M-Weld Snap-On Coping ORDER / SPECIFICATION FORM SNAP-ON COPING CAP FORMED IN 10'-0" LENGTHS 20GA CLIP, 12" WIDE 3 CONCEALED JOINT SPLICE, 6" WIDE w/ FORMED SIDEWALLS FOR WATER CONTROL 1 1/2" 3/4" 90° FACE MIN=3" MAX=12" COVERAGE 1 90° BACK MIN=3" MAX=6" MEMBRANE BLOCKING BY BY OTHERS CONTRACTOR #9 x 1-1/2" SS SCREW w/ WASHER, PROVIDED (4 PER CLIP) 1-1/2" SS RING SHANK NAIL, PROVIDED 5/8" QUANTITY 1-1/2" SS RING SHANK NAIL, PROVIDED FOR FACES GREATER THAN 6" ONLY WALL MIN=6" 2 MAX=32" 1 Face = coverage (should extend a min of 1" below water resistant wall surface)+2 1/8". 2 Contact manufacturer for coping design on walls outside these parameters. 3 Clip spacing; see back page. Clip has a different profile on walls 20" to 32" (See profile on back page). 4 0.040 ALUM & 24GA GALV coping cap only available for wall sizes 6" to 24". Total LF (10'-0" pcs) Miters (___ Outside, ___ Inside) End Caps (___ Left, ___ Right) End Caps Inserts (__Left, __ Right) End Terms (___ Left, ___ Right) Radius LF (5'-0" pcs) Radius to Straight Miters Radius End Conditions MATERIAL THICKNESS Vaulted LF (5'-0" pcs) 0.040 4 Aluminum Vaulted to Straight Miters 0.050 Galvanized Tee Miters 0.063 Stainless Steel Zee Miters 0.080 Transition Miters, (Attach 0.125 Sketches) Ridge Miters, 24GA 4 Valley Miters, 22GA Special Corners APPROVALS ANSI/SPRI ES-1 TESTED 3/8" ALLOWANCE FOR WALL VARIATION (Contact manufacturer for verification of test report data on your project) ACCESSORY TYPE Welded Metal-Lok FINISH Mill Finish Prefinished Kynar Post Finished Kynar Prefinished Anodize Post Finished Anodize COLOR CUSTOMER APPROVAL Approved for Fabrication Approved with Changes Authorized Customer Signature Disapproved, Resubmit Title Date Job Name: Customer: By: Job #: Representative: Date: Architect: Sheet Location: Rev. 12/15 1 Campus Drive - Parsippany, NJ 07054 - Phone: (877) GAF-ROOF / (877) 423-7663 www.gaf.com of M-Weld Snap-On Coping CLIP PROFILE FOR WALLS 20" TO 32" CLIP SPACING WALL SIZE SPACING ≤ 16" (less than or equal to) > 16" 1/4" GAP 60" O.C. 40" O.C. (greater than) COPING CAP CONCEALED JOINT SPLICE 20GA CLIP SEE NOTE BELOW MEMBRANE BY OTHERS SEE NOTE BELOW 24" OUTSIDE MITER SEE NOTE BELOW SEE NOTE BELOW END CAP LEFT HAND SHOWN 24" INSIDE MITER Standard coping miter leg lengths: 23 1/4" for 6" to 16" wall widths 29 1/4" 16" to 23" wall widths custom lengths for wall widths > 23" Standard coping miter angle is 90° For special miter requirements, attach sketches or consult manufacturer for assistance. Rev. 12/15 END TERM RIGHT HAND SHOWN