NETSURETM 501 DC Power System, -48 V DC, 1.7 – 20.4 kW, 35 – 420 A Benefits :9Fem[h\eh 8ki_d[iiø9h_j_YWb9edj_dk_jo NetSure 501 is the new more compact, and yet more flexible, Cost and space effective system configurations thanks to smart and flexible Multi Function Unit, MFU. (The MFU houses the controller, DC and Battery breakers, shunts, alarm boards and optionally disconnection of loads and/or batteries. DC power system from Emerson. It is especially developed for Wide AC input window with high rectifier DC output. possibility to very space effectively house both batteries and DC AC current input limitation possible on rectifiers. This function enables the user to employ 10A AC breakers, or smaller, if desired. Based upon factory pretested units, subrack and complete the needs of typical telecom applications in the range between 1.7-20.4 kW. The packaging of the NetSure 501 system configurations gives the power system in 400 mm deep configurations. configurations, new customer configurations and adaptations can quickly, easily and cost effectively be created with NetSure 501, and you can trust that the telecom norms and standards specified for the product are always adhered to. As the business grows, NetSure 501 is easily extended with additional capacity and can be upgraded with supplementary features and functions during live operation. With NetSure 501 the process of finding a suitable location for an application and its power supply is facilitated, thanks to the wide tolerance window of NetSure 501 when it e.g. comes to operating temperature, AC input window of AC input breaker size. 6.8 kW 15.3 kW 17.0 kW NETSURETM 501 DC Power System, -48 V DC, 1.7 – 20.4 kW, 35 – 420 A Technical Specifications Emerson Network Power Energy Systems AB SE-141 82 Stockholm, Sweden Phone: +46 8 721 60 00 Fax: +46 8 721 71 77 Typical Applications Base Transceiver Stations (BTS) and Node B Small Microwave units Digital Subscriber line (DSL) Fiber repeaters Point of Presence (PoP) Digital Loop Carrier Electrical System Specification Nominal system voltage: Adjustable range for operating voltage: Output power, system: Input voltage, nominal: Input voltage, permitted variation: Line frequency: Maximum AC input fuse: -48 V DC -42 V DC to 58 V DC 20.4kW @ Vout > 48 V DC 200 – 250 V AC, 1 phase ±20% 85 – 300 V AC ±10% 45 – 65 Hz normally 16A, but the rectifier can limit the maximum input AC if smaller AC input fuse is required Mechanical system Specification Dimensions: (HxDxW), wall/battery rack mounted cabinet: Dimensions (HxDxW), stand-alone power cabinet: Dimensions (HxDxW), stand-alone power cabinet: Details: Front access and top cabling 360/450x400x600 mm 800/1200/1600/1800x400x600 mm 1200/1600/1800/2000/2200x600x600 mm Environmental System Specification Temperature range, operating Relative humidity, operating EMC Safety Cabinet -5°C to +65°C (full power up to +45°C) <90% EN 300 386-2 class B, FCC part 15 class B IEC 60950, EN 60950-1 IP 20 System units Cabinet(s) Control units available AC terminals Rectifiers / Power Supply Units Multi Function Unit, 3U high :9Fem[h\eh 8ki_d[iiø9h_j_YWb9edj_dk_jo Wall mounted, battery rack mounted or standard stand-alone cabinets Standard Control Unit (see separate SCU datasheet) Advanced Control Unit (see separate ACU datasheet) AC terminals for up to 12 rectifiers Various connection types R48-1700 (see separate rectifier data sheet) Up to 12x R48-1700 rectifiers (20.4 kW) per cabinet 1 position for controller housing SCU or ACU, size 2x3 U) 32x13mm circuit breaker positions OR 23x18mm circuit breaker positions for DC distribution breakers and battery breakers 0 – 2 contactors for optional disconnection levels of loads and/or batteries Emerson Network Power Energy Systems, North America 1122 ”F” Street, Lorain, OH 44052 Phone: 440-246-6999 Fax: 440-246-4876 www.emersonnetworkpower.com/ energysystems/ Emerson Network Power Co Ltd., China No. 1 Kefa Rd., Science & Industry Park Nanshan District 518057, Shenzhen, China Phone: 86-755-860 108 08 www.emersonnetworkpower.com.cn For global contact, visit: www.emersonenergy.com EN/LZT 145 279 RA © Emerson Network Power Energy Systems 2006 Optional units Extension DC distribution unit AC distribution SM-AC (Supervision Module AC) SM-BAT (Supervision Module Batteries) SM-IO (Supervision Module for generic equipment) A B C D E F G H I 40x13 mm circuit breaker positions OR 28x18 mm circuit breaker positions AC distribution for up to 12 rectifiers Optional surge protection, RCD and service outlets See separate data sheet See separate data sheet See separate data sheet Cabling space DC distribution unit (extension, optional) Cabling space (incl. AC terminals if no distribution) Multi function unit Connection board Controller Rectifier rack Rectifier rack (extension) AC distribution unit (optional) A B C E D F G H I ;c[hiedD[jmehaFem[h$ J^[]beXWbb[WZ[h_d[dWXb_d] 8ki_d[iiø9h_j_YWb9edj_dk_joJC$ 79Fem[h 9edd[Yj_l_jo :9Fem[h ;cX[ZZ[Z9ecfkj_d] ;cX[ZZ[ZFem[h Ced_jeh_d] Ekji_Z[FbWdj Fem[hFhej[Yj_ed Fh[Y_i_ed9eeb_d]9edjhebi HWYai?dj[]hWj[ZIebkj_edi I[hl_Y[i Ikh][Fhej[Yj_ed ;c[hiedD[jmehaFem[h$Yec ;c[hiedD[jmehaFem[hWdZj^[;c[hied D[jmehaFem[hbe]eWh[jhWZ[cWhaiWdZ i[hl_Y[cWhaie\;c[hied;b[Yjh_Y9e$ (&&,;c[hied;b[Yjh_Y9e$