Accuracy and Precision Purpose: To gain an understanding of the relationships that exist between density, mass, and volume while calibrating laboratory glassware. In this experiment, water will be measured and delivered using a buret, a graduated cylinder, a beaker and a flask. Based on the results, the most accurate measuring device will be determined. Accuracy is a measure of how close a data point is to an accepted (true) value. Percent error is a measure of accuracy and is calculated using the following equation: % πΈππππ = |π΄πππππ‘ππ ππππ’π β πΈπ₯ππππππππ‘ππ ππππ’π| π₯ 100% π΄πππππ‘ππ ππππ’π The percent error is often expressed as a positive number, regardless of whether the measured value is larger or smaller than the accepted value. Precision reflects the uncertainty of reading an individual measurement. Procedure Part A: Determining the Accuracy of a 50 mL beaker A1. Weigh a clean, dry 50 mL beaker that has graduation marks on it. Record its mass on your data sheets. A2. Add tap water to the 20 mL mark, using a dropper pipette to get as close to this mark as possible. A3. Weigh the filled beaker. Record this value on your data sheets. A4. Empty and dry the beaker, and then repeat this measurement two more times. A5. Using the density of water at the lab temperature, calculate the volume of water delivered from the graduated cylinder. Part B: Determining the Accuracy of a Graduated Cylinder B1. Obtain a dry 100 mL graduated cylinder. B2. Add tap water to the 20 mL mark, using a dropper pipette to get as close to this mark as possible. B3. Dry your 50 mL beaker from part A and weigh it. Transfer the water from the graduated cylinder to the beaker and weigh the beaker. B4. Repeat steps B2 and B3 two more times. B5. Using the density of water at the lab temperature, calculate the volume of water delivered from the graduated cylinder. Part C: Determining the Accuracy of a Buret C1. Obtain a buret, and fill with tap water using a beaker and funnel. Remember that measurements must always be made at the bottom of the meniscus for aqueous solutions in glass. C2. Obtain a 50 mL beaker. Measure and record its mass. C3. Read and record the initial water level in the buret. Deliver approximately 20 mL of water to the pre-weighed beaker from the buret and read and record the water level in the buret again. C4. Measure the mass of the beaker and water. C5. Repeat steps C3 and C4 two more times. C6. Measure the temperature of your water, and use this measurement and the density table below to determine the density of the water. C7. Use the mass of water delivered and the known density of water to calculate the actual volume of water delivered. Reference Data Name: Lab Partner: Data and Calculations Part A: Accuracy of a Beaker Box 1 Mass of Empty Beaker (g) 2 Mass of Beaker with 20 mL Water (g) 3 Mass of Water (g) Box 2-Box 1 4 Volume of Water according to Beaker (mL)- βExperimental Valueβ 5 Temperature of Water (ºC) 6 Density of Water According to Table (g/mL) 7 Volume of Water based on DensityβAccepted Valueβ ππππ ππππππ = π ππππππ π©ππ π ππππππ = π©ππ π 8 Percent Error % πΈππππ |π΄πππππ‘ππ ππππ’π β πΈπ₯ππππππππ‘ππ ππππ’π| π₯ 100% = π΄πππππ‘ππ ππππ’π |π΅ππ₯ 7 β π΅ππ₯ 4| π₯ 100% % πΈππππ = π΅ππ₯ 7 Trial 1 Trial 2 Trial 3 Part B: Accuracy of a Graduated Cylinder Box 1 Trial 1 Mass of Empty Graduated Cylinder (g) 2 Mass of Graduated Cylinder with 20 mL Water (g) 3 Mass of Water (g) Box 2- Box1 Volume of Water- Experimental Value (according to graduated cylinder) 4 5 Temperature of Water (ºC) 6 Density of Water According to Table (g/mL) 7 Volume of Water based on densityβAccepted Valueβ ππππ ππππππ = π ππππππ π©ππ π ππππππ = π©ππ π Percent Error % πΈππππ |π΄πππππ‘ππ ππππ’π β πΈπ₯ππππππππ‘ππ ππππ’π| π₯ 100% = π΄πππππ‘ππ ππππ’π |π΅ππ₯ 7 β π΅ππ₯ 4| π₯ 100% % πΈππππ = π΅ππ₯ 7 Trial 2 Trial 3 Part C: Accuracy of a Buret Box 1 Initial mass of empty beaker (g) 2 Initial water level in buret (mL) 3 Final water level in buret (mL) 4 Volume of water delivered (mL)βExperimental Valueβ Box 3- Box 2 Final mass of water and beaker (g) 5 Trial 1 6 Mass of water delivered (g) Box 5- Box 1 7 Temperature of water (ºC) 8 Density of water based on table (g/mL) 9 Volume of Water based on densityβAccepted Valueβ ππππ ππππππ = π ππππππ π©ππ π ππππππ = π©ππ π 10 Percent Error % πΈππππ |π΄πππππ‘ππ ππππ’π β πΈπ₯ππππππππ‘ππ ππππ’π| π₯ 100% = π΄πππππ‘ππ ππππ’π % πΈππππ = |π΅ππ₯ 9 β π΅ππ₯ 4| π₯ 100% π΅ππ₯ 9 Trial 2 Trial 3 Analysis Questions 1. Based on your results, which piece of glassware is most accurate in delivering liquids? Which piece of glassware is least accurate? 2. Consider the definition of precision. Do you feel any of the glassware used in lab today were precise? What criteria are you using to make your decision? 3. Determine the most appropriate piece of equipment to use in the following situations: a. A lab procedure calls for 50 mL of an acid b. You are trying to cool down a piece of hot metal and need about 100 mL of room temperature water c. A lab procedure calls for 25 mL of a calcium chloride solution d. You need to know exactly how much acid, place, it took to neutralize 25.0 mL of a sample of base. You will be using the number to make a series of other important calculations. e. A lab procedure calls for a hot water bath created with 40-50 mL of water 4. A student performs a lab to experimentally determine the boiling point of rubbing alcohol. She determines it is 79.4ºC. After doing research, she finds the βacceptedβ value is 82.5ºC. Calculate the percent error for this situation.