Lineage Power - Total Efficiency TM Smart Grid A Telecom / Commercial consumer’s perspective Paul Smith – Technical Marketing Manager, Lineage Power paul.smith@lineagepower.com (214) 923-4274 Lineage Power - Total Efficiency TM Lineage Power • Heritage of engineering excellence and innovation from Bell Labs • Power Plants from 10 Amps to 20,000 Amps • Engineering and installation services. 3 Meter EMC Chamber • US based engineering, design, qualification, training, and support • Telecom Power Pioneers • Data Center DC Power Training & Certification Facility 1869 1984 1996 2001 2008 Lineage Power - Total Efficiency TM More than just High Efficiency Rectifiers A Holistic approach Total Efficiency TM Active Rectifier Management Renewable Energy Sources ECO Priority Source TM Minimize AC Losses Smart Grid Demand Response 480V vs 240V End to End < Efficiency > Minimize DC Losses Architectural Choices Cost of Power TM ROI Calculator LINEAGE POWER Minimize Utility Bills Lineage Power - Total Efficiency TM Losses • Typical AC installations engineered to trade copper cost against losses - 3% Voltage drop in the ac loop - Gives 3% power loss with 3Ø 480Vac rectifiers, 5.9% loss with 1Ø 240Vac • DC Losses from engineered cable resistance, trading cable cost for loss • Centralized Architecture • - Rectifier to load – 3.9V drop in cable and distribution - Possible 7.4% Power loss Lineage Hybrid Architecture reduces the DC losses by 60% 270KW Example Centralized Architecture 5,000A Load Current Engineered voltage drop – Up to 3.9V 3.9V x 5,000A = 19.5kW losses = $17,082 LOST / yr @10c/KWh Lost Energy is heat – Additional HVAC cost ~ $5,000 / yr © 2009 Lineage Power 270KW Example Hybrid Architecture DC Distribution (VI) losses reduced to loop of <1.0V from 3.9V Losses now 1.0V x 5,000A = 5.0KW SAVINGS: 19.5KW -5.0KW = 14.5KW = $12,702 / yr @10c/KWh HVAC Savings: Approximately $4,000 Total Savings: $16,702 4 Lineage Power - Total Efficiency TM High Efficiency Rectifiers • New Generation “High Efficiency” SMR Rectifier Efficiency @ Nominal Vin, 25C 98.0% • 95-97% Efficient 96.0% • 2nd Generation SMR • 91-93% Efficient 94.0% Efficiency (%) 92.0% 200A Ferro 90.0% 1Ph HE 595LTA 88.0% • Typical 200A Ferro Resonant • 84-89% Efficient CP2725 NE050AC48 86.0% QS865 84.0% 82.0% 80.0% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% • Efficiency improves at higher utilization • Additional benefits from improved power factor and Total Harmonic Distortion. • Utility Service Size implications • Generator sizing and upgrade avoidance opportunities • Paybacks possible in 1-2 years Load (%) © 2009 Lineage Power 5 Lineage Power - Total Efficiency TM Active Rectifier Management TM ARMTM – Place Rectifiers in Stand-by mode to improve operating efficiency of remaining rectifiers Rectifier Efficiency @ Nominal Vin, 25C System Controllers 98.0% A/B Plant Operation 96.0% ARM Operation 94.0% Improving System Efficiency from 40% to 96% Efficiency (%) 92.0% 90.0% 88.0% 86.0% 84.0% 82.0% Lineage 200A Lineage 400A RHM400 RHM200 RL400 ECS TE Series 80.0% 0% 10% 20% 30% 40% 50% 60% 70% 80% Load (%) ARMTM – Rectifiers in Stand-by mode instantly available for load increases 90% 100% Lineage Power - Total Efficiency TM Eco Priority Source™ • Prioritizes clean and green energy sources before generators or the utility grid via Lineage controller/rectifier – UL1472 compliant with 30% leverage via Federal and State tax incentives Lineage Power - Total Efficiency TM Eco Source Control • Lineage Controller Technology – the heart of an ECO efficient Power System – Prioritizes clean / green energy sources before generators / utility grid – Manages battery charging and discharge cycles (vs ECO source availability) – Optimizes use of ECO Sources – Minimizes Utility Grid Costs (time and rate per Smart Grid Response) – Minimizes fossil fuel usage and costs Lineage Power - Total Efficiency TM Smart Grid Demand Response • Disconnect from utility grid during peak demand periods – Automated via utility communications protocol – Dynamic based on lowest cost of power – Scheduled based on peak load hours • Use Battery and / or back up generator already provisioned • Benefits – Take advantage of lower utility rates – Avoid peak rate utility charges – Contribute to Power Grid Stability Lineage Power - Total Efficiency TM Smart Grid Demand Response • • • • Telecom already uses Priority Loads for back up time optimization Controller Technology already present and operational Intelligent, standards based communication interfaces Initial implementation with major telecom service provider – Manual or email notification from utility (Automation coming soon with OpenADR) – Remote, secure Ethernet access to: • Shed non critical load(s) • Turn off rectifier(s) • Initiate controlled battery discharge • Start and run generator(s) Lineage Power - Total Efficiency TM Smart Grid Demand Response • Initial implementation with major telecom service provider – Manual or email notification from utility (Automation coming soon with openADR) – Remote, secure Ethernet access to: • • • • • Restore non critical load(s) Turn on rectifier(s) Terminate controlled battery discharge Stop generator(s) Control battery recharge timing Lineage Power - Total Efficiency TM Smart Grid Demand Response • Automated load restoration considerations – Area wide power restoration • Phased restoration • Site by site • Partial load at multiple sites – Lineage Galaxy Manager • Area or regional central monitoring and control • Utility communications – openADR – Automation of existing Power Plant features Lineage Power - Total Efficiency TM Total Efficiency - Green Network Power HA – addresses restive losses TETM Rectifier efficiency improvements ARMTM Improving the efficiency of lightly loaded plants Cost of Power Calculator – compute real energy savings • Backward compatible for efficiency upgrades to existing plants • Combines Active Rectifier Management with Hybrid Architecture to put all your facilities at the forefront for energy efficiency. • • • • For more information contact Paul.Smith@lineagepower.com / (214)923-4274