M-Weld Snap-On Coping

advertisement
M-Weld Snap-On Coping
ORDER / SPECIFICATION FORM
(For Coping on Masonry Parapet)
SNAP-ON COPING CAP
FORMED IN 10'-0" LENGTHS
20GA CLIP,
12" WIDE 3
CONCEALED JOINT
SPLICE, 6" WIDE w/
FORMED SIDEWALLS
FOR WATER CONTROL
1 1/2"
3/4"
90°
90°
FACE
MIN=3"
MAX=12"
BACK
MIN=3"
MAX=6"
MEMBRANE
BY OTHERS
1-1/4" TAPCON SCREW,
PROVIDED (6 PER CLIP)
COVERAGE
1
POP RIVET, PROVIDED (2 PER SPLICE)
3/8"
ALLOWANCE
FOR WALL
VARIATION
5/8"
WALL
MIN=6" 2
MAX=32"
1 Face = coverage (should extend a min of 1" below water resistant wall surface)+2 1/8".
2 Contact manufacturer for coping design on walls outside these parameters.
3 Clip spacing; see table on back page. Clip has a different profile on walls 20" to 32"
(See profile on back page).
4 0.040 ALUM & 24GA GALV coping cap only available for wall sizes 6" to 24".
QUANTITY
Total LF (10'-0" pcs)
Miters (___ Outside, ___ Inside)
End Caps (___ Left, ___ Right)
End Caps Inserts (__Left, __ Right)
End Terms (___ Left, ___ Right)
Radius LF (5'-0" pcs)
Radius to Straight Miters
Radius End Conditions
MATERIAL
THICKNESS
Vaulted LF (5'-0" pcs)
0.040 4
Aluminum
Vaulted to Straight Miters
0.050
Galvanized
Tee Miters
0.063
Stainless Steel
Zee Miters
0.080
Transition Miters, (Attach
0.125
Sketches)
Ridge Miters,
24GA 4
Valley Miters,
22GA
Special Corners
ACCESSORY TYPE
Welded
Metal-Lok
FINISH
Mill Finish
Prefinished Kynar
Post Finished Kynar
Prefinished Anodize
Post Finished Anodize
COLOR
0.063 prefinished Kynar is only available in Statuary Bronze, Medium Bronze, Sandstone, Dove Gray, Ascot White, Forest Green & Bone White
®
APPROVALS
ANSI/SPRI
ES-1 TESTED
(Contact manufacturer for verification of test
report data on your project)
CUSTOMER APPROVAL
Approved for Fabrication
Approved with Changes Authorized Customer Signature
Disapproved, Resubmit
Title
Date
Job Name:
Customer:
By:
Job #:
Representative:
Date:
Architect:
Sheet
Location:
Rev. 12/15
1 Campus Drive - Parsippany, NJ 07054 - Phone: (877) GAF-ROOF / (877) 423-7663
www.gaf.com
of
M-Weld Snap-On Coping
CLIP PROFILE FOR
WALLS 20" TO 32"
CLIP SPACING
WALL SIZE
SPACING
≤ 16"
(less than or equal to)
> 16"
60" O.C.
1/4"
GAP
40" O.C.
(greater than)
COPING CAP
CONCEALED
JOINT SPLICE
20GA CLIP
SEE NOTE
BELOW
MEMBRANE
BY OTHERS
SEE NOTE
BELOW
24"
OUTSIDE MITER
SEE NOTE
BELOW
SEE NOTE
BELOW
END CAP
LEFT HAND SHOWN
24"
INSIDE MITER
Standard coping miter leg lengths:
23 1/4" for 6" to 16" wall widths
29 1/4" 16" to 23" wall widths
custom lengths for wall widths > 23"
Standard coping miter angle is 90°
For special miter requirements, attach sketches or consult manufacturer for assistance.
Rev. 12/15
END TERM
RIGHT HAND SHOWN
Download