OSHA Federal Standards October 1, 2014 – September 30, 2015 M FALL PROTECTION – RESIDENTIAL CONSTRUCTION 501(b)(13) 4060 X 1053(b)(1) 1514 M FALL PROTECTION – UNPROTECTED SIDES & EDGES 501(b)(1) 1370 M EYE AND FACE PROTECTION 102(a)(1) 1347 E FALL PROTECTION – TRAINING 503(a)(1) 1219 E HEAD PROTECTION 100(a) 1183 L 451(g)(1) L 453(b)(2)(v) L SCAFFOLDS – FALL PROTECTION 501(b)(10) 780 AERIAL LIFTS – FALL PROTECTION 764 FALL PROTECTION – ROOFING WORK ON LOW-SLOPED ROOFS 711 SAFE ACCESS M SUBPARTS 1926 1926. CFR CFR 2929 PORTABLE LADDERS NOT EXTENDED 3 FEET ABOVE LANDING 1926 Overall MFC MOST FREQUENTLY CITED SERIOUS VIOLATIONS IN CONSTRUCTION 2015 451(e)(1) 638 NUMBER OF SERIOUS VIOLATIONS – FY 2015 2 GENERAL SAFETY & HEALTH [1926.20 – .35] 20(b)(2) 632 29 CFR 1926. EMPLOYEE TRAINING PROGRAMS 21(b)(2) 434 INITIATE AND MAINTAIN ACCIDENT PREVENTION PROGRAMS 20(b)(1) SUBPART C INSPECTIONS BY A COMPETENT PERSON 281 HOUSEKEEPING 25(a) 124 PERSONAL PROTECTIVE EQUIPMENT – EMPLOYER RESPONSIBILITY 28(a) 72 3 NUMBER OF SERIOUS VIOLATIONS – FY 2015 OCCUPATIONAL HEALTH & ENVIRONMENTAL CONTROLS [1926.50 – .66] 62(d)(1)(i) 47 29 CFR 1926. LEAD – BIOLOGICAL MONITORING 62(d)(2)(v)(E) 29 WASHING FACILITIES FOR HARMFUL CONTAMINANTS 51(f)(1) SUBPART D LEAD – DETERMINING EXPOSURE AT OR ABOVE ACTION LEVELS 28 LEAD – CHANGE AREAS PROVIDED PRIOR TO EXPOSURE ASSESSMENT 62(d)(2)(v)(C) 27 LEAD – PROTECTIVE CLOTHING & EQUIPMENT PROVIDED PRIOR TO EXPOSURE ASSESSMENT 62(d)(2)(v)(B) 23 EMERGENCY EYEWASH/SHOWER 50(g) 23 NUMBER OF SERIOUS VIOLATIONS – FY 2015 4 PERSONAL PROTECTIVE & LIFE SAVING EQUIPMENT [1926.95 – .107] 102(a)(1) 1347 29 CFR 1926. HEAD PROTECTION 100(a) 1183 PPE – PROVIDED USED & MAINTAINED 95(a) SUBPART E EYE AND FACE PROTECTION 229 REQUIRED EYE & FACE PROTECTION – ANSI REQUIREMENTS 102(a)(2) 18 FOOT PROTECTION 96 12 5 NUMBER OF SERIOUS VIOLATIONS – FY 2015 FIRE PROTECTION & PREVENTION [1926.150 – .159] 29 CFR 1926. 150(c)(1)(i) 42 EXTINGUISHERS WITH 50FT OF 5 GALLONS OF FLAMMABLE LIQUIDS 150(c)(1)(vi) 23 PROVIDING FIRE EXTINGUISHER NOT RATED LESS THAN 2A FOR EACH FLOOR 150(c)(1)(iv) SUBPART F 2A FIRE EXTINGUISHER PROVIDED PER 3000 SQFT OF BUILDING AREA 22 INSPECTION & MAINTENANCE OF FIRE FIGHTING EQUIPMENT 150(a)(4) 19 PORTABLE FIRE EXTINGUISHERS INSPECTED PERIODICALLY & MAINTAINED 150(c)(1)(viii) 17 6 NUMBER OF SERIOUS VIOLATIONS – FY 2015 SIGNS, SIGNALS & BARRICADES [1926.200 – .203] 200(g)(1) 23 29 CFR 1926. TRAFFIC CONTROL SIGNS/DEVICES 200(g)(2) 22 FLAGGERS - SIGNALING 201(a) SUBPART G TRAFFIC SIGNS AT POINTS OF HAZARD 15 VISIBILITY OF SIGNS AND SYMBOLS 200(a) 5 USE OF CAUTION SIGNS 200(c)(1) 2 7 NUMBER OF SERIOUS VIOLATIONS – FY 2015 MATERIALS HANDLING, STORAGE, USE & DISPOSAL [1926.250 – .252] 252(a) 19 29 CFR 1926. RIGGING EQUIPMENT INSPECTION & REMOVAL FROM SERVICE 251(a)(1) 16 WELDED ALLOY STEEL CHAIN SLING IDENTIFICATION 251(b)(1) SUBPART H EXTERIOR DROP CHUTES 15 MATERIALS STORED TO PREVENT SLIDING FALLING, OR COLLAPSE 251(a)(2)(i) 11 GENERAL RIGGING EQUIPMENT IDENTIFICATION 250(a)(1) 9 8 NUMBER OF SERIOUS VIOLATIONS – FY 2015 TOOLS: HAND & POWER [1926.300 – .307] 300(b)(1) 121 29 CFR 1926. GUARDING OF PORTABLE CIRCULAR SAWS 304(d) 57 SUBPART I TOOLS DESIGNED FOR GUARDS – GUARDS IN PLACE WOODWORKING TOOLS – ANSI REQUIREMENTS 304(h)(1) 35 GUARDING OF CIRCULAR HAND-HELD RIPSAWS 300(b)(2) 35 GUARDING OF ROTATING/MOVING PARTS 304(f) 29 9 NUMBER OF SERIOUS VIOLATIONS – FY 2015 WELDING & CUTTING [1926.350 -.354] 350(a)(9) 26 29 CFR 1926. OXYGEN CYLINDER STORAGE 350(a)(10) 16 USING CABLES NEEDING REPAIR 351(b)(4) SUBPART J CYLINDERS SECURED UPRIGHT 11 REGULATORS AND GAUGES SHALL BE IN PROPER WORKING ORDER 350(h) 5 SECURING OF CYLINDERS WHILE IN USE 350(a)(7) 4 10 NUMBER OF SERIOUS VIOLATIONS – FY 2015 ELECTRICAL [1926.400 – .449] 29 CFR 1926. 404(f)(6) 282 WORN/FRAYED CORDS AND CABLES 416(e)(1) 215 FLEXIBLE CORD STRAIN RELIEF 405(g)(2)(iv) SUBPART K GROUNDING PATH 174 USE OF GFCI OR ASSURED GROUNDING PROGRAM 404(b)(1)(i) 167 EQUIPMENT INSTALLATION AND USE 403(b)(2) 153 11 NUMBER OF SERIOUS VIOLATIONS – FY 2015 SCAFFOLDS [1926.450 – .454] 29 CFR 1926. 451(g)(1) 780 AERIAL LIFTS – FALL PROTECTION 453(b)(2)(v) 764 SUBPART L FALL PROTECTION SAFE ACCESS 451(e)(1) 638 FULL PLANKING 451(b)(1) 573 PROTECTION BY PFAS OR GUARD RAIL SYSTEM 451(g)(1)(vii) 400 12 NUMBER OF SERIOUS VIOLATIONS – FY 2015 FALL PROTECTION [1926.500 – .503] 29 CFR 1926. 501(b)(13) 4060 UNPROTECTED SIDES & EDGES 501(b)(1) 1370 FALL HAZARD TRAINING 503(a)(1) SUBPART M RESIDENTIAL CONSTRUCTION 1219 ROOFING WORK ON LOW-SLOPED ROOFS 501(b)(10) 711 ROOFING WORK ON STEEP ROOFS 501(b)(11) 536 13 NUMBER OF SERIOUS VIOLATIONS – FY 2015 HELICOPTERS, HOISTS, ELEVATORS, AND CONVEYORS [1926.550 – .556] 29 CFR 1926. 552(a)(1) 15 HOISTS & ELEVATORS – ENCLOSURES FOR HOIST TOWERS OUTSIDE OF STRUCTURE 552(c)(1) SUBPART N HOISTS & ELEVATORS – COMPLYING WITH MANUFACTURER’S RECOMMENDATIONS 4 HOISTS & ELEVATORS – MATERIAL HOIST SHALL CONFORM WITH ANSI A10.5-1969 552(b)(8) 2 14 NUMBER OF SERIOUS VIOLATIONS – FY 2015 MOTOR VEHICLES, MECHANIZED EQUIPMENT, & MARINE OPERATIONS [1926.600 – .606] 602(d) 47 29 CFR 1926. MODIFICATIONS THAT AFFECT CAPACITY RATING 602(c)(1)(ii) 40 INDUSTRIAL TRUCKS ANSI B56.1-1969 REQUIREMENTS 602(c)(1)(vi) SUBPART O INDUSTRIAL TRUCK OPERATOR TRAINING 34 SAFE RIDING SPACE ON INDUSTRIAL TRUCKS 602(c)(1)(vii) 19 SAFETY PLATFORM SECURED TO CARRIAGE OR FORKS 602(c)(1)(viii)(A) 17 15 NUMBER OF SERIOUS VIOLATIONS – FY 2015 EXCAVATIONS [1926.650 – .652] 652(a)(1) 512 29 CFR 1926. SAFE EGRESS 651(c)(2) 242 COMPETENT PERSON - INSPECTIONS 651(k)(1) 173 PROTECTION FROM FALLING/ROLLING MATERIALS AND EQUIPMENT 651(j)(2) 159 COMPETENT PERSON - INSPECTION AND EMPLOYEE REMOVAL 651(k)(2) 55 NUMBER OF SERIOUS VIOLATIONS – FY 2015 SUBPART P CAVE-IN PROTECTION CONCRETE & MASONRY CONSTRUCTION [1926.700 – .706] 29 CFR 1926. 701(b) 147 SHORING EQUIPMENT SHALL BE INSPECTED PRIOR TO ERECTION 706(b) 5 MASONRY WALL OVER 8 FEET SHALL BE BRACED 703(b)(1) SUBPART Q REINFORCING STEEL GUARDING 5 SEMICIRCULAR MASONRY SAW GUARDING 703(a)(2) 4 LOCKOUT/TAGOUT OF BULK CEMENT STORAGE FACILITIES 702(i)(1) 4 17 NUMBER OF SERIOUS VIOLATIONS – FY 2015 STEEL ERECTION [1926.750 – .761] 760(a)(1) 118 29 CFR 1926. FALL HAZARD TRAINING 761(b) 23 FALL PROTECTION FOR CONNECTION 760(b)(3) SUBPART R PROTECTION FROM FALL HAZARDS 13 PROTECTION FROM FALL HAZARDS MORE THAN 2 STORIES OR 30 FEET 760(b)(1) 8 UNSECURED DECKING IN CDZ EXCEEDING 3,000 SQFT. 760(c)(3) 7 18 NUMBER OF SERIOUS VIOLATIONS – FY 2015 UNDERGROUND CONSTRUCTION, CAISSONS, COFFERDAMS, AND COMPRESSED AIR [1926.800 – .804] 800(q)(2) 2 29 CFR 1926. INSPECTION OF DRILLING AREA BEFORE DRILLING OPERATIONS STARTS 800(b)(3) 2 EMPLOYEES INSTRUCTED ON RECOGNITION AND AVOIDANCE OF HAZARDS UNDERGROUND 800(g)(5)(ii) SUBPART S CONTROLLING ACCESS TO UNDERGROUND BY UNAUTHORIZED PERSONNEL 1 DESIGNATED PERSON STATION ABOVE GROUND 800(g)(3) 1 5-PERSON RESCUE TEAMS FOR JOBSITES LESS THAN 25 EMPLOYEES 800(d) 1 19 NUMBER OF SERIOUS VIOLATIONS – FY 2015 DEMOLITION [1926.850 – .860] 29 CFR 1926. 850(a) 49 UTILITIES SHUT OFF OR CAPPED BEFORE DEMOLITION OPERATIONS 850(c) 6 SUBPART T ENGINEERING SURVEY PRIOR TO DEMOLITION OPERATIONS SHORING AND BRACING OF WALLS AND FLOORS 851(b) 4 REMOVAL OF STRUCTURAL OR LOAD-SUPPORTING MEMBERS 850(b) 4 OPEN WALLS PROTECTED BY A HEIGHT OF 42 INCHES 850(g) 3 20 NUMBER OF SERIOUS VIOLATIONS – FY 2015 POWER TRANSMISSION AND DISTRIBUTION [1926.950 – .968] 29 CFR 1926. 962(b)(3) 2 NO INDUCED VOLTAGES 960(c)(1)(iii)(B) 2 SUBPART V INSULATION ON THE ENERGIZED PART SUPERVISION AND ANNUAL INSPECTION 950(b)(3) 1 21 NUMBER OF SERIOUS VIOLATIONS – FY 2015 ROLLOVER PROTECTIVE STRUCTURE; OVERHEAD PROTECTION [1926.1000 – .1003] 29 CFR 1926. 1000(B1) 1 SUBPART W ROPS ON EQUIPMENT MANUFACTURED ON OR AFTER SEPT 1, 1972 22 NUMBER OF SERIOUS VIOLATIONS – FY 2015 STAIRWAYS AND LADDERS [1926.1050 – .1060] 29 CFR 1926. 1053(b)(1) 1514 APPROPRIATE USE 1053(b)(4) 364 USING TOP STEP AS A STEP 1053(b)(13) SUBPART X PORTABLE LADDER – 3 FEET ABOVE LANDING SURFACE 276 LADDER & STAIRWAY HAZARD TRAINING 1060(a) 244 STAIRWAY OR LADDER PROVIDED AT BREAK IN ELEVATION ON 19 INCHES 1051(a) 150 23 NUMBER OF SERIOUS VIOLATIONS – FY 2015 TOXIC & HAZARDOUS SUBSTANCES [1926.1100 – .1152] 1101(k)(9)(i) 30 29 CFR 1926. ASBESTOS – EXPOSURE ASSESSMENT BY A COMPETENT PERSON 1101(f)(2)(i) 29 ASBESTOS – EXPOSURE MONITORING 1101(f)(1)(i) SUBPART Z ASBESTOS – TRAINING PROGRAM 18 ASBESTOS – IDENTIFY PRESENCE, LOCATION & QUANTITY OF ACM/PACM 1101(k)(3)(i) 15 CLASS I, II, AND III WORK IN REGULATED AREA 1101(e)(1) 12 24 NUMBER OF SERIOUS VIOLATIONS – FY 2015 CRANES AND DERRICKS IN CONSTRUCTION [1926.1400 – .1442] 1412(f)(1) 15 29 CFR 1926. MONTHLY INSPECTION OF EQUIPMENT 1412(e)(1) 10 MAINTAIN BARRIERS AROUND HAZARD AREA 1424(a)(2)(ii) SUBPART CC EQUIPMENT INSPECTION EVERY 12 MONTHS 9 OPERATION PROCEDURES OF EQUIPMENT 1428(a) 8 SIGN PERSON QUALIFICATIONS 1417(c)(1) 8 25 NUMBER OF SERIOUS VIOLATIONS – FY 2015