Most Frequently Cited Serious Violations

advertisement
FHM TRAINING TOOLS
This training presentation is part of FHM’s
commitment to creating and keeping safe
workplaces.
Be sure to check out all the training programs
that are specific to your industry.
Number of Serious Violations - FY 00
1
Frequently Cited OSHA Violations
Construction
Most Frequently Cited Serious
Violations
Construction – FY00
Standard & Subpart - 1926.
Fall protection - Unprotected sides & edges
501(b)(1) - M
100(a) - E
451(g)(1) - L
1468
Head protection
994
Scaffolds - Fall protection
948
Excavations - Protection of employees
785
21(b)(2) - C
Scaffolds - Safe access
451(e)(1) - L
652(a)(1)- P
451(b)(1) - L
783
Employee training
755
Scaffolds - Platform construction
Fall hazards training program
609
503(a)1)- M
Inspections by competent persons
20(b)(2) - C
1053(b)(1) - X
660
595
Portable ladder 3 feet above landing surface
522
Number of Serious Violations - FY 00
3
Subpart C - General Safety &
Health
(1926.20 - 35)
Employee training programs
21(b)(2)
785
Standard - 1926.
Inspections by competent person
20(b)(2)
595
Initiate and maintain accident prevention programs
20(b)(1)
388
Housekeeping
25(a)
212
Personal protective equipment
28(a)
98
Number of Serious Violations - FY 00
4
Subpart D - Occupational Health &
Environmental Controls
(1926.50 - 66)
Lead - Exposure assessment
Standard - 1926.
62(d)(1)(i)
50(c)
50
First aid training
44
Gases, vapors, fumes, dusts & mists - Employee exposure
36
55(a)
Gases, vapors, fumes, dusts & mists - Controls
29
55(b)
Lead - Interim respiratory protection
62(d)(2)(v)(A)
22
Number of Serious Violations - FY 00
5
Subpart E - Personal Protective &
Life Saving Equipment
(1926.95 - 107)
Head protection required
100(a)
994
Standard - 1926.
Eye and face protection
102(a)(1)
301
PPE - Provided, used and maintained
95(a)
195
Safety nets for falls over 25 feet
105(a)
122
Life jackets/vests
106(a)
27
Number of Serious Violations - FY 00
6
Subpart F - Fire Protection &
Prevention
(1926.150 - 159)
2A fire extinguishers - Building area
33
Standard - 1926.
150(c)(1)(i)
Flammables/combustibles - Approved containers
26
152(a)(1)
Storage of LPG containers
18
153(j)
Fire protection program/equipment
150(a)(1)
15
10B fire extinguisher within 50 ft. of flammable/combustible liquids
150(c)(1)(vi)
15
Number of Serious Violations - FY 00
7
Subpart G - Signs, Signals &
Barricades
(1926.200 - 203)
Flagmen/traffic control
Standard - 1926.
25
201(a )(1)
Traffic signs at points of hazard
24
200(g)(1)
Flagmen - Warning garments
19
201(a )(4)
Number of Serious Violations - FY 00
8
Subpart H - Materials Handling,
Storage, Use & Disposal
(1926.250 - 252)
Rigging equipment inspection & removal from service
Standard - 1926.
251(a )(1)
31
Synthetic web slings - Removal from service
251(e)(8)
22
Exterior drop chutes
252(a )
22
Capacity not marked – Not proof tested
251(a )(4)
8
Number of Serious Violations - FY 00
9
Subpart I - Tools: Hand & Power
(1926.300 - 307)
Woodworking tools - ANSI requirements
304(f)
155
Standard - 1926.
Tools designed for guards - Guards in place
300(b)(1)
72
Guarding of rotating/moving parts
300(b)(2)
54
Circular saw blade not guarded
304(i)(1)
33
Guarding of cup-type grinding wheels
303(c)(3)
19
Number of Serious Violations - FY 00
10
Subpart J - Welding & Cutting
(1926.350 -354)
Cylinders secured upright
99
350(a)(9)
Standard - 1926.
Oxygen cylinder storage
87
350(a)(10)
Valve protection caps
32
350(a)(1)
Fire extinguishing equipment available
23
352(d)
Cables need repair - in use
22
351(b)(4)
Number of Serious Violations - FY 00
11
Subpart K - Electrical
(1926.400 - 449)
Branch circuits - Ground fault protection/
Assured equipment grounding conductor program
404(b)(1)(i)
424
Standard - 1926.
Grounding path
404(f)(6)
240
Ground-fault circuit interrupters
404(b)(1)(ii)
184
Guarding live parts
403(i)(2)(i)
149
Equipment installation and use
403(b)(2)
119
Number of Serious Violations - FY 00
12
Subpart L - Scaffolds
(1926.450 - 454)
Scaffolds above 10 ft. - Fall protection
451(g)(1)
948
Standard - 1926.
Scaffold access
451(e)(1)
783
Scaffold working levels - Planked & decked
451(b)(1)
660
Training for employees using scaffolds
454(a)
510
Body belt worn and lanyard attached to boom
453(b)(2)(v)
470
Number of Serious Violations - FY 00
13
Subpart M - Fall Protection
(1926.500 - 503)
Unprotected sides & edges - Fall protection
1468
501(b)(1)
Fall hazards training program
Standard - 1926.
609
503(a)(1)
Fall protection - Residential construction 6’ or more
552
501(b)(13)
Fall protection - Roofing work on low-slope roofs
367
501(b)(10)
Fall protection - Steep roofs
231
501(b)(11)
Number of Serious Violations - FY 00
14
Subpart N - Cranes, Derricks,
Hoists, Elevators & Conveyors
(1926.550 - 556)
Crawler, locomotive, & truck cranes - ANSI B30.5-1968
47
550(b)(2)
Standard - 1926.
Swing radius at rear of crane barricaded
41
550(a)(9)
Cranes & derricks - Manufacturer’s specifications
31
550(a)(1)
Annual inspection - Competent person
30
550(a)(6)
Daily inspection - Competent person
16
550(a)(5)
Number of Serious Violations - FY 00
15
Subpart O - Motor Vehicles, Mechanized
Equipment, & Marine Operations
(1926.600 - 606)
Industrial trucks - ANSI B56.1-1969
602(c)(1)(vi)
61
Standard - 1926.
Earthmoving/compacting equipment - Reverse signal alarm
602(a)(9)(ii)
58
Lifting/hauling equipment - Use of safety platform
602(c)(1)(viii)(A)
44
Bi-directional machines - Horn
602(a)(9)(i)
35
Vehicles with obstructed rear view - Alarm/observer
601(b)(4)
15
Number of Serious Violations - FY 00
16
Subpart P - Excavations
(1926.650 - 652)
Employee protection in excavations - Protective system use
652(a)(1)
755
Standard - 1926.
Egress from trench excavations
651(c)(2)
351
Inspections by competent person
651(k)(1)
345
Protection from falling/rolling materials/equipment
651(j)(2)
263
Competent person inspection - Employees removed from hazard
651(k)(2)
83
Number of Serious Violations - FY 00
17
Subpart Q - Concrete & Masonry
Construction
(1926.700 - 706)
Reinforcing steel - Guarding
Standard - 1926.
701(b)
256
Masonry walls - Bracing
706(b)
35
Masonry construction - Limited access zone
706(a)(1)
20
Number of Serious Violations - FY 00
18
Subpart R - Steel Erection
(1926.750 - 753)
Tag lines to control loads
Standard - 1926.
751(d)
19
Skeleton steel erection - Tightly planked & substantial floor
750(b)(2)(i)
14
Tiered buildings not adaptable to temporary floors - Safety nets
750(b)(1)(ii)
14
Number of Serious Violations - FY 00
19
Subpart T - Demolition
(1926.850 - 860)
Engineering survey - Prior to operations
47
850(a)
Standard - 1926.
Dropped material - Area protected
9
852(a)
Testing for dangerous chemicals
850(e)
859(g)
850(g)
852(f)
5
Inspections by competent person
4
Wall openings - Protection
3
Chute openings - Toeboard/bumper
2
Number of Serious Violations - FY 00
20
Subpart X - Ladders
(1926.1050 - 1060)
Portable ladders 3 feet above landing surface
522
1053(b)(1)
Standard - 1926.
Stairrails & handrails
310
1052(c)(1)
Stairways/ladders required
159
1051(a)
Training program
1060(a)
143
Minimum clearance between rungs
1053(b)(13)
122
Number of Serious Violations - FY 00
21
Subpart Z - Toxic & Hazardous
Substances
(1926.1100 - 1152)
Asbestos - Monitoring to determine airborne concentrations
28
1101(f)(1)(i)
Standard - 1926.
Asbestos - Class I, II, & III asbestos work in regulated areas
27
1101(e)(1)
Asbestos - Training program
27
1101(k)(9)(i)
Asbestos - Exposure assessment by competent person
25
1101(f)(2)(i)
Asbestos - Protective clothing
25
1101(i)(1)
Asbestos - Identify ACM/PACM* before work
1101(k)(3)(i)
9
*Asbestos-containing material/Presumed asbestos-containing material
Number of Serious Violations - FY 00
22