current TYPICAL TURN-ON DELAY ➀ DC CONTROL 3.4mA @ 5 Vdc, 11.4mA @ 15Vdc RESISTOR O (Short) 10K Ω 100KΩ 470KΩ 1.0MΩ ➃ TIME (DSD) TIME (DLD) 0.10 sec 0.19 sec 0.94 sec 4.0 sec 8.3 sec 1.6 sec 3.1 sec 15 sec 64 sec 133 sec © 2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ All parameters at 25˚C unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 2. ➃ Timing Resistor may be as high as 10M Ohm with performance dependent on resistor quality. ➄ Before and after time-out. FastFax Document No. 201 DSD,DLD. Rev.111203 PAGE 1 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series DSD, DLD Time Delay Relay • 10-50 Amp GENERAL SPECIFICATIONS Dielectric Strength, Input section/output/base 4000 Vrms 1010 Insulation Resistance @ 500Vdc Ambient Operating Temperature Range -30 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (43g) Encapsulation: Thermally Conductive Epoxy Terminals: Screws and Saddle Clamps Furnished, Unmounted WIRING DIAGRAM 1.10 (27.9) .45 (11.4) ~ 1 OUTPUT 8-32 TERMINAL (2 PLACES ) 2 2.30 (58.4) 1.70 (43.2) 1.87 (47.5) 4A 4B 3B 3A INPUT -- Timing Resistor .250 (6.35) 1.00 (25.4) 1.80 (45.7) + DC CONTROL .78 (19.8) .87 (22.2) FASTON TERMINAL .187 X .032 4 PLCS. All dimensions are in inches (millimeters) CURRENT DERATING CURVES 25A 3°C/W 120 100 3°C/W 2°C/W 20 15 110 10 NO HEATSINK 5 2 4 6 8 Load Current [Arms] 10 20 40 60 80 Max Ambient Temp. [°C] 1°C/W .5°C/W 40 5 10 15 20 Load Current [Arms] 25 20 40 60 80 Max Ambient Temp. [°C] 100 2°C/W 110 20 120 0 90 1.5°C/W Power Dissipation NO HEATSINK 0 60 Base Plate Temp [°C] 115 25 Power Dissipation Power Dissipation 8 4 95 1°C/W 5°C/W 110 Base Plate Temp [°C] 7°C/W 9°C/W 50A 30 Base Plate Temp [°C] 10A 12 120 NO HEATSINK 0 10 20 30 40 Load Current [Arms] 50 20 40 60 80 Max Ambient Temp. [°C] © 2003 CRYDOM CORP, Specifications subject to change without notice. APPROVALS UL E116949 FastFax Document No. 201 DSD,DLD. Rev.111203 PAGE 2 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series CS 10-90Amp • 120/240 Vac • AC OUTPUT • Low Leakage • SCR Output • Panel Mount • Zero and Random Voltage Switching • Internal Overvoltage Protection Available MODEL NUMBERS The Series CS has an SCR AC switch output featuring low off-state leakage (1mA, snubberless), zero and random voltage switching and a broadened operating range (24-280Vac). This wide range permits optimum performance at both120Vac and 240Vac line voltages. Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. CSD2410 CSE2410 CSD2425 CSE2425 CSD2450 CSE2450 CSD2475 CSE2475 CSD2490 CSE2490 24-280 24-280 24-280 24-280 24-280 0.15-10 0.15-25 0.15-50 0.25-75 0.25-90 Transient Overvoltage [Vpk] 600 600 600 600 600 Max. Surge Current, (16.6ms) [Apk] 120 250 625 1000 1200 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 1.6 Thermal Resistance Junction to Case (RθJC ) [˚C/W] OUTPUT SPECIFICATIONS ➀ Operating Voltage (47-63 Hz) [Vrms] ➂ [Arms] Load Current Range 1.48 1.02 0.63 0.31 0.28 Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] 60 260 1620 4150 6000 Max. Off-State Leakage Current @ Rated Voltage [mA] 1.0 1.0 1.0 1.0 1.0 ➁ 500 500 500 500 500 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 0.5 0.5 0.5 0.5 0.5 Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] Max. Turn-On Time ➃ Max. Turn-Off Time Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS➀ DC CONTROL DC CONTROL (CSD PREFIX) (CSE PREFIX) Control Voltage Range 3.5-15 Vdc 15-32 Vdc Max. Turn-On Voltage 3.5 Vdc 15.0 Vdc Min. Turn-Off Voltage 1.0 Vdc 1.0 Vdc 300 Ohm 2k Ohm 15 mA @ 5 Vdc 7mA @ 15 V Nominal Input Impedence Typical Input Current © 2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ All parameters at 25ºC unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 2. ➃ Turn-on time for random turn-on version (-10 suffix) is 0.1ms FastFax Document No.162 SERIES CS. Rev. 111103 PAGE 1 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Series CS 10-90Amp • 120/240 Vac - AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz , Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 10 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Terminals: Thermally Conductive Epoxy Screws and Saddle Clamps Furnished, Unmounted AVAILABLE OPTIONS F 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Faston Terminals (Up to 50A Models) Example: CSD2425F 1 OUTPUT 8-32 TERMINAL (2 PLACES ) 2 1.87 (47.5) G -- Input Status LED. Example: CSD2425G Note: Control Voltage Range 5-15Vdc for CSD Models. 4 Internal Overvoltage Protection. Relay Will Self Trigger Between 450-600 Vpk. Not Suitable For Capacitive Loads. Example: CSD2425P -10 Phase Controllable Example: CSD2425-10 1 Fastons: Single pair (up to 25A) Double pair* (up to 50A). * Caution: User must connect to both pairs Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. APPROVALS UL E116949 CSA LR81689 VDE 10143 UG FastFax Document No.162 SERIES CS. Rev. 111103 PAGE 2 OF 3 6-32 TERMINAL (2 PLACES) 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Screw Torque Requirements: 6-32 Screws - 10 in./lbs., 8-32 and 10-32 Screws - 20in./lbs. (Screws dry without grease.) 3 1.00 (25.4) 1.80 (45.7) BASE PLATE .125 (3.2) P + INPUT OUTPUT -4 2 + INPUT 1.00 (25.4) 1.80 (45.7) .78 (19.8) .90 (22.9) FASTON TERMINAL .250 X .032 (2 PLCS.) .87 REF. (22.2) 1.87 (47.5) BASE PLATE .125 (3.2) 2.30 (58.4) 1.70 (43.2) 2.30 (58.4) 1.70 (43.2) 3 FASTON TERMINAL .187 X .032 (2 PLCS.) .78 (19.8) .90 (22.9) All dimensions are in inches (millimeters) © 2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Series CS 10-90Amp • 120/240 Vac - AC OUTPUT CURRENT DERATING CURVES 10A 25A 12 30 4 120 100 3˚C/W 2˚C/W 20 15 110 10 NO HEATSINK 5 0 6 8 10 50A 40 60 80 5 80 20 40 60 80 60 80 90 1˚C/W 110 40 .2˚C/W .4˚C/W Power Dissipation 100 Base Plate Temp [˚C] .3˚C/W .5˚C/W 80 100 1ºC/W 110 40 120 120 0 Max Ambient Temp. [˚C] 40 90A 120 NO HEATSINK 0 50 20 Max Ambient Temp. [˚C] 120 95 Power Dissipation 110 20 40 25 .5˚C/W Base Plate Temp [˚C] 100 2˚C/W 30 20 90 40 20 15 75A .5˚C/W 1.5˚C/W Load Current [Arms] 10 Load Current [Arms] 120 1˚C/W Power Dissipation Power Dissipation 20 Max Ambient Temp. [˚C] 0 15 30 45 60 Load Current [Arms] 75 20 40 60 80 Max Ambient Temp. [˚C] 20 40 60 80 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] © 2003 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No.162 SERIES CS. Rev. 111103 PAGE 3 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Base Plate Temp [˚C] 4 Load Current [Arms] 10 120 0 2 60 Base Plate Temp [˚C] 115 NO HEATSINK 25 Power Dissipation 8 Base Plate Temp [˚C] 1˚C/W 110 5˚C/W Power Dissipation 95 3˚C/W 7˚C/W 9˚C/W Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series CMD/CMA24 25-125Amp • 240 Vac - AC OUTPUT • Zero Voltage and Random Turn-On Switching • Panel Mount • Status Indicating LED • DC or AC Control • Integrated Overvoltage Protection by Automatic Self Turn-On (Suffix P) MODEL NUMBERS Featuring state-of-the-art Surface Mount Technology, these SPST-NO relays deliver proven reliability in the most demanding applications. Output consists of an SCR AC switch and is available in zero-cross or random turn-on versions. Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. CMD2425 CMA2425 CMD2450 CMA2450 CMD2475 CMA2475 CMD2490 CMA2490 24-280 24-280 24-280 24-280 24-280 24-280 25 50 75 90 110 125 Min. Load Current, [Arms] 0.15 0.15 0.25 0.25 0.25 0.25 Transient Overvoltage [Vpk] 600 600 600 600 600 600 Max. Surge Current, (16.6ms) [Apk] 250 625 1000 1200 1500 1750 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 1.6 1.6 Thermal Resistance Junction to Case (R θJC) [˚C/W] 1.02 0.63 0.31 0.28 0.25 0.22 Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] 260 1620 4150 6000 9340 12700 10 10 10 10 10 10 500 500 500 500 500 500 OUTPUT SPECIFICATIONS ➀ Operating Voltage (47-63 Hz) [Vrms] Max. Load Current➂ [Arms] Max. Off-State Leakage Current @ Rated Voltage [mArms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] Max. Turn-On Time ➁ ➃ 1/2 Cycle (DC Control), 10.0 msec (AC Control) 1/2 Cycle (DC Control), 40.0 msec(AC Control) Max. Turn-Off Time 0.5 Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ DC CONTROL Control Voltage Range CMD24110 CMD24125 CMA24110 CMA24125 3-32 Vdc AC CONTROL 90-140 Vrms Max. Reverse Voltage 32 Vdc — Max. Turn-On Voltage 3.0 Vdc 90 Vrms Min. Turn-Off Voltage 1.0 Vdc 10 Vrms 30.0mA ➄ — 0.5 0.5 0.5 0.5 0.5 GENERAL SPECIFICATIONS 4000 Vrms Dielectric Strength 50/60Hz Input/Output/Base 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 8 pF Max. Capacitance Input/Output Max. Input Current Typical Input Current 17mA @ 5 Vdc 15mA @ 120 Vrms GENERAL NOTES ➀ All parameters at 25˚C unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ HEAT SINKING REQUIRED, for derating curves see page 2. ➃ Turn-on time for DC control random turn-on versions is 0.02msec. ➄ Input circuitry incorporates active current limiter. -40 to 80˚C Ambient Operating Temperature Range -40 to 125˚C Ambient Storage Temperature Range Green LED Status Indicating Display MECHANICAL SPECIFICATIONS Weight: (typical) Encapsulation: 3.0 oz. (86.5g) Thermally Conductive Epoxy Terminals: Cage Type Maximum Wire Size- Output: AWG 8 (3.8mm) Input: AWG12 (2.5mm) Recommended Terminal Screw Torque Range: Output: 10-15 in lb (1.1-1.7 Nm) Input: 5-6 in lb (0.6-0.7 Nm) © 2003 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No. 170 SERIES CMD/CMA. Rev. 111403 PAGE 1 OF 6 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series CMD/CMA24 25-125Amp • 240 Vac - AC OUTPUT 0.75 (19.1) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. .45 (11.4) MECHANICAL SPECIFICATIONS TU INP S All dimensions are in inches (millimeters) U T ST A INPUT 2.5 (63.5) 2.4 (63.5) 3.0 (76.2) CMRD24/CMRA24 available with factory mounted heat sink and DIN rail mounting clip. Specifications available via FastFax, request document No. 171. OUTPUT AVAILABLE OPTIONS -10 Random Turn-On, Phase Controllable Example: CMD2450-10 1.75 (44.5) E 24 Vac Input (18-36 Vac) Example: CMA2450E .9 (22.9) P Internal Overvoltage Protection Relay Will Self Trigger Between 450-600 Vpk. Not Suitable For Capacitive Loads Example: CMD2450P 3.0 (76.2) 1.15 (29.2) CURRENT DERATING CURVES 25A 50A 75A 60 90 15 110 NO HEATSINK 5 40 110 20 120 15 20 25 20 40 60 80 20 90A 40 50 20 40 60 80 110 40 20 40 60 80 Max Ambient Temp. [˚C] 60 75 20 40 60 80 Max Ambient Temp. [˚C] 90 .2˚C/W 120 .5˚C/W 100 80 1˚C/W 110 40 90 .4ºC/W 120 .5˚C/W .2˚C/W 100 80 1˚C/W 110 40 120 0 0 45 125A 120 0 Load Current [Arms] 30 Load Current [Arms] 160 .4˚C/W Power Dissipation 100 1˚C/W 80 15 160 Base Plate Temp [˚C] 80 60 110 30 Max Ambient Temp. [˚C] .2˚C/W .4˚C/W 40 1˚C/W 110A 90 .5˚C/W Power Dissipation 30 Load Current [Arms] 120 20 60 0 10 Max Ambient Temp. [˚C] 100 120 0 Power Dissipation 10 Load Current [Arms] 95 .3˚C/W .5˚C/W 120 NO HEATSINK 0 5 100 2˚C/W Base Plate Temp [˚C] 10 90 Base Plate Temp [˚C] 20 .5˚C/W 1.5˚C/W Power Dissipation 100 2˚C/W Base Plate Temp [˚C] Power Dissipation 3˚C/W Power Dissipation 1˚C/W 1˚C/W 25 Base Plate Temp [˚C] 95 Base Plate Temp [˚C] 30 120 0 30 60 90 120 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] 30 60 90 120 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] © 2003 CRYDOM CORP, Specifications subject to change without notice. APPROVALS UL E116949, E116950 CSA LR81689 VDE 126921 UG (up to 90A models only) FastFax Document No. 170 SERIES CMD/CMA. Rev. 111403 PAGE 2 OF 6 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series CMD/CMA48 25-125Amp • 480 Vac - AC OUTPUT • Zero Voltage and Random Turn-On Switching • Panel Mount • Status Indicating LED • DC or AC Control • Integrated Overvoltage Protection by Automatic Self Turn-On (Suffix P) MODEL NUMBERS Featuring state-of-the-art Surface Mount Technology, these SPST-NO relays deliver proven reliability in the most demanding applications. Output consists of an SCR AC switch and is available in zero-cross or random turn-on versions. Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. CMD4825 CMA4825 CMD4850 CMA4850 CMD4875 CMA4875 CMD4890 CMA4890 48-530 48-530 48-530 48-530 48-530 48-530 25 50 75 90 110 125 Min. Load Current, [Arms] 0.15 0.15 0.25 0.25 0.25 0.25 Transient Overvoltage [Vpk] 1200 1200 1200 1200 1200 1200 Max. Surge Current, (16.6ms) [Apk] 250 625 1000 1200 1500 1750 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.7 1.7 1.7 1.7 1.7 1.7 Thermal Resistance Junction to Case (R θJC) [˚ C/W] 1.02 0.63 0.31 0.28 0.25 0.22 Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] 260 1620 4150 6000 9340 12700 10 10 10 10 10 10 500 500 500 500 500 500 OUTPUT SPECIFICATIONS ➀ Operating Voltage (47-63 Hz) [Vrms] Max. Load Current ➂ [Arms] Max. Off-State Leakage Current @ Rated Voltage [mArms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] Max. Turn-On Time ➁ ➃ 1/2 Cycle (DC Control), 10.0 msec (AC Control) 1/2 Cycle (DC Control), 40.0 msec(AC Control) Max. Turn-Off Time 0.5 Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ DC CONTROL AC CONTROL Control Voltage Range 4-32 Vdc 90-140 Vrms Max. Reverse Voltage 32 Vdc — Max. Turn-On Voltage 4.0 Vdc 90 Vrms Min. Turn-Off Voltage 1.0 Vdc 10 Vrms 30.0mA ➄ — Max. Input Current Typical Input Current CMD48110 CMD48125 CMA48110 CMA48125 14mA @ 5 Vdc 15mA @ 120 Vrms GENERAL NOTES ➀ All parameters at 25˚ C unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ HEAT SINKING REQUIRED, for derating curves see page 2. ➃ Turn-on time for DC control random turn-on versions is 0.02msec. ➄ Input circuitry incorporates active current limiter. 0.5 0.5 0.5 0.5 0.5 GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 8 pF Max. Capacitance Input/Output -40 to 80˚C Ambient Operating Temperature Range -40 to 125˚C Ambient Storage Temperature Range Green LED Status Indicating Display MECHANICAL SPECIFICATIONS 3.0 oz. (86.5g) Weight: (typical) Encapsulation: Thermally Conductive Epoxy Terminals: Cage Type Maximum Wire Size- Output: AWG 8 (3.8mm) Input: AWG12 (2.5mm) Recommended Terminal Screw Torque Range: Output: 10-15 in lb (1.1-1.7 Nm) Input: 5-6 in lb (0.6-0.7 Nm) © 2003 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No. 170 SERIES CMD/CMA. Rev. 111403 PAGE 3 OF 6 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series CMD/CMA48 25-125Amp • 480 Vac - AC OUTPUT 0.75 (19.1) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. .45 (11.4) MECHANICAL SPECIFICATIONS TU INP S All dimensions are in inches (millimeters) U T ST A INPUT 2.5 (63.5) 2.4 (63.5) 3.0 (76.2) CMRD48/CMRA48 available with factory mounted heat sink and DIN rail mounting clip. Specifications available via FastFax, request document No. 171. OUTPUT AVAILABLE OPTIONS -10 Random Turn-On, Phase Controllable Example: CMD4850-10 1.75 (44.5) E 24 Vac Input (18-36 Vac) Example: CMA4850E .9 (22.9) P Internal Overvoltage Protection. Relay Will Self Trigger Between 900-1200Vpk. Not suitable For Capacitive Loads. Example: CMD4850P 3.0 (76.2) 1.15 (29.2) CURRENT DERATING CURVES 25A 50A 75A 60 90 20 15 110 10 NO HEATSINK 5 40 110 20 20 25 20 40 60 80 10 Max Ambient Temp. [˚C] 20 90A 40 50 20 40 60 80 110 40 20 40 60 80 Max Ambient Temp. [˚C] APPROVALS UL E116949, E116950 CSA LR81689 VDE 126921 UG (up to 90A models only) FastFax Document No. 170 SERIES CMD/CMA. Rev. 111403 PAGE 4 OF 6 60 75 20 40 60 80 Max Ambient Temp. [˚C] 90 .2˚C/W 120 .5˚C/W 100 80 1˚C/W 110 40 90 .4˚C/W 120 .5˚C/W .2˚C/W 100 80 1˚C/W 110 40 120 0 0 45 125A 120 0 80 30 Load Current [Arms] 160 .4˚C/W Power Dissipation 100 1˚C/W 60 15 160 Base Plate Temp [˚C] 80 40 110 30 Max Ambient Temp. [˚C] .2˚C/W .4˚C/W Load Current [Arms] 1˚C/W 110A 90 .5˚C/W Power Dissipation 30 Load Current [Arms] 120 20 60 0 Power Dissipation 15 100 120 0 Base Plate Temp [˚C] 10 95 .3˚C/W .5˚C/W 120 NO HEATSINK 0 Load Current [Arms] 100 2˚C/W 120 5 90 Base Plate Temp [˚C] 2˚C/W .5˚C/W 1.5˚C/W Power Dissipation 3˚C/W Base Plate Temp [˚C] Power Dissipation 100 Power Dissipation 1˚C/W 1˚C/W 25 Base Plate Temp [˚C] 95 Base Plate Temp [˚C] 30 120 0 30 60 90 120 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] 30 60 90 120 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] © 2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series CMD/CMA60 25-125Amp • 600Vac - AC OUTPUT • DC or AC Control Featuring state-of-the-art Surface Mount Technology, these SPST-NO relays deliver proven reliability in the most demanding applications. Output consists of an SCR AC switch and is available in zero-cross or random turn-on versions. • Integrated Overvoltage Protection by Automatic Self Turn-On (Suffix P) Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. • Zero Voltage and Random Turn-On Switching • Panel Mount • Status Indicating LED MODEL NUMBERS CMD6025 CMA6025 OUTPUT SPECIFICATIONS ➀ CMD6050 CMA6050 CMD6075 CMA6075 CMD6090 CMA6090 CMD60110 CMD60125 CMA60110 CMA60125 600 600 600 600 600 600 48-660 48-660 48-660 48-660 48-660 48-660 25 50 75 90 110 125 Min. Load Current, [Arms] 0.15 0.15 0.25 0.25 0.25 0.25 Transient Overvoltage [Vpk] 1200 1200 1200 1200 1200 1200 Max. Surge Current, (16.6ms) [Apk] 250 625 1000 1200 1500 1750 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.7 1.7 1.7 1.7 1.7 1.7 Thermal Resistance Junction to Case (R θJC) [˚C/W] 1.02 0.63 0.31 0.28 0.25 0.22 Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] 260 1620 4150 6000 9340 12700 Max. Off-State Leakage Current @ Rated Voltage [mArms] 1.0 1.0 1.0 1.0 1.0 1.0 500 500 500 500 500 500 Nominal LIne Voltage ( ±10%) [Vrms] Operating Voltage (47-63 Hz) [Vrms] Max. Load Current ➂ [Arms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] Max. Turn-On Time ➁ ➃ 1/2 Cycle (DC Control), 10.0 msec (AC Control) 1/2 Cycle (DC Control), 40.0 msec(AC Control) Max. Turn-Off Time 0.5 Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ DC CONTROL AC CONTROL Control Voltage Range 4-32 Vdc 90-140 Vrms Max. Reverse Voltage 32 Vdc — Max. Turn-On Voltage 4.0 Vdc 90 Vrms Min. Turn-Off Voltage 1.0 Vdc 10 Vrms 30.0mA ➄ — Max. Input Current Typical Input Current GENERAL NOTES 14mA @ 5 Vdc 15mA @ 120 Vrms 0.5 0.5 0.5 0.5 GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 8 pF Max. Capacitance Input/Output -40 to 80˚C Ambient Operating Temperature Range -40 to 125˚C Ambient Storage Temperature Range Green LED Status Indicating Display MECHANICAL SPECIFICATIONS 3.0 oz. (86.5g) Weight: (typical) ➀ All parameters at 25˚C unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ HEAT SINKING REQUIRED, for derating curves see page 2. ➃ Turn-on time for DC control random turn-on versions is 0.02msec. ➄ Input circuitry incorporates active current limiter. 0.5 Encapsulation: Thermally Conductive Epoxy Terminals: Cage Type Maximum Wire Size- Output: AWG 8 (3.8mm) Input: Awg12 (2.5mm) Recommended Terminal Screw Torque Range: Output: 10-15 in lb (1.1-1.7 Nm) Input: 5-6 in lb (0.6-0.7 Nm) © 2003 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No. 170 SERIES CMD/CMA. Rev. 111403 PAGE 5 OF 6 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series CMD/CMA60 25-125Amp • 600Vac - AC OUTPUT 0.75 (19.1) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. .45 (11.4) MECHANICAL DIMENSIONS U TU INP S All dimensions are in inches (millimeters) T ST A INPUT 2.5 (63.5) 2.4 (63.5) 3.0 (76.2) CMRD60/CMRA60 available with factory mounted heat sink and DIN rail mounting clip. Specifications available via FastFax, request document No. 171. OUTPUT AVAILABLE OPTIONS -10 Random Turn-On, Phase Controllable Example: CMD6050-10 E 24 Vac Input (18-36 Vac) Example: CMA6050E P Internal Overvoltage Protection. Relay Will Self Trigger Between 900-1200Vpk. Not Suitable For Capacitive Loads. Example: CMD6050P 1.75 (44.5) 3.0 (76.2) .9 (22.9) 1.15 (29.2) CURRENT DERATING CURVES 25A 50A 75A 60 90 110 10 NO HEATSINK 5 40 110 20 120 20 25 20 40 60 80 10 Max Ambient Temp. [˚C] 20 90A 40 50 20 40 60 80 110 40 0 20 40 60 80 Max Ambient Temp. [˚C] 75 20 40 60 80 Max Ambient Temp. [˚C] 90 .2˚C/W 120 .5˚C/W 100 80 1˚C/W 110 40 90 .4˚C/W 120 .5˚C/W .2˚C/W 100 80 1˚C/W 110 40 120 0 80 60 125A 120 0 45 160 .4˚C/W Power Dissipation 100 1˚C/W 60 30 Load Current [Arms] 160 Base Plate Temp [˚C] 80 40 15 Max Ambient Temp. [˚C] .2˚C/W .4˚C/W Load Current [Arms] 110 30 110A 90 .5˚C/W Power Dissipation 30 Load Current [Arms] 120 20 1˚C/W 0 Power Dissipation 15 60 120 0 Base Plate Temp [˚C] 10 Load Current [Arms] 100 120 NO HEATSINK 0 5 100 2˚C/W .3˚C/W .5˚C/W Base Plate Temp [˚C] 15 95 Power Dissipation 20 90 1.5˚C/W Power Dissipation 2˚C/W Base Plate Temp [˚C] Power Dissipation 100 3˚C/W .5˚C/W 1˚C/W 1˚C/W 25 Base Plate Temp [˚C] 95 Base Plate Temp [˚C] 30 120 0 30 60 90 120 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] 30 60 90 120 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] © 2003 CRYDOM CORP, Specifications subject to change without notice. APPROVALS UL E116949, E116950 CSA LR81689 VDE 126921 UG (up to 90A models only) FastFax Document No. 170 SERIES CMD/CMA. Rev. 111403 PAGE 6 OF 6 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series CSW 10-90Amp • 120/240 Vac • AC OUTPUT • Low Leakage The Series CS has an SCR AC switch output featuring low off-state leakage (1mA, snubberless), zero-voltage switching and a broadened operating range (24-280Vac). This wide range permits optimum performance at both 120Vac and 240Vac line voltages. • SCR Output • Panel Mount • Zero Voltage Switching • Wide Control Range Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. MODEL NUMBERS CSW2410 CSW2425 CSW2450 CSW2475 CSW2490 24-280 24-280 24-280 24-280 24-280 0.15-10 0.15-25 0.15-50 0.25-75 0.25-90 Transient Overvoltage [Vpk] 600 600 600 600 600 Max. Surge Current, (16.6ms) [Apk] 120 250 625 1000 1200 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 1.6 Thermal Resistance Junction to Case (RθJC ) [˚C/W] OUTPUT SPECIFICATIONS ➀ Operating Voltage (47-63 Hz) [Vrms] Load Current Range ➂ [Arms] 1.48 1.02 0.63 0.31 0.28 Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] 60 260 1620 4150 6000 Max. Off-State Leakage Current @ Rated Voltage [mA] 1.0 1.0 1.0 1.0 1.0 ➁ 500 500 500 500 500 Max. Turn-On Time 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle Max. Turn-Off Time 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 0.5 0.5 0.5 0.5 0.5 Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ DC CONTROL Control Voltage Range 3-32 Vdc Max. Turn-On Voltage 3 Vdc Min. Turn-Off Voltage 1.0 Vdc See note 4 Nominal Input Impedence 10mA @ 12 Vdc Typical Input Current © 2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➁ All parameters at 25ºC unless otherwise specified. ➂ Heat sinking required, for derating curves see page 2. ➃ Input Circuit Incorporates Active Current Limiter. SERIES CSW. Rev. 111803 PAGE 1 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series CSW 10-90Amp • 120/240 Vac • AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz , Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 10 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS Weight: (typical) Encapsulation: Thermally Conductive Epoxy Terminals: Screws and Saddle Clamps Furnished, Unmounted AVAILABLE OPTIONS F Faston Terminals (Up to 50A Models) Example: CSW2425F G Input Status LED. Example: CSW2425G P Phase Controllable Example: CSW2425-10 H Heat Transfer Pad (Attached) Example: CSW2425H 1 -- 2 + INPUT 6-32 TERMINAL (2 PLACES) 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1 OUTPUT -4 2 + INPUT 1.00 (25.4) 1.80 (45.7) .78 (19.8) .90 (22.9) FASTON TERMINAL .250 X .032 (2 PLCS.) .87 REF. (22.2) 1.87 (47.5) BASE PLATE .125 (3.2) 2.30 (58.4) 1.70 (43.2) 3 1.00 (25.4) 1.80 (45.7) BASE PLATE .125 (3.2) Fastons: Single pair (up to 25A) Double pair* (up to 50A). * Caution: User must connect to both pairs EN61000-4-2, Level 3 ESD EN61000-4-4, Level 3 Burst Output: EN61000-4-2, Level 3 ESD Level 4 ESD (with P option) EN61000-4-4, Level 3 Burst Level 4 Burst (with P option) EN61000-4-5, Level 4 Surge SERIES CSW. Rev. 111803 PAGE 2 OF 3 4 Screw Torque Requirements: 6-32 Screws - 10 in./lbs., 8-32 and 10-32 Screws - 20in./lbs. (Screws dry without grease.) EMC Compatibility APPROVALS UL Pending CSA Pending VDE Pending OUTPUT 8-32 TERMINAL (2 PLACES ) 1.87 (47.5) Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. Input: 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Internal Overvoltage Protection. Relay Will Self Trigger Between 450-600 Vpk. Not Suitable For Capacitive Loads. Example: CSW2425P -10 3.0 oz. (86.5g) 2.30 (58.4) 1.70 (43.2) 3 FASTON TERMINAL .187 X .032 (2 PLCS.) .78 (19.8) .90 (22.9) All dimensions are in inches (millimeters) © 2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series CSW 10-90Amp • 120/240 Vac • AC OUTPUT CURRENT DERATING CURVES 10A 25A 12 30 4 120 100 3˚C/W 2˚C/W 20 15 110 10 NO HEATSINK 5 0 6 8 10 50A 40 60 80 5 .5˚C/W 80 20 40 60 80 60 80 90 1˚C/W 110 40 .2˚C/W .4˚C/W Power Dissipation 100 Base Plate Temp [˚C] .3˚C/W .5˚C/W 80 100 1ºC/W 110 40 120 120 0 Max Ambient Temp. [˚C] 40 90A 120 NO HEATSINK 0 50 20 Max Ambient Temp. [˚C] 120 95 Power Dissipation 110 20 40 25 .5˚C/W Base Plate Temp [˚C] 100 2˚C/W 30 20 90 40 20 15 75A 1.5˚C/W Load Current [Arms] 10 Load Current [Arms] 120 1˚C/W Power Dissipation 20 Max Ambient Temp. [˚C] 0 15 30 45 60 Load Current [Arms] 75 20 40 60 80 Max Ambient Temp. [˚C] 20 40 60 80 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] © 2003 CRYDOM CORP, Specifications subject to change without notice. SERIES CSW. Rev. 111803 PAGE 3 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Base Plate Temp [˚C] 4 Load Current [Arms] 10 120 0 2 60 Base Plate Temp [˚C] 115 NO HEATSINK 25 Power Dissipation 8 Base Plate Temp [˚C] 1˚C/W 110 5˚C/W Power Dissipation 95 3˚C/W 7˚C/W 9˚C/W Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CW 24 10-125Amp - 120/240 Vac - AC OUTPUT • • • • • • • • • 600V Blocking Low Leakage SCR Output Zero and Random Voltage Switching LED Status Indicator Panel Mount Intergrated Removable Fingerproof Cover User Friendly, Universal Connectors EMC Compliant Design Crydom's CW24 line of solid state relays offer an SCR AC switch output featuring low offstate leakage (1mA, snubberless), zero and random voltage switching and a broadened operating range (24-280Vac). This wide range permits optimum perfomance at both 120Vac and 240Vac line voltages. Manufactured in Crydom's ISO 9001 Certified facility for optimum product performance and reliability. CWD2410 CWA2410 CWD2425 CWA2425 CWD2450 CWA2450 CWD2490 CWA2490 CWD24125 CWA24125 24-280 24-280 24-280 24-280 24-280 0.15-10 0.15-25 0.15-50 0.25-90 0.25-125 Transient Overvoltage [Vpk] 600 600 600 600 600 Max. Surge Current, (16.6ms) [Apk] 400 600 850 1350 2000 Max. Surge Current (20ms) [Apk] 380 570 810 1290 1900 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.3 1.3 1.3 1.3 1.25 Thermal Resistance Junction to Case (RθJC ) [˚C/W] 0.35 0.35 0.2 0.14 0.13 Maximum I 2 t for Fusing, (8.3 ms) [A 2s] 660 1500 3000 7560 16600 Maximum I 2 t for Fusing, (10ms) [A 2 s] 720 1620 3280 8320 18000 Max. Off-State Leakage Current @ Rated Voltage [mA] ➅ 1.0 1.0 1.0 1.0 1.0 500 500 500 500 500 Max. Turn-On Time ➃ ➄ 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle Max. Turn-Off Time ➄ 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 0.5 0.5 0.5 0.5 0.5 MODEL NUMBERS OUTPUT SPECIFICATIONS ➀ Operating Voltage (47-63 Hz) [Vrms] Load Current Range ➂ [Arms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µs] Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ ➁ DC Control AC Control 24 Vac nominal E - suffix Control Voltage Range 3-32 Vdc 18-36 Vrms 90-280 Vrms Max. Turn-On Voltage 3 Vdc 18 Vrms 90 Vrms Min. Turn-Off Voltage 1.0 Vdc 2 Vrms 10 Vrms See note 7 1 k ohm Nominal Input Impedence Typical Input Current 10 mA @ 12 Vdc GENERAL NOTES ➀ All parameters at 25˚C unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 2. ➃ Turn-on time for random turn-on version is 0.02 msec. ➄ Turn-on and turn-off time for AC input models is 50ms. ➅ 10mA for models with snubber. ➆ Input circuit incorporates active current limiter. SERIES CW24 Rev. 081403 PAGE 1 OF 3 24mA@24Vrms AC Control 120/240Vac nominal Std. (no suffix) 21.5 k ohms 6 mA @ 120 Vrms © 2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 8 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation Thermally Conductive Epoxy Terminals Screw Type, Finger Proof Output: 8-32, Combo Drive Input: 6-32, Combo Drive Max. Torque Output: 20 in lb (2.2Nm) Input: 10 in lb (1.1Nm) Output: 2 x AWG 8 (3.8mm) Input: 2 x AWG 12 (2.5mm) Max. Wire Size Available Options -10 MECHANICAL OUTLINE Random Turn-On. Example: CWD2425-10 MOUNTING HOLE/SLOT 0.17 (4.3) DIA. E 24 Vac Input (18-36 Vac) Example: CWA2425E P Internal Overvoltage Protection. Relay Will Self Trigger Between 450-600 Vpk. Not Suitable For Capacitive Loads. Example: CWD2425P Internal Snubber Example: CWD2425S S H Heat Transfer Pad (Attached) Example: CWD2425H 2.30 (58.4) 2/T1 1.87 (47.5) 1.70 (43.2) +3/A1 4/A2 INPUT 1.00 (25.4) 1.30 (33.0) All dimensions are in inches (millimeters) EN61000-4-2, Level 3 ESD EN61000-4-4, Level 3 Burst EN61000-4-2, Level 3 ESD Level 4 ESD (with P option) EN61000-4-4, Level 3 Burst Level 4 Burst (with P option) EN61000-4-5, Level 4 Surge APPROVALS UL E116949 CSA 1405925 VDE 40007242 SERIES CW24 Rev. 081403 PAGE 2 OF 3 OUTPUT 1.80 (45.7) EMC Compatibility Output: OUTPUT 1/L1 BASE PLATE .125 (3.2) Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom's Heat Sink specification sheet for all the details. Input: 1.10 (27.9) .45 (11.4) © 2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CW 24 10-125Amp - 120/240 Vac - AC OUTPUT CURRENT DERATING CURVES 20 3˚C/W 15 120 10 5 2 0 2 4 6 8 10 Load Current [Arms] 20 40 60 120 80 50 .1˚C/W 2˚C/W 123 40 1.5˚C/W 115 117 30 119 20 121 10 123 0 0 5 Max Ambient Temp. [˚C] 10 15 20 25 Load Current [Arms] 20 40 60 10 80 20 30 40 Load Current [Arms] Max Ambient Temp. [˚C] 50 20 40 60 80 Max Ambient Temp. [˚C] 125A 90A 130 120 80 .5˚C/W 115 1˚C/W 60 118 40 121 20 .4˚C/W 100 Power Dissipation 112 Base Plate Temp [˚C] .4˚C/W 100 Power Dissipation 116 109 112 .5˚C/W 115 80 1˚C/W 60 117 40 120 20 122 124 0 0 20 40 60 80 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] 30 60 90 120 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] © 2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 SERIES CW24 Rev. 081403 PAGE 3 OF 3 Base Plate Temp [˚C] 123 4 2˚C/W 4˚C/W Base Plate Temp [˚C] 6 25 Power Dissipation 8 7˚C/W Power Dissipation 121 9˚C/W Base Plate Temp [˚C] 10 Power Dissipation 50A 25A Base Plate Temp [˚C] 10A Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CW 48 10-125Amp - 600Vac - AC OUTPUT • • • • 1200V Blocking Low Leakage SCR Output Zero and Random Voltage Switching LED Status Indicator Panel Mount Intergrated Removable Fingerproof Cover User Friendly, Universal Connectors EMC Compliant Design • • • • • The Series CW48 has an SCR AC switch output featuring low off-state leakage (1mA, snubberless), zero and random voltage switching and a broadened operating range (48-660Vac). This wide range permits optimum perfomance at voltages from 240 Vac to 600 Vac line voltages. Manufactured in Crydom's ISO 9001 Certified facility for optimum product performance and reliability. CWD4810 CWA4810 CWD4825 CWA4825 CWD4850 CWA4850 CWD4890 CWA4890 48-660 48-660 48-660 48-660 48-660 0.15-10 0.15-25 0.15-50 0.25-90 0.25-125 1200 1200 1200 1200 1200 Max. Surge Current (16.6ms) [Apk] 400 600 850 1350 2000 MODEL NUMBERS OUTPUT SPECIFICATIONS ➀ Operating Voltage (47-63 Hz) [Vrms] ➇ Load Current Range ➂ [Arms] Transient Overvoltage [Vpk] CWD48125 CWA48125 Max. Surge Current (20ms) [Apk] 380 570 810 1290 1900 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.3 1.3 1.3 1.3 1.25 Thermal Resistance Junction to Case (RθJC ) [˚C/W] 0.35 0.35 0.2 0.14 0.13 Maximum I 2 t for Fusing, (8.3 ms) [A 2s] 660 1500 3000 7560 16600 Maximum I 2 t for Fusing, (10 ms) [A 2s] 720 1620 3280 8320 18000 Max. Off-State Leakage Current @ Rated Voltage [mA] ➅ 1.0 1.0 1.0 1.0 1.0 500 500 500 500 500 Max. Turn-On Time ➃ ➄ 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle Max. Turn-Off Time ➄ 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 1/2 Cycle 0.5 0.5 0.5 0.5 0.5 Min. Off-State dv/dt @ Max. Rated Voltage [V/µs] Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ ➁ DC Control AC Control 24 Vac nominal E - suffix Control Voltage Range 4-32 Vdc 18-36 Vrms 90-280 Vrms Max. Turn-On Voltage 4 Vdc 18 Vrms 90 Vrms Min. Turn-Off Voltage 1.0 Vdc 2 Vrms 10 Vrms See note 7 1 k ohm Nominal Input Impedence Typical Input Current 10 mA @ 12 Vdc GENERAL NOTES ➀ All parameters at 25˚C unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 2. ➃ Turn-on time for random turn-on version is 0.02 msec. ➄ Turn-on and turn-off time for AC input models is 50ms. ➅ 10mA for models with snubber. ➆ Input circuit incorporates active current limiter. ➇ 48-530 Vrms for models with snubber. SERIES CW48 Rev. 081803 PAGE 1 OF 3 24mA@24Vrms AC Control 120/240Vac nominal Std. (no suffix) 21.5 k ohms 6 mA @ 120 Vrms © 2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CW 48 10-125Amp - 600Vac - AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 8 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation Thermally Conductive Epoxy Terminals Screw Type, Finger Proof Output: 8-32, Combo Drive Input: 6-32, Combo Drive Max. Torque Output: 20 in lb (2.2Nm) Input: 10 in lb (1.1Nm) Output: 2 x AWG 8 (3.8mm) Input: 2 x AWG 12 (2.5mm) Max. Wire Size Available Options MECHANICAL OUTLINE -10 Random Turn-On. Example: CWD4825-10 E 24 Vac Input (18-36 Vac) Example: CWA4825E P Internal Overvoltage Protection. Relay Will Self Trigger Between 900-1200 Vpk. Not Suitable For Capacitive Loads. Example: CWD4825P Internal Snubber Example: CWD4825S S MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1.10 (27.9) .45 (11.4) OUTPUT 1/L1 2.30 (58.4) 2/T1 1.87 (47.5) 1.70 (43.2) +3/A1 4/A2 INPUT H Heat Trasfer Pad (Attached) Example: CWD4825H BASE PLATE .125 (3.2) Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom's Heat Sink specification sheet for all the details. 1.00 (25.4) 1.30 (33.0) 1.80 (45.7) EMC Compatibility Input: Output: EN61000-4-2, Level 3 ESD EN61000-4-4, Level 3 Burst EN61000-4-2, Level 3 ESD Level 4 ESD (with P option) EN61000-4-4, Level 3 Burst Level 4 Burst (with P option) EN61000-4-5, Level 4 Surge APPROVALS UL E116949 CSA 1405925 VDE 40007242 SERIES CW48 Rev. 081803 PAGE 2 OF 3 All dimensions are in inches (millimeters) © 2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CW 48 10-125Amp - 600Vac - AC OUTPUT CURRENT DERATING CURVES 4 20 3˚C/W 15 120 10 5 2 0 2 4 6 8 10 Load Current [Arms] 20 40 60 120 80 5 10 15 20 Load Current [Arms] 25 20 121 10 123 40 60 10 80 20 30 40 50 Load Current [Arms] 115 1˚C/W 60 118 40 121 20 124 0 20 40 60 80 Max Ambient Temp. [˚C] .4˚C/W 100 Power Dissipation .5˚C/W Base Plate Temp [˚C] Power Dissipation 112 80 0 20 20 40 60 80 Max Ambient Temp. [˚C] 125A .4˚C/W 80 119 130 120 100 60 1.5˚C/W 115 117 30 Max Ambient Temp. [˚C] 90A 40 40 0 0 Load Current [Arms] .1˚C/W 2˚C/W 123 Max Ambient Temp. [˚C] 20 50 109 112 .5˚C/W 115 80 1˚C/W 60 117 40 120 20 122 0 30 60 90 120 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] © 2003 CRYDOM CORP, Specifications subject to change without notice. SERIES CW48 Rev. 081803 PAGE 3 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Base Plate Temp [˚C] 123 116 2˚C/W 4˚C/W Base Plate Temp [˚C] 6 25 Power Dissipation 8 7˚C/W Power Dissipation 121 9˚C/W Base Plate Temp [˚C] 10 Power Dissipation 50A 25A Base Plate Temp [˚C] 10A Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series EZ 5-18Amp • 120/240, 480 Vac • AC OUTPUT • • • • Low Leakage Quick Connect Terminals SCR Output 24V Control Available (EZE Models) The Series EZ SPST-NO AC output relays offer a low profile package with the convenience of quick con- AC CONTROL (120Vac) (24Vac) MODEL NUMBERS DC CONTROL (5Vdc) (24Vdc) nect terminals. The Series EZ is the preferred choice for replacement of 120V and 240V Electro-mechanical relays. Output consists of an SCR switch and is available in Zero-Cross and Random Turn-On (Phase Controlable) versions. Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. EZ240A12 EZE240A12 EZ240A18 EZE240A18 EZ480A12 EZE480A12 EZ480A18 EZE480A18 EZ240D5 EZ240D12 EZE240D12 EZ240D18 EZE240D18 EZ480D12 EZE480D12 EZ480D18 EZE480D18 24-280 24-280 24-280 48-660 48-660 OUTPUT SPECIFICATIONS ➀ Operating Voltage (47-63 Hz) [Vrms] 5 12 18 12 18 Min. Load Current, [mArms] 150 150 150 150 150 Transient Overvoltage [Vpk] 600 600 600 1200 1200 Max. Surge Current, (16.6ms) [Apk] 40 150 200 150 200 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.5 1.5 1.5 1.5 1.5 Thermal Resistance Junction to Case (R θJC) [˚C/W] 2.0 2.0 1.1 2.0 1.1 Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] 95 95 170 95 170 Max. Off-State Leakage Current @ Rated Voltage [mArms] ➄ 0.1 0.1 0.1 0.1 0.1 Min. Off-State dv/dt @ Max. Rated Voltage [V/ µsec] ➁ 500 500 500 500 500 0.5 0.5 Max. Load Current ➃ [Arms] Max. Turn-On Time ➅ 1/2 Cycle (DC Input), 10.0 msec (AC Input) 1/2 Cycle (DC Input), 40.0 msec (AC Input) Max. Turn-Off Time 0.5 Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ Nominal Voltage 0.5 0.5 DC CONTROL 5Vdc 5Vdc 5Vdc AC CONTROL EZ240D5 EZ240D12 EZ240D18 EZ480D12 EZ480D18 24Vdc EZE240D12 EZE240D18 EZE480D12 EZE480D18 Control Voltage Range 4-15 Vdc 3-15 Vdc 4-15 Vdc 15-32 Vdc 90-140 Vrms 18-36 Vrms Max. Turn-On Voltage 4.0 Vdc 3.0 Vdc 4.0 Vdc 15.0 Vdc 90.0 Vrms 18.0 Vrms Min. Turn-Off Voltage 1.0 Vdc 1.0 Vdc 1.0 Vdc 1.0 Vdc 10.0 Vrms 2.0 Vrms 300 Ohms 300 Ohms 240 Ohms 1500 Ohms 10.6k Ohms 1.8k Ohms 13 mAdc 15 mAdc 15 mAdc 15 mAdc 10 mArms 10 mArms MODEL NUMBERS Nominal Input Impedance Typical Input Current @ Nominal Voltage GENERAL NOTES 120Vac EZ240A12 EZ240A18 EZ480A12 EZ480A18 24Vac EZE240A12 EZE240A18 EZE480A12 EZE480A18 © 2003 CRYDOM CORP, Specifications subject to change without notice. All parameters at 25˚ C unless otherwise specified. Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 240V, DC control models only, all others 2500Vrms. Heat sinking required, for derating curves see page 2. For recommended applications and more information contact: Off-State leakage for snubbered USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 version (suffix S) is 10.0 mArms. Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 ➅ Turn-on time for random turn-on versions Email: sales@crydom.com WEB SITE: http://www.crydom.com is 0.1 msec (DC Control Models). UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham FastFax Document No.160 Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. SERIES EZ. GERMANY: +49 (0)180 3000 506 Rev. 111203 PAGE 1 OF 2 ➀ ➁ ➂ ➃ ➄ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series EZ 5-18Amp • 120/240, 480 Vac • AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength ➂ 50/60Hz Input/Output/Base 4000 Vrms* 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 8 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS Weight: (typical) 1.5 oz. (43g) Encapsulation: Thermally Conductive Epoxy Terminals: .25 Inch Faston AVAILABLE OPTIONS *240V, DC Control Models Only. 2.63 (66.8) S Internal Snubber Example: EZ240D12S R Random Turn-On Switching Example: EZ240D12R, EZ240D12RS EZ240D5R 2.24 (56.9) 1 .197 DIA. (2 PLCS) 2 OUTPUT 1.00 (25.4) .49 (12.4) 3+ Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. PIN PIN PIN PIN 4 INPUT FASTON TERMINAL .250 X .032 4 PLCS. 1.50 (38.1) 1: 2: 3: 4: AC LOAD AC LOAD +DC CONTROL --- DC CONTROL .40 (10.2) 1.73 (43.9) .12 (3.0) .95 (24.1) All dimensions are in inches (millimeters) CURRENT DERATING CURVES 12A 5A 18 2 120 6˚C/W 116 NO HEATSINK 5 120 2˚C/W 12 5˚C/W 116 NO HEATSINK 6 112 120 1 124 0 1 2 3 4 5 Load Current [Arms] 10 20 40 60 80 Max Ambient Temp. [˚C] APPROVALS 2 4 6 8 10 Load Current [Arms] 12 20 40 60 80 Max Ambient Temp. [˚C] 124 0 3 6 9 12 15 18 Load Current [Arms] 40 60 80 Max Ambient Temp. [˚C] © 2003 CRYDOM CORP, Specifications subject to change without notice. UL E116950 CSA LR81689 VDE 10139 UG (240V DC Control Only) FastFax Document No.160 SERIES EZ Rev. 111203 PAGE 2 OF 2 20 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Base Plate Temp [˚C] 115 112 4˚C/W 10 Power Dissipation [W] NO HEATSINK 3 Power Dissipation [W] 4 Base Plate Temp [˚C] 110 5˚C/W Base Plate Temp [˚C] 2˚C/W 10˚C/W 5 Power Dissipation 18A 15 6 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series 2 8Amp • 120, 240 Vac - AC OUTPUT • Zer o V oltage Switching • 2500 V olt Isolation • Panel M ount • Triac Output CURRENT DERATING CURVES Relays combine small size and high ratings in a package designed for easy heat sink or panel mounting. Standard .187 push-on terminals assure quick connection and are arranged to provide maximum isolation between signal and power circuits. Model S228C is a snubber- less design for applications that require low off-state leakage. Manufactured in Crydom's ISO 9001 Certified facility for optimum product performance and reliability. MODEL NUMBERS S218 S228 S228C Operating Voltage (47-63 Hz) [Vrms] 20-140 40-280 40-280 Max. Load Current Range [Arms] .15-8.0 .15-8.0 .15-8.0 OUTPUT SPECIFICATIONS ➀ 3.6˚C/W 2.5˚C/W Power Dissipation [W] 1¼C/W 65 5¼C/W 8 7.5¼C/W 75 10¼C/W 85 4 95 Max Allowable Base Temp. [˚C] 12 0 2 4 6 8 Load Current [Arms] 20 40 60 80 Max Ambient Temp. [˚C] Transient Overvoltage [Vpk] 400 600 600 Max. Surge Current, (16.6ms) [Apk] 120 120 120 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 Thermal Resistance Junction to Case (RθJC) [ûC/W] Maximum I2 t for Fusing, (8.3 msec.) [A2sec] 1.5 1.5 1.5 60 60 60 Max. Off-State Leakage Current @ Rated Voltage [mA] 4.0 4.0 0.1 Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁ 200 200 200 Max. Turn-On Time 1/2 cycle 1/2 cycle 1/2 cycle Max. Turn-Off Time 1/2 cycle 1/2 cycle 1/2 cycle 0.5 0.5 0.5 Power Factor (Min.) with Max. Load MOUNTING HOLE 0.125 (.300) DIA. INPUT SPECIFICATIONS ➀ 3.5-8.0 OUTPUT 1.50 (38.1) 1.75 (44.4) INPUT + 4 200 Ohm Nominal Input Impedence 2 1 Control Voltage Range 3 .85 (21.6) BASE PLATE .06 (1.5) .562 (14.3) .83 (21.1) .60 (15.2) All dimensions are in inches (millimeters) Max. Turn-On Voltage 3.5 Vdc Min. Turn-Off Voltage 1.0 Vdc Typical Input Current @ 5Vdc 18 mA GENERAL SPECIFICATIONS Dielectric Strength ➁ 2500 Vrms Insulation Resistance (Min.) @ 500 Vdc ➁ 109 Ohm 8.0 pF Max. Capacitance Ambient Operating Temperature Range -30 to 80¼C Ambient Storage Temperature Range -30 to 125¼C M ECHANICAL SPECIFICATIONS Weight: (typical) Encapsulation: GENERAL NOTES APPROVALS UL E116949 CSA LR81689 FastFax Document No.156 SERIES 2. Rev. 111403 PAGE 1 OF 1 ➀ ➁ ➂ 1.3 oz. (40 g) Thermally Conductive Epoxy ©2003 CRYDOM CORP, Specifications subject to change without notice. All parameters at 25¼C unless otherwise specified. Dielectric and insulation resistance are measured between input and output. Off-State dv/dt test method per EIA/NARM standard RS-443. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Series LR 25-40Amp • 120/240/480 Vac - AC OUTPUT • DC or AC Control • Zero Cross and Random Switching • Up to 1200V Transient Capability • SCR Output • PCB Mount Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. • Low Profile OUTPUT SPECIFICATIONS ➀ CURRENT DERATING CURVES 25A 30 100 3˚C/W 2˚C/W 20 15 110 10 5 Base Plate Temp [˚C] 1˚C/W Power Dissipation Operating Voltage Range (47-63 Hz) [Vrms] 24-280 24-280 48-530 48-530 Load Current Range [Arms] 0.15-25 0.15-40 0.15-25 0.15-40 Transient Over-Voltage [Vpk] 600 600 1200 1200 250 400 250 400 Max. I t For Fusing (8.3 msec.) [A sec] 260 660 260 660 Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➂ 500 500 500 500 Max.Off-State Leakage @ Rated Voltage [mArms] 0.1 0.1 0.1 0.1 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 95 25 120 0 5 10 15 20 25 Load Current [Arms] 20 40 60 80 Max Ambient Temp. [˚C] 40A Max. Surge Current Non-Repetitive, (16.6ms) [Apk] 2 2 Max.Turn-On Time 60 .5˚C/W 90 1.5˚C/W 40 100 2˚C/W 110 20 120 ➃ Max. Turn-Off Time Base Plate Temp [˚C] 1˚C/W Power Dissipation LR600240D25 LR600240D40 LR1200480D25 LR1200480D40 LR600240D25R LR600240D40R LR1200480D25R LR1200480D40R Zero Cross Turn-on Random Turn-on MODEL NUMBERS 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle 0.5 Power Factor (Min.) WIth Max. Load INPUT SPECIFICATIONS ➀ 1/2 cycle 120 Vac Control Control Voltage Range Must Turn On Voltage 0.5 ➅ 0.5 0.5 DC Control ➅ 240V AC Control 90-140 Vac 4-32 Vdc 180-260 Vac 90 Vac 4 Vdc 180 Vac 10 Vac 1 Vdc 0 10 20 30 40 50 Load Current [Arms] 20 40 60 80 Max Ambient Temp. [˚C] Must Turn Off Voltage Typical Input Current at 5Vdc ➄ ➅ 15mA@120 Vac 9 mA@ 5 Vdc 10 Vac 11mA@ 240Vac MECHANICAL DIMENSIONS All dimensions are in inches (millimeters) Output - Input + GENERAL SPECIFICATIONS Dielectric Strength ➁ 1.38 (35.0) 1.0 (25.4) AC AC 1.12 (28.4) .78 (19.8) 2500 Vrms Insulation Resistance (Min.) @ 500 Vdc ➁ 10 9 Ohm Max. Capacitance 8.0 pF Ambient Operating Temperature Range -30 to 80˚C Ambient Storage Temperature Range -30 to 125˚C MECHANICAL SPECIFICATIONS 0.5 oz. (14.4 g) Weight: (typical) .050 Typ. (1.2) .500 (12.7) APPROVALS UL (Pending) CSA (Pending) VDE (Pending) Series LR Rev. 111303 PAGE 1 OF 1 .39 (9.8) .25 (6.3) GENERAL NOTES ➀ ➁ ➂ ➃ ➄ ➅ © 2003 CRYDOM CORP, Specifications subject to change without notice. All parameters at 25˚C unless otherwise specified. Dielectric and insulation resistance are measured between input and output. Off-State dv/dt test method per EIA/NARM standard RS-443. Turn on time for random switching models is 0.1 ms (use suffix when ordering random turn on version) DC Input circuitry incorporates active current limiter. Use suffix -120 for 120Vac control and -240 for 240Vac control. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series SMR24-6 25-90Amp • 120/240 Vac - AC OUTPUT condition alarms. Low line voltage, load circuit high impedance, relay output and loss of DC supply current are constantly monitored by this unique Solid State Relay (SSR). • System Monitoring Solid State Relay • LED Status Indicators • Alarm Output Signal • Zero Voltage Switching • Invert/Non Invert Control Inputs and Alarm Outputs The alarm circuit can sink or source 100mA. The sink output is Normally Closed (NPN) and the source output is Normally Open (PNP). Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. The SMR Series of System Monitoring Relays offer the user a number of fault MODEL NUMBERS SMR2425-6 SMR2450-6 SMR2490-6 60-280 60-280 60-280 OUTPUT SPECIFICATIONS ➀ Operating Voltage (47-63 Hz) [Vrms] ➂ [Arms] 25 50 90 Min. Load Current, [mArms] 40 40 40 Transient Overvoltage [Vpk] 600 600 600 Max. Surge Current, (16.6ms) [Apk] 250 625 1200 Max. Load Current Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 Thermal Resistance Junction to Case (R θJC) [˚C/W] Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] 1.02 0.63 0.28 260 1620 6000 10 10 10 Max. Off-State Leakage Current @ Rated Voltage [mArms] ➁ 500 500 500 Max. Turn-On Time 1/2 Cycle 1/2 Cycle 1/2 Cycle Max. Turn-Off Time 1/2 Cycle 1/2 Cycle 1/2 Cycle 0.5 0.5 0.5 Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] Power Factor (Min.) with Max. Load CONTROL SPECIFICATIONS ➀➃ Logic Supply Voltage Range INVERTING NON-INVERTING 8-32 Vdc (pin 3) 8-32 Vdc (pin 3) 8 mA 14 mA (plus pin 8 loading) Input-On Voltage Range 8-32 Vdc (pin 6) 0-1.0 Vdc (pin 5) Input-Off Voltage Range 0-0.4 Vdc (pin 6) 8-32 Vdc (pin 5) 6 mA (pin 6) 1.0 mA (pin 5) Logic Supply Current @ 12 Vdc Input-On Current @ 12 Vdc (Logic Supply) ALARM SPECIFICATIONS ➀➃ NORMALLY CLOSED Supply Voltage (with load) Alarm-On Voltage Open Col. NPN (pin 7) Alarm-Off Voltage Maximum Alarm Output Current Alarm Delay (Min.-Max.) RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 2. ➃ All voltages are positive in respect to common (pin 4). SERIES SMR24-6 Rev. 111803 PAGE 1 OF 2 Supply Voltage (minus 1.0 V) Active High PNP (pin 8) 1.5 Vdc 0.0 Vdc (with load) Active Low NPN (pin 7) Open Col. PNP (pin 8) 100 mA 100 mA 30-100 msec. 30-100 msec. © 2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ All parameters at 25˚C unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard NORMALLY OPEN For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 * Note: * SMR family of relays is not available for purchase in Germany Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series SMR24-6 25-90Amp • 120/240 Vac - AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc Max. Capacitance Input/Output 8 pF Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Thermally Conductive Epoxy Encapsulation: Screws and Saddle Clamps Furnished, Unmounted Output Terminals: Input Connector (locking): Panduit No. MLSS100-6 or Equivalent Mating Connector (supplied): .95 (24.2) 8-32 TERMINAL (2 PLACES ) WIRING DIAGRAM AC 1 OUTPUT AC AC 2.30 .10 (2.54) (58.4) TYP. 1.87 (47.5) Red LED Alarm Status INPUT All dimensions are in inches (millimeters) Screw Torque Requirements: 8-32 Screws - 20in./lbs. (Screws dry without grease.) .025 SQUARE TERMINALS (6 PLACES) 95 90A 10 NO HEATSINK 2˚C/W 110 20 120 0 100 Power Dissipation 110 1.5˚C/W 40 .5˚C/W Base Plate Temp [ºC] 15 Power Dissipation 2˚C/W 90 1˚C/W .5˚C/W Base Plate Temp [ºC] 100 3˚C/W 20 10 15 20 Load Current [Arms] STATUS CHART 25 20 40 60 80 Max Ambient Temp. [ ˚C] Normal Relay OFF Normal Relay ON .2˚C/W .4˚C/W 100 80 1˚C/W 110 40 120 120 NO HEATSINK 0 0 5 90 120 60 1˚C/W Power Dissipation .78 (19.8) 50A 30 5 8 CURRENT DERATING CURVES 25A Logic Supply 8-32 Vdc Common (–) Control Non-Inverting Control Inverting Alarm N/C Alarm N/O 3 Green LED Input Status 1.80 (45.7) 25 AC 2 Base Plate Temp [˚C] 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Panduit No. CT100F22-6 or Equivalent 10 20 30 40 Load Current [Arms] 50 20 40 60 20 80 Relay Fails Shorted Relay Logic Logic Line Line Voltage Load Circuit Supply Supply Loss Fails to Low Voltage High Loss w/Control Turn ON w/Control Low Impedance 40 60 80 Load Current [Arms] Max Ambient Temp. [˚C] 0 20 40 60 80 Max Ambient Temp. [˚C] Relay Fails Shorted Crydom Heat Sinks offer excellent thermal management and are per fectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. LINE VOLTAGE LOAD CURRENT CONTROL INVERTING CONTROL NON-INVERTING GREEN LED LOGIC SUPPLY RED LED & ALARM N/O ALARM N/C © 2003 CRYDOM CORP, Specifications subject to change without notice. APPROVALS UL PENDING CSA PENDING VDE PENDING SERIES SMR24-6 Rev. 111803 PAGE 2 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 * Note: * SMR family of relays is not available for purchase in Germany Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series SMR48-6 25-90Amp • 480 Vac • AC OUTPUT • System Monitoring Solid State Relay • LED Status Indicators • Alarm Output Signal • Zero Voltage Switching • Invert/Non Invert Control Inputs and Alarm Outputs The SMR Series of System Monitoring Relays offer the user a number of fault MODEL NUMBERS condition alarms. Low line voltage, load circuit high impedance, relay output and loss of DC supply current are constantly monitored by this unique Solid State Relay (SSR). The alarm circuit can sink or source 100mA. The sink output is Normally Closed (NPN) and the source output is Normally Open (PNP). Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. SMR4825-6 SMR4850-6 SMR4890-6 96-530 96-530 96-530 25 50 90 40 40 40 Transient Overvoltage [Vpk] 1200 1200 1200 Max. Surge Current, (16.6ms) [Apk] 250 625 1200 OUTPUT SPECIFICATIONS ➀ Operating Voltage (47-63 Hz) [Vrms] Max. Load Current ➂ [Arms] Min. Load Current, [mArms] Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 Thermal Resistance Junction to Case (R θJC) [˚C/W] Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] 1.02 0.63 0.28 260 1620 6000 10 10 10 Max. Off-State Leakage Current @ Rated Voltage [mArms] ➁ 500 500 500 Max. Turn-On Time 1/2 Cycle 1/2 Cycle 1/2 Cycle Max. Turn-Off Time 1/2 Cycle 1/2 Cycle 1/2 Cycle 0.5 0.5 0.5 Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] Power Factor (Min.) with Max. Load CONTROL SPECIFICATIONS ➀➃ Logic Supply Voltage Range INVERTING NON-INVERTING 8-32 Vdc (pin 3) 8-32 Vdc (pin 3) 8 mA 14 mA (plus pin 8 loading) Input-On Voltage Range 8-32 Vdc (pin 6) 0-1.0 Vdc (pin 5) Input-Off Voltage Range 0-0.4 Vdc (pin 6) 8-32 Vdc (pin 5) 6 mA (pin 6) 1.0 mA (pin 5) Logic Supply Current @ 12 Vdc Input-On Current @ 12 Vdc (Logic Supply) ALARM SPECIFICATIONS ➀➃ NORMALLY CLOSED Supply Voltage (with load) Alarm-On Voltage Open Col. NPN (pin 7) Alarm-Off Voltage Maximum Alarm Output Current Alarm Delay (Min.-Max.) RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 2. ➃ All voltages are positive in respect to common (pin 4). SERIES SMR48-6 Rev. 111803 PAGE 1 OF 2 Supply Voltage (minus 1.0 V) Active High PNP (pin 8) 1.5 Vdc 0.0 Vdc (with load) Active Low NPN (pin 7) Open Col. PNP (pin 8) 100 mA 100 mA 30-100 msec. 30-100 msec. © 2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ All parameters at 25˚C unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard NORMALLY OPEN For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 * Note: * SMR family of relays is not available for purchase in Germany Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series SMR48-6 25-90Amp • 480 Vac • AC OUTPUT GENERAL SPECIFICATIONS 4000 Vrms Dielectric Strength 50/60Hz Input/Output/Base 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 8 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Thermally Conductive Epoxy Encapsulation: Screws and Saddle Clamps Furnished, Unmounted Output Terminals: Input Connector (locking): Panduit No. MLSS100-6 or Equivalent Mating Connector (supplied): MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Panduit No. CT100F22-6 or Equivalent .95 (24.2) 8-32 TERMINAL (2 PLACES ) WIRING DIAGRAM AC 1 OUTPUT AC AC 2.30 .10 (2.54) (58.4) TYP. 1.87 (47.5) .025 SQUARE TERMINALS (6 PLACES) .78 (19.8) 90A 50A 95 15 110 10 NO HEATSINK 5 40 90 100 2˚C/W 110 20 120 0 .5˚C/W 1.5˚C/W Power Dissipation 2˚C/W Base Plate Temp [˚C] 100 3˚C/W 20 1˚C/W .5˚C/W 10 15 20 25 STATUS CHART 20 40 60 80 Max Ambient Temp. [˚C] Normal Relay OFF Normal Relay ON 80 100 1˚C/W 110 40 120 120 NO HEATSINK 0 0 Load Current [Arms] .2˚C/W .4˚C/W Power Dissipation 1˚C/W 25 90 120 60 Base Plate Temp [˚C] 30 5 8 CURRENT DERATING CURVES 25A Logic Supply 8-32 Vdc Common (–) Control Non-Inverting Control Inverting Alarm N/C Alarm N/O 3 Green LED Input Status 1.80 (45.7) Power Dissipation Red LED Alarm Status INPUT All dimensions are in inches (millimeters) Screw Torque Requirements: 8-32 Screws - 20in./lbs. (Screws dry without grease.) AC 2 Base Plate Temp [˚C] 1.10 (27.9) .45 (11.4) 10 20 30 40 Load Current [Arms] 50 20 40 60 20 80 Relay Logic Logic Line Line Voltage Load Supply Supply Loss Fails to Low Circuit Voltage Loss w/Control Turn ON w/Control High Low Impedance LINE VOLTAGE LOAD CURRENT CONTROL INVERTING CONTROL NON-INVERTING GREEN LED LOGIC SUPPLY Relay Fails Shorted 40 60 80 Load Current [Arms] Max Ambient Temp. [˚C] 0 20 40 60 80 Max Ambient Temp. [˚C] Relay Fails Shorted Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. RED LED & ALARM N/O ALARM N/C © 2003 CRYDOM CORP, Specifications subject to change without notice. APPROVALS UL PENDING CSA PENDING VDE PENDING FastFax Document No.154 SERIES SMR48-6 Rev. 111803 PAGE 2 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 * Note: * SMR family of relays is not available for purchase in Germany Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series T 10-25Amp • 120/240 Vac - AC OUTPUT • • • • • • Featuring state-of-the-art Surface Mount Technology, these SPST-NO relays deliver proven reliability in the most demanding applications. Zero Voltage Switching Panel Mount 600V Transient Capability Internal Snubber DC or AC Control Triac Output TA1210 TD1210 TA1225 TD1225 TA2410 TD2410 TA2425 TD2425 24-140 24-140 24-280 24-280 10 25 10 25 Min. Load Current, [mArms] 40 40 40 40 Transient Overvoltage [Vpk] 400 400 600 600 Max. Surge Current, (16.6ms) [Apk] 120 250 120 250 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 Thermal Resistance Junction to Case (R θJC) [˚C/W] 1.48 1.02 1.48 1.02 60 260 60 260 8 8 10 10 200 200 200 200 MODEL NUMBERS AC CONTROL D C CONTROL Manufactured in Crydom's ISO 9001 Certified facility for optimum product performance and reliability. OUTPUT SPECIFICATIONS ➀ Operating Voltage (47-63 Hz) [Vrms] Max. Load Current ➂ [Arms] Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] Max. Off-State Leakage Current @ Rated Voltage [mArms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁ Max. Turn-On Time 1/2 Cycle (DC Control), 10.0 msec (AC Control) Max. Turn-Off Time 1/2 Cycle (DC Control), 40.0 msec(AC Control) 0.5 Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ 0.5 0.5 DC CONTROL AC CONTROL Control Voltage Range 3-32 Vdc 90-280 Vrms (60Hz) Max. Reverse Voltage -32 Vdc --- Max. Turn-On Voltage 3.0 Vdc 90 Vrms Min. Turn-Off Voltage 1.0 Vdc 10 Vrms 1500 Ohms 60K Ohms Nominal Input Impedance Typical Input Current 3.4mA @ 5 Vdc, 20mA @ 28Vdc 0.5 2mA @ 120 Vrms, 4mA @ 240 Vrms © 2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ All parameters at 25˚ C unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 3. Series T Rev. 111703 Page 1 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 ¥ FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series T 10-25Amp • 120/240 Vac - AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc Max. Capacitance Input/Output 8 pF Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Thermally Conductive Epoxy Terminals: Screws and Saddle Clamps Furnished, Unmounted MECHANICAL DIMENSIONS All dimensions are in inches (millimeters) 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Screw Torque Requirements: 6-32 Screws - 10 in. lbs., 8-32 Screws - 20in. lbs. (Screws dry without grease.) 8-32 TERMINAL (2 PLACES ) OUTPUT 1 2 1.87 (47.5) -- + 4 3 INPUT 1.00 (25.4) 1.80 (45.7) BASE PLATE .125 (3.2) Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request CrydomÕ s Heat Sink specifica tion sheet for all the details. 2.30 (58.4) 1.70 (43.2) 6-32 TERMINAL (2 PLACES) .78 (19.8) .90 (22.9) CURRENT DERATING CURVES 10A 25A 12 30 110 5˚C/W 8 NO HEATSINK 115 4 120 25 100 3˚C/W 2˚C/W 20 15 110 10 NO HEATSINK 5 0 4 6 8 Load Current [Arms] UL E116949 CSA LR81689 VDE 10143 UG Series T Rev. 111703 PAGE 2 OF 2 120 0 2 APPROVALS Base Plate Temp [˚C] 1˚C/W Power Dissipation Power Dissipation 9˚C/W 95 3˚C/W Base Plate Temp [˚C] 7˚C/W 10 20 40 60 80 Max Ambient Temp. [˚C] 5 10 15 20 Load Current [Arms] 25 20 40 60 80 Max Ambient Temp. [˚C] © 2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 ¥ FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series PRG 150Amp • 120/240, 480 Vac - AC OUTPUT • Zero Voltage and Random Turn-On Swi tching • Extra High Steady-Stat e Current • Panel M ount • Internal Snubber DC CONTROL AC CONTROL Featuring state-of-the-art Surface Mount Technology, this SPST-NO relay delivers proven reliability in the most demanding applications. Output consists of an SCR AC switch and is available in zero-cross and random turn-on (phase controllable) versions. Manufactured in Crydom's ISO 9001 Certified facility for optimum product performance and reliability. PRGD24150 PRGA24150 PRGD48150 PRGA48150 Operating Voltage (47-63 Hz) [Vrms] 24-280 48-530 Load Current Range ➂ [Arms] .15-150 .15-150 600 1200 1750 1750 1.7 1.7 0.15 12,700 0.15 12,700 MODEL NUMBERS OUTPUT SPECIFICATIONS ➀ Transient Overvoltage [Vpk] Max. Surge Current, (16.6ms) [Apk] Max. On-State Voltage Drop @ Rated Current [Vpk] Thermal Resistance Junction to Case (RθJC) [ûC/W] Maximum I2 t for Fusing, (8.3 msec.) [A2sec] Max. Off-State Leakage Current @ Rated Voltage [mArms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁ 5 500 5 500 Max. Turn-On Time ➃ 1/2 cycle (DC Control), 10 msec (AC Control) Max. Turn-Off Time 1/2 cycle (DC Control), 40 msec (AC Control) Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ DC(240V Models) 0.5 0.5 DC(480V Models) AC Control Voltage Range 3-15 Vdc 4-15 Vdc 90-140 Vac Max. Turn-On Voltage 3.0 Vdc 4.0 Vdc 90 Vac Min. Turn-Off Voltage Nominal Input Impedance Typical Input Current 1.0 Vdc 300 Ohms 15 mA @ 5 Vdc 1.0 Vdc 300 Ohms 15 mA @ 5 Vdc 10 Vac 14.1K Ohms 10 mA @ 120 Vac © 2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ All parameters at 25˚C and per section unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, see derating curves on page 2. ➃ Turn-On time for Random versions is 0.02 msec. (DC Control Models). FastFax Document No. 153 PRG. Rev. 111403 PAGE 1 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series PRG 150Amp • 120/240, 480 Vac - AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength (min.) 4000 Vac Insulation Resistance (Min.) @ 500 Vdc 1010Ohm Max. Capacitance Input/Output 10 pF Ambient Operating Temperature Range -30 to 80˚C Ambient Storage Temperature Range -40 to 125˚C M ECHANICAL SPECIFICATIONS Weight: (typical) 12 oz. (340g) Thermally Conductive Epoxy Encapsulation: Power Terminals: M5 Screws Furnished, Mounted Control Terminals: .050 x .020 Square Pins .125" Copper Base Plate (Integral Part of Package) CURRENT DERATING CURVES .30 (7.6) 150A Power Dissipation 120 110 90 1˚C/W 60 115 30 120 0 30 60 90 120 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom's Heat Sink specification sheet for all the details. -- + AC 2.50 (63.5) MOUNTING HOLE/SLOT 0.16 (4.1) DIA. INPUT OUTPUT 100 .4˚C/W .2˚C/W .5˚C/W 105 150 .25 (6.3) 1.66 (42.2) AC 180 Base Plate Temp [˚C] 210 .125 (3.2) .95 (24.1) 1.17 (29.7) .20 (5.1) .20 (5.1) .65 (16.5) 2.50 (63.5) 3.60 (91.4) 4.00 (101.5) PIN DETAIL .055 (1.4) CUT HERE FOR FASTON (AMP TYPE 61060-1 RECOMMEND) .110 x .020 THICK .400 (10.2) All dimensions are in inches (millimeters) AVAILABLE OPTIONS -10 Random Turn-On (AC & DC Control) Phase Controllable (DC Control) Example: PRGA24 150-10 APPROVALS PENDING FastFax Document No. 153 PRG. Rev. 111403 PAGE 2 OF 2 ©2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Series PS 10-90Amp • 120/240 Vac - AC OUTPUT • • • • • Peak Switching Panel Mount 600V Transient Capability Internal Snubber Input Status Indicator Option Available Output consists of an SCR AC switch turning ON at the next peak of sinusoidal AC wave form after the input has been activated. Continuing to conduct normally until the input is de-activated and then turning off at the next current zero cross Suitable for switching of transformers and other highly inductive loads where significant inrush current may otherwise cause problems. Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. Featuring state-of-the-art Surface Mount Technology, these SPST-NO relays deliver proven reliability in the most demanding applications. MODEL NUMBER PSD2410 PSD2425 PSD2450 PSD2490 90-280 90-280 90-280 90-280 10 25 50 90 Min. Load Current, [mArms] 40 40 40 40 Transient Overvoltage [Vpk] 600 600 600 600 Max. Surge Current, (16.6ms) [Apk] 120 250 625 1200 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 Thermal Resistance Junction to Case (R θJC) [˚C/W] 1.48 1.02 0.63 0.28 Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] 60 260 1620 6000 Max. Off-State Leakage Current @ Rated Voltage [mArms] 10 10 10 10 500 500 500 500 OUTPUT SPECIFICATIONS ➀ Operating Voltage (47-63 Hz) [Vrms] Max. Load Current ➂ [Arms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁ Max. Turn-On Time 1/2 Cycle Max. Turn-Off Time 1/2 Cycle Power Factor (Min.) with Max. Load 0.5 0.5 0.5 0.5 INPUT SPECIFICATIONS ➀ Control Voltage Range 3-32 Vdc Max. Reverse Voltage -32 Vdc Max. Turn-On Voltage 3.0 Vdc Min. Turn-Off Voltage 1.0 Vdc See Note ➃ Nominal Input Impedance 2mA ➃ Typical Input Current © 2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ All parameters at 25˚ C unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 3. ➃ Input circuit incorporates active current limiter. SERIES PS Rev. 111403 PAGE 1 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Series PS 10-90Amp • 120/240 Vac - AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 8 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS 3.0 oz. (86.5g) Weight: (typical) Encapsulation: Thermally Conductive Epoxy Terminals: Screws and Saddle Clamps Furnished, Unmounted MECHANICAL OUTLINE Screw Torque Requirements: 6-32 Screws - 10 in. lbs. max. 8-32 Screws - 20in. lbs. max. (Screws dry without grease.) AVAILABLE OPTIONS G Input Status Indicator Example: PSD2425G 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 8-32 TERMINAL (2 PLACES ) Note: Control Voltage Range 4.5-32Vdc 1 OUTPUT Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. -- + 4 3 INPUT 1.00 (25.4) 1.80 (45.7) BASE PLATE .125 (3.2) 6-32 TERMINAL (2 PLACES) 10A 25A 12 30 110 5˚C/W 8 NO HEATSINK 115 4 120 25 100 3˚C/W 2˚C/W 20 15 110 10 NO HEATSINK 5 0 120 0 4 6 8 Load Current [Arms] 10 20 40 60 80 5 Max Ambient Temp. [˚C] 10 15 20 50A .5˚C/W 90 100 2˚C/W 110 20 40 APPROVALS UL/cUL E116950 50 80 20 40 60 90 .2˚C/W .4˚C/W 80 80 Max Ambient Temp. [˚C] 100 1˚C/W 110 40 120 NO HEATSINK 0 30 60 .5˚C/W Power Dissipation 1.5˚C/W 40 20 40 120 Base Plate Temp [˚C] 1˚C/W Load Current [Arms] 20 Max Ambient Temp. [˚C] 90A 60 10 25 Load Current [Arms] Base Plate Temp [˚C] 2 Power Dissipation Base Plate Temp [˚C] 1˚C/W Power Dissipation 9˚C/W 95 3˚C/W Base Plate Temp [˚C] 7˚C/W SERIES PS Rev. 111403 PAGE 2 OF 2 .78 (19.8) .90 (22.9) All dimensions are in inches (millimeters) CURRENT DERATING CURVES Power Dissipation 2.30 (58.4) 1.70 (43.2) 2 1.87 (47.5) 120 0 20 40 60 80 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] © 2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com G2 Series/ 1 FORM A Solid State Relays Model Number Parameters Input Characteristics G2-1A02 G2-1A03 G2-1A05 G2-1A06 G2-1A07 Sym. Test Conditions Units LED Forward Current - Turn on IFon IL = 100mA, t = 10ms mADC Max Typ LED Forward Current - Turn off IFoff IL = 0.2mA, VL = (Note 1) mADC Min Typ Recommended Forward Current IF mADC Min Max LED Forward Voltage VF IF = 20mA VDC 1 Form A 1 Form A 1 Form A 1 Form A 1 Form A Max 5.0 2.0 0.1 1.8 10 30 1.1 1.4 5.0 2.0 0.1 1.8 10 30 1.1 1.4 5.0 2.0 0.1 1.8 10 30 1.1 1.4 5.0 2.0 0.1 1.8 10 30 1.1 1.4 5.0 2.0 0.1 1.8 10 30 1.1 1.4 Max Min Maximum Input Ratings LED Forward Current IF 50 50 50 50 50 LED Reverse Voltage Withstand VR IR = 10mA Max 10 10 10 10 10 Switching Voltage VL IL = 50mA V PEAK Max 400 400 400 250 150 Switching Current: AC Mode(Note2) IL Pin 4 to Pin 6 mA Max Switching Current: DC Mode(Note2) Current Limit: AC Mode(Note2) Current Limit: DC Mode(Note2) On Resistance: AC Mode(Note2) On Resistance: DC Mode(Note2) IL Pins 5(-) to Pins 4&6 (+) mA Max Typ 150 250 380 540 24 6 0.5 5000 200 0.5 1 5.0 1.0 95 10 0.2 150 250 n/a n/a 18 4.5 0.5 5000 200 0.5 1 5.0 1.0 95 10 0.2 120 200 380 540 35 8.75 0.5 5000 200 0.5 1 5.0 1.0 60 7 0.2 150 250 380 760 18 4.5 0.5 5000 200 0.5 1 5.0 1.0 110 15 0.2 450 900 n/a n/a 5 1.25 0.5 5000 200 0.5 1 5.0* 1.0 170 30 0.2 3750 0.8 500 3750 0.8 500 3750 0.8 500 3750 0.8 500 3750 0.8 600 mADC Output Characteristics Off State Resistance ILmt IF = 5mA, t = 5ms mA ILmt IF = 5mA, t = 5ms mA Typ Ron IF = 5mA, IL = 50mA W Max Ron IF = 5mA, IL = 50mA W Max Roff IF = 0mA, VL = 100V GW Min Typ Ioff IF = 0mA, VL = 100V nA Ioff IF = 0mA, VL = Max mA Max Typ Max Ton IF = 5mA, IL = 50mA ms Max Toff IF = 5mA, IL = 50mA ms Max IF = 0mA, VL = 1V pF Typ IF = 0mA, VL = 50V pF Typ IF = 5mA mV Typ t = 60sec VRMS Min pF Typ mW Max Off State Leakage Turn On Time Turn Off Time Capacitance - Across Output Thermal Offset Voltage General Characteristics Dielectric Strength - Input to Output Capacitance - Input to Output Power Dissipation Notes: PDiss 1: VL for LED Forward Current - Turn Off is 50 Volts less than "Switching Voltage : Max". 2: See "AC Mode and DC Mode Operation" on Page 67 for further description of AC and DC Mode. 3: Specifications subject to change without notice. * I F = 10mA For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH. MOSFET Breakdown Voltage (Volts) G2 Series/ 1 FORM A Load Current (mA) 300 250 I(F) = 5 mA 200 150 100 G2-1A02 G2-1A03 G2-1A06 50 G2-1A05 G2-1A07 450 G2-1A02 G2-1A03 G2-1A05 G2-1A06 400 350 I(F) = 0 mA G2-1A07 300 250 0 200 -40 -20 0 20 40 60 80 -40 -20 0 20 Temperature (Deg. C) 40 60 80 Temperature (Deg. C) A. Load Current vs. Ambient Temperature B. Output MOSFET BV vs. Ambient Temperature 250 G2-1A05 G2-1A02 G2-1A03 G2-1A06 G2-1A06 50% G2-1A05 200 CapacitancerF) ( Change in On Resistance (%) Normalized to 25 ° C 70% G2-1A07 30% 10% -10% I(F) = 5 mA I(L) = 50 mA -30% G2-1A02 G2-1A03 G2-1A06 G2-1A07 100 50 0 -40 -20 0 20 40 Temperature (Deg. C) 60 0 80 250% 200% Change in Turn Off Time (% ) Normalized to 25 ° C 115% G2-1A02 G2-1A03 G2-1A05 G2-1A06 G2-1A06 I(F) = 5 mA I(L) = 50 mA 150% 100% G2-1A07 50% 40 60 80 100 120 D. Output Capacitance vs. Applied Voltage 350% 300% 20 Bias Voltage (Volts) C. On-Resistance vs. Ambient Temperature Change in Turn On Time (%) Normalized to 25 ° C I(F) = 0 mA f = 1 MHz T= 25 deg. C 150 -50% 0% G2-1A02 G2-1A03 G2-1A06 95% 75% 55% G2-1A05 G2-1A07 35% 15% -5% I(F) = 5 mA I(L) = 50 mA -25% -45% -50% -65% -100% -40 -20 0 20 40 60 -40 80 -20 0 Temperature (Deg. C) 20 40 60 80 Temperature (Deg. C) F. Turn Off Time vs. Ambient Temperature E. On Time vs. Ambient Temperature 8000 90 G2-1A02 G2-1A03 G2-1A05 T = 25 deg. C I(L) = 50 mA 6000 5000 G2-1A06 4000 G2-1A07 80 Turn Off Time (mSec. ) 7000 Turn On Time m ( Sec.) Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 3000 2000 T = 25 deg. C I(L) = 50 mA 70 60 G2-1A02 G2-1A03 G2-1A05 50 G2-1A06 40 1000 G2-1A07 30 0 0 5 10 15 20 25 30 35 40 45 50 LED Forward Current (mA) G. Turn On Time vs. LED Forward Current For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 55 0 5 10 15 20 25 30 35 40 45 50 55 LED Forward Current (mA) H. Turn Off Time vs. LED Forward Current UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH. Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com G2 Series/ DUAL FORM A Solid State Relays Model Number Parameters Input Characteristics Sym. Test Conditions Units LED Forward Current - Turn on IFon IL = 100mA, t = 10ms mADC Max Typ LED Forward Current - Turn off IFoff IL = 0.2mA, VL = (Note 1) mADC Min Typ mADC Min Max Recommended Forward Current IF LED Forward Voltage VF IF = 20mA VDC G2-DA01 G2-DA02 G2-DA03 G2-DA06 Dual Form A Dual Form A Dual Form A Dual Form A Max 5.0 2.0 0.1 1.8 10 30 1.1 1.4 5.0 2.0 0.1 1.8 10 30 1.1 1.4 5.0 2.0 0.1 1.8 10 30 1.1 1.4 5.0 2.0 0.1 1.8 10 30 1.1 1.4 Min Maximum Input Ratings LED Forward Current IF mADC Max 50 50 50 50 LED Reverse Voltage Withstand VR IR = 10mA VDC Max 10 10 10 10 Switching Voltage VL IL = 50mA V PEAK Max 400 400 400 250 Switching Current IL 120 70 380 180 125 n/a 180 125 380 Output Characteristics Current Limit ILmt IF = 5mA, t = 5ms mA Typ 150 110 380 On Resistance Ron IF = 5mA, IL = 50mA W Max 24 35 18 18 Off State Resistance Roff IF = 0mA, VL = 100V GW Min Typ 0.5 5000 0.5 5000 0.5 5000 0.5 5000 Ioff IF = 0mA, VL = 100V nA 200 0.5 1 5.0 200 0.5 1 5.0 200 0.5 1 5.0 200 0.5 1 5.0 1.0 95 10 0.2 1.0 60 7 0.2 1.0 95 10 0.2 1.0 110 5 1 0.2 3750 1.2 600 3750 1.2 600 3750 1.2 600 3750 1.2 600 Each Channel mA Max Both Ch's Simultaneously mA Max Ioff IF = 0mA, VL = Max mA Max Typ Max Turn On Time Ton IF = 5mA, IL = 50mA ms Max Turn Off Time Toff IF = 5mA, IL = 50mA ms Max IF = 0mA, VL = 1V IF = 0mA, VL = 50V pF pF Typ Typ IF = 5mA mV Typ t = 60sec VRMS Min Off State Leakage Capacitance - Across Output Thermal Offset Voltage General Characteristics Dielectric Strength - Input to Output Capacitance - Input to Output Power Dissipation PDiss pF Typ mW Max Notes: 1: VL for LED Forward Current - Turn Off is 50 Volts less than "Switching Voltage : Max". 2: Specifications subject to change without notice. Schematic Top View: Mold mark on top of relay indicates Pin #1 For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH. Page 1 of 2 G2 Series/ DUAL FORM A MOSFET Breakdown Voltage (Volts 200 180 Load Current (mA) 160 140 120 100 G2-DA01 G2-DA03 G2-DA02 80 60 40 I(F) = 5 mA G2-DA06 20 475 425 -40 I(F) = 0 mA 325 275 -20 0 20 40 Temperature (Deg. C) 60 -40 80 -20 0 20 60 80 B. Output MOSFET BV vs. Ambient Temperature 60% 160 G2-DA01 G2-DA03 G2-DA06 G2-DA02 20% G2-DA02 140 I(F) = 0 mA f = 1 MHz T = 25 deg. C 120 CapacitancerF) ( 40% 0% -20% 100 G2-DA01 G2-DA03 G2-DA06 80 60 40 I(F) = 5 mA I(L) = 50 mA -40% 20 0 -60% -40 -20 0 20 40 60 0 80 20 40 60 80 100 120 Bias Voltage (Volts) Temperature (Deg. C) C. On-Resistance vs. Ambient Temperature D. Output Capacitance vs. Applied Voltage 140% 140% 120% 120% G2-DA01 G2-DA02 G2-DA03 G2-DA06 100% 80% 60% Change in Turn Off Time (% ) Normalized to 25° C Change in Turn On Time (%) Normalized to 25° C 40 Temperate (Deg. C) A. Load Current vs. Ambient Temperature Change in On Resistance (%) Normalized to 25° C G2-DA01 G2-DA02 G2-DA03 G2-DA06 375 225 0 I(F) = 5 mA I(L) = 50 mA 40% 20% 0% -20% -40% G2-DA01 G2-DA03 G2-DA06 G2-DA02 100% 80% 60% I(F) = 5 mA I(L) = 50 mA 40% 20% 0% -20% -40% -60% -60% -80% -40 -20 0 20 40 60 -40 80 -20 0 Temperature (Deg. C) 20 40 60 80 Temperature (Deg. C) F. Turn Off Time vs. Ambient Temperature E. On Time vs. Ambient Temperature 90 5000 G2-DA01 G2-DA03 G2-DA02 T = 25 deg. C I(L) = 50 mA 4000 80 Turn Off Time (mSec.) Turn On Time m ( Sec.) Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com G2-DA06 3000 2000 70 60 1000 40 0 30 0 5 10 15 20 25 30 35 40 45 50 LED Forward Current (mA) G. Turn On Time vs. LED Forward Current For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 55 G2-DA01 G2-DA03 G2-DA02 50 T = 25 deg. C I(L) = 50 mA 0 5 10 15 20 25 30 G2-DA06 35 40 45 50 55 LED Forward Current (mA) H. Turn Off Time vs. LED Forward Current UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH. Page 2 of 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com G2 Series/ 2 FORM A Solid State Relays Model Number Parameters Input Characteristics G2-2A03 2 Form A Sym. Test Conditions Units LED Forward Current - Turn on IFon IL = 100mA, t = 10ms ADC m Max Typ 10 3.4 LED Forward Current - Turn off IFoff IL = 0.2mA, VL = (Note 1) ADC m Min Typ Recommended Forward Current IF ADC m Min Max VD C Min Max 0.1 3.0 15 40 1.1 1.4 LED Forward Voltage IF = 20mA VF Maximum Input Ratings LED Forward Current LED Reverse Voltage Withstand IF ADC m Max VR IR = 10mA VDC Max Switching Voltage Switching Current VL IL = 50mA V PEAK Max IL Current Limit ILmt Each Channel Both Ch.'s Simultaneously IF = 5mA, t = 5ms mA mA mA Max Max Min On Resistance Off State Resistance Ron IF = 5mA/0mA, IL = 50mA W Max Roff IF = 0mA, VL = 15V GW Min Typ Ioff IF = 0mA, VL = 15V nA Max Typ 50 10 Output Characteristics Max Off State Leakage Ioff IF = 0mA, VL = Max mA Max Turn On Time Ton IF = 10mA, IL = 50mA ms Max Turn Off Time Capacitance Across Output Toff IF = 10mA, IL = 50mA ms Max IF = 0mA, VL = 1V pF Typ IF = 0mA, VL = 50V pF Typ IF = 10mA mV Typ t = 60sec VRMS Min Thermal Offset Voltage 15 250 150 n/a n/a 8 0.5 5000 200 0.5 1 1.5 . 0.5 40 0.2 General Characteristics Dielectric Strength - Input to Output Capacitance - Input to Output Power Dissipation PDiss pF Typ mW Max 3750 1.2 600 Notes: 1: VL for LED Forward Current - Turn Off is 50 Volts less than "Switching Voltage Max". 2: Specifications subject to change without notice. * I F = 10mA Schematic Top View: Mold mark on top of relay indicates Pin #1 Package Drawings on Page 3 For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH. Page 1 of 2 MOSFET Breakdown Voltage (Volts) G2 Series/ 2 FORM A Load Current (mA) 250 200 150 100 G2-2A03 I(F) = 5 mA 50 0 500 450 400 350 300 250 200 G2-2A03 I(F) = 0 mA 150 100 50 0 -40 -20 0 20 40 60 80 -40 -20 0 Temperature (Deg C) Change in On Resistance (%) Normalized to 25° C 20 40 60 80 Temperature (Deg C) A. Load Current vs. Ambient Temperature B. Output MOSFET BV vs. Ambient Temperature 140% G2-2A03 115% I(F) = 5 mA I(L) = 50 mA 90% 65% 40% 15% -10% -35% -60% -40 -20 0 20 40 60 80 Temperature (Deg C) C. On-Resistance vs. Ambient Temperature 240% G2-2A03 Change in Turn Off Time (% ) Normalized to 25° C Change in Turn On Time (%) Normalized to 25° C 140% I(F) = 5 mA I(L) = 50 mA 190% 140% 90% 40% -10% -60% -40 -20 0 20 40 60 G2-2A03 90% 40% -10% I(F) = 5 mA I(L) = 50 mA -60% -110% 80 -40 -20 0 Temperature (Deg C) 20 40 60 80 Temperature (Deg C) D. On Time vs. Ambient Temperature E. Turn Off Time vs. Ambient Temperature 90 5000 T = 25 deg. C I(L) = 50 mA 4000 Turn Off Time (mSec.) 80 Turn On Time (mSec.) Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com G2-2A03 3000 2000 1000 T = 25 deg. C I(L) = 50 mA 70 60 50 G2-2A03 40 0 30 0 5 10 15 20 25 30 35 40 45 50 55 LED Forward Current (mA) F. Turn On Time vs. LED Forward Current For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 0 5 10 15 20 25 30 35 40 45 50 55 LED Forward Current (mA) G. Turn Off Time vs. LED Forward Current UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH. Page 2 of 2 Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com G2 Series/ FORM B Solid State Relays Model Number Parameters Input Characteristics Sym. Test Conditions Units LED Forward Current - Turn on IFon IL = 100mA, t = 10ms mADC Max Typ LED Forward Current - Turn off IFoff IL = 0.2mA, VL = (Note 1) mADC Min Typ mADC Min Max Recommended Forward Current LED Forward Voltage IF VF G2-1B01 G2-1B02 G2-DB01 1 Form B 1 Form B Dual Form B G2-DB02 Dual Form B Max 5.0 3.0 0.1 1.8 10 30 1.1 1.4 5.0 3.0 0.1 1.8 10 30 1.1 1.4 5.0 3.0 0.1 1.8 10 30 1.1 1.4 5.0 3.0 0.1 1.8 10 30 1.1 1.4 mADC Max 50 50 50 50 VDC Max 10 10 10 10 350 250 350 250 165 330 200 400 170 120 200 140 20 5.0 0.1 1.4 0.07 1.0 1.0 5.0 1.0 200 20 0.2 13 3.25 0.1 1.4 0.07 1.0 1.0 5.0 1.0 170 25 0.2 20 n/a 0.1 1.4 0.07 1.0 1.0 5.0 1.0 200 20 0.2 13 n/a 0.1 1.4 0.07 1.0 1.0 5.0 1.0 170 25 0.2 3750 0.8 500 3750 0.8 500 3750 1.2 600 3750 1.2 600 IF = 20mA VDC Min Maximum Input Ratings LED Forward Current IF LED Reverse Voltage Withstand VR IR = 10mA Switching Voltage VL IL = 50mA Switching Current IL Output Characteristics V PEAK Max (Note 2) mA Max (Note 3) mA Max On Resistance (Note 2) On Resistance (Note 4) Ron IF = 5mA, IL = 50mA W Max Ron IF = 5mA, IL = 50mA W Max Off State Resistance Roff IF = 0mA, VL = 100V GW Min Typ Ioff IF = 0mA, VL = 100V µA Ioff IF = 0mA, VL = Max µA Max Typ Max Ton IF = 5mA, IL = 50mA ms Max Toff IF = 5mA, IL = 50mA ms Max IF = 0mA, VL = 1V pF Typ IF = 0mA, VL = 50V pF Typ IF = 5mA µV Typ t = 60sec VRMS pF Min Typ mW Max Off State Leakage Turn On Time Turn Off Time Capacitance - Across Output Thermal Offset Voltage General Characteristics Dielectric Strength - Input to Output Capacitance - Input to Output Power Dissipation Notes: PDiss 1: VL for LED Forward Current - Turn off is 50 Volts less than "Switching Voltage : Max" 2: For G2-1B01 and G2-1B02: Output connected to pins 4 and 6. For G2-DB01 and G2-DB02: Each channel. 3: For G2-1B01 and G2-1B02: Output connected to pin 5(-) and pins 4 & 6(+). For G2-DB01 and G2-DB02: Both channels switching simultaneously 4: For G2-1B01 and G2-1B02: Output connected to pin 5(-) and pins 4 & 6(+). 5: Specifications subject to change without notice * IF = 10mA Schematic Top View: Mold mark on top of relay indicates Pin #1 For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH. Page 1 of 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 150 100 G2-1B02 G2-DB02 I(F) = 0 mA G2-1B01 50 600 MOSFET Breakdown Voltage (Volts) Load Current (mA) 200 G2-DB01 550 500 G2-1B02 G2-DB02 450 400 300 250 -40 -20 0 20 40 60 80 -40 -20 0 20 Temperature (Deg. C) 60 80 B. Output MOSFET BV vs. Ambient Temperature 350.00 50% 40% G2-1B02 G2-DB02 G2-1B01 G2-DB01 20% 300.00 CapacitancerF) ( 30% 10% 0% -10% I(F) = 0 mA I(L) = 50 mA -20% G2-1B02 G2-DB02 I(F) = 5 mA f = 1 MHz T = 25 deg. C 250.00 200.00 G2-1B01 G2-DB01 150.00 100.00 50.00 -30% -40% 0.00 -40 -20 0 20 40 60 80 0 20 40 60 Temperature (Deg. C) 80 100 120 Bias Voltage (Volts) C. On-Resistance vs.Ambient Temperature D. Output Capacitance vs. Applied Voltage 200% 120% 150% G2-1B01 G2-1B02 G2-DB01 G2-DB02 100% 100% Change in Turn Off Time (% ) Normalized to 25° C Change in Turn On Time (%) Normalized to 25° C 40 Temperature (Deg. C) A. Load Current vs. Ambient Temperature Change in On Resistance (%) Normalized to 25° C G2-1B01 G2-DB01 I(F) = 5 mA 350 0 I(F) = 5 mA I(L) = 50 mA 50% 0% -50% G2-1B02 G2-DB02 G2-1B01 G2-DB01 80% 60% I(F) = 5 mA I(L) = 50 mA 40% 20% 0% -20% -40% -60% -100% -80% -40 -20 0 20 40 60 80 -40 -20 0 Temperature (Deg. C) 20 40 60 80 Temperature (Deg. C) E. On Time vs. Ambient Temperature F. Turn Off Time vs. Ambient Temperature 9000 55 8000 6000 50 G2-1B02 G2-DB02 T = 25 deg. C I(L) = 50 mA 7000 Turn Off Time (mSec.) Turn On Time m ( Sec.) Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com G2 Series/ FORM B G2-1B01 G2-DB01 5000 4000 3000 2000 45 40 35 30 G2-1B02 G2-DB02 G2-1B01 G2-DB01 T = 25 deg. C I(L) = 50 mA 25 20 1000 15 0 0 5 10 15 20 25 30 35 40 45 50 LED Forward Current (mA) G. Turn On Time vs. LED Forward Current For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 0 5 10 15 20 25 30 35 40 45 50 LED Forward Current (mA) H. Turn Off Time vs. LED Forward Current UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH. Page 2 of 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com G2 Series/ 1A/1B Solid State Relays Model Number Parameters Input Characteristics LED Forward Current - Turn on LED Forward Current - Turn off Recommended Forward Current LED Forward Voltage Sym. G2-AB01 1A/1B G2-AB02 1A/1B Max Typ 5.0 2.0 5.0 2.0 mADC Min Typ mADC Min Max VDC Min Max 0.1 1.8 10 30 1.1 1.4 0.1 1.8 10 30 1.1 1.4 50 10 50 10 400 150 110 380 24 0.5 5000 0.5 5000 200 0.17 1 0.02 1 1 5.0 1.0 0.2 250 200 150 380 13 0.5 5000 0.5 5000 200 0.17 1 0.02 1 1 5.0 1.0 0.2 3750 1.2 600 3750 1.2 600 Test Conditions Units IFon IL = 100mA, t = 10ms mADC IFoff IL = 0.2mA, VL = (Note 1) IF IF = 20mA VF Maximum Input Ratings LED Forward Current LED Reverse Voltage Withstand IF VR mADC Max IR = 10mA VDC Max IL = 50mA V PEAK Max mA mA Max Max mA Typ W Max Output Characteristics Switching Voltage Switching Current Current Limit: N.O. Channel Only On Resistance Off State Resistance: N.O. Channel Off State Resistance: N.C. Channel Off State Leakage: N.O. Channel Off State Leakage: N.C. Channel Turn On Time Turn Off Time Thermal Offset Voltage VL IL ILmt Ron Each Channel Both Ch.'s Simultaneously IF = 5mA, t = 5ms IF = 5mA/0mA, IL = 50mA Roff IF = 0mA, VL = 100V GW Min Typ Roff IF = 5mA, VL = 100V GW Min Typ Ioff IF = 0mA, VL = 100V nA Max Typ Ioff IF = 0mA, VL = Max mA Max Ioff IF = 5mA, VL = 100V mA Ioff IF = 5mA, VL = Max mA Max Typ Max Ton IF = 5mA, IL = 50mA ms Max Toff IF = 5mA, IL = 50mA ms Max IF = 5mA mV Typ t = 60sec VRMS Min pF Typ mW Max General Characteristics Dielectric Strength - Input to Output Capacitance - Input to Output Power Dissipation PDiss Notes: 1: VL for LED Forward Current - Turn Off is 50 Volts less than "Switching Voltage Max". 2: Specifications subject to change without notice. * I F = 10mA Schematic Top View: Mold mark on top of relay indicates Pin #1 Package Drawings on Page 3 For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH. Page 1 of 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1A/1B *See page 3 for characteristic curves of normally closed switches MOSFET Breakdown Voltage (Volts) 200 180 Load Current (mA) 160 140 120 100 G2-AB01 80 60 NO I(F) = 5 mA NC I(F) = 0 mA G2-AB02 40 20 0 500 450 NO G2-AB01 400 350 300 250 -20 0 20 40 60 80 -40 -20 0 Temperature (Deg C) 20 60 80 B. Output MOSFET vs. Ambient Temperature 60% 160 40% 140 NO G2-AB01 G2-AB02 120 CapacitancerF) ( 20% 0% -20% -40% NO G2-AB01 G2-AB02 I(F) = 0 mA f = 1 MHz T = 25 deg. C 100 80 60 40 I(F) = 5 mA I(L) = 50 mA 20 0 -60% -40 -20 0 20 40 60 0 80 10 20 30 40 Temperature (Deg C) 50 60 70 80 90 100 110 Bias Voltage (Volts) C. On-Resistance vs. Ambient Temperature D. Output Capacitance vs. Applied Voltage 140% 140% 120% 120% NO G2-AB01 G2-AB02 100% 80% Change in Turn Off Time (% ) Normalized to 25° C Change in Turn On Time (%) Normalized to 25° C 40 Temperature (Deg C) A. Load Current vs. Ambient Temperature Change in On Resistance (%) Normalized to 25° C NO G2-AB02 I(F) = 0 mA 200 -40 I(F) = 5 mA I(L) = 50 mA 60% 40% 20% 0% -20% 100% NO G2-AB01 G2-AB02 80% 60% I(F) = 5 mA I(L) = 50 mA 40% 20% 0% -20% -40% -40% -60% -60% -80% -40 -20 0 20 40 60 80 -40 -20 0 Temperature (Deg C) 20 40 60 80 Temperature (Deg C) E. On Time vs. Ambient Temperature F. Turn Off Time vs. Ambient Temperature 100 5000 NO G2-AB01 4000 90 Turn Off Time (mSec.) Turn On Time (mSec.) Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com G2 Series/ T = 25 deg. C I(L) = 50 mA 3000 NO G2-AB02 2000 1000 T = 25 deg. C I(L) = 50 mA 80 70 60 NO G2-AB01 50 NO G2-AB02 40 30 0 0 5 10 15 20 25 30 35 40 45 50 55 LED Forward Current (mA) G. Turn On Time vs. LED Forward Current For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 0 5 10 15 20 25 30 35 40 45 50 55 LED Forward Current (mA) H. Turn Off Time vs. LED Forward Current UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH. Page 2 of 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1A/1B MOSFET Breakdown Voltage (Volts) 600 550 500 NC G2-AB02 450 I(F) = 5 mA 400 NC G2-AB01 350 300 250 -40 -20 0 20 40 60 80 Temperature (Deg. C) I. Output MOSFET BV vs. Ambient Temperature 350 40% NC G2-AB02 30% 20% 300 CapacitancerF) ( Change in On Resistance (%) Normalized to 25 ° C 50% NC G2-AB01 10% 0% -10% I(F) = 0 mA I(L) = 50 mA -20% I(F) = 5 mA f = 1 MHz T = 25 deg. C 250 200 NC G2-AB01 150 100 -40% 0 -40 -20 0 20 40 60 80 0 10 20 30 40 Temperature (Deg. C) 50 60 70 80 90 100 110 Bias Voltage (Volts) K. Output Capacitance vs. Applied Voltage J. On-Resistance vs. Ambient Temperature 200% 120% 100% NC G2-AB02 150% 100% Change in Turn Off Time (% ) Normalized to 25 D C Change in Turn On Time (%) Normalized to 25 ° C NC G2-AB02 50 -30% I(F) = 5 mA I(L) = 50 mA NC G2-AB01 50% 0% -50% NC G2-AB02 80% 60% NC G2-AB01 40% I(F) = 5 mA I(L) = 50 mA 20% 0% -20% -40% -60% -100% -80% -40 -20 0 20 40 60 80 -40 -20 0 Temperature (Deg. C) 20 40 60 80 Temperature (Deg. C) L. On Time vs. Ambient Temperature M. Turn Off Time vs. Ambient Temperature 4500 55.00 4000 NC G2-AB02 3500 T = 25 deg. C I(L) = 50 mA 3000 Turn Off Time (mSec.) Turn On Time (mSec.) Courtesy of Steven Engineering, Inc. Ÿ 230 Ryan Way, South San Francisco, CA, 94080-6370 Ÿ Main Office: (650) 588-9200 Ÿ Outside Local Area: (800) 258-9200 Ÿ www.stevenengineering.com G2 Series/ NC G2-AB01 2500 2000 1500 1000 45.00 35.00 T = 25 deg. C I(L) = 50 mA 25.00 NC G2-AB02 NC G2-AB01 500 0 15.00 0 5 10 15 20 25 30 35 40 45 50 55 0 LED Forward Current (mA) N. Turn On Time vs. LED Forward Current 5 10 15 20 25 30 35 LED Forward Current (mA) 40 45 50 O. Turn Off Time vs. LED Forward Current For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 •(858) 715-7200 • fax (858) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU GERMANY: (49) (0)6874 182580 • fax (49)(0)6874 182585 Crydom GmbH. Page 3 of 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Dual Relays 25-40Amp • 120/240, 480 Vac • AC OUTPUT • Zero Voltage and Random Turn-On Swi tching • SCR Output • Industry Standard Package • Panel M ount MODEL NUMBERS OUTPUT SPECIFICATIONS ➀ D2425D D2425DE D2440D D2440DE Two totally independent AC output relays come in a single standard panelmount package. Utilizing an AC switch output with internal snubber, relays provide greater protection against false triggering. Model choices include zerovoltage or random turn-on (phase controllable) switching. Manufactured in Crydom's ISO 9001 Certified facility for optimum product performance and reliability. H12D4825D H12D4825DE H12D4840D H12D4840DE Operating Voltage (47-63 Hz) [Vrms] 24-280 24-280 48-530 48-530 Load Current Range ➂ [Arms] .15-25 .15-40 .15-25 .15-40 Transient Overvoltage [Vpk] 600 600 1200 1200 Max. Surge Current, (16.6ms) [Apk] 250 625 250 625 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 1.02 .63 1.02 .63 260 1620 260 1620 10 10 10 10 500 500 500 500 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle 0.5 0.5 0.5 0.5 Thermal Resistance Junction to Case (RθJC) [ûC/W] ➀ Maximum I2 t for Fusing, (8.3 msec.) [A2sec] Max. Off-State Leakage Current @ Rated Voltage [mArms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁ Max. Turn-On Time ➃ Max. Turn-Off Time Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ D24XXD H12D48XXD E-SUFFIX Control Voltage Range 4-15Vdc 4-15Vdc 15-32Vdc Max. Turn-On Voltage 4.0 Vdc 4.0 Vdc 15 Vdc Min. Turn-Off Voltage 1.0 Vdc 1.0 Vdc 1.0 Vdc 300 Ohms 240 Ohms 13mA 13mA Nominal Input Impedance Typical Input Current @ 5Vdc (@ 24Vdc for E-Suffix) 15mA © 2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ All parameters at 25˚C and per section unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 2. ➃ Turn-on time for random turn-on (-10) versions is 0.1 msec. FastFax Document No. 165 DUAL. Rev. 111203 PAGE 1 OF 2 1500 Ohms Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom's Heat Sink specification sheet for all the details. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Dual Relays 25-40Amp • 120/240, 480 Vac • AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength50/60Hz Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 10 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C M ECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Thermally Conductive Epoxy Terminals: .25' Fastons, .025' Square Pins 120/240 V MO DEL AVAILABLE OPTIONS -10 1.17 (29.7) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. Random Turn-On, Phase Controllable Example: D2440D-10 1.00 (25.4) A2 15-32Vdc Control Example: H12D4840DE B1 B2 120/24OV - 20A 120/24OV - 20A 120/24OV - 20A 2.30 (58.4) 2.30 1.87 (58.4) (47.5) CONTROL A 1.87 1.60 (47.5) (40.6) CONTROL B 4-15VDC ± H A1 A2 B2 A1 MOUNTING HOLE/SLOT .017 (4.3) DIA. 2 PLC'S .250 X .032 FASTON TERMINAL (4 PLACES) .55 (14.0) B1 120/24OV - 20A E 480V MO DEL FASTON TERMINAL .250 X .032 (4 PLACES) .15 (3.8) ± 4-15VDC CONTROL Heat Transfer Pad (Attached) Example: D2440DH - .50 (12.7) PIN .025 SQ. .100 CENTERS 4 PLACES A 1.80 (45.7) B + - .77 (19.6) .85 (21.6) 1.31 (33.2) .45 (11.4) CONTROL + .187 X .032 FASTON TERMINAL (4 PLACES) 1.37 (34.8) 1.80 .85 (21.6) 1.31 (33.2) All dimensions are in inches (millimeters) 85 25A LIMIT (1 SECTION) 2.0˚C/W 1.0˚C/W 95 5.0˚C/W 105 20 0 100 40A 80A LIMIT (2 SECTIONS) 80 60 0.5˚C/W 40A LIMIT (1 SECTION) 40 90 95 1.0˚C/W 100 2.0˚C/W 20 105 5.0˚C/W Max Allowable Base Temp. [˚C] 40 Power Dissipation [W] Power Dissipation [W] 75 0.5˚C/W Max Allowable Base Temp. [˚C] CURRENT DERATING CURVES 25A 50A LIMIT (2 SECTIONS) 0 10 20 30 40 50 10 20 Load Current [Arms] 30 40 50 60 70 Max Ambient Temp. [˚C] 80 20 40 480Vrms 120/240Vrms LOAD A A2 B1 A1 B2 LOAD B 60 80 100 10 Load Current [Arms] FastFax Document No. 165 DUAL. Rev. 111203 PAGE 2 OF 2 40 50 LOAD B 60 70 80 480Vrms 120/240Vrms A1 A2 B1 B2 480V Model W IRING DIAGRAM S APPROVALS UL E116949 CSA LR81689 (240V only) VDE 5902 UG 30 Max Ambient Temp. [˚C] LOAD A 240V Model -- B CONTROL + B CONTROL -- A CONTROL + A CONTROL 20 -- A CONTROL + A CONTROL + B CONTROL -- B CONTROL ©2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Quad Relay 20Amp • 120/240 Vac - AC OUTPUT • Zero Voltage and Random Turn-On Swi tching • Triac Output • Industry Standard Package • Panel M ount MODEL NUMBER Four independent AC output relays come in a single standard panel-mount package. Utilizing an AC switch output with internal snubber, relays provide greater protection against false triggering. Model choices include zero-voltage or random turn-on (phase controllable) switching. Manufactured in Crydom's ISO 9001 Certified facility for optimum product performance and reliability. TD2420Q TD2420QE Operating Voltage (47-63 Hz) [Vrms] 24-280 24-280 Load Current Range ➂ [Arms] OUTPUT SPECIFICATIONS ➀ .15-20 .15-20 Transient Overvoltage [Vpk] 600 600 Max. Surge Current, (16.6ms) [Apk] 250 250 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 Thermal Resistance Junction to Case (RθJC) [ûC/W] 1.2 1.2 Maximum I2 t for Fusing, (8.3 msec.) [A2sec] 260 260 10 10 200 200 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle 0.5 0.5 Control Voltage Range 4-15 Vdc 15-28 Vdc Max. Turn-On Voltage 4.0 Vdc 15 Vdc Max. Off-State Leakage Current @ Rated Voltage [mArms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁ Max. Turn-On Time ➃ Max. Turn-Off Time Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ Min. Turn-Off Voltage Nominal Input Impedance Typical Input Current 1.0 Vdc 1.0 Vdc 330 Ohms 1500 Ohms 12 mA @ 5Vdc 15 mA @ 24Vdc ©2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ All parameters at 25˚C and per section unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, max. 20A per section, max. 60A per package. ➃ Turn-on time for random turn-on versions is 0.1 msec. FastFax Document No. 166 QUAD Rev. 111403 PAGE 1 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Quad Relay 20Amp • 120/240 Vac - AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base 2500 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 10 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C M ECHANICAL SPECIFICATIONS Weight: (typical) 3.5 oz. (109g) Encapsulation: Thermally Conductive Epoxy Terminals: .25Ó Faston, .025 Square Pins MOUNTING HOLE/SLOT .017 (4.3) DIA. .025 SQ. PINS 2 PLC'S ON .100 CENTERS .250 X .032 FASTON TERMINAL (8 PLACES) AVAILABLE OPTIONS -10 H E 1.126 (28.6) Random Turn-On, Phase Controllable Example: TD2420Q-10 -DC SECTION A 2.30 (58.4) Heat Transfer Pad (Attached) Example: TD2420QH C1 A1 A2 120/24OV - 20A -DC SECTION B -DC SECTION B1 15-28Vdc Control Example: TD2420QE B2 C +DC COMMON -DC SECTION 120/24OV - 20A C2 120/24OV - 20A D 1.87 1.60 (47.5) (40.6) All dimensions are in inches (millimeters) 120/24OV - 20A D1 D2 .77 (19.6) .375 (9.5) .85 (21.6) 1.37 (34.8) 1.80 (45.7) CURRENT DERATING CURVES W IRING DIAGRAM Power Dissipation [W] 0.25¼C/W 75 80 0.5¼C/W 90 1.0¼C/W 40 2.0¼C/W 105 5.0¼C/W 0 15 30 45 Total Load Current [Arms] 60 20 40 60 80 Max Ambient Temp. [˚C] Max Allowable Base Temp. [¼C] 100 120/240Vrms 120/240Vrms LOAD B LOAD D B1 A1 B2 A2 D1 C1 D2 C2 LOAD A LOAD C 120/240Vrms 120/240Vrms -- DC SECTION C -- DC SECTION A + DC COMMON -- DC SECTION B -- DC SECTION D Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom's Heat Sink specification sheet for all the details. APPROVALS UL E116949 CSA LR81689 FastFax Document No. 166 QUAD Rev. 111403 PAGE 2 OF 2 ©2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series 53TP 25-50Amp • 240/480 Vac - 3 PHASE • SCR Output • LED Status Indicator • Protective Cover Available (Part No. KS300) • Panel M ount • Integrated Overvoltage Protection by Automatic Self Turn-On (Suff ix P) MODEL NUMBERS Three-phase solid state relays switch up to 530 Vrms directly to loads such as motors, transformers, heating elements, etc. Available with either AC or DC input (coil) control in zero-voltage or random turn-on switching versions. Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. D53TP25D D53TP50D A53TP25D A53TP50D Operating Voltage (47-63 Hz) [Vrms] 48-530 48-530 48-530 48-530 Load Current Range➂ [Arms] .05-25 .05-50 .05-25 .05-50 Transient Overvoltage [Vpk] 1200 1200 1200 1200 Max. Surge Current, (16.6ms) [Apk] 250 625 250 625 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 Thermal Resistance Junction to Case (RθJC) [˚C/W] 1.02 .63 1.02 .63 Maximum I2 t for Fusing, (8.3 msec.) [A2sec] 260 1620 260 1620 10 10 10 10 500 500 500 500 1/2 Cycle 1/2 Cycle 10.0 msec 10.0 msec 1/2 Cycle 1/2 Cycle 40.0 msec 40.0 msec 0.5 0.5 0.5 0.5 OUTPUT SPECIFICATIONS ➀ Max. Off-State Leakage Current @ Rated Voltage [mArms] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁ Max. Turn-On Time ➃ Max. Turn-Off Time Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ DC CONTROL AC CONTROL Control Voltage Range 3-32 Vdc 90-280 Vrms (60Hz) Max. Turn-On Voltage 3.0 Vdc 90 Vrms Min. Turn-Off Voltage 1.0 Vdc 10 Vrms 450 Ohms 54.8k Ohms Nominal Input Impedance 10mA @ 5 Vdc Typical Input Current 2.2mA @ 120 Vrms, 4.4mA @ 240 Vrms ©2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ All parameters at 25ºC and per section unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 2. ➃ Turn-on time for random turn-on versions is 0.02 msec (DC Control Models). FastFax Document No.161 SERIES53TP. Rev. 111003 PAGE 1 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series 53TP 25-50Amp • 240/480 Vac - 3 PHASE GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 8 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80ºC Ambient Storage Temperature Range -40 to 125ºC M ECHANICAL SPECIFICATIONS Weight: (typical) 10.3 oz. (315g) Encapsulation: Thermally Conductive Epoxy Terminals: -10 DP Non-Zero Cross, Instantaneous Turn-On Example: D53TP50D-10 A1 B1 H C1 1.875 2 Controlled, 1 Linked (A1-A2) 2.125 (47.6) Example: D53DP50D (54.0) Internal Overvoltage Protection. Relay Will Self Trigger Between 900-1200 Vpk. Not Suitable For Capacitive Loads. Example: D53TP50DP B2 .39 REF (10.0) Heat Trasfer Pad (Attached) Example: D53TP50DH 1.18 (30.0) Crydom Heat Sinks offer excellent thermal management and are per fectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. 2.89 (73.4) + INPUT STATUS LED A2 P 0.21 (5.3) 4.09 (103.8) 10-32 TERMINAL (6 PLACES ) 0.79 (20.1) INPUT AVAILABLE OPTIONS Screws and Saddle Clamps Furnished -- C2 .78 (19.8) 1.36 (34.5) 1.56 (39.6) 3.62 (91.9) 6-32 TERMINAL (2 PLACES ) .79 (20.1) .94 (24.0) .125 (3.2) BASE PLATE THICKNESS Screw Torque Requirements : 6-32 Screws - 10 in. lbs., 8-32 and 10-32 Screws - 20in. lbs. (Screws dry without grease.) All dimensions are in inches (millimeters) CURRENT DERATING CURVES A53TP25D, D53TP25D A53DP25D, D53DP25D .5ºC/W 80 40 105 110 20 115 Power Dissipation 100 100 1.5ºC/W Base Plate Temp [ºC] 0.5ºC/W 60 105 1ºC/W 40 110 1.5ºC/W 115 20 120 120 0 0 5 10 15 20 25 Load Current [Arms] 20 40 60 5 80 10 15 60 80 95 90 0.5ºC/W 100 1ºC/W 60 105 1.5ºC/W 110 30 115 10 20 30 40 Load Current [Arms] 50 20 40 60 90 80 Max Ambient Temp. [ºC] .25ºC/W 150 Base Plate Temp [ºC] Power Dissipation Power Dissipation 40 180 120 FastFax Document No.161 SERIES53TP Rev. 111003 PAGE 2 OF 2 20 Max Ambient Temp. [ºC] 90 0.25ºC/W APPROVALS UL E116950 CSA LR81689 VDE 5941 UG 25 A53TP50D, D53TP50D A53DP50D, D53DP50D 120 0 20 Load Current [Arms] Max Ambient Temp. [ºC] 95 .5ºC/W 100 120 105 90 60 1ºC/W 110 1.5ºC/W 115 30 0 Base Plate Temp [ºC] Power Dissipation 1ºC/W Base Plate Temp [ºC] 60 120 10 20 30 40 Load Current [Arms] 50 20 40 60 80 Max Ambient Temp. [ºC] ©2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com SSeries SSC olid State DC Contactor 25Amp • 0-1000 Vdc - DC OUTPUT • • • • IGBT Output Panel Mount High Voltage Internal Overvoltage Protection Available • Control Voltage 12Vdc, 24Vdc, 36Vdc Series SSC solid state DC contactors feature IGBT technology for high voltage DC switching applications All models come in Crydom's standard panel-mount package. Manufactured in Crydom's ISO 9001 Certified facility for optium product performance and reliability. OUTPUT SPECIFICATIONS ➀ MODEL NUMBERS SSC800-25 SSC1000-25 0-1000 0-800 Operating Voltage Range [Vdc] 900 ➃ 1200 ➄ 25 25 Min. Load Current [mA] 20 20 Max. Surge Current, [Adc] (10msec) 75 75 Max. On-State Voltage Drop @ Rated Current [Vdc] 1.6 1.6 Thermal Resistance Junction to Case [R θJC] C/W 0.8 0.8 Max. Off-State Leakage Current @ Rated Voltage [mA] 0.3 0.3 Max. Turn-On Time [msec] 1.5 1.5 Max. Turn-Off Time [msec] 1.5 1.5 Maximun Transient Voltage [Vpk] Max. Load Current ➂ [Adc] INPUT SPECIFICATIONS ➀ Nominal Control Voltage [Vdc] ➅ 12 24 36 8-16 20-28 32-40 Maximum Turn-On Voltage [Vdc] 8 20 32 Minimum Turn-Off Voltage [Vdc] 1 1 1 Nominal Input Impedance [Ohm] 780 1500 2,400 15 15 Control Voltage Range [Vdc] Typical Input Current at Nominal Voltage [mA] GENERAL NOTES 15 © 2003 CRYDOM CORP, Specifications subject to change without notice. ➀ All parameters at 25ºC unless otherwise specified. ➁ Dielectric strength and insulation resistance are measured between input and output. ➂ Heat sinking required, for derating curves see page 2. ➃ Internal overvoltage protection included. ➄ Internal overvoltage protection not included. ➅ Use suffix -12, -24 or -36 to specify control voltage. For other values call factory Sample: SSC800-25-24. SERIES SSC. Rev. 111703 PAGE 1 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com SSeries SSC olid State DC Contactor 25Amp • 0-1000 Vdc - DC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength 60Hz 2500 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 50 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -30 to 80ºC Ambient Storage Temperature Range -40 to 125ºC MECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (86.5g) Encapsulation: Thermally Conductive Epoxy Terminals: Screws and Saddle Clamps Furnished, Unmounted MECHANICAL SPECIFICATIONS MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1.10 (27.9) .45 (11.4) WIRING CONNECTIONS Input and output polarity must be observed. Inductive loads must be diode suppressed. 8-32 TERMINAL (2 PLACES ) 4 (–) 1 (–) 2 1.87 (47.5) -4 + INPUT DC CONTROL SOURCE 2.30 (58.4) 1.70 (43.2) 3 SSR OUTPUT OUTPUT INPUT LOAD 1 3 (+) 2 (+) (–) (+) Transient Protection BASE PLATE .125 (3.2) 1.00 (25.4) 1.80 (45.7) .78 (19.8) .90 (22.9) 6-32 TERMINAL (2 PLACES) All loads are inductive, even ones that are not so labeled. An inductive load will produce harmful transient voltages when it is turned off. The more perfect the switch, the larger the transient voltages; the IGBT output is so nearly an ideal switch that the transient voltages produced by seemingly "non-inductive" loads can cause damage if not suppressed. Diodes should be fast recovery type with PIV rated greater than supply voltage. Screw Torque Requirements: 6-32 Screws - 10 in. lbs., 8-32 - 20in. lbs. (Screws dry without grease.) CURENT DERATING CURVE 2˚C/W 30 1˚C/W 3˚C/W 20 100 105 110 115 10 NO HEATSINK 120 Base Plate Temp [˚C] Power Dissipation 25A 40 0 5 10 15 20 Load Current [Arms] 25 10 20 30 40 50 60 70 80 Max Ambient Temp. [˚C] ©2003 CRYDOM CORP, Specifications subject to change without notice. SERIES SSC. Rev. 111703 PAGE 2 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series SST SOFT-START Modules • 10-90Amp • AC OUTPUT • 120 & 240 Vac Models tory about use with 480 Vac loads. For a complete set (control module and solid state relay) order 10SST120, 25SST120, etc. Manufactured in Crydom's ISO 9002 Certified facility for optimum product performance and reliability. Models SST120 and SST240 auxiliary function modules gradually apply power to the load when energized by the control voltage. They must be used with Crydom Series 1 (-10) random turn-on solid state relays. Consult fac- MODEL NUMBERS 120 Vac 10SST120 25SST120 40SST120 240 Vac 10SST240 25SST240 50SST240 75SST240 90SST240 RELAY OUTPUT SPECIFICATIONS ➀ 90-140 (120 Vac Models) 180-280 (240 Vac Models) Operating Voltage Range (47-63 Hz) [Vrms] Load Current Range ➂ [Arms] .04-10 .04-25 .04-50 .04-75 .04-90 400 (120 Vac models) 600 (240 Vac models) Transient Overvoltage [Vpk] 120 Max. Surge Current, (16.6ms) [Apk] 250 625 1000 1200 1.6 1.6 1.6 1.6 1.6 Thermal Resistance Junction to Case (RθJC) [¡C/W] Maximum I2 t for Fusing, (8.3 msec.) [A2sec] 1.48 1.02 .63 .31 .28 60 260 1620 4150 6000 Max. Off-State Leakage Current @ Rated Voltage [mArms] 10.0 10.0 10.0 10.0 10.0 Max. On-State Voltage Drop @ Rated Current [Vpk] Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁ Max. Turn-Off Time Power Factor (Min.) with Max. Load 500 500 500 500 500 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle 1/2 cycle 0.5 0.5 0.5 0.5 0.5 CONTROL M ODULE INPUT SPECIFICATIONS ( Terminal 3B ) ➀ DC CONTROL Control Voltage Range 3.5-10Vdc Max. Turn-On Voltage 3.5 Vdc Min. Turn-Off Voltage 1.0 Vdc Typical Input Current 1.6mA @ 5Vdc Nominal Turn-On Delay Time @ 60Hz 150 msec Nominal Swell (Ramp) Time @ 60Hz 180 msec Max. Reset Time 100 µsec CONTROL M ODULE OUTPUT SPECIFICATIONS (Terminal 4B-Input to relay)➀ Max. Off-State Operating Voltage Max. Load Current (Sink) Max. On-State Voltage @ 3mA Max. Off-State Leakage @ 10Vdc GENERAL NOTES DC CONTROL 36 Vdc 3.0 mAdc 0.5 Vdc 1.0 µAdc ©2003 CRYDOM CORP, Specifications subject to change without notice. ➀ All parameters at 25˚C unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required (Relay Only), see Series 1 data sheet. FastFax Document No. 202 SERIES SST Rev. 111703 PAGE 1 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series SST SOFT-START Modules • 10-90Amp • AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength, Signal to Load 4000 Vrms Dielectric Strength, Signal to Base 4000 Vrms Ambient Operating Temperature Range -30 to 80˚C Ambient Storage Temperature Range -40 to 125˚C M ECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (43g) Encapsulation: Thermally Conductive Epoxy AVAILABLE OPTIONS SST120 Control Module Only (120 Vac line) SST240 Control Module Only (240 Vac line) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1.10 (27.9) .50 (12.7) .270 (2) (6.9) FASTON TERMINAL .250 X .032 4 PLCS. DERATING CURVES Ð See Series 1 W IRING DIAGRAM 2.30 (58.4) 1.70 (43.2) 1.87 (47.5) OUTPUT 1A 1B 2B 2A SOFT-START -- MODULE3B+3A 4A 4B 1.00 (25.4) 1.80 (45.7) .270 FASTON (6.9) TERMINAL .187 X .032 4 PLCS. .78 (19.8) .87 (22.2) INPUT Control Voltage (+) All dimensions are in inches (millimeters) Gnd (Ð) Line Load OUTPUT 1 2 Ð10 RELAY 4 -- 3 INPUT + Notes 1. Following pins may be interchanged: 1A & 1B, 2A & 2B, 3A & 3B. 2. Pin 4A & 4B may not be interchanged. 3. The line and load may be interchanged. ©2003 CRYDOM CORP, Specifications subject to change without notice. APPROVALS UL E116949 FastFax Document No. 202 SERIES SST Rev. 111703 PAGE 2 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series NTD/NTA 10-25Amp • 120/240 Vac • AC OUTPUT • Panel Mount • Zero Voltage or Random Turn-On Switching • Wide Control Voltage Range • DC Control, AC Control The Series NTD is available featuring zero-voltage or random switching and a broadened operating range (24280Vac). This wide range permits optimum performance at both 120Vac and 240Vac line voltages. Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability. AC Control (NTA) ➅ DC Control (NTD) OUTPUT SPECIFICATIONS ➀ NTD2405 NTD2410 NTD2425 NTA2410 NTA2425 24-280 24-280 24-280 24-280 24-280 0.15-5 0.15-10 0.15-25 0.15-10 0.15-25 600 600 600 600 600 Max. Surge Current, (16.6ms) [Apk] 40 120 250 120 250 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 1.6 Thermal Resistance Junction to Case (R θJC) [˚C/W] 4.5 1.48 1.02 1.48 1.02 Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec] 7.0 60 260 60 260 Max. Off-State Leakage Current @ Rated Voltage [mA] .01 10 10 10 10 200 200 200 200 200 1/2 Cycle 1/2 Cycle 1/2 Cycle 10 ms 10 ms 1/2 Cycle 1/2 Cycle 1/2 Cycle 40 ms 40 ms 0.5 0.5 0.5 0.5 0.5 Control Voltage Range 4-15 Vdc 3-32 Vdc 3-32 Vdc Max. Turn-On Voltage 4.0 Vdc 3.0 Vdc 3.0 Vdc 90 Vrms 90 Vrms Min. Turn-Off Voltage 1.0 Vdc 1.0 Vdc 1.0 Vdc 10 Vrms 10 Vrms Nominal Input Impedance 300 ohms See note ⑤ See note ⑤ 10.6 kOhm 10.6 kOhm Typical Input Current @ 5 Vdc (@ 120 Vrms for NTA) 13 mAdc 10 mAdc 10 mAdc 10 mArms 10 mArms Operating Voltage (47-63 Hz) [Vrms] ➂ [Arms] Load Current Range Transient Overvoltage [Vpk] Min. Off-State dv/dt @ Max. Rated Voltage [V/ µsec] ➁ Max. Turn-On Time ➃ Max. Turn-Off Time Power Factor (Min.) with Max. Load INPUT SPECIFICATIONS ➀ © 2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ ➁ ➂ ➃ ⑤ ➅ 90-140 Vrms 90-140 Vrms All parameters at 25˚C unless otherwise specified. Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 Heat sinking required, for derating curves see page 2. Turn-On time for random turn-on versions is 0.02 msec. (DC control models) Input circuitry incorporates active current limiter. 24 Vac Control Version Available (use suffix E) FastFax Document No. 176 SERIES NTD/NTA Rev. 111303 PAGE 1 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series NTD/NTA 10-25Amp • 120/240 Vac • AC OUTPUT GENERAL SPECIFICATIONS Dielectric Strength 50/60Hz, Input/Output/Base 3750 Vrms 109 Ohm Insulation Resistance (Min.) @ 500 Vdc 10 pF Max. Capacitance Input/Output Ambient Operating Temperature Range -40 to 80˚C Ambient Storage Temperature Range -40 to 125˚C MECHANICAL SPECIFICATIONS Weight: (typical) Encapsulation: Thermally Conductive Epoxy Terminals: MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1 1.10 (27.9) .45 (11.4) 8-32 TERMINAL (2 PLACES ) OUTPUT 2 1.87 (47.5) -- + 4 2.30 (58.4) 1.70 (43.2) 1.10 (27.9) .45 (11.4) FASTON TERMINAL .250 X .032 (4 PLCS.) .87 REF. (22.2) OUTPUT 1 -- 6-32 TERMINAL (2 PLACES) .78 (19.8) .90 (22.9) All dimensions are in inches (millimeters) 2.30 (58.4) 2 1.87 (47.5) Screw Torque Requirements: 6-32 Screws - 10 in./lbs., 8-32 and 10-32 Screws - 20in./lbs. (Screws dry without grease.) 1.70 (43.2) + 4 1.00 (25.4) 1.80 (45.7) BASE PLATE .125 (3.2) Screws and Saddle Clamps Furnished, Unmounted MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 3 INPUT 3.0 oz. (86.5g) 3 INPUT Terminal Hardware Furnished: 4 Screws and 4 Saddle Clamps .78 (19.8) 1.25 (31.8) 1.00 (25.4) 1.80 (45.7) Crydom Heat Sinks offer excellent thermal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details. AVAILABLE OPTIONS -10 Random Turn-On Phase Controllable Example: NTD2425-10 F Faston Terminals .250 x .032 Faston Terminals (Shown above) Example: NTD2425F E 24 Vac Control Example: NTA2425E CURRENT DERATING CURVES 10A 30 120 110 5˚C/W 8 NO HEATSINK 115 4 120 25 Power Dissipation 2 1˚C/W Base Plate Temp [˚C] 115 3 9˚C/W Power Dissipation NO HEATSINK Base Plate Temp [˚C] 110 5˚C/W 4 95 3˚C/W 7˚C/W 10˚C/W 5 Power Dissipation 25A 12 6 100 3˚C/W 2˚C/W 20 15 110 10 NO HEATSINK 5 1 0 1 2 3 4 5 Load Current [Arms] APPROVALS UL E116950 CSA PENDING TUV PENDING FastFax Document No. 176 SERIES NTD/NTA Rev. 111303 PAGE 2 OF 2 10 20 40 60 80 Max Ambient Temp. [˚C] 120 0 2 4 6 8 Load Current [Arms] 10 20 40 60 80 Max Ambient Temp. [˚C] 5 10 15 20 Load Current [Arms] 25 20 40 60 80 Max Ambient Temp. [˚C] © 2003 CRYDOM CORP, Specifications subject to change without notice. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Base Plate Temp [˚C] 5A Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series CPV Phase Control Modules • 120 & 240 Vac Models • 0-5 Vdc Phase Control Models CPV120 and CPV240 auxiliary function modules provide control of the phased turn-on of a solid state relay, in response to the application of a 0-5 Vdc control signal. They must be used with MODEL NUMBERS Crydom Series 1 (-10) random turn-onsolid state relays. Consult factory about use with 480 Vac loads. For a com plete set (control module and solid state relay) order 10CPV120, 25CPV120, etc. Manufactured in Crydom's ISO 9001 Certified facility for optimum product performance and reliability. 120 Vac 10CPV120 25CPV120 40CPV120 240 Vac 10CPV240 25CPV240 50CPV240 75CPV240 90CPV240 RELAY OUTPUT SPECIFICATIONS ➀ 90-140 (120 Vac Models) 180-280 (240 Vac Models) Operating Voltage Range (47-63 Hz) [Vrms] Load Current Range ➂ [Arms] .04-10 .04-25 .04-50 .04-75 .04-90 400 (120 Vac models) 600 (240 Vac models) Transient Overvoltage [Vpk] Max. Surge Current, (16.6ms) [Apk] 120 250 625 1000 1200 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 1.6 1.48 1.02 0.63 0.31 0.28 60 260 1620 4150 6000 Max. Off-State Leakage Current @ Rated Voltage [mArms] 10.0 10.0 10.0 10.0 10.0 Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁ 500 500 500 500 500 Thermal Resistance Junction to Case [RθJC] ¡C/W Maximum I2 t for Fusing, (8.3 msec.) [A2sec] 0.02 Max. Turn-On Time [msec] 1/ 2 Max. Turn-Off Time 0.02 cycle 0.5 Power Factor (Min.) with Max. Load 1/ 2 0.02 1/ 2 cycle 0.5 CONTROL M ODULE INPUT SPECIFICATIONS ➀ cycle 0.5 0.02 1/ 2 cycle 0.5 0.02 1/ 2 cycle 0.5 DC CONTROL 3.5-10Vdc Logic Supply Range (Terminal 3A) 1.6mA @ 5Vdc Typical Supply Current 0-5 Vdc Control Voltage Range (Terminal 3B) 1500 Ohms Nominal Control Input Impedance 1.0 Min. Turn-Off Voltage CONTROL M ODULE OUTPUT (T erminal 4B Ð I nput t o R elay ) ➀ Max. Off-State Operating Voltage 36 Vdc Max. Load Current (Sink) 3.0 mA Max. On-State Voltage @ 3mA 0.5 Vdc Max. Off-State Leakage @ 10Vdc GENERAL NOTES 1.0 µAdc © 2003 CRYDOM CORP, Specifications subject to change without notice. ➀ All parameters at 25¼C unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required (Relay Only), see Series 1 data sheet. FastFax Document No. 203 SERIES CPV Rev. 111103 PAGE 1 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Series CPV Phase Control Modules GENERAL SPECIFICATIONS Dielectric Strength, Signal to Load 4000 Vrms Dielectric Strength, Signal to Base 4000 Vrms Ambient Operating Temperature Range -30 to 80¼C Ambient Storage Temperature Range -40 to 125¼C M ECHANICAL SPECIFICATIONS Weight: (typical) 3.0 oz. (43g) Encapsulation: AVAILABLE OPTIONS CPV120 Control Module Only (120 Vac line) CPV2 40 Control Module Only (120 Vac line) Thermally Conductive Epoxy MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 1.10 (27.9) .50 (12.7) .270 (2) (6.9) FASTON TERMINAL .250 X .032 4 PLCS. DERATING CURVES Ð See Series 1 2.30 (58.4) 1.70 (43.2) 1.87 (47.5) Positive Supply (+) (5Vdc) 1A 1B 2B 2A -4A 4B + 3B 3A 1.00 (25.4) 1.80 (45.7) Control Voltage (+) (0 to 5Vdc) Common (Ð) .270 FASTON (6.9) TERMINAL .187 X .032 4 PLCS. .78 (19.8) .87 (22.2) All dimensions are in inches (millimeters) Line Load OUTPUT 1 2 Ð10 RELAY 4 3 INPUT Notes 1. Following pins may be interchanged: 1A & 1B, 2A & 2B. 2. Pin 4A & 4B may not be interchanged, nor may pins 3A & 3B. 3. The line and load may be interchanged. © 2003 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No. 203 SERIES CPV Rev. 111103 PAGE 2 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series LPCV Linear Proportional Load Controller The LPCV Linear Proportional Controllers control loads up 110 Amps. Changes in the input signal linearly vary the firing angle of the thyristor load control device. Control circuitry and power switch are in the same package. The PS-120 (120V) and PS-240 (240V) power supplies are designed for use with the LPCV controller to provide the 20Vac required in addition to the control voltage. • Precise Proportional Load Control • Optically Isolated • 0-5 Vdc, 0-10 Vdc, 4-20mA Input Control Models • Control Circuit Requires no Adjustment or Calibration 0-5 Vdc CONTROL 0-10 Vdc CONTROL 4-20 mA CONTROL 5LPCV2415 10LPCV2415 20LPCV2415 5LPCV2425 10LPCV2425 20LPCV2425 Operating Voltage (60 Hz) [Vrms] 20-300 20-300 Load Current Range .10-15 MODE L NUMBERS 5LPCV2440 5LPCV2475 5LPCV24110 10LPCV2440 10LPCV2475 10LPCV24110 20LPCV2440 20LPCV2475 20LPCV24110 OUTPUT SPECIFICATIONS [Arms] 20-300 20-300 20-300 .10-40 .15-75 .20-110 .10-25 Transient Overvoltage [Vpk] 600 600 600 600 600 Max. Surge Current, (16.6ms) [Apk] 150 250 625 1000 1500 10 15 20 30 50 1.48 1.02 0.63 0.31 0.28 94 260 1620 4150 9340 Maximum Voltage Drop (100% On) [Vpk] 1.6 1.6 1.6 1.6 1.6 Minmum Off-State dv/dt [V/µsec] 200 200 200 200 200 Power Factor (Min.) with Max. Load 0.5 0.5 0.5 0.5 0.5 Max. Off-State Leakage Current @ Rated Voltage [mArms] Thermal Resistance Junction to Case (R JC) [ûC/W] Maximum I2 t for Fusing, (8.3 msec.) [A2sec] INPUT SPECIFICATIONS Control Range (Nominal) Control Range Limits (Min/Msx) Turn-On Threshold 0-5 Vdc 0-10 Vdc 4-20 mA -0.5/10 Vdc -1.0/20 Vdc -0.5/25 mA .25 Vdc 0.5 Vdc 4.5 mA 25K Ohms 460 Ohms 12.7K Ohms Min. Input Impedance © 2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ All parameters at 25˚ûC unless otherwise specified. ② Linear taper potentiometer 1-10K Ohm, 1/2 Watt. ➂ 50Hz models available. (20 mA) 10V ➃ 20Vac must be in phase with load. TYPICAL APPLICATIONS Firing Angle vs. Input Signal 5V 7.5V 5V 2.5V 2.5V (4 mA) 0V 180 FastFax Document No. 207 SERIES LPCV. Rev. 111303 PAGE 1 OF 3 0V 135 90 45 0 • • • • • • • • • Infrared and Quartz Heaters Resistive Heating Elements Transformers Rectified DC Motors Thermal Forming Equipment Blow Molding Equipment Industrial Temperature Controllers Conveyor Speed Control Printing Applications For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series LPCV Linear Proportional Load Controller GENERAL SPECIFICATIONS Dielectric Strength, Signal to Load 2500 Vrms Dielectric Strength, Signal to Base 2500 Vrms Ambient Operating Temperature Range -30 to 80˚C Ambient Storage Temperature Range -40 to 125˚C M ECHANICAL SPECIFICATIONS Weight: (typical) MOUNTING SLOT 0.17 (4.3) DIA. .62 (15.7) ~ 5 4 3 12Vdc Output For Manual Control + FastFax Document No. 207 SERIES LPCV. Rev. 111303 PAGE 2 OF 3 .30 Typ. (7.6) 1.60 Max. (40.6) .12 (3.0) 5 4 3 ➁ Note: Not Used if Connected to Analog Card .12 (3.0) OUTPUT 2.50 (63.5) 1.00 (25.4) INPUT 2.62 (66.5) 2.21 (56.1) 2.10 (53.3) 1.00 (25.4) 2.25 (57.2) 6-32 TERMINALS (2 PLACES) .250 FASTON TERMINALS (2 PLACES) PS120/ PS240 PS120 120 Vac PS240 240 Vac 20 Vac/100mA 20 Vac/100mA Ambient Operating Temperature Range -30 to 80˚C Ambient Storage Temperature Range -40 to 125˚C M ECHANICAL SPECIFICATIONS Weight: (typical) 2 From Control 0-5 Vdc 0-10 Vdc 4-20 mA 2.00 (50.8) Output Voltage 50/60Hz PROPORTIONAL CONTROLLER -- 1.35 Max. (40.6) 1.05 (26.7) POW ER SUPPLY SPECIFICATIONS ➃ Input Voltage 50/60Hz W IRING DIAGRAM 20 Vac from Power Supply Module ➃ PS-120 (120Vac) PS-240 (240Vac) See note ➃ 8-32 Screws, .25 Inch Fastons PROPORTIONAL CONTROLLER .250 FASTON TERMINALS (5 PLACES) 7 6 Terminals: OUTPUT 8-32 TERMINALS (2 PLACES) 1 Thermally Conductive Epoxy 1.52 (38.6) Screw Torque Requirements : 6-32 Screws - 10 in./lbs., 8-32 and 10-32 Screws - 20in./lbs. (Screws dry without grease.) OUTPUT Encapsulation: 2.21 (56.1) All dimensions are in inches (millimeters) 6.0 oz. (175g) 8.6 oz. (245g) Encapsulation: Thermally Conductive Epoxy Terminals: 6-32 Screws, .25 Inch Fastons ©2003 CRYDOM CORP, Specifications subject to change without notice. NOTE: UNSUITABLE APPLICATIONS The LPCV is not suitable for some load control applications including, but not limited to the following: • AC Motor Control • Three Phase Motors • Tranformers requiring pure sine wave input • Applications which cannot withstand thyristor noise • Zero Crossing Applications Please contact Crydom's application engineering department for additional information and specific application questions. For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series LPCV Linear Proportional Load Controller CURRENT DERATING CURVES 15A 25A 15 30 116 NO HEATSINK 120 100 3˚C/W 2˚C/W 20 15 110 10 NO HEATSINK 5 Base Plate Temp [˚C] 5 6˚C/W 25 Power Dissipation 4˚C/W 10 95 1˚C/W 112 Base Plate Temp [˚C] Power Dissipation 2˚C/W 120 124 0 0 3 6 9 12 15 Load Current [Arms] 40A 40 60 80 5 100 80 1˚C/W 110 40 Power Dissipation .3˚C/W Base Plate Temp [˚C] .5˚C/W Load Current [Arms] 60 60 80 80 20 Max Ambient Temp. [˚C] 40 60 80 0 Load Current [Arms] 20 40 60 90 .4˚C/W .2˚C/W .5˚C/W 120 100 80 1˚C/W 110 40 120 0 40 40 120 120 NO HEATSINK 0 20 20 Max Ambient Temp. [˚C] 160 95 Power Dissipation 110 20 Base Plate Temp [˚C] 100 2˚C/W 40 25 90 40 30 20 Base Plate Temp [˚C] 1˚C/W .5˚C/W 20 15 110A 120 1.5˚C/W 10 10 Load Current [Arms] 75A 60 Power Dissipation 20 Max Ambient Temp. [˚C] 0 80 30 Max Ambient Temp. [˚C] 60 90 120 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] PERCENTAGE ON vs. INPUT VOLTAGE 0-10 Vdc Control 100 100 80 80 60 60 Percentage ON Percentage ON 0-5 Vdc Control 40 50 Hz 60 Hz 20 40 50 Hz 60 Hz 20 0 0 1 2 3 4 5 1 Input Voltage 2 3 4 5 6 7 8 9 10 Input Voltage 4-20 mA Control 100 Percentage ON 80 60 40 50 Hz 60 Hz 20 0 2 4 6 8 10 12 14 16 18 20 22 Input Voltage ©2003 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No. 207 SERIES LPCV. Rev. 111303 PAGE 3 OF 3 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series PCV Analog Input Power Controller • • • • The PCV Series proportional controllers are self contained power control modules integrating a complete phase fired logic control system and a solid state relay in the same standard package. Typical applications include heaters, vibratory feeders and tungsten lamps. Operates at 60Hz & 50Hz Internal Snubber Industry Standard Package Control Circuit Requires No Adjustment or Calibration MODEL NUMBERS 7PCV2415 7PCV2425 10PCV2415 10PCV2425 10PCV2450 10PCV2475 10PCV2490 OUTPUT SPECIFICATIONS➀ 100-240 100-240 100-240 100-240 100-240 .15-15 .15-25 .15-50 .15-75 .15-90 Transient Overvoltage [Vpk] 600 600 600 600 600 Max. Surge Current, (1 Cycle) [Apk] 150 250 625 1000 1200 Max. Off-State Leakage Current @ Rated Voltage [mA] 10 15 20 20 20 Maximum I 2 t for Fusing (8.3 msec) [A 2sec] 94 260 1620 4150 6000 Maximum Voltage Drop (100% On) [Vpk] 1.6 1.6 1.6 1.6 1.6 Minimum Off-State dv/dt [V/µsec] 200 200 200 200 200 Power Factor (Min.) with Max. Load 0.5 0.5 0.5 0.5 0.5 Operating Voltage (47-63 Hz) [Vrms] Max. Load Current Range [Arms] INPUT SPECIFICATIONS ➀ 7PCV24xx 10PCV24xx 2-7 Vdc 2-10 Vdc 4 mA 4 mA Control Voltage Range Typical Input Current @ 5 Vdc GENERAL NOTES © 2003 CRYDOM CORP, Specifications subject to change without notice. All parameters at 25º C unless otherwise specified. TYPICAL APPLICATIONS • Industrial Temperature Controllers • Light Dimming • Vibratory Feeders • Resistive Heating Elements • Conveyor Speed Control UNSUITABLE APPLICATIONS The PCV is not suitable for some load applications including, but not limited to the following: • • • • Percentage On vs. Input Voltage 100 80 Percentage ON ➀ 60 40 50 Hz AC Motor Control Three Phase Motors Transformers requiring pure sine wave input Zero Crossing Applications Please contact Crydom’s application engineering department for additional information and specific application questions. FastFax Document No. 204 SERIES PCV. Rev. 111403 85PAGE 1 OF 2 60 Hz 20 0 2.5 3.5 4.5 5.5 6.5 7.5 Input Voltage For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 8.5 9.5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Series PCV Analog Input Power Controller GENERAL SPECIFICATIONS Dielectric Strength, Signal to Load 2500 Vrms Dielectric Strength, Signal to Base 2500 Vrms Ambient Operating Temperature Range -30 to 80˚C Ambient Storage Temperature Range -40 to 125˚C M ECHANICAL SPECIFICATIONS Weight: (typical) 3.5 oz. (100g) Encapsulation: Thermally Conductive Epoxy Screws and Saddle Clamps Furnished, Unmounted Terminals: W IRING DIAGRAM 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. ~ OUTPUT 1 -4 + 4 All dimensions are in inches (millimeters) Screw Torque Requirements: 6-32 Screws - 10 in. lbs., 8-32 and 10-32 Screws - 20in. lbs. (Screws dry without grease.) 2.30 (58.4) 1.70 (43.2) 2 1.87 (47.5) 1 OUTPUT 2 PROPORTIONAL CONTROLLER 8-32 TERMINAL (2 PLACES ) 3 INPUT 3 INPUT 1.00 (25.4) 1.80 (45.7) -- + 6-32 TERMINAL (2 PLACES) .78 (19.8) .90 (22.9) 25A 15A 30 15 2˚C/W 116 6˚C/W NO HEATSINK 5 120 25 Power Dissipation 4˚C/W 10 Base Plate Temp [˚C] Power Dissipation CURRENT DERATING CURVES 95 1˚C/W 112 100 3˚C/W 2˚C/W 20 15 110 10 NO HEATSINK 5 Base Plate Temp [˚C] BASE PLATE .125 (3.2) 120 124 0 0 6 9 12 15 Load Current [Arms] 50A 40 60 5 80 .5˚C/W 95 .3˚C/W .5˚C/W 100 60 1˚C/W 110 30 0 50 20 40 60 80 Max Ambient Temp. [˚C] 40 60 80 90 .2˚C/W .4˚C/W 80 100 1˚C/W 110 40 120 120 120 NO HEATSINK 0 Power Dissipation 110 20 40 20 Max Ambient Temp. [˚C] 120 Base Plate Temp [˚C] 100 2˚C/W 30 25 .5˚C/W Power Dissipation 1.5˚C/W 40 20 20 90 Base Plate Temp [˚C] 1˚C/W Load Current [Arms] 15 90A 90 10 10 Load Current [Arms] 75A 60 Power Dissipation 20 Max Ambient Temp. [˚C] Base Plate Temp [˚C] 3 0 15 30 45 60 Load Current [Arms] 75 20 40 60 80 Max Ambient Temp. [˚C] 20 40 60 80 Load Current [Arms] 0 20 40 60 80 Max Ambient Temp. [˚C] ©2003 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No. 204 SERIES PCV. Rev. 111403 PAGE 2 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Series RPC Solid State Proportional Controller 15-40Amp • 120/240/480 Vac - OUTPUT • Uses Potentiometer for Economical Pow er Control • Industry Standard Package 8 MODEL NUMBERS RPC1215 RPC1225 RPC1240 The RPC series proportional controllers provide a cost effective method of controlling power in many different applications such as heaters, universal motors or incandescent lamps. A customer provided potentiometer is all that is required for control. All modules are supplied with KS100 protective cover. RPC2415 RPC2425 RPC2440 RPC4815 RPC4825 RPC4840 200-240 200-240 200-240 400-480 400-480 400-480 OUTPUT SPECIFICATIONS ➀ 90-130 90-130 90-130 Max. Load Current ➂ [Arms] 15 25 40 15 25 40 15 25 40 Min. Load Current, [mArms] 70 80 90 70 80 90 70 80 90 Transient Overvoltage [Vpk] 400 400 400 600 600 600 1200 1200 1200 Max. Surge Current, (16.6ms) [Apk] 150 250 625 150 250 625 150 250 625 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 Thermal Resistance Junction to Case [RθJC] 1.48 1.02 .63 1.48 1.02 .63 1.48 1.02 .63 94 260 1620 94 260 1620 94 260 1620 Max. Off-State Leakage Current @ Rated Voltage [mArms] 10 10 10 7 7 7 3 3 3 Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁ 500 500 500 500 500 500 500 500 500 Operating Voltage (47-63 Hz) [Vac] Maximum I2 t for Fusing, (8.3 msec.) [A2sec] Max. Turn-On Time ➃ [msec] Max. Turn-Off Time [msec] Power Factor (Min.) with Max. Load 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 Snubber (Internal) yes yes yes yes yes yes no no no INPUT SPECIFICATIONS ➀ Resistor, Variable [Ohms] ➃ 150K (1W) 150K (1W) 150K (1W) 1M (1/2W) 1M (1/2W) 1M (1/2W) 1M (1/2W) 1M (1/2W) 1M (1/2W) ©2003 CRYDOM CORP, Specifications subject to change without notice. GENERAL NOTES ➀ All parameters at 25˚C unless otherwise specified. ➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 ➂ Heat sinking required, for derating curves see page 2. ➃ Potentiometer should be selected with regards to line voltage isolation. W ARNING Control to load is not isolated, excercise care in handling the RPC products to avoid the risk of electric shock. FastFax Document No. 205 SERIES RPC. Rev. 111403 PAGE 1 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506 Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com Series RPC Solid State Proportional Controller 15-40Amp • 120/240/480 Vac - OUTPUT GENERAL SPECIFICATIONS Dielectric Strength, All Terminals to Base 2500 Vrms Ambient Operating Temperature Range -30 to 80˚C Ambient Storage Temperature Range -40 to 125˚C M ECHANICAL SPECIFICATIONS Weight: (typical) 3.2oz. (90g) Encapsulation: Thermally Conductive Epoxy Screws and Saddle Clamps Furnished, Unmounted Terminals: ~ W IRING DIAGRAM 1.10 (27.9) .45 (11.4) MOUNTING HOLE/SLOT 0.17 (4.3) DIA. 8-32 TERMINAL (2 PLACES ) CAUTION 1 2 PROPORTIONAL CONTROLLER 4 All dimensions are in inches (millimeters) All terminals are at Line Voltage Potential. 1 OUTPUT 2 1.87 (47.5) 4 3 INPUT 2.30 (58.4) 1.70 (43.2) 3 1.00 (25.4) 1.80 (45.7) Variable Resistance Screw Torque Requirements: 6-32 Screws - 10 in. lbs., 8-32 and 10-32 Screws - 20in. lbs. (Screws dry without grease.) .78 (19.8) .87 (22.1) 6-32 TERMINAL (2 PLACES) CURRENT DERATING CURVES 25A 15 NO HEATSINK 5 120 100 3˚C/W 2˚C/W 20 15 110 10 NO HEATSINK 5 3 6 9 12 Load Current [Arms] 15 20 40 60 1˚C/W .5˚C/W 40 5 Max Ambient Temp. [˚C] 10 15 20 25 Load Current [Arms] 20 40 60 100 2˚C/W 110 20 120 NO HEATSINK 0 80 90 1.5˚C/W 120 124 0 Power Dissipation 116 60 Base Plate Temp [˚C] 6˚C/W 25 Power Dissipation 10 95 1˚C/W 112 4˚C/W Base Plate Temp [˚C] 2˚C/W Power Dissipation 40A 30 Base Plate Temp [˚C] 15A 0 80 10 Max Ambient Temp. [˚C] 20 30 40 Load Current [Arms] 50 20 40 60 80 Max Ambient Temp. [˚C] PERCENTAGE ON vs . INPUT RESISTANCE RPC2415, RPC2425, RPC2440 RPC4815, RPC4825, RPC4840 100 100 80 80 80 60 40 Percentage ON 100 Percentage ON Percentage ON RPC1215, RPC1225, RPC1240 60 40 50 Hz 20 0 20 50 Hz 20 60 Hz 40 60 80 100 Input Resistance [k ] 120 140 60 Hz 0 0 20 40 50 Hz 60 Hz 0 60 0 200 400 600 800 Input Resistance [k ] 1000 1200 0 200 400 600 800 1000 1200 Input Resistance [k ] ©2003 CRYDOM CORP, Specifications subject to change without notice. FastFax Document No. 205 SERIES RPC. Rev. 111403 PAGE 2 OF 2 For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154 Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506