STIS SMOV Science Report Friday, August 7, 2009 1 STIS Activity PropID STIS SMOV Program Title Analysis Lead Visits Done Total Visits STIS02 11347 STIS03 Status Memory Load and Dump BS 1 1 Complete 11348 Science Data Buffer Check BS 3 3 Complete STIS04 11349 Mechanism Mini-Functional TW 1 1 Complete STIS05 11399 CCD Anneal (two anneal iterations) MW 6 6 Complete STIS06 11382 CCD Functional DL 4 4 Complete STIS07 11404 CCD Dark & Bias Monitor MW 90 105 Ongoing STIS08 11383 Aperture Wheel & Lamp Functional WZ 2 2 Complete STIS09 11384 STIS-to-FGS Alignment CP 1 1 Complete STIS10 11385 CCD Spectral Format Verification WZ 1 1 Complete STIS11 11386 External Focus Check CP 4 3+1 Analysis STIS12 11387 Corrector and Focus Alignment CP - 8 Contingency STIS13 11388 CCD External Spectroscopic Quality TG 1 1 Complete STIS14 11400 CCD CTI Check PG 1 1 Complete STIS15 11401 CCD Spectroscopic Throughputs DL 3 3 Complete STIS16 11389 CCD Image and Pointing Stability TG 1 1 Repeat? LVPS changes? STIS17 11350 FUV MAMA HV Recovery TW 4 4 Complete STIS18 11351 NUV MAMA HV Recovery TW 2 (+2F) 4 (+2F) STIS19 11390 FUV MAMA Dark Measure CP 5 10 SMS 215 (Aug 7-8) STIS20 11402 NUV Dark Monitor CP 3 FAILED 20 SMS 208 + STIS21 11391 FUV Optical Format Verification WZ 2 2 Analysis STIS22 11392 NUV Optical Format Verification WZ 2 FAILED 2 (+2F) STIS23 11393 FUV MAMA Spectroscopic Quality TG 1 Analysis STIS24 11394 NUV MAMA Spectroscopic Quality TG 1 Analysis STIS25 11403 MAMA Spectroscopic Throughputs DL 3 Analysis STIS26 11395 MAMA Image Stability TG 2 Complete SMS 222 (Aug 13) 2 Near term activities • 215 SMS – NUV Darks - 5 visits • – Focus check (repeat after secondary move; uses CCD only) • – 1140302 217:17:57:39 - 217:19:29:39 1140303 217:20:51:48 - 217:23:17:24 1140305 218:14:38:05 - 218:16:20:25 FUV Dark measure • • 1139402 217:14:15.34 - 217:17:34.41 - external MAMA Sensitivity (both detectors) • • • – 1139302 216:22:01:40 - 217:00:37:57 - external NUV External Image Quality • – 1138611 215:05:59:04 - 215:06:56:28 FUV External Image Quality • – 215 (FAILED), 218, 221 1139011,12,13,14,15 219:14:17:43 - 220:00:25:00 222 SMS – NUV Spectral Format (repeat of failed visits from 208) • • – MAMA Darks • • • • • • – 1139203 225:12:00:00 - 225:12:23:34 1139304 225:12:23:34 - 225:12:53:30 11402A1,A2,A3,A4,A5,A6 222:13:27:56-222:22:38:56 1140207,08 224:12:53:59 - 224:18:58:45 1140231 225:18:30:00 - 225:18:58:56 1140232 226:18:30:00 - 225:18:58:56 1140209,10 227:10:32:12 - 226:20:49:30 1140231 228:18:30:00 - 225:18:58:56 Cycle 17 CCD sensitivity monitor • 11855 222:04:56:47 - 222:06:47:45 3 Focus Recheck 11386 • For June 4 visit, mean OII focus was about -8.5 microns • For August 3 visit, mean OII focus about -6 microns – Count rate after peakups was slightly lower than in June, but still within family 4 MAMA Spectroscopic Image Quality 11393/11394 • Took G140L and G230L spectra of DA WD GD153 using 52X0.1 aperture at various locations along slit – Also took reference spectra using 52X2 • Overall flux levels generally consistent with extrapolation of previous trends – details near Lyman alpha still being investigated – Other sensitivity monitor data still being analyzed 5 MAMA Spectroscopic Image Quality 11393/11394 - cont • Cross-dispersion (spatial) PSF indistinguishable from 2002 measurements. 6 MAMA Spectroscopic Image Quality 11393/11394 - cont • Relative throughput of 52X0.1 and 52X2 very close to previous results (perhaps slightly lower). 7 NUV MAMA Darks • Analysis of telemetry taken during visits with NUV MAMA HV on this week confirm that dark shows a short term dependence on temperature similar to or slightly steeper than normal NUV MAMA dark relation • No evidence so far that the extra dark rate is starting to decline – Previous model would have predicted 30% decline in about a week – Current NUV dark rate was measured in a variety of ways and not strictly comparable – Will obtain much better data over the next few days 8