Malaysian Journal of Civil Engineering Vol (Series) :Page (Year) PLEASE WRITE THE FULL TITLE OF THE PAPER IN CAPITAL First Author 1,*, Second Author2, Third Author3 and Fourth Author1 1 Precast Concrete Research Group (PCRG), Faculty of Civil Engineering, Universiti Teknologi Malaysia, 81310 Johor Bahru, Johor, Malaysia 2 Forensic Unit (Structure), Civil Engineering, Structure and Bridge Section, Public Works Department Malaysia, The Boulevard, Mid Valley City, Lingkaran Syed Putra, 59200 Kuala Lumpur. 3 Faculty of Civil & Environment Engineering, Universiti Malaysia Pahang, Lebuhraya Tun Razak, 26300 Gambang, Kuantan, Pahang. *Corresponding Author: example@utm.my Abstract: Malaysian Journal of Civil Engineering published twice a year by Faculty of Civil Engineering, Universiti Teknologi Malaysia is concerned with knowledge development in various aspects of design, construction and research in Civil Engineering. The Journal was initiated in 1989 making MJCE the longest running journal of civil engineering in Malaysia. The aim of the journal is to provide alternative venue for promoting and disseminating new knowledge and research findings of high scientific standard among engineers, academicians, researchers, policy makers and other relevant professionals. The journal covers all aspect of civil engineering field which include structures, materials, construction management and IT, water supply and resources, hydraulics and hydrology, transportation and highways, geotechnique and soil mechanics, and environmental engineering. Keywords: example1, example2, example 3 1.0 Introduction Articles submitted will be reviewed and accepted on the understanding that they have not been published elsewhere. The length of articles should be between 3,000 and 6,000 words or approximately 7-15 printed pages (final version). The manuscripts should be written in English or Bahasa Melayu. The original manuscript should be typed one sided and double-spaced (12 to 20 pages), using font 12 and with 40 mm margins all round. Authors must submit the soft-copy of the manuscipt in Microsoft-Word format. Submission of review paper is only by invitation. Please refer to notes for guides on how to prepare a manuscript for MJCE. 2 Malaysian Journal of Civil Engineering Vol (Series) :Page (Year) 7 6 pH 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Sam pling point Wet (high flow ) Dry (low flow ) Figure 2: Example of figure for MJCE manuscript Table 3: Concrete properties with different steel fibre volumetric percentage Concrete Cube Compressive Strength (N/mm2) † Concrete Batch Batch 1 (Plain concrete) Batch 2 (Vf = 0.50%) Batch 3 (Vf = 0.75%) Batch 4 (Vf = 1.00%) Batch 5 (Vf = 1.25%) † Cylinder Splitting Tensile Strength (N/mm2) † Flexural Tensile Strength (N/mm2) † Modulus of Elasticity (kN/mm2) 7days 14days 28-days 28-days 7-days 14days 28days 28-days 19.7 25.9 35.1 2.63 5.3 5.5 6.4 16.20* 18.6 23.0 31.9 2.67 5.3 6.3 7.1 28.90 21.3 25.0 32.8 2.66 4.4 6.6 7.3 28.75 24.7 28.3 34.2 2.74 4.9 6.5 7.8 32.30 25.5 30.3 34.6 2.79 5.4 6.9 7.9 33.65 Average of three (3) samples * Strains gauges were not in good working condition resulted in lower Modulus of Elasticity Malaysian Journal of Civil Engineering Vol (Series) :Page (Year)) 𝜏 = 𝑘𝑐 ∙ 𝑓𝑐𝑡 + 𝜇 ∙ 𝜎𝑛 3 (1) REFERENCES Altun F., Haktanir T., and Ari K. (2007). Effects of Steel Fiber Addition on Mechanical Properties of Concrete and RC Beams. Construction and Building Materials. 21 (3), pp. 654-661. British Standard Institution (BSI) (1983). Testing Concrete, Part 121: Method for Determination of Static Modulus of Elasticity in Compression. London, BS 1881. British Standard Institution (BSI) (1997). Structural Use of Concrete, Part 1: Code of Practice for Design and Construction. London, BS 8110. British Standard Institution (BSI) (2009). Testing Hardened Concrete, Part 3: Compressive Strength of Test Specimens. London, BS EN 12390. British Standard Institution (BSI) (2009). Testing Hardened Concrete, Part 5: Flexural Strength of Test Specimens. London, BS EN 12390. British Standard Institution (BSI) (2009). Testing Hardened Concrete, Part 6: Tensile Splitting Strength of Test Specimens. London, BS EN 12390. European Committee for Standardization (2004). Design of Concrete Structures, Part 1-1: General Rules and Rules for Buildings. London, Eurocode 2: BS EN 1992-1-1. Federation Internationale de la Precontrainte (FIP) (1982). FIP Guide to Good Practice - Shear at the Interface of Precast and In-situ Concrete. Wrexham Springs. Girhammar U.A. and Pajari M. (2008). Test and Analysis on Shear Strength of Composite Slabs of Hollow Core Units and Concrete Topping. Construction and Building Materials. 22 (8), pp. 1708-1722. Gohnert M. (2003). Horizontal Shear Transfer Across a Roughened Surface. Cement & Concrete Composites. 25 (3), pp. 379-385. Hibbeler R.C. (2005). Mechanics of Materials. Sixth Edition. Prentice Hall Inc. Ibrahim I.S., Elliott K.S. and Copeland S. (2008). Bending Capacity of Precast Prestressed Hollow Core Slabs With Concrete Topping. Malaysia Journal Civil Engineering. 20 (2), pp. 260-283. Khaloo A.R. and Afshari M. (2005). Flexural Behaviour of Small Steel Fibre Reinforced Concrete Slabs. Cement and Concrete Composites. 27 (1), pp. 141-149. Oh Teck Yee (2009). The Effect of Surface Roughness and Curing Condition on the Ultimate Shear Capacity of Composite Slab. Master Thesis. Universiti Teknologi Malaysia. RILEM TC162-TDF (2000). Test and Design Methods for Steel Fibre Reinforced Concrete: Bending Test. Mater Struct: 33 (January-February), pp. 3-5. RILEM TC162-TDF (2000). Test and Design Methods for Steel Fibre Reinforced Concrete: σ-ε Design Method. Mater Struct: 33 (March), pp. 75-81. 4 Malaysian Journal of Civil Engineering Vol (Series) :Page (Year) Roesler J.R., Lange D.A., Altoubat S.A., Rieder K.A., and Ulreich G.R. (2004). Fracture of Plain and Fibre-Reinforced Concrete Slabs Under Monotonic Loading. Journal of Materials in Civil Engineering. 16 (5), pp. 452-460. Teychenné D.C., Franklin R.E., and Erntroy H.C. (1988). Design of Normal Concrete Mixes. Department of the Environment. HMSO. Wang Z.L., Wu J., and Wang J.G. (2010). Experimental and Numerical Analysis on Effect of Fibre Aspect Ratio on Mechanical Properties of SFRC. Construction and Building Materials. 24 (4), pp. 559-565.