CORRIGENDUM The bidders are advised to notice the corrections made in the specification for some of the items in the Specifications and Bid Document of JNTUK which was kept in the University Website on 02.10.2014. The bidders who have already submitted their bids can submit a revised bid incorporating the new specifications. The last date for submission of tenders/revised tenders is extended to 18.10.2014 upto 3.00 pm. Jawaharlal Nehru Technological University Kakinada Kakinada – 533 003, Andhra Pradesh SPECIFICATIONS & BID DOCUMENT Supply of the following items for the University Central Library 1. Furniture 2. Computers 3. Software 4. Equipment 5. Generator Important dates and details Cost of the Tender Document is Rs.1,000/- The Advt. of Tender Notice appears in News Papers on 02-10-2014. Tender Documents can be downloaded from web site www.jntuk.edu.in Terms and Conditions are available on JNTUK website from 02-10-2014. Last date for submission of sealed Tenders: 18-10-2014 up to 03.00 p.m. Date of Opening of Bid Tenders are to be submitted to the following address in person or by post The Registrar, JNT University Kakinada, Kakinada- 533 003. Contact Phone No’s: 9963993464, 0884-2300874. : 18-10-2014 up to 04.00 p.m. Page 1 of 8 SCHEDULES FOR THE TENDER WORKS 1. FURNITURE SPECIFICATIONS Sl. No Description of Item Specifications Qty (No’s) 1.9 Non Revolving Reading Chairs Powder coated MS 14G tubular frame - Moulded arms rest-2” Kurlon PU foam cushioned seat & back with good cloth covering 228 1.10 Modular Table for Digital Library to place computers along with revolving chairs. Modular Partition for workstations: Supply and installation in position modular partition tile based system made of 65 +/-5 mm thick Extruded Aluminium sections (for longevity and to avoid rust mainly for coastal areas) Powder coated of approved shade with 9 mm thick Pre laminated double skin partition on both sides with 45 mm central gap and race way provision in skirting with pin board(soft board), Hard board with fabric material and white marker board and/or balance with laminate tile board Configuration: Any Tile pattern: 1 or 2 or 3 or 4 Tiles all complete with cost of materials, labour,transportation. Installation: At client's place, Stability: Perfect sturdiness, Modularity: Can be dismantled, shifted, upgraded, Sharp edges: Nil. Partition Height: 1200mm. Table top: Supply and installation in position 25mm thick prelaminated particle boards of approved colour on both sides with 2mm thick edge banding all complete with cost of materials, labour, transportation. SIZE: 900mm width x 600mm depth. Gable ends: Gable ends using 25mm thick PLPB of approved colour on both sides. Middle Partition: Middle partitions using 25mm thick PLPB of approved colour on both sides. Key board tray: Supply and fixing of Metallic Key board tray with mouse pad on sliding channels under table top. CPU trolleys: Supplying & placing in position below work stations- movable type powder coated CRCA Sheet with 4 No's caster wheels with lockable type etc., Complete. 120 Quoted Rate (Rs.) Page 2 of 8 2. COMPUTERS SPECIFICATIONS Sl. No 2.1 Name of the Item Servers with High Configuration with Rack for Digital Library Specifications Chassis CPU CPU L3 CACHE Memory Motherboard Memory Memory Protection HDD Bays Optical drive Bay HDD carrier Hard disk drive for server Storage Controller 2 U Rack Mountable One Octa core Intel E5-2650 v2 series Processor 2.0 GHz Server should provide an intelligent socket that would ease the installation of CPU to avoid errors caused by misinserting processors during install or upgrade. Quantity (No’s) Quoted Rate (Rs.) 02 20MB L3 cache Intel® C602JJ Series Chipset Intel®E5-2600v2 Processor Family 64GB with DDR3 Registered (RDIMM) memory, operating at 1600MHz (v2 proc). Server should support RDIMM, UDIMM, LRDIMM, HCDIMM Proposed memory should support reliably identify and verify whether installed memory has passed the rigorous OEM qualification and testing process to increase system reliability Advanced ECC, Chipkill memory mirroring and memory bank sparing Online Spare Lockstep mode Minimum 8 (scalable upto 16)Hot Plug 2.5" hard disk bays/ + CDROM/DVD Bay / 25 Hot Plug 2.5" drive bays One optical drive bay to install DVD-RW Hard disk drive should support "Do Not Remove" caution indicator to avoid human errors in replacing failed HDD 2 X 600 GB 15K rpm 1.5” SAS HDD 12X600GB SAS 10K Rpm HDD Dual Controller, Dual power supply, 4 port SAS Card PCIe 3.0 based SAS Raid Controller with RAID 0/1/1+0/5/5+0 with 512MB battery backed write cache (onboard or in a PCI Express slot). Controller should support 512MB/1GB/2GB flash backed write cache Controller should Page 3 of 8 Networking features Ports Bus Slots Optical drive Power Supply PFA Cooling Industry Standard Compliance support caching the most frequently accessed data ("hot" data) onto lower latency high performing SSDs to dynamically accelerate application workloads. Server should support one of the following: 1. 1Gb 4-port network adaptor supporting advanced features such as Large Send offload capability, TCP checksum and segmentation, VLAN tagging, MSI-X, Jumbo frames, IEEE 1588, and virtualization features such as VMware Net Queue and Microsoft VMQ. 2. 10Gb 2-port Ethernet adaptor supporting enterprise class features such as VLAN tagging, adaptive interrupt coalescing, MSI-X, NIC teaming (bonding), Receive Side Scaling (RSS), jumbo frames, PXE boot and virtualization features such as VMware Net Queue and Microsoft VMQ. 3. 10 Gb 2-port Adapter providing Ethernet and iSCSI or Fibre Channel Over Ethernet (FCoE) connectivity using Converged Enhanced Ethernet (CEE) standards. This adaptor should support Hardware acceleration and offloads for stateless TCP/IP, TCP Offload Engine (TOE), Fibre Channel over Ethernet (FCoE), Jumbo frames and iSCSI. USB 2.0 support With 7 total ports: (2) ports up front; (4) ports in back; (1) port internal and1 DB 15 video, 1DB 9 Serial , 1 RJ45. Six PCI-Express slots, atleast 5 with PCIe 3.0 (twox16 and three x8 slots) DVD/CD-RW combo drive Dual Redundant Power Supplies PFA support for CPU, Memory, Hard disk, Fans, VRM Moudules Calibrated Vectored cooling with upto 4 N+N redundant hot swap fan (3 standard, additional fan with second processor) each fan has two motors. ACPI 2.0 Compliant, PCIe 3.0 Compliant, PXE support, WOL Support, Microsoft® Logo certifications, USB 2.0 Support Page 4 of 8 Security OS Support Warranty Remote Management (optional) Power-on password Serial interface control Administrator's password Server should also support Trusted Platform Module microcontroller chip that can securely store artifacts used to authenticate the server platform. These artifacts can include passwords, certificates and encryption keys. Microsoft Windows Server, Microsoft Windows Server HyperV, Red Hat Enterprise Linux (RHEL), Red Hat Enterprise Linux Virtualization, SUSE Linux Enterprise Server (SLES), SUSE Linux Enterprise Server with XEN Oracle Solaris for x86/x64 based Systems, VMware, Citrix Xen Server 3 year onsite warranty with 24X7 within 4 hrs response. Pre failure warranty on CPU, Memory and Hard disks, Fans, VRM module. 1. System remote management should support browser based Graphical Remote Console; Virtual Power button, Remote boot using USB/CD/DVD Drive and should be capable to offer upgrade of software and patches from a remote client using Media/image/ folder; server power capping and historical reporting; should have support for multifactor authentication. 2. Remote management port should be able to download the firmware from the website directly or from internal system. Server should support automated firmware update. 3. Server should support agent less management using the out-ofband remote management port instead of OS and SNMP port on the OS. This will enable zero downtime updates 4. The server should support features which monitors and records changes in the server hardware and system configuration. It assists in diagnosing problems and delivering rapid resolution when system failures occur. 5. Applications to access the server remotely using popular handheld Page 5 of 8 Server Management (optional) devices based on Android or Apple IOS should be available. 6. Remote console sharing with multiple users simultaneously during pre-OS and OS runtime operation, Console replay Console Replay captures and stores for replay the console video during a server's last major fault or boot sequence. Microsoft Terminal Services Integration, 128 bit SSL encryption and Secure Shell Version 2 support. Should provide support for AES and 3DES on browser. Should provide remote firmware update functionality. Should provide support for Java free graphical remote console. The Systems Management software should provide Rolebased security. Should help provide proactive notification of actual or impending component failure alerts on critical components like CPU, Memory and HDD. Should support automatic event handling that allows configuring policies to notify failures via e-mail, pager, or SMS gateway or automatic execution of scripts. Server should support cloud based management by accessing the servers' configuration information, warranty & sla information, support case details anywhere from the internet Should support scheduled execution of OS commands, batch files, scripts, and command line apps on remote nodes Should be able to perform comprehensive system data collection and enable users to quickly produce detailed inventory reports for managed devices. Should support the reports to be saved in HTML, CSV or XML format. Should help to proactively identify out-of-date BIOS, drivers, and Server Management agents and enable the remote update of system software / firmware components. The Server Management Software should be of the same brand as of Page 6 of 8 the server supplier. 2.2 2.3 20 KVA UPS for 2 hours backup Computer Clients Digital Library for Power Rating(KVA): 20KVA,Power Rating kW :16 Technical Specifications-20KVA(3P/1P) Input : Nominal Voltage 220/380 Vac, 230/400 Vac, 240/415 Vac Voltage Range 208~304 Vac ( 50%~100% load) / 305~477 Vac (100% load) Power Factor > 0.95 (full load) Frequency 50/ 60 Hz Communication Interfaces : SMART Slot x 1, MINI Slot x 1, Parallel Port x 2, RS232 Port x 1, REPO Port x 1, Charger Detection Port x 1 Battery : Battery Voltage 240 Vdc Charge Current: Built-in: 4A Additional charger board (optional): 4A Charge Voltage :Float charge 272 ± 2 Vdc Boost charge 280 Vdc Output : Voltage 220/230/240 Vac Voltage Harmonic Distortion < 3% (linear load) Voltage Regulation ± 2 % Frequency 50/60 Hz ± 0.1Hz Overload Capacity ≤105 %: continuous; 106%~110%: 10 minutes; 111%~125%: 1 minute; 126%~150%: 30 seconds Conformance :Safety & EMC CE, IEC62040-1, IEC620402 Other Features: Emergency Power Off Local and remote Maintenance Bypass Switch Built-in Efficiency :Online Mode 91% ECO Mode 96%, Physical: Dimensions :(Wx Dx H) 250 x 610 x 650 mm Weight 45 Kg Environment: Operating Temperature 0 ~ 40 oC Relative Humidity 5% ~ 95 % (non-condensing) Audible Noise < 60 dBA Warranty 2 years. Operating system: WES09, WES7 and Thin Pro Local clients: Preinstalled Citrix ICA 12.0 (Citrix Online Plugin 12.0), Microsoft RDP 7.0, Microsoft Internet Explorer 7, Windows Media Player 11, Teem Talk Terminal Emulation 7, Remote Graphics Software Receiver 5.4 for VMware Horizon View and Microsoft Terminal Services, Adobe ® Flash Player 10.1. Security features: Configure to use Enhanced Write Filter or Filebased Write Filter, Microsoft Firewall available as download, administrator and user passwords, HP USB Config utility to disable local storage, smart card support, Kensington lock support. Available as download: Universal Print Driver, Management and deployment: Device Manager Agent, Thin State, Host environments: Microsoft Terminal Services, Citrix Desktop, Citrix Presentation Server, Virtual Desktop Infrastructure (Microsoft and VM Ware), blade workstations, web applications, mainframes (using terminal emulation), Processor: Intel Atom 120 Page 7 of 8 Dual Core, Memory: 2GB, DDR3 SO-DIMM, Storage: 0GB or 8GB Flash configurations Graphics: Intel Integrated Graphics Processor Audio: Buzzer only, Realtek ALC261 Audio Codec supports up to 24-bit, 192 KHz samples Communications: 10/100/1000 Ethernet, TCP/IP with DNS and DHCP, Point-to-Point Protocol (PPP), Point-to-Point over Ethernet (PPPoE), Point-to-Point Tunneling Protocol (PPTP), Layer-2 Tunneling Protocol (L2TP), Wake on LAN (WOL), PXE, SNTP, SNMP, and RPL, Ports and connectors: Four (4) USB 2.0 ports (two front, two rear), VGA, one parallel, Four (4) serial, two (2) PS/2, one front audio out, one front audio in, one RJ-45 port, Input devices: Standard keyboard and 2-button optical scroll mouse included (USB or PS/2; varies by region) Power: Worldwide auto-sensing 100-240 VAC, 5060 Hz energy-saving automatic power-down, surge-tolerant, ENERGY STAR®2.0 qualified 65watt power supply supplying 19VDC. Display: 19” LED Flat screen Environmental: ENERGY STAR® qualified. Dimensions (HxWxD): 8.66 x 1.97 x 7.74 in (220 x 50 x 194 mm) without stand; 9 x 1.97 x 7.74 in (228.5 x 50 x 194 mm) with stand, Warranty: Three-year hardware warranty GENERAL INFORMATION a) The Tender conditions and formats of different forms can be seen in the University web site www.jntuk.edu.in b) Tender advertisement and details will be available on JNTUK website from 0210-2014. The concerning advertisement in reputed daily News Papers would also appear on 02-10-2014. The last date for submission of Tender documents is 18-10-2014 upto 3.00 pm. c) Both the Technical bids and Financial bids along with original Demand Drafts of bid processing fee, EMD etc., are to be kept in separate cloth covers and are to be sealed. Every cover should bear the Tenderers complete address, along with the title of the Work/Works. All these covers should be kept in a separate big cover and should reach (by post/person/courier) to the Registrar, JNT University Kakinada, Kakinada- 533 003 on or before 18-10-2014 upto 3.00 pm. A sealed box for dropping the tender covers would be kept in the Registrar’s Office. Nonsubmission of any fee/deposit prescribed will attract the rejection clause. d) Bid opening date : 18-10-2014 at 4.00 pm. e) All the Tenderers should submit both the bids i.e., technical and price bids in separate covers. Otherwise, the tender will not be considered. f) University reserves the right to cancel the Tender at anytime without assigning any reasons whatsoever. g) Contact Phone No’s: 9963993464, 0884-2300874. h) Any correspondence concerning tenders should be made in the name of the Registrar, JNT University Kakinada, Kakinada- 533 003. Page 8 of 8