QUICK SPEC STRUCTURAL CONCRETE – ROOF MATE Method

advertisement
 QUICK SPEC
STRUCTURAL CONCRETE – ROOF MATE
NOTE: The following “Quick Spec” is an abbreviated specification and is not meant to replace the detailed specification. Read
the entire 3-Part CSI System Specification prior to starting the project.
Method

Spray, roller, or brush
Requirements





Moisture survey recommended.
Roof must be clean, dry, and tight.
Adhesion test required to ensure proper adhesion to substrate(s).
Apply at 50°F (10°C) and rising with no rain or freezing temperatures in forecast for 24 hours.
Concrete must be fully cured (typically 28 days).
Application
Instructions
1.
2.
Conduct moisture survey to ensure concrete contains less than 8% moisture.
Repair or replace damaged or deteriorated sections with like materials, allowing cementitious
products to cure properly.
Power-wash roof. It is recommended to use United Cleaning Concentrate (UCC) to clean the
roof. Allow the roof to completely dry.
Prime per the chart below.
Treat structural joints with backer rod and urethane or silicone sealant, then treat with Roof
Mate Butter Grade Flashing and Roof Mate Fabric.
Treat all roof penetrations, drains, curbs, and scuppers with Roof Mate Butter Grade Flashing
and Roof Mate Fabric.
Apply coating per the chart below.
3.
4.
5.
6.
7.
STRUCTURAL CONCRETE SPECIFICATION
ROOF MATE
Primer
Product Epoxy Primer Primer (Gal/Sq)
0.50
10 Year
Epoxy Primer Epoxy Primer 15 Year
0.50
0.50
Product (Choose one)
1st Coat
Coating
2nd Coat
1.50
Warranty
Limited Emerald Diamond Warranty Pledge
Pledge
Coating
(Gal/Sq)
DFT*
1.50
3.00
25.5
Yes
Yes
No
1.50
1.50
3.00
25
Yes
Yes
No
Roof Mate
Roof Mate QS
1.50
1.50
1.50
4.50
38
Yes
Yes
No
Roof Mate
Roof Mate QS
Roof Mate HT Roof Mate TCM
3rd Coat
Epoxy Primer 0.50
Roof Mate HT 1.50
1.50
1.50
4.50
37.5
Yes
Yes
No
Epoxy Primer 0.50
Roof Mate TCM
1.50
1.50
1.00
4.00
40
Yes
Yes
No
* Dry Film Thickness (DFT) does not include Primer, uses the average % solids by volume between the two coatings, is rounded to nearest mil, and is theoretical. Actual DFT will vary dependent on substrate profile, application technique & waste factor.
Download