systems ICS-900 Ion Chromatography System The ICS-900 is an integrated, dualpiston, isocratic ion chromatography system that performs "no compromise" IC separations. The system is designed for ease of use, providing fast startup times and reliable, stable performance for your demanding applications. Built with the aim of maintaining low operating costs, the ICS-900 uses proven and reliable technologies to deliver results you can count on. Low-Cost Reliability • Sensitive, stable, heated conductivity detection for precise results • MMS™ 300 suppression with displacement chemical regeneration (DCR) technology for drift free baseline and ease-of-use • Flexible pump flow range to support 2, 3, and 4 mm isocratic anion and cation columns • Dual-piston, serial pumping system with PEEK™ flowpath for low maintenance costs and maximum up-time • All-polymeric flow pathway to eliminate contamination and corrosion Passion. Power. Productivity. • Chromeleon® Chromatography Management Software for full control, quality integration, and versatile reports to exceed all your data processing needs • USB connectivity for fast, troublefree instrument connection and configuration • Integrated IQ/OQ/PQ to routinely assure the quality of your results • Compatible with all Dionex IC autosamplers. The AS40 autosampler is recommended for economical unattended operation, including sample filtration • Compatibility with a broad range of Dionex polymeric separation columns for unparalleled application flexibility and reliability 3 Column: Eluent: 1 7 2 Flow Rate: Inj. Volume: Temperature: Detection: 4 5 6 µS Sample: Peaks: 0 5 Minutes 10 15 IonPac® AS14, 2 mm 0.8 mM carbonate/ 0.1 mM bicarbonate 0.3 mL/min 2.5 µL Ambient Suppressed conductivity, AMMS® 300, 2 mm Seven anion standard 1. Fluoride 2. Chloride 3. Nitrite 4. Bromide 5. Nitrate 6. Phosphate 7. Sulfate Column: Eluent: Flow Rate: Inj. Volume: Temperature: Detection: 4 2 6 5 1 3 µS Sample: 4 mg/L 20 20 20 20 40 20 Peaks: 0 6 Minutes 25004 12 IonPac CS12A, 3 mm 20 mM MSA 0.5 mL/min 10 µL Ambient Suppressed conductivity, CMMS® 300, 4 mm, 100 mM TBAOH regenerant Six cation standard, 1/50 dilution 1. Lithium 2. Sodium 3. Ammonium 4. Potassium 5. Magnesium 6. Calcium 1 mg/L 4 5 10 5 10 25434 Overlay of cation separations performed on the ICS-900 using a 3 mm IonPac CS12A cation-exchange column. Results show high reproducibility. Peak areas and retention times are highly reproducible and baselines are stable and noise-free, as demonstrated in these overlays of anion determinations (n=20). Column: Eluent: 2 10 Flow Rate: Inj. Volume: Temperature: Detection: 3 µS Sample: 1 4 5 Peaks: 6 7 0 0 5 Minutes 10 15 IonPac AS14, 2 mm 0.8 mM carbonate/ 0.1 mM bicarbonate 0.3 mL/min 2.5 µL Ambient Suppressed conductivity, AMMS 300, 2 mm Seven anion standard 1. Fluoride 2. Chloride 3. Nitrite 4. Bromide 5. Nitrate 6. Phosphate 7. Sulfate 4 mg/L 20 20 20 20 40 20 IonPac AS14 2 mm column for reduced reagent usage with high performance and fast separation. 1 Application and column flexibility: 2, 3, and 4 mm isocratic columns 2 Outstanding access to chromatography components 3 Ultra reliable, low carryover, electric Rheodyne injection valve 4 Dual piston, serial pumping system with stability from 0.01 to 5.00 mL/min at pressures to 5000 psi 5 Heated conductivity cell and MMS 300 suppressor for stable, noise-free results 5 2 1 3 4 2 25007 ICS-900 SYSTEM SPECIFICATIONS Analytical Pump and Hydraulics Type: Serial dual-reciprocating piston, microprocessor-controlled constant stroke, variable speed Construction: Chemically inert, metal-free PEEK pump heads and flow paths compatible with aqueous eluents of pH 0–14 and reversed-phase solvents Pump Operating Pressure: 0–35 MPA (0–5000 psi) Flow Rate Range: 0.00 to 5.00 mL/min with settable flow increment at 0.01 mL/min without changing pump heads Flow Precision: <0.1% Flow Accuracy: <0.1% Pressure Ripple: <1% Eluent Bottle Pressure: No gas required Vacuum Degasser: Optional with external vacuum degasser Gradient Capabilities: Optional with RFC-30 Eluent Generation: Optional with RFC-30 Injection Valve 6-port, 2 position Rheodyne valve, electrically actuated Column Heater/Thermostat Optional External Heater, CTS-10, 25 to 85 °C, minimum 5 °C above ambient Suppressor Compatibility Chemical Suppression: Yes, anion and cation, 2 and 4 mm Electrolytic Suppression, Self-Regenerating: Optional with RFC-10 Electrolytic Suppression, Self-Regenerating, External Water Optional with RFC-10 Suppression Capacity: Anion SRS® 300 (4 mm): 200 µeq/min Cation SRS 300 (4 mm): 110 µeq/min Anion SRS 300 (2 mm): 50 µeq/min Cation SRS 300 (2 mm): 37.5 µeq/min Anion MMS 300 (4 mm): 150 µeq/min Cation MMS 300 (4 mm): 150 µeq/min Anion MMS 300 (2 mm): 37.5 µeq/min Cation MMS 300 (2 mm): 37.5 µeq/min Anion AES: 25 µeq/min Cation AES: 25 µeq/min Void Volume: SRS 300 (4 mm): <50 µL SRS 300 (2 mm): <15 µL MMS 300 (4 mm): <50 µL MMS 300 (2 mm): <15 µL AMMS-ICE 300 (4 mm): <50 µL AMMS-ICE 300 (2 mm): <15 µL Anion AES: <35 µL Cation AES: <35 µL Sequential Suppression for Anions: Yes, MMS 300 + CRD 300 Suppressor Wear Parts: None; peristaltic pump and inline filters not required Conductivity Detector Type: Bipolar heated conductivity cell, microprocessor-controlled digital signal processing over the range 0–10,000 µS/cm Detector Linearity: 1% Maximum Cell Pressure: 10 MPa (1500 psi) Resolution: 0.0047 nS/cm Displacement Chemical Regeneration: Yes, anion and cation, 2 and 4 mm 3 Cell Calibration: Factory calibrated as a new system and calibrated in the field individually with memory retention and transfer Flow Cell Chemical Compatibility (Standard): Fully compatible with all typical ion chromatography eluents, including MSA Autosampler Automation Using Autosampler: Yes, Dionex AS40, AS-HV, and AS Autosamplers or third party Sequential/Simultaneous Injection: Yes, depending on autosampler capabilities Automated Dilution: Yes, available with AS Autosampler Dilution Factor, AS Autosampler: 1:1 to 1:1000 Dilution Time, AS Autosampler: 15 s with sample overlap Inline Sample Degassing: Optional with CRD 200/CRD 300 Inline Filtration: Optional with AS40 Autosampler or inline filter Automation Flexibility: High, conditionals using Chromeleon software and post run features Semiautomated System Qualification: Yes, IQ/OQ/PQ ICS-900 SYSTEM SPECIFICATIONS (continued) System Software Chromeleon Chromatography Management Software, requires Windows 2000, XP, or Vista • Automated ProcedureWizards • System Wellness and Predictive Performance • Virtual Column Simulator (evaluation mode standard, isocratic and gradient optional) • Application Templates • Multivendor Automation Support of 3rd Party (fully controls over 200 instruments from more than 25 manufacturers, including GC, HPLC, and MS) • Customizable System Control Panels • System Status Virtual Channels • Power Failure Protection • Sequential Injection • System Trigger Commands and Conditionals • • • • • Daily Audit Trail Sample Audit Trail Multiple Network Control and Network Failure Protection System Calibration Storage (factory, present, and previous; completely user selectable) Customized Reporting Physical Specifications Dimensions (h × w × d): 33 cm × 24 cm × 40 cm 13 in × 9.5 in × 15.7 in Weight: 10 kg (22 lb) Power Requirements: 100 to 240 V ac, 50 to 60 Hz, autoranging System Flow Path: All polymeric (PEEK), anion or cation configurations Ordering Information To order in the U.S., call (800) 346-6390 or contact the Dionex Regional Office nearest you. Outside the U.S., order through your local Dionex office or distributor. Refer to the following part numbers. ICS-900 Ion Chromatography System ICS-900 Ion Chromatography System,..........................................................067552 with Chromeleon SE and PC ICS-900 Ion Chromatography System,..........................................................067551 with Chromeleon SE, without PC ICS-900 Ion Chromatography System expansion unit..................................067550 MMS is a trademark and AMMS, CMMS, Chromeleon, IonPac, and SRS are registered trademarks of Dionex Corporation. PEEK is a trademark of Victrex PLC. Windows is a registered trademark of Microsoft Corporation. Passion. Power. Productivity. Dionex Corporation North America Europe Asia Pacific 1228 Titan Way P.O. Box 3603 Sunnyvale, CA 94088-3603 (408) 737-0700 U.S. (847) 295-7500 Canada (905) 844-9650 Austria (43) 1 616 51 25 Benelux (31) 20 683 9768; (32) 3 353 4294 Denmark (45) 36 36 90 90 France (33) 1 39 30 01 10 Germany (49) 6126 991 0 Ireland (353) 1 644 0064 Italy (39) 02 51 62 1267 Sweden (46) 8 473 3380 Switzerland (41) 62 205 9966 United Kingdom (44) 1276 691722 Australia (61) 2 9420 5233 China (852) 2428 3282 India (91) 22 2764 2735 Japan (81) 6 6885 1213 Korea (82) 2 2653 2580 Singapore (65) 6289 1190 Taiwan (886) 2 8751 6655 South America Brazil (55) 11 3731 5140 www.dionex.com LPN 2032-01 PDF 07/08 ©2008 Dionex Corporation