ONDULINE ROOFING SHEETS Thermal and acoustic qualities OFITECH for OFIC SA 35, rue Baudin 92300 LEVALLOIS PERRET e-mail: export@ondulinecom LL, May 2008 Title of the presentation Date Thermal and Acoustic Qualities of ONDULINE sheets Heat Flow Warm Cold 1) Thermal qualities : Thermal conductivity : λ Ability of a material to conduct HEAT • • Thermal resistance : R Ability of a product to reduce HEAT conduction (most of the time heat transmission coefficient K=1/R is recorded) Title of the presentation Date Thermal conductivity λ : (Ability of a material to conduct HEAT) Examples (materials): Low • Expansed Polystyrène : 0.034 W/m.°C • Cork : 0.1 W/m.°C • Bitumen : 0.17 W/m.°C • Wood (pin): 0.36 W/m.°C • Fiber cement : 0.95 W/m.°C • Brick (Clay) : 1.15 W/m.°C • Reinforced concrete : 1.75 W/m.°C High • Iron : 52 to 80 W/m.°C The lower the λ value is, the lower HEAT conduction will be. 33 Thermal conductivity of ONDULINE: (French L.N.E certificate) Performed according to NF X 10-021 Test report DMAT/1707916 λ= 0.099 W/m.°C Title of the presentation Date Thermal conductivity λ : Examples (materials): • Expansed Polystyrène : 0.034 W/m.°C • Cork : 0.1 W/m.°C • Bitumen : 0.17 W/m.°C • Wood : 0.36 W/m.°C • Fibre cement : 0.95 W/m.°C • Brick (Clay) : 1.15 W/m.°C • Reinforced concrete : 1.75 W/m.°C • Iron : 52 to 80 W/m.°C • Low High ONDULINE : 0.099 W/m.°C ONDULINE value is very closed to λ Cork 55 Thermal RESISTANCE R : Performed on the product Thermal Insulation test performed by Sirim QAS International Sdn Bhd Test method: ISO 8990:1994 Test report: 2004CB1300 Date: 23 August 2004 (Onduline sheet) 66 Resistance of Heat Transmission R Official laboratory test: 16°C cooler 16°C difference between high and low temperature rooms R= 0.178 m².°C/W K= 1/R=5.6 W/m².°C Thermal Insulation test performed by Sirim QAS International Sdn Bhd Test method: ISO 8990:1994 Test report: 2004CB1300 Date: 23 August 2004 Thermal RESISTANCE Examples or equivalent : ONDULINE sheet R=0.178 m².°C/W is equivalent to : ~ 2 cm of cork ~ 7 cm of wood ~ 21 cm of bricks (clay) ~ 32 cm of concrete Etc…………. Warm Cooler (Until T1-16°C 88 Thermal RESISTANCE A building is cooler when compared to metal roof Customers testimonies : Outside temperature Onduline = cooler Metal roofs = hotter Thermal and acoustic Qualities of ONDULINE sheets SOUND Emission 2) Acoustic quality : Acoustic attenuation : SRI Ability of a product to reduce SOUND transmission Absorption (testing) Reception Expressed in decibels (dB) (insulated box) Title of the presentation Date Comfort Roof - Sound Absorption (3) Noise reduction SRI=28 dB Performed according to BS EN 20354. Test report N°C/95/CL/1896/1 Comfort Roof – Impact noise Absorption Your building remains silent under tropical rain Customers testimonies : Rainfall (shower) Onduline = (almost) silence Listen & compare Metal roof = noise Comfort Roof - Impact noise Absorption No “drumming” effect at all under tropical rain Onduline material being 3mm thick and relatively soft, sound of tropical rain is greatly reduced; there is no “drumming” effect at all Thermal and acoustic Qualities • Thermal conductivity : λ= 0.098 W/m.°C Thermal resistance : R= 0,178 m²/°C.W • Acoustic attenuation : SRI =28 dB, (Sound Reduction Index) Title of the presentation Date YOUR QUESTIONS….? Title of the presentation Date THANK YOU FOR YOUR QUESTIONS. Title of the presentation Date