STIS SMOV Science Report September 17, 2009 STIS SMOV Status • • All STIS SMOV observations complete as of September 6, 2009 Most STIS SMOV analysis complete – Final superbias & super-dark reference files for SMOV period have been delivered – New CCD reference file delivered • Readnoise, gain, and CTE parameters – CCD TDS reference files delivered • Time-dependent sensitivity corrections to flux calibration • Open issues in STIS SMOV analysis – Waiting for additional Cycle 17 calibration observations to finalize MAMA TDS updates • Changes from pre-repair projections appear to be small – Monitoring of NUV MAMA dark is being continued by cycle 17 calibration program 11857 – Detailed writeups still pending for most activities STIS Activity PropID STIS SMOV Program Title Analysis Lead Visits Done Total Visits STIS02 11347 STIS03 Status Memory Load and Dump BS 1 1 Complete 11348 Science Data Buffer Check BS 3 3 Complete STIS04 11349 Mechanism Mini-Functional TW 1 1 Complete STIS05 11399 CCD Anneal (two anneal iterations) MW 6 6 Complete STIS06 11382 CCD Functional DL 4 4 Complete STIS07 11404 CCD Dark & Bias Monitor MW 90 105 Complete STIS08 11383 Aperture Wheel & Lamp Functional WZ 2 2 Complete STIS09 11384 STIS-to-FGS Alignment CP 1 1 Complete STIS10 11385 CCD Spectral Format Verification WZ 1 1 Complete STIS11 11386 External Focus Check CP 4 3+1 Complete STIS12 11387 Corrector and Focus Alignment CP - 8 Contingency STIS13 11388 CCD External Spectroscopic Quality TG 1 1 Complete STIS14 11400 CCD CTI Check PG 1 1 Complete STIS15 11401 CCD Spectroscopic Throughputs DL 3 3 Complete STIS16 11389 CCD Image and Pointing Stability TG 1 1 Complete STIS17 11350 FUV MAMA HV Recovery TW 4 4 Complete STIS18 11351 NUV MAMA HV Recovery TW 4 (+2F) 4 (+2F) Complete STIS19 11390 FUV MAMA Dark Measure CP 10 10 Complete STIS20 11402 NUV Dark Monitor CP 42(+3F) 20+52 Complete STIS21 11391 FUV Optical Format Verification WZ 2 2 Complete STIS22 11392 NUV Optical Format Verification WZ 2 (+2F) 2 (+2F) Complete STIS23 11393 FUV MAMA Spectroscopic Quality TG 1 1 Complete STIS24 11394 NUV MAMA Spectroscopic Quality TG 1 1 Complete STIS25 11403 MAMA Spectroscopic Throughputs DL 3 3 Analysis being finalized STIS26 11395 MAMA Image Stability TG 2 2 Complete NUV dark update • Post SM4 NUV dark current (black dots) much higher than expected – model as “expected dark” + “something extra” • Model as the “expected dark” (orange curve below) declining according to old behavior + an extra component Ae-(ΔE/T) e-t/τ • “extra” term appears to have stronger T dependence (ΔE ≈ 1.8 eV vs 1.5 eV) • Plot below compares different e-folding times for extra component τ =100 d (red) & τ = ∞ (blue)