JNTUK bid document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY KAKINADA UNIVERSITY COLLEGE OF ENGINEERING - VIZIANAGARAM Via Cantonment, Dwarapudi (Post) Vizianagaram -535 003 Phone:08922-277911 Fax 08922-277488 TENDER NOTICE Tender Notice No. JNTUK-VZM/Campus wide networking, Lab Equipment & Furniture /2014/3, Dt:04-07-2014 Sealed Tenders are invited from reputed Dealers/ Suppliers for the supply of the listed items. The detailed specifications, terms & conditions for the items can be obtained in respect of items from the undersigned from 05/07/2014 between 11.00 am to 5.00 pm on payment of . 500/- (Non- Refundable) in the form of Demand Draft payable at Vizianagaram in favor of Principal, JNTUK, University College of Engineering, Vizianagaram drawn from any nationalized bank not earlier than date of this notification. The sealed tenders should reach the undersigned on or before 2.00 pm on 18/07/2014. The College Authorities reserve the right to accept or reject any or all bids without assigning any reason whatsoever. PRINCIPAL 1 JNTUK bid document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY KAKINADA UNIVERSITY COLLEGE OF ENGINEERING - VIZIANAGARAM Via: Cantonment, Dwarapudi (Vill & Post), Vizianagaram - 535 003. Phone:08922-277911 Fax 08922-277488 Tender Notice No. JNTUK-VZM/Campus wide networking, Lab Equipment & Furniture /2014/3, Dt:04-07-2014 TENDER SCHEDULE GENERAL CONDITIONS: 1. Please quote your lowest rates for each item described. The quotation should reach this office on or before 18/07/2014 by 14:00 hrs. Sealed covers should be submitted for the items super scribing as “Tender No.”, “Date of opening:”, “Item Number(s)”. The sealed covers should be sent by the Registered Post or to be dropped in the sealed box provided in the office of the Principal. The tender will be opened on 18/07/2014 at 14:30 hrs by the undersigned/his nominee in the presence of the committee members and available tenderers or their representatives. 2. E.M.D: The tender documents should be submitted along with earnest money deposit .5,000/- in the form of Demand Draft in favor of “The Principal, JNTUK, University College of Engineering, Vizianagaram” to be payable at State Bank of Hyderabad, LTB Road branch, Vizianagaram. The Demand Draft pertaining to E.M.D. of unsuccessful party will be returned. 3. PRICES (in Indian Rupees): The price should be F.O.R. destination inclusive of taxes, packing & forwarding charges, freight and delivery charges. Items on rate contract, if any together with the terms and conditions may please be furnished. 4. PAYMENT: 100% payment will be made within a reasonable time only after the receipt of all items in good condition and installation as per given specifications and after testing for satisfactory working and on receipt of the company’s invoice with all Supporting vouchers such as copy of A.P. Sales Tax or VAT Registration certificate etc. No advance will be paid in any case either in part or in full. 5. ACCEPTANCE: It is not binding on the university/ institution to accept the lowest of the tenders. The university/ institution reserves the right to place orders for individual items with different tenderers. 6. SPECIFICATIONS: Full specifications along with the description and make should be mentioned in the tender. 7. Warranty/Guaranty: tenderer. 8. DELIVERY: WEEKS. Warranty/Guaranty period should be mentioned by the The period of delivery at destination from date of placing orders is FOUR 2 JNTUK bid document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram 9. VALIDITY: The quotations should be valid for at least 90 days. 10. The Institution reserves the right to cancel the tender without assigning any reason. 11. Those who purchased tender schedule officially by paying . 500/- in the form of Demand Draft drawn in favor of Principal, JNTUK, University College of Engineering, payable at Vizianagaram are only eligible to Participate in the tender. Those who have downloaded the tender schedule from the JNTUK website (www.jntuk.edu.in) should submit a separate DD for .500/- along with the quotation. 12. This Institution being Government educational institution is exempted from payment of Central/State Excise Duty. 13. Since the college is Government institution whatever conditions are applicable to any Government institute shall be applicable even if not specified. 14. Any tender that is received after due date will not be accepted. The college is not responsible for any postal delay. 15. List of Major Customers should be provided. PRINCIPAL Encl: Items with Description 3 JNTUK bid document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Tender Notice No.JNTUK UCEV/Campus wide Networking,Lab Equipment&Furniture/2014-15/3,Date: 05-07-2014 Item no: 1 (Dept.of EEE) 125 KVA Generator 4 JNTUK bid document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY KAKINADA UNIVERSITY COLLEGE OF ENGINEERING - VIZIANAGARAM Via: Cantonment, Dwarapudi (Vill & Post), Vizianagaram - 535 003. Phone:08922-277388 Fax 08922-277488 125 KVA Generator Specifications for Tender Release 100 KW / 125 KVA SILENT Diesel Generating Set with CPCB-II approved acoustic enclosure comprising of: “Cummins” Radiator Cooled, Diesel engine developing 154 BHP at 1500 RPM, complete with standard accessories. Coupled to “Stamford” Alternator rated at 100 KW / 125 KVA at 415 Volts 3 Phase, 0.8 PF, mounted on Channel Iron Base Frame complete with Fuel Tank of 200 Litres capacity with Standard-Manual Control Panel and Battery & Leads. 5 JNTUK bid document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Tender Notice No.JNTUK UCEV/Campus wide Networking,Lab Equipment&Furniture/2014-15/3,Date: 05-07-2014 Item no: 2 Campus Wide Network 6 JNTUK bid document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY KAKINADA UNIVERSITY COLLEGE OF ENGINEERING - VIZIANAGARAM Via: Cantonment, Dwarapudi (Vill & Post), Vizianagaram - 535 003. Phone:08922-277388 Fax 08922-277488 Open Competitive Bid (OCB) For Providing Campus Networking & Local Area Network at JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY KAKINADA VIZIANAGARAM CAMPUS Via Vizianagaram Contonment, Dwarapudi Village Branch Office Vizianagaram Dist – 535 003. 7 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Proprietary & Confidential No part of this document can be reproduced in any form or by any means, disclosed or distributed to any person without the prior consent of JNTUK except to the extent required for submitting bid and no more. Page 8 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Section A Tender call notice. JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY KAKINADA VIZIANAGARAM CAMPUS Via Vizianagaram Cantonment, Dwarapudi Village Branch Office Vizianagaram Dist – 535 003. ----------------------------------------------------------------------------------------------------------- Tender call for Providing Campus Network & Local Area Network at University College of Engineering, Vizianagaram Campus, Vizianagaram. Time schedule of various tender related events. Bid calling date Bid closing date/time Bid opening date/time Bid Document Fee JNTUK Contact person JNTUK Reference No. __/__/____ __/__/____, 03:00 PM __/__/____, 03:30 PM __________________ Introduction: The JNTU, University Engineering College @ Vizianagaram has been established during Sep, 2007 with five Branches Viz., EEE, ECE, CSE, ME, and IT as a constituent college of erstwhile JNTU, Hyderabad. Infrastructure development works Phase I was sanctioned by Govt. to a tune of 28.10 Crores and commenced the construction work in March, 2008 at Dwarapudi, Vizianagaram with an Academic Block, Boys’ Hostel and Girls Hostel. In the year 2008 (20.08.2008) JNTU Kakinada has been established as a separate University with this campus as constituent college and shifted to own campus at Dwarapudi, Vizianagaram during June,2009. Page 9 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram A. The solution, service or material required: A.1. Supply, installation and commissioning of following equipment: Active Components S.No. Part Code Description UOM Qty 1 Layer 3 12 Port Gigabit Ethernet SFP Switch with IP Base As per Detailed Specifications Listed under Section D1.1 No 1 1a 8 x 5 x NBD Hardware replacement warranty for 3 Years Directly provided by the principal manufacturer (for 3 Years Qty Multiplied by 3) No 3 1b Single Mode LX/LH Fiber SFP Transceiver Module As per Detailed Specifications Listed under Section D1.6 No 8 1c 1000 Base T - Gigabit SFP Module As per Detailed Specifications Listed under Section D1.7 No 2 2 Layer 2 Fully Managed Switch with 24 10/100 Mbps Ports and 2 SFP/T Uplinks As per Detailed Specifications Listed under Section D1.2 No 5 2a 8 x 5 x NBD Hardware Replacement warranty for 24 Port 10/100 + 2 T/SFP LAN Lite Image Switch for 3 years Directly provided by the principal manufacturer (for 3 Years Qty Multiplied by 3) No 15 2b Single Mode LX/LH Fiber SFP Transceiver Module As per Detailed Specifications Listed under Section D1.6 No 11 Unified Threat Mitigation Appliance Firewall for 1000 Users with 3 Year Subscription As per Detailed Specifications Listed under Section D1.8 No 1 Core Switch Access Switches UTM Fire Wall 3 Wireless LAN Components - Controller Page 10 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram 4 Wireless LAN Controller Supporting 50 Access Points, Video Streaming, High Availability, IPv6, Voice, Wireless Mesh technology and Mobile Security as per detailed specifications listed under Section D1.4 No 1 4a 8 x 5 x NBD Hardware Replacement Warranty for Wireless LAN Controller for 3 years Directly provided by the principal manufacturer. (for 3 Years Qty Multiplied by 3) No 3 4b Single Mode LX/LH Fiber Transceiver Module As per the detailed specifications listed under Section D1.6 No 8 5 Wireless Access Point 802.11n Compliance, 3 x 3 MIMO, 3 Spatial Streams, Internal Antennae, N Registration Domain as per detailed specifications listed under Section D1.5 No 30 5a 8 x 5 x NBD Hardware Replacement Warranty for Wireless Access Point for 3 years Directly provided by the principal manufacturer. (for 3 Years Qty Multiplied by 3) No 90 6 Power Injector Supporting the above mentioned Access Point and of the same make No 8 7 Layer 2 Managed Switch with 24 10/100 Mbps Ports out of which 8 are PoE and 2 Dual Purpose Ports as per the detailed Specifications listed under Section D1.3 No 10 7a 8 x 5 x NBD Hardware Replacement Warranty for 24 Port 10/100 + 2 10/100/1000 Mbps Managed Switch for 3 years Directly provided by the Principal Manufacturer for the above Layer 2 Switch (for 3Years Qty Multiplied by3) No 30 Description UOM Qty Wireless LAN Components - Access Points Passive Components S.No. Make & Part Code Copper Page 11 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram 1 Cat 6 UTP Cable (Roll of 305 Mtrs) as per the detailed specifications indicated under section D2.5 Box 80 2 Cat 6 Information Outlets - as per the detailed specifications indicated under section D2.6 No 388 3 Cat 6 24 Port Jack Panels – Loaded - as per the detailed specifications indicated under section D2.7 No 19 4 Single / Dual Face Plates No 388 5 Cat 6 7ft Patch Cords - User End - as per the detailed specifications indicated under section D2.8 & D2.9 No 388 6 Cat 6 7ft Patch Cords - Switch End as per the detailed specifications indicated under section D2.8 & D2.9 No 442 1 6 Core Outdoor Optical fiber cable Single Mode as per the detailed specifications indicated under section D2.1 Mtr 7000 2 12 Port LIU (Shelf, 600G2, 1U, Fixed) as per the detailed specifications indicated under section D2.2 No 13 3 600G2 Panel, Accepts 12 Duplex SC Adapters No 13 4 SC Duplex Adapter, SM No 156 5 RoloSplice Kit E/W 2x Fusion Splice Tray for 1U Shelf No 13 6 SC Pigtails 1 Mtr - Single mode as per the detailed specifications indicated under section D2.3 No 156 7 SC-LC Fiber Optic Patch cord 3 Mtr as per the detailed specifications indicated under section D2.4 No 48 Fiber Components Installation & Integration Components Page 12 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram 1 1" Casing & Capping Mtr 4500 2 2" Casing & Capping Mtr 4500 3 1" Flexible Pipe Mtr 325 4 2" Flexible Pipe Mtr 325 5 15U Wall Mountable Rack with standard accessories No 15 6 42 U Closed Rack with standard accessories No 2 7 1" HDPE Pipe with accessories Mtr 6100 8 1" Class B GI Pipe with accessories Mtr 900 9 150X50 MM Industrial Duct Mtr 100 UOM Qty Installation & Integration Services S.No. Part Code 1 Labor Laying of Cat 6 UTP Cable (Roll of 305 Mtrs) Mtr 24400 2 Labor Termination of the Cat 6 Information Outlets No 388 3 Labor Termination of the Cat 6 24 Port Jack Panels – Loaded No 19 4 Labor Fixing of the Single / Dual Face Plates No 388 5 Labor Cat 6 7ft Patch Cords - User End No 388 6 Labor Cat 6 7ft Patch Cords - Switch End No 442 7 Labor Installation of the 1" Casing & Capping Mtr 4500 8 Labor Installation of the 2" Casing & Capping Mtr 4500 9 Labor Installation of the 1" Flexible Pipe Mtr 325 10 Labor Installation of the 2" Flexible Pipe Mtr 325 Labor Installation of the 15U Wall Mountable Rack with standard accessories No 15 Labor Installation of the 42 U Closed Rack with standard accessories No 2 1 Labor Laying of 6 Core Outdoor Optical fiber cable in the HDPE/GI Pipe Mtr 7000 2 Labor Fixing of the 12 Port LIU (Shelf, 600G2, 1U, Fixed) No 13 11 12 Description Page 13 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram 3 Labor Fixing of the 600G2 Panel, Accepts 12 Duplex SC Adapters 4 Labor Fixing of the SC Duplex Adapter, SM Nos 156 Labor RoloSplice Kit E/W 2x Fusion Splice Tray for 1U Shelf Nos 13 6 Labor Splicing / Termination of the SC Pigtails 1 Mtr Single mode No 156 7 Labor SC-LC Fiber Optic Patch cord 3 Mtr No 48 8 Labor Laying of the 1" HDPE Pipe with accessories Mtr 6100 9 Labor Laying of the 1" GI Pipe with accessories Mtr 900 10 Labor Installation of the 150X50 MM Industrial Duct Mtr 100 11 Labor Digging & Refilling of the Hard Rocky Soil Mtr 6100 12 Labor Digging & Refilling of the Road Mtr 500 5 Nos 13 A.2. Scope of incidental services: 1. Furnishing of a detailed operations and maintenance manual for each appropriate unit of the supplied goods. 2. Warranty period services for Three years for Active components and for others One year. A.3. Maintenance : Bidder should indicate Annual maintenance cost for the indicated years after expiry of warranty period. A.4. Delivery and Installation period Bidder shall deliver the goods/services within Eight weeks and install and commission the same with in Twelve weeks from the date of contract signing. Page 14 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Section B B.1 Pre-Qualification criteria: S.No Pre-Qualification Criteria Document Required 1 The Bidder must have been in the business of providing Networking Certificate of Incorporation / Firm Infrastructure facilities for a minimum Registration Certificate to be enclosed period of 5 years. 2 An Undertaking from the bidder on their letter head along with the Blank The Bidder bidding for part of the tender Un-priced Format of the Quoted will be rejected. components without pricing ALONG WITH PART NOS as a proof. 3 The Bidder should be an ISO 9001:2008 Copy of the ISO 9001:2008 Certificate Certified Company for Networking. 4 A Proof to this effect should be enclosed in the form of Balance sheets The bidder should have a minimum and IT Clearance Certificates/Statutory Annual turnover of Rs. 6 Crores each year Auditor's Certificate Stating that the for the past 3 years (2011-12, 2012-13, Annual Sales Turnover for the Last 3 2013-14). years of 2010-11, 2011-12, 2012-13 along with certified Balance Sheets. 5 The Bidder should have an minimum Statutory Auditor's Certificate turnover of Rs. 3 Crores per annum for indicating the turnover pertaining to the past 3 years (2011-12, 2012-13, 2013Networking Business. 14) pertaining to networking domain. 6 The bidder should be an Authorized Integrator / Business Partner / Reseller of the Brand that is proposed for the supplies for a minimum period of 5 years in Andhra Pradesh as on bid calling date. A Letter from the OEM indicating Status of the Bidder who is an Authorized Integrator / Business Partner / Reseller for the past 5 years. 7 All the Active Network Components proposed should be from a single Manufacturer only except for UTM Appliance and the past experience of the bidders should be for the same make of network actives which the bidder is An Undertaking from the bidder on their letter head with the blank Un priced format of the Products ALONG WITH PART NOS Quoted. Page 15 of 98 Criteria Met Yes/No JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram quoting against this tender. 8 The Original Equipment Manufacturer of A copy of the ISO Certificates of the Active Components should be an ISO 9001 OEMs of the Products Quoted. & ISO 14001 Certified. 9 In addition to Bidders support, Service Support should be available directly from the Principals. Bidder should provide The Service Contract Number from the OEM to the Purchaser. Quoted OEM Products should have spares depot in Andhra Pradesh or should maintain adequate spares at the site as indicated below.. 9a If the Spares Depot is not available in the State of Andhra Pradesh for the For Core switches: A Complete chassis OEM an undertaking from the OEM and with all active cards / modules of the along with the Bidder indicating their same make and model. willingness to provide the Working Spares at Site. 9b. If the Spares Depot is not available in the State of Andhra Pradesh for the Access switches: Maintain 10% of OEM an undertaking from the OEM Switches for Access Connectivity of the along with the Bidder indicating their same make and model. willingness to provide the Working Spares at Site. 10 The Active Components Proposed should be supported by the Principal An undertaking from the OEM about Manufacturer for Technical Assistance on their TAC should be provided. 24 x 7 bases thru a Technical Assistance Center (TAC). 11 The Bidder should submit the Manufacturers authorization for the proposed Product on OEM’s letter head to participate for this tender mentioning the bid reference. 12 The Active components proposed should A Letter from the OEM / industry have at least 30% market share in specialists like IDC. A letter from OEM indicating the clear Addresses of their Spares depots along with an undertaking from the Bidder that he will provide the Service Contract Number along with the Products at the time of product delivery. Direct Authorization Letters from the OEMs indicating the Bid Reference to participate in this tender should be provided. Page 16 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Switching & Routing in India. 13 The products quoted should not be A Letter from the OEM indicating their declared End of Life at the time of delivery uninterrupted support for the product and OEM should support the products for the next 5 years. quoted for at least 5 years. 14 A letter of undertaking from the Bidder The Passive Components proposed Should with Blank Un-priced List of be from the Single Manufacturer for both components ALONG WITH PART NOS indicating the Manufacturer of the Fiber and Copper Components. Product. 15 The Passive installation should be certified for ‘Extended Product and Application An undertaking from the OEM on their warranty’ for a minimum period of 20 willingness to certify the product years from the date of Installation by the supplied and Installed by the Bidder. OEM. 16 The bidder must have a full-fledged support centre in Andhra Pradesh to Details of the Bidder's support centers support the installation & should have to be provided in the prescribed qualified engineers to attend to the format. support as & when required by UCEJNTUK Vizianagaram within 24 hours. 16a Copy of the Certificates of bidder's The Bidder should have at least 10 OEM Employees along with an undertaking certified engineers for Active Components that the certified engineers are proposed. (Certificates to be attached permanent employees of the bidder's along with the Technical Bid). organization. 16b Copy of the Certificates of bidder's Should have minimum 10 OEM Certified Employees along with an undertaking cabling installation Personnel. (Certificates that the certified engineers are permanent employees of the bidder's to be submitted). organization. Page 17 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram 17 The Bidder should have installed at least 3 campus networks in educational institutions with at least 500 copper Nodes and about 5 Kilo Meters of Fiber Optic Cabling for backbone as a single order & should have been in the business of providing Turnkey Solutions for Campus Networking for the last 5 years. Documentary Evidence should be provided in the form of Installation Reports/Performance Certificates / Purchase Orders. Note: Relevant documents in support of above should be furnished Page 18 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Section C C1. Statement of important limits/values related to bid Item Earnest Money Deposit (EMD) Bid Validity Period EMD validity Period Maintenance Period Description Rs. _____ lakhs 60 days from the date of opening of bid 45 days beyond bid validity period 3 years for Active network components and one year for Structured Cabling Components. Warranty Period Active Network Components - 3 Years Passive Network Components - 1 year for Cabling labour & 20 years for manufacturing Defects. Variation in quantities +/- 20% Period for signing the Order Within 7 days from date of receipt of notification of award Acceptance Up time % 97% calculated over 3 months period Payment terms On delivery 90% of the Product Value On Installation & Acceptance 10% of Product Value & 100% of Installation Value LD for late deliveries 0.5% of the late delivered goods per week or part there of. Maximum LD for late deliveries 10% of value of late delivered goods. Penalty for failure to maintain For every 1% reduction in uptime from 97%, penalty will be 10% of during warranty or AMC AMC amount. For this purpose AMC will be assumed as 1.50% of PO value during warranty period. After warranty period AMC will be 1/4th of AMC indicated by bidder. Conditional bids Not acceptable and liable for rejection Options for the required If the bidder wants to give option, he may submit it as separate bids along with separate EMD. This will be treated as separate bid equipment for evaluation. Page 19 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Section D D- Technical specification: (The Technical compliance Statements need to be duly filled against each line item and should be attached along with the Technical Bid duly signed and stamped failing which the tender is liable to be rejected) D1 - Active Components D1.1 Specifications for Core Switch Layer 3 Switch with 12 Small form-factor pluggable (SFP) transceiver-based Gigabit Ethernet ports and Standard Multilayer Image with Full Layer 3 Functionality Make & Model : Compliance Yes/No Specification Stackable switch with minimum 12Nos SFP ports and an uplink slot. The uplink slots should support either 4 x 1Gig or 2 x 10Gig ports or a combination Support for Redundant Power supply Minimum of 64 Gbps Forwarding bandwidth Minimum forwarding rate of 35.7 Mpps Support for up to 10,000 MAC addresses, up to 10,000 unicast routes Should support Centralized VLAN Management. VLAN config changes should be automatically communicated to all the other switches in the network Support stacking with up to 64Gbps throughput Should support the ability to aggregate all the power supplies available in the stack and allow the power supplies in the stack to be shared as a common resource among all the switches Should support dynamic VLANs and dynamic trunk configuration across all switches Should support STP, Per-VLAN STP, STP PortFast Support for Unidirectional Link Detection Protocol (UDLD) to detect unidirectional links caused by incorrect fiber-optic wiring or port faults and disable on fiber-optic interfaces Should be able to discover the neighboring device of the same vendor giving the details about the platform, IP Address, Link connected through etc, Basic IP unicast routing protocols (static, RIPv1, and RIPv2) Page 20 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Support for IPv6 unicast routing capability (static, RIP, and OSPF protocols) to forward IPv6 traffic through configured interfaces Support for OSPF, Policy-Based Routing (PBR) Support for Protocol Independent Multicast (PIM) - PIM-SM, PIM-DM, PIM sparse-dense mode. Support for VRF-Lite IGMP snooping v1, v2 and v3 Support for 8 egress queues per port Compliance Yes/No Specification Granular Rate Limiting function to guarantee bandwidth in increments as low as 8 kbps. Rate limiting support based on source and destination IP address, source and destination MAC address, Layer 4 TCP and UDP information, or any combination of these fields Support for Automatic Quality of Service for easy configuration of QoS features for critical applications. IEEE 802.1x to allow dynamic, port-based security, providing user authentication. VLAN ACLs (VACLs) on all VLANs to prevent unauthorized data flows from being bridged within VLANs. Port-based ACLs (PACLs) for Layer 2 interfaces to allow application of security policies on individual switch ports. Standard and Extended IP security router ACLs (RACLs) to define security policies on routed interfaces for control- and data-plane traffic. RADIUS authentication to enable centralized control of the switch and restrict unauthorized users from altering the configuration. Should support DHCP snooping, DHCP Option 82, Dynamic ARP Inspection (DAI) Multilevel security on console access to prevent unauthorized users from altering the switch configuration. Page 21 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Should support a mechanism to shut down Spanning Tree Protocol PortFast-enabled interfaces when BPDUs are received to avoid accidental topology loops. Should support a mechanism to prevent edge devices not in the network administrator's control from becoming Spanning Tree Protocol root nodes. Should support a mechanism to prevent a malicious user from spoofing or taking over another user’s IP address by creating a binding table between client’s IP and MAC address, port, and VLAN Should support MAC layer encryption over links between switch to endpoint devices such as a PC Support for switch to switch uplinks encryption. Support for NetFlow or equivalent for traffic analysis. Should support the following classifiers · Source and destination Mac Addresses · Source and destination IPv4 or IPv6 addresses · Source and destination TCP/User Datagram Protocol (UDP) ports · Type of service (ToS) Compliance Yes/No Specification · DSCP · Packet and byte counts · Flow timestamps · Input and output interface numbers · TCP flags and encapsulated protocol (TCP/UDP) and individual TCP Flags · Sections of packet for deep packet inspection · All fields in IPv4 Header including IP-ID, TTL and others Page 22 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram · All fields in IPv6 Header including Flow Label, Option Header and others · Routing information (next-hop address, source autonomous system (AS) number, destination AS number, source prefix mask, destination prefix mask, BGP Next Hop, BGP Policy Accounting traffic index) Support for Unicast Reverse Path Forwarding (RPF) to mitigate problems caused by the introduction of malformed or forged (spoofed) IP source addresses into a network by discarding IP packets that lack a verifiable IP source address Remote port mirroring to remotely monitor ports in a Layer 2 switch network from any other switch in the same network. Switch should provide the ability to monitor events and take corrective, or any desired action when the monitored events occur or when a threshold is reached Should support a mechanism to analyze IP service levels for IP applications and services by using active traffic monitoring (the generation of traffic in a continuous, reliable, and predictable manner) for measuring network performance information in real time. Should provide a mechanism to check the health of hardware components and verify proper operation of the system data and control plane at run time and boot time Remote Monitoring (RMON) software agent to support four RMON groups (history, statistics, alarms, and events) for enhanced traffic management, monitoring, and analysis. SNMPv1, SNMPv2c, and SNMPv3 Page 23 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram D1.2. – Specifications for Access Switches Layer 2 Switch with 24 Ethernet 10/100 ports 2 Nos. of Dual Purpose 10/100/1000 or SFP Ports. Make & Model: Compliance Yes/No Specification Switch should have minimum 24nos of Ethernet 10/100 and 2nos of dual-purpose GigE ports. Should have Minimum forwarding rate of 6.5 Mpps Support for up to 8,000 MAC addresses Should support STP, Per-VLAN STP, STP PortFast Should be able to discover the neighboring device of the same vendor giving the details about the platform, IP Address, Link connected through etc, Should support IGMP snooping v1, v2 and v3 Should Support RADIUS authentication to enable centralized control of the switch and restrict unauthorized users from altering the configuration. Support for Layer 2 traceroute to identify the physical path that a packet takes from source to destination Should have Multilevel security on console access to prevent unauthorized users from altering the switch configuration. Should support a mechanism to shut down Spanning Tree Protocol PortFast-enabled interfaces when BPDUs are received to avoid accidental topology loops. Should support a mechanism to prevent edge devices not in the network administrator's control from becoming Spanning Tree Protocol root nodes. Should support a mechanism to prevent a malicious user from spoofing or taking over another user’s IP address by creating a binding table between client’s IP and MAC address, port, and VLAN Page 24 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Should have Remote Monitoring (RMON) software agent to support four RMON groups (history, statistics, alarms, and events) for enhanced traffic management, monitoring, and analysis. Should support Remote port mirroring to remotely monitor ports in a Layer 2 switch network from any other switch in the same network. Should provide a mechanism to check the health of hardware components and verify proper operation of the system data and control plane at run time and boot time Compliance Yes/No Specification Should support Multilevel security on console access preventing unauthorized users from altering the switch configuration Should support SNMPv1, SNMPv2c, and SNMPv3 Should support the ability to automatic attempt and reactivate a link that is disabled because of a network error. Should Support the ability to monitor ports in a Layer 2 switch network from any other switch in the same network. Should Support dynamic VLANs and dynamic trunk configuration across all switches. Should suppoot rapid spanning-tree reconvergence on a per-VLAN spanning-tree basis, without requiring the implementation of spanning-tree instances. Should support Unidirectional Link Detection Protocol (UDLD) and Aggressive UDLD to allow unidirectional links caused by incorrect fiber-optic wiring or port faults to be detected and disabled on fiber-optic interfaces. Should support MAC Auth Bypass (MAB) for voice allows thirdparty IP phones without an 802.1X supplicant to get authenticated using their MAC address. Should support transparent plug-and-play capability to configure the switchOS Software image and switch configuration without user intervention by utilizing dynamic IP address allocation and the assistance of other switches to facilitate installation. Page 25 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Should support automatic configuration as devices connect to the switch port, allowing auto detection and plug and play of the device onto the network. Should support the ability to monitor the network and track users by sending an alert to a management station so that network administrators know when and where users enter the network. Page 26 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram D1.3. – Specifications for Access Switches Layer 2 Switch with 24 Ethernet 10/100 ports out of which 8 are PoE Ports and 2 Nos. of Dual Purpose 10/100/1000 or SFP Ports. Make & Model: Compliance Yes/No Specification Switch should have minimum 24nos of Ethernet 10/100 with minimum 8nos 10/100 PoE ports and 2nos of dual-purpose GigE ports. Should have Minimum forwarding rate of 6.5 Mpps Support for up to 8,000 MAC addresses Should support STP, Per-VLAN STP, STP PortFast Should be able to discover the neighboring device of the same vendor giving the details about the platform, IP Address, Link connected through etc, Should support IGMP snooping v1, v2 and v3 Should Support RADIUS authentication to enable centralized control of the switch and restrict unauthorized users from altering the configuration. Support for Layer 2 trace route to identify the physical path that a packet takes from source to destination Should have Multilevel security on console access to prevent unauthorized users from altering the switch configuration. Should support a mechanism to shut down Spanning Tree Protocol PortFast-enabled interfaces when BPDUs are received to avoid accidental topology loops. Should support a mechanism to prevent edge devices not in the network administrator's control from becoming Spanning Tree Protocol root nodes. Should support a mechanism to prevent a malicious user from spoofing or taking over another user’s IP address by creating a binding table between client’s IP and MAC address, port, and VLAN Page 27 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Should have Remote Monitoring (RMON) software agent to support four RMON groups (history, statistics, alarms, and events) for enhanced traffic management, monitoring, and analysis. Should support Remote port mirroring to remotely monitor ports in a Layer 2 switch network from any other switch in the same network. Should provide a mechanism to check the health of hardware components and verify proper operation of the system data and control plane at run time and boot time Compliance Yes/No Specification Should support Multilevel security on console access preventing unauthorized users from altering the switch configuration Should support SNMPv1, SNMPv2c, and SNMPv3 Should support the ability to automatic attempt and reactivate a link that is disabled because of a network error. Should Support the ability to monitor ports in a Layer 2 switch network from any other switch in the same network. Should Support dynamic VLANs and dynamic trunk configuration across all switches. Should suppoot rapid spanning-tree reconvergence on a per-VLAN spanning-tree basis, without requiring the implementation of spanning-tree instances. Should support Unidirectional Link Detection Protocol (UDLD) and Aggressive UDLD to allow unidirectional links caused by incorrect fiber-optic wiring or port faults to be detected and disabled on fiber-optic interfaces. Should support MAC Auth Bypass (MAB) for voice allows thirdparty IP phones without an 802.1X supplicant to get authenticated using their MAC address. Should support transparent plug-and-play capability to configure the switchOS Software image and switch configuration without user intervention by utilizing dynamic IP address allocation and the assistance of other switches to facilitate installation. Page 28 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Should support automatic configuration as devices connect to the switch port, allowing auto detection and plug and play of the device onto the network. Should support the ability to monitor the network and track users by sending an alert to a management station so that network administrators know when and where users enter the network. Page 29 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram D1.4. – Specifications for Wireless LAN Controller Rack Mountable Wireless LAN Controller with 4 Nos 10/100/1000 Base T Ports with support for IEEE 802.11a, 802.11b, 802.11g, 802.11d, WMM/802.11e, 802.11h, 802.11n, 802.11u. Make & Model: Compliance Yes/No Description WLAN Controller should be based on the following key requirements: Standards Must be compliant with IEEE CAPWAP for controller-based WLANs. Hardware WLAN Controller should support upto 75 Access points in a single 1 RU chassis. WLAN controller must have atleast 4Gbps of uplink. Compatibility Must not require a separate controller for Wireless Intrusion Prevention Access Points. High Availability Must support both 1+1 and N+1 redundancy models. RF Management Must support an ability to dynamically adjust channel and power settings based on the RF environment. Radio coverage algorithm must allow adjacent APs to operate on different channels, in order to maximize available bandwidth and avoid interference Must support interference detection and avoidance. Must support coverage hole detection and correction that can be adjusted on a per WLAN basis. Must support RF Management with 40 MHz channels with 802.11n. Scalability Should support at least 75 APs per Controller. Performance Page 30 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Controller performance must remain the same if encryption is on or off for wireless SSIDs. Should support ability to adjust Delivery Traffic Indicator Message (DTIM) on a per WLAN basis to improve performance for latency sensitive applications. Compliance Yes/No Description Security Should adhere to the strictest level of security standards, including 802.11i Wi-Fi Protected Access 2 (WPA2), WPA, Wired Equivalent Privacy (WEP), 802.1X with multiple Extensible Authentication Protocol (EAP) types, including Protected EAP (PEAP), EAP with Transport Layer Security (EAP-TLS), EAP with Tunneled TLS (EAP-TTLS). Must support setting Access Control Lists (ACLs). Should support Management frame protection for the authentication of 802.11 management frames by the wireless network infrastructure. The Controller should support a capability to shun / block WLAN client in collaboration with wired IPS on detecting malicious client traffic. Controller should have the capability to detect and classify more than 1000 applications and provide application-level visibility and control. After the applications are recognized, the controller should have a provision to either drop or mark the data traffic. Controller should have a provision to profile wireless devices based on protocols, such as HTTP and DHCP, to identify the clients and enforce policies such as VLAN classification, time-bound access, QoS Guest Wireless Must support built-in web authentication. Functionality Must be able to set a maximum per-user bandwidth limit on a per-SSID basis. Page 31 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Must support user load balancing across Access Points. Controller must provide Mesh capability for Mesh supported AP. Monitoring Must be able to dedicate some APs to monitor-only for Intrusion Prevention Services. Roaming Must support client roaming across controllers separated by a layer 3 routed boundary. Solution proposed must support clients roaming across at least 50 APs. Operational Must support AP over-the-air packet capture for export to a tool such as Wireshark. Compliance Yes/No Description Should support the ability to schedule AP power on/off for energy savings. Should be able to classify over 20 different types of interference within 5 to 30 seconds. Should provide a snapshot of air quality interms of the performance and impact of interference on the wireless network identifying the problem areas. Should provide an Air Quality rating on a per- radio basis to help gauge the impact of interference on the network Should provide real-time charts showing interferers per access point, on a per-radio, per-channel basis. QOS Must support 802.11e WMM Should have Voice Call Admission Should support multicast Video call admission control mechanism and Stream prioritization. Page 32 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Support for configuring media streams with different priority to identify specific video streams for preferential quality-of-service treatment. To deliver optimal bandwidth usage, reliable multicast must use single session between AP and Wireless Controller. Should support Internet Group Management Protocol (IGMP) snooping and access point should transmits multicast packets only if a client associated to the access point is subscribed to the multicast group. Page 33 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram D1.5. – Specifications for Wireless Access Point Layer 2 Access point with 1 10/100/1000 port and 1 Serial Console Port Make & Model: Compliance Yes/No Specification The Wireless Access point should have following features Hardware General Features 10/100/1000BASE-T Auto Sensing port(s) (RJ-45) Management RJ-45 Console Port Access Points proposed must include radios for both 2.4 GHz and 5 GHz. Must have a robust design for durability, without visible vents Must include dual band antennas to support both the 2.4GHz and 5GHz operations simultaneously from single antenna. 802.11n Must support 3x3 multiple-input multiple-output (MIMO) with three spatial streams Must support simultaneous 802.11n on both the 2.4 GHz and 5 GHz radios. Must support data rates upto 300Mbps Must support 40 MHz wide channels in 5 GHz. Must support upto 22dbm of transmit power in both 2.4Ghz and 5Ghz radios. Radio Frequency (RF) The Wireless AP should have the technology to improve downlink performance to all mobile devices including one-, two-, and three spatial stream devices on 802.11n. The technology should use advanced signal processing techniques and multiple transmit paths to optimize the signal received by 802.11 clients in the downlink direction without requiring feedback and should work with all existing 802.11 clients. Page 34 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Should support configuring the access point as network connected sensor to access any network location covered by the access point to get realtime Spectrum analysis data. Must support AP enforced load-balance between 2.4Ghz and 5Ghz band. Must incorporate radio resource management for power, channel, coverage hole detection and performance optimization Roaming Must support Proactive Key Caching and/or other methods for Fast Secure Roaming. Compliance Yes/No Specification Security Must support Management Frame Protection. Should support locally-significant certificates on the APs using a Public Key Infrastructure (PKI). Must operate as a sensor for wireless IPS Encryption Access Points must support a distributed encryption/decryption model. Access Points must support Hardware-based DTLS encryption on CAPWAP Standard Monitoring Must support the ability to serve clients and monitor the RF environment concurrently. Same model AP that serves clients must be able to be dedicated to monitoring the RF environment. Flexibility AP model proposed must be able to be both a client-serving AP and a monitor-only AP for Intrusion Prevention services. Should support mesh capabilities for temporary connectivity in areas Page 35 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram with no Ethernet cabling. Mesh support should support QoS for voice over wireless. Must support 16 WLANs per AP for SSID deployment flexibility. Operational Must support telnet and/or SSH login to APs directly for troubleshooting flexibility. Power Must support Power over Ethernet, local power, and power injectors. Quality of Service 802.11e and WMM WiFi Alliance Certification for WMM and WMM power save Must support Reliable Multicast Video to maintain video quality Must support QoS and Call Admission Control capabilities. Page 36 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram D1.6 – Small Form Factor – Gigabit Ethernet Fiber Transceiver Module Make & Model : Compliance Specification Description Dimensions (H x W x D) 0.33 in x 0.53 in x 2.22 in (8.5 mm x 13.4 mm x 56.5 mm) Connectors Single-mode fiber-optic: LC-type connector Wavelength GLC-LH-SM: 1300 nm Cabling distance (maximum) GLC-LH-SM: 6.2 miles (10 km) Remarks Yes/No D1.7 – Small Form Factor – Gigabit Ethernet Copper Module Make & Model : Compliance Specification Description Dimensions (H x W x D) 0.33 in x 0.53 in x 2.22 in (8.5 mm x 13.4 mm x 56.5 mm) Connectors 1000 Base T Copper RJ45 Connector Cabling distance (maximum) Should Support Upto 100 Mtrs on CAT 5, CAT 5e and CAT6 Unshielded Twisted Pair (UTP) Cables. Page 37 of 98 Yes/No Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram D 1.8 – Unified Threat Mitigation (UTM) Firewall Appliance Make & Model : DESCRIPTION Requirement Firewall SYSTEM PERFORMANCE REQUIREMENTS Firewall Throughput 5Gbps IPSec VPN throughput 2.5Gbps concurrent session per second 0.5 million New sessions per second 15000 Total Number of VPN tunnels supported by default 2000 Number of GRE Tunnels support required number of SSL user support required by default 200 Number of Fast Ethernet ports (10/100) required 8 Number of Gigabit Ethernet 10/100/1000 copper ports required 8 Number of USB ports required which should also support 3G modems 3 Number of Console ports( copper, RJ-45 type) 1 Number of power supplies 1 System Base storage(Disk Based) required 64GB Number of Vlan interfaces support required for whole system 40960 Number of Vlan interfaces support required per physical interface 8000 Number of inbuilt DHCP servers support required for the system 400 Number of STATIC IP/MAC binding support required 10000 Number of IPv4 Firewall security policies support required 4000 Number of IPv6 Firewall security policies support Page 38 of 98 4000 Complied Yes / No JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram required Number of Multicast firewall policy support required 640 Number of Firewall IPv4 address objects support required 10000 Number of Firewall IPv6 address objects support required 10000 DESCRIPTION Requirement Number of manual URL 's that can be black listed or white listed support required 3lakh Number of File patterns( *.exe, *.pdf etc) blocking support required 3lakh should support SSL traffic scanning transparently Log support Firewall should support logging to multiple syslog servers and should generate reports by integrating with SIEM solutions. Ipsec VPN client should have WAN optimization to provide faster access to network resources for roaming users Should support User Identity Based firewall policies seamlessly without the need of any client utility be installed on hosts either manually or getting pushed through any directory servers VPN Should support L2TP, PPTP GRE tunnels Should support Ipsec Standards like Des, 3DES, AES, DH group 1,2,5,14 Virtulization & HA Maximum virtual firewalls support required Page 39 of 98 10 Complied Yes / No JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Number of Virtual firewalls support required by default 10 Should support Active-Active HA for atleast 6 firewalls in a single HA cluster Router & IPv6 support Firewall should support IPv6 Firewall should support RIP, OSPF, BGPv4, VRRP, IGMP Number of IPv4 Static routes support required for whole system 5000 Number of IPv6 Static routes support required for whole system 5000 Number of Policy based Routes support required 1000 Number of BGPv4 Neighbors support required 10000 Authentication Should support LADP, RADIUS, WindowsAD,PKI based Authentication DESCRIPTION Requirement Should also support Local User database creation & Number of Local users creation support required 10000 should have Integrated 2-Factor Authentication server support ( If not integrated, provide external equalent solution) & Number 2-factor authentication hard token support required 1000 Application control should have integrated Application control solution & Number of Application control sensors support required Page 40 of 98 320 Complied Yes / No JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Firewall should support APPLICATION CONTROL( pl provide the list of applications supported) and Total number of Applications controled should be mentioned or provide an equivelent external Hardware appliance based Application control solution which can be seamlessly integrated with firewall Traffic shaping The proposed system should support Traffic shaping & Traffic quota managemnet on per IP address and Per user group basis without the need of any client utility to be either manually installed on hosts or pushed through Directory servers Wireless security Integrated wireless Controller support required & Number of Manageable Wireless access points support required 32 End point control Should have integrated Gateway level Client Authorization, Monitoring, Control support which is able to intercept client traffic while going through the firewall and enforce client compliances pre defined parameters such as Client AV, client Firewall etc Vulnerability Scan Should have integrated Vulnerability scanner to periodically scan all Clients DESCRIPTION Proxy server Should support both explicit proxy and implicit proxy functionality either integrated within firewall appliance or provide an equivalent external hardware appliance based proxy solution Page 41 of 98 Requirement Complied Yes / No JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram which can be integrated with firewall Caching & WCCP/ICAP Firewall should support WCCP based web caching or provide an equivalent external Web caching appliance based solution which can be seamlessly integrated with firewall Server Load balancer Firewall should also act as a server load balancer without any additional load balancing switches or provide an equivalent external hardware appliance based server load balancing solution which can be seamlessly integrated with firewall DLP The proposed appliance shall have an integrated DATA LEAK PREVENTION capability for the following protocols HTTP/HTTPS POST, HTTP/HTTPS GET, FTP PUT, FTP GET, SMTP, SMTPS, IMAP, IMAPS, POP3, POP3S, NNTP, and IM( AIM, ICQ, Yahoo, MSN) or provide an equivalent external DLP appliance solution which can be integrated with firewall Wan Optimization Firewall should support first level of WAN optimization functionality integrated within firewall or provide an equivalent external WAN optimization appliance which can be integrated with firewall IPS firewall should support integrated Intrusion Prevention System(IPS) and its throughput should be based on total signatures rather than default signatures 650Mbps Antivirus and Antispyware throughput 200Mbps AV Page 42 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram DESCRIPTION URL filtering firewall should support integrated Manual as well as dynamic category based web filtering should be supported and URL database size should not be less than 30 million or provide an equivalent external Web filtering appliance based solution which can be seamlessly integrated with firewall Anti spam Firewall should support first level of Antispam functionality Page 43 of 98 Requirement Complied Yes / No JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram D2 - Specifications for Passive Components D2.1 - Fiber Optic Cable Indoor Outdoor for Backbone Make : Specification Compliance Yes / No Physical Specifications Fiber Count 6 Core Core Diameter – 8.3 microns Cladding Diameter -125.0 m (0.7) microns Core/Cladd Offset – 5 microns Cladding Non Circularity – 1% Coated Fiber Diameter- 245 (10) microns Cladding/Coating Offset - 12 microns Colored Fiber Diameter 254 (7) microns Proof Test - 0.7 Gpa Fiber Curl - > 4 microns Macrobend (100 turns, 50 mm mandrel) 0.10dB @ 1310nm, 0.10dB @ 1550nm Macrobend (1 turn on a 32mm mandrel) 0.50 db @ 1310 nm and @ 1550 nm Outer Diameter Inches. (mm) – Weight lbs/ft (Kg/km) - 0.51(13.1) 103 (177) Minimum Bend Radius Inch(cm) Loaded 10.3(26.2) Unloaded 5.1 (13.1) Max. Tensile Load lbs(Newtons) Short Term 607(2700) Page 44 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Long Term 180(800) Maximum Vertical Raise Feet(Meters) 1754(535) Optical Specifications Mode Field Diameter 9.2 Micron (0.3) @ 1310 nm 10.4 (nominal) @ 1550 nm Group Index of Refraction 0.92 @ 1310nm 1383(3)nm,1467 @1550nm Attenuation 0.35 db/km @ 1310nm 0.24 db/km @ 1550nm Maximum Dispersion 2.8 ps/nm-km 1285 tp 1330 nm Zero Dispersion Wavelength 1300-1322 nm 0.092 ps/((nm)2km) Zero Dispersion Slope Polarization Mode Dispersion LDV 0.08 ps/(km)1/2 Specification Compliance Yes / No Environmental & Mechanical Specifications Operating Temperature 400 to +700C Installation Temperature -300 to +600C Storage Temperature -400 to +750C Crush Resistance 44 N / Min Standards & Other Specifications The cables shall be designed for point to point applications as well as mid-span access, and provide a high-level of Page 45 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram protection for fiber installed in the outside plant Environment The cable shall armored with a corrugated polymer coated steel tape The singlemode fiber shall be dispersion-unshifted, fiber which meets the ITU-T G.652c requirements Shall be fully capable of handling existing and legacy singlemode applications which traditionally operate in the 1310nm and 1550nm regions. The fiber cable shall be designed to handle the new and emerging applications that utilize the “Extended” E-band, 1360-nm to 1460nm. The cable shall satisfy the requirements of ICEA S-6401999, “Optical Fiber Outside Plant Communications Cable” and Telcordia Generic requirements for FiberOptic Cable (GH-20-CORE), Section 6. The fiber cable shall also be designed to provide optimum performance from 1265nm to 1625nm making it suitable for 16-channel Course Wavelength Division Multiplexing (CDDM) applications. The Fiber cable shall be constructed with industry standard 3mm buffer tubes, stranded around a central strength member. The buffer tubes shall be compatible with standard hardware, cable routing and fan-out kits. The cable core shall be water blocked with dry waterblocking materials, making access and handling of individual tubes easier and craft-friendly. Page 46 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram D2.2 :- Light Interface Unit 24/12 Port Make : Specification & Requirement Compliance Yes / No The combination shall have a sliding tray with two 3inch (7.7 cm) storage drums and two openings with liquid-tight cable fasteners. The sliding tray allows front access and installation of fibers. The rack mount combination shelf shall be applicable for use in LANs, premises distribution systems, and small-count splice and termination applications The rack mount shelf shall be one-unit-high and be capable of housing 24 ST, 24 SC or 48 LC terminations. The shelf shall be capable of 24 fibers (48 with LCs) or to accommodate 48 mechanical splices, 64 fusion splices or 12 ribbon (mass fusion splices using optional splice trays. The sliding tray shall ride on two self-locking nylon slides used for pulling the shelf away from the frame for front access to fibers An Optional door and cable manager shall be available for use when two shelves are stacked for an aesthetic appearance. This optional accessory shall be a 1U high (1.75”) with a 3U door (5.25”). A top cover shall be available to protect from dust and falling debris. Shelf dimensions : 1.72” (4.37cm) H x 17.19” (43.7 cm) W x 11.20” (28.5 cm) D. The LIU Should be made of Aluminum The combination shall have a sliding tray with two 3inch (7.7 cm) storage drums and two openings with liquid-tight cable fasteners. The sliding tray allows front access and installation of fibers. The rack mount combination shelf shall be applicable for use in LANs, premises distribution systems, and small-count splice and termination applications The rack mount shelf shall be one-unit-high and be capable of housing 24 ST, 24 SC or 48 LC terminations. The shelf shall be capable of 24 fibers (48 with LCs) or to accommodate 48 mechanical splices, 64 fusion splices or 12 ribbon (mass fusion splices using optional splice trays. The sliding tray shall ride on two self-locking nylon slides used for pulling the shelf away from the frame for front access to fibers Page 47 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram An Optional door and cable manager shall be available for use when two shelves are stacked for an aesthetic appearance. This optional accessory shall be a 1U high (1.75”) with a 3U door (5.25”). A top cover shall be available to protect from dust and falling debris. Shelf dimensions : 1.72” (4.37cm) H x 17.19” (43.7 cm) W x 11.20” (28.5 cm) D. The LIU Should be made of Aluminum D2.3:- Fiber –Connectors / Pigtails Make : Specification & Requirement Compliance Remarks Yes / No Connector Type – SC Single Mode The connector shall Utilize a Zirconia Ferrule for fiber alignment The connector shall have push pull hardware for easier connections, as well as high optical stability The connector shall be crimped to the outer hardware, to prevent momentary disconnect when axial load is placed on the cable The connectors shall meet the following specification Length - 2 in (5.08 cm) Operating Temperature - 40 to 85O C Average Loss 0.2 db (tuned), 0.3 db (untuned) D2.4 :- Fiber Patch Cord (SC-LC) Make : Specification & Requirement Compliance Yes / No Cable Duplex Cordage Single Mode Length 3.0 Mtr Page 48 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Insertion Loss Less than 0.2 db Return Loss -50db for Single Mode Cable outside Dia 3.0 mm Tip Metal Ceramic Page 49 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram D2.5 :- CAT 6 UTP Cables Make : Specification & Requirement Compliance Yes / No Category 6 UTP Cable, 4 Pair The high performance Category 6 UTP cable shall be of the traditional round design with mylar bisector tape. The cable shall support Voice, Analog Baseband Video/Audio, Fax, Modem,Switched-56, T-1, ISDN,RS-232, RS422, RS-485, 10BASE – T Ethernet, Token Ring, 100Mbps TP-PMD, 100BASE-T Ethernet, 155 Mbps ATM, AES/EBU Digital Audio, 270 Mbps Digital Video, 622 Mbps 64-CAP ATM and emerging high-bandwidth applications, including 1 Gbps Ethernet, gigabit ATM, IEEE 1394B S100 and S400, as well as all 77 channels (550 Mhz) of analog broadband video. The cable jacket shall comply with Article 800 NEC for use as a plenum or non-plenum cable. The 4 pair UTP cable shall be UL® and c (UL®) Listed Type CMP (plenum) or CM (non-plenum). Performance shall be characterized to 550 MHz to support highbandwidth video applications All Category 6 high performance cables shall the following specification: Gauge 23 AWG Weight 25.3 lb (1000 ft) Jacket Thickness 0.022 in Outside Diameter 0.232 in Conductor Diameter 0.022 in Insulation Type High density Polyethylene Jacket Material PVC Maximum Pulling Tension 25 lbs Nom. Velocity of Propagation 0.69 Max DC Resistance 9.83 Ohms/100m Max DC Resistance Unbalanced Less than or Equal to 3% Mutual Capacitance @ 1kHz 4.95 nF/100m Operating Temperature -20 to 60° C UL Type CMR & CMG Page 50 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram *Typical worst pair swept margin. **Guaranteed margin is valid at any frequency from 1-250 MHz for the single manufacturer’s certified channel The high performance Category 6 cable shall be specified to 550 MHz and shall meet the guaranteed swept margin as follows: High Performance Cable High Performance Channel Premium Performance Channel (4 Connections) Typical Worst Guaranteed Guaranteed Pair Margin* Margin ** Margin** Insertion Loss 3.0 % 5.0% 7.5% NEXT 6.0 Db 6.0 dB 7.0 dB PSNEXT 6.0 Db 7.5 dB 8.5 dB ELFEXT 5.0 dB 6.0 dB 8.0 dB PSELFEXT 5.0 Db 8.0 dB 10.0 dB Return Loss 4.0 dB 4.0 dB 4.0 dB Frequency Range 1-550 MHz 1-250 MHz 1-250 MHz comprising the single manufacturer’s Category 6 apparatus and the single manufacturer’s High Performance series cable or Premium Performance series. Values represent margin over the TIA/EIA Category 6/Class E channel specifications D2.6 :- CAT 6 Information Outlets Make : Specification & Requirement Compliance Yes / No All Category 6 outlets shall meet or exceed Category 6 transmission requirements for connecting hardware, as specified in TIA/EIA 568-B.2-1 Commercial Building Telecommunications Cabling Standard and ISO/IEC 11801:2002 Second Edition. The Category 6 outlets shall be backward compatible with Category 5E, 5 and 3 cords and cables. The Category 6 outlets shall be of a universal design supporting T568 A & B wiring. The Category 6 outlets shall be capable of being in a modular patching situation or as a modular telecommunication outlet (TO) supporting current 10BASE-T, Token Ring, 100 Mbps TP-PMD, 155 Mbps ATM, 622 Mbps ATM using parallel transmission schemes and evolving high-speed, high-bandwidth applications, including Ethernet, 1000BASE-T and 1.2 Gbps ATM. The Category 6 outlets shall be capable of being installed at either a 45oor a 90o angle in any M-series modular faceplate, frame, or surface-mounted box avoiding the need for special faceplates. The Category 6 outlets shall have improved pair Page 51 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram splitters and wider channel for enhanced conductor placement. The outlet shall also have a low-profile wire cap, which protects against contamination and secures the connection. Multicolored identification labels shall be available to assure accurate installation. Meets or exceeds the mechanical, electrical, and clearance specifications in FCC Rules and Regulations, Part 68, Subpart F Meet or exceed the Category 6 requirements in ISO/IEC 11801, CENELEC EN 50173, and TIA/EIA568B Certifications: UL Listed, CSA Certified and AUSTEL approved. The Category 6 outlets shall meet the following Guaranteed Margin Performance and Physical Specifications: Category 6 Outlet Insertion Loss NEXT PSNEXT ELFEXT PSELFEXT Return Loss Typical Worst Pair Margin* 26.9 % 5.4 dB 4.7 dB 10.5 dB 10.8 dB 8.0 dB 1-250 MHz High Performance Premium Channel Performance Channel (4 Connections) Guaranteed Guaranteed Margin ** Margin** 5.0% 7.5% 6.0 dB 7.0 dB 7.5 dB 8.5 dB 6.0 dB 8.0 dB 8.0 dB 10.0 dB 4.0 dB 4.0 dB 1-250 MHz 1-250 MHz Frequency Range * Typical worst pair swept margin when measured with same manufacture’s Category 6 modular patch cord. **Guaranteed margin is valid at any frequency from 1-250 MHz for the single manufacturer’s certified channel comprising the single manufacturer’s Category 6 apparatus and the single manufacturer’s High Performance series cable or Premium Performance series. Values represent margin over the draft Category 6/Class E channel specifications. Specification & Requirement Compliance Yes/No Physical Specifications Dimensions - 0.8 in (20 mm) W x 0.8 in (20 mm) H x 1.2 in (31 mm) D Plastic - High-impact, flame-retardant, UL rated 94V-0 thermoplastic Connector - Copper alloy, 100 micro-inch bright solder over 100 micro-inch nickel underplate Page 52 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Outlet Wires Copper alloy, 50 micro-inch lubricated gold plating over 100 micro-inch nickel underplate Operating Temperature 14°F to 140°F (-10°C to 60°) Storage Temperature Range -40°F to 158°F (-40°C to 70°C) Humidity - 95% (noncondensing) Nominal Solid Conductor Diameter: 0.025 to 0.020 in (22 to 24 AWG) Nominal Stranded Conductor Diameter 0.64 to 0.51mm (22 to 24 AWG) Plug Retention Force 30lb (133 N) minimum Plug / Jack Contact Force 100 grams minimum per contact using FCC-8 position telecommunication plug Insertion Life 750 cycles minimum telecommunication plug using FCC-8 position D2.7 :- CAT 6 Patchmax/Jack Panel Make : Specification & Requirement Compliance Yes / No 24 port patch panels with 110 IDC connector terminations on rear – 1 U Size The patch shall have electrical performance guaranteed to meet or exceed TIA/EIA 568-B.2-1 Category 6 and ISO/IEC Category 6/Class E specifications. Page 53 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram The panel shall have vertical and horizontal cord organizers available as to improve patch cord management. The panel shall be available in 24-port configurations with universal A/B labeling and 110 connector terminations on rear of panel allowing for quick and easy installation of 22 to 24 AWG cable. The Panel shall have a black powder finish over highstrength steel. The panel shall be UL listed, UL-C certified and ACA approved. The panel shall support network line speeds in excess of 1 gigabit per second and be backward compatible with Category 5e, 5 and 3 cords and cables. The Category 6 modular jack panels shall meet or exceed the Category 6/Class E standards requirements in ISO/IEC 11801, CENLEC EN 50173 and TIA/EIA and shall be UL Listed. The panels shall be either wall or 19-inch rack mountable The panels shall meet the following specifications Category 6 Patch panel Insertion Loss NEXT PSNEXT ELFEXT PSELFEXT Return Loss Frequency Range Typical Worst Pair Margin* 64.3 % 6.6 dB 7.3 dB 6.4 dB 6.1 dB 6.6 dB 1-250 MHz HighPerformance Channel Premium Performance Channel (Category 6 Channel) (4 Connections) Guaranteed Guaranteed Margin ** Margin** 5.0% 7.5% 6.0 dB 7.0 dB 7.5 dB 8.5 dB 6.0 dB 8.0 dB 8.0 dB 10.0 dB 4.0 dB 4.0 dB 1-250 MHz 1-250 MHz * Typical worst pair swept margin when measured with same manufacture’s Category 6 modular patch cord. **Guaranteed margin is valid at any frequency from 1-250 MHz for the single manufacturer’s certified channel comprising the single manufacturer’s Category 6 apparatus and the single manufacturer’s High Performance series cable or Premium Performance series. Values represent margin over the draft Category 6/Class E channel specifications. Specification & Requirement Compliance Yes / No Page 54 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Physical Specifications Dimensions 19.0 x 1.75 x 1.60 in (48.26 x 4.38 x 4.06 cm) – Universal A/B labeling Intra-bay organizer 20.0 x 3.50 x 4.50 in (50.8 x 8.89 x 11.43 cm) – (Front Horizontal / Vertical Routing Inter-bay organizer 19.0 x 3.50 x 3.75 in (48.26 x 8.89 x 9.53 cm) – Front Horizontal routing Intra-bay organizer 19.0 x 1.72 x 4.60 in (48.30 x 4.38 x 11.70 cm)- Front & back routing 1U Wall Mount Bracket 19.0 x 3.50 x 3.59 in (48.30 x 8.89 x 12.70 cm) Operational Specifications: Operating Temperature Range: 14°F to 140°F (-10°C to 60°C) Storage Temperature Range: -40°F to 158°F (-40°C to 70°C) Humidity: 95% (noncondensing) Nominal Solid Conductor Diameter: 0.025 to 0.020 in (0.64 to 0.51 mm) (22 to 24 AWG) Nominal Stranded Conductor Diameter: 0.025 to 0.020 in (0.64 to 0.51 mm) (22 to 24 AWG) Insulation Size: 0.042 in (1.08 mm) (22 to 24 AWG) Maximum DOD Page 55 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Insulation Types: All plastic insulates (including PVC, irradiated PVC, Polyethylene, Polypropylene, PTF Polyurethane, Nylon, and FEP) Insertion Life : 750 minimum insertions of an FCC 8-Position Telecommunications Plug Front Panel: Black powder painted steel. Plastic: High-impact, thermoplastic flameretardant, UL-rated 94V-0 D2.8 & D2.9 :- Copper Patch Cord 3 Feet & 7 Feet Make : Specification & Requirement Compliance Remarks Yes / No All patch cords shall exceed TIA/EIAand ISO/IEC Category 6/Classs E specifications. All patch cords shall be backward compatible with Category 5 and Category 5E systems. The patch cords shall incorporate an anti-snag feature that provides maximum protection from snagging during moves and re-arrangements. Patch cords shall support network line speeds in excess of 1 gigabit per second. 4. Patch cords shall be UL listed, UL-C certified and AUSTEL approved. Patch cords shall be available in stranded and solid conductor in lengths to 3 Feet & 7 Feet and Beyond The Category 6 modular patch cord shall have guaranteed margin as follows: Insertion Loss NEXT PSNEXT ELFEXT Category 6 Patch Cord High Performance Channel Typical Worst Pair Margin* N.A 4.4 dB N.A N.A (4 Connections) Guaranteed Margin ** 5.0% 6.0 dB 7.5 dB 6.0 dB Page 56 of 98 Premium Performance Channel Guaranteed Margin** 7.5% 7.0 dB 8.5 dB 8.0 dB JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram PSELFEXT Return Loss Frequency Range N.A 5.9 dB 1-250 MHz 8.0 dB 4.0 dB 1-250 MHz 10.0 dB 4.0 dB 1-250 MHz * Typical worst pair swept margin when measured with same manufacture’s Category 6 modular patch cord. **Guaranteed margin is valid at any frequency from 1-250 MHz for the single manufacturer’s certified channel comprising the single manufacturer’s Category 6 apparatus and the single manufacturer’s High Performance series cable or Premium Performance series. Values represent margin over the draft Category 6/Class E channel specifications. Page 57 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram D.3 :- Integration Components Telecom / Network Racks Sl.No Specification & Requirement Compliance (Yes / No) D3.1 Rack 19” 42U Rack With 1000 MM Depth Front Glass Door with lock Back perforated full Metal Door Removable Side Panels Fan Housing unit with 4 Fans – 1 No Fans 230 VAC 90 CFM – 4 Nos 1U Horizontal Cable Manager – 6 Nos AC Main Channel 40 U – 46 U (8x15 Amps) 1 Nos AC Distribution box (6x5 Amps) 1 Nos Earthing Continuity Kit, Split Castor medium duty, STD 100 Kgs – 2 Nos Castor medium duty, FT brakes 100 Kgs – 2 Nos Hardware front panel, Square ,packet of 20 – 2 Nos D3.2 Rack 19” 15U Wall Mount Rack Front Glass Door with lock Fan Housing unit with 2 Fans – 1 No Fans 230 VAC 90 CFM – 2 Nos Page 58 of 98 Remarks JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram 1U Horizontal Cable Manager – 2 Nos AC Distribution box (6x5 Amps) 1 Nos Earthing Continuity Kit, Split Hardware front panel, Square ,packet of 20 – 1 Nos Page 59 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Section E - Network Schematic – Cable Plant Page 60 of 98 JNTUK Bid Document for Campus Networking and Local Area Network at University College of Engineering – Vizianagaram Section E - Network Schematic – Active Components Page 61 of 98 Section F F.1 Bidding procedure - Separate bid for each schedule : F.1. Offers should be made in Two parts namely, “Technical bid”, and “Financial bid” and in the format given in bid document. 1.) EMD details should be given in the “Technical bid”. 2.) Tenders will be accepted only from those who have paid the tender document fee. 4.) All correspondence should be with UCE-JNTUK contact person. 5.) A complete set of bidding documents may be purchased by interested bidders from the JNTUK contact person upon payment of the bid document price which is non-refundable or the same can be downloaded from our website. The Downloaded document should be submitted along with tender document Fee which should be enclosed in a separate cover super scribing as tender document fee along with the technical bid. Payment of bid document Cost should be by demand draft/cashier's cheque or certified cheque drawn in favour of "The Principal, University College of Engineering, Vizianagaram” and payable at Vizianagaram (India). In case the Document is downloaded from JNTUK Website and the same is not accompanied by tender document fee at the time of submission the tender will be summarily rejected. F.2. Technical Bid: It shall include the following information about the firm and/or its proposal. 1. General information on the bidder’s company in Form P-1 2. Compliance for Prequalification Criterion along with the required supporting documents indicated in the Pre-Qualification Requirements– Form P2 3. List of major customers in support of turnover in Form P-3 4. Details of service centers in AP in Form P-4 5. Certificates like ISO, etc. in Form P-5 ( Bidder’s format) 6. Manufacturer’s authorization to participate in bidding process apart from such other documents like authorization certificate for dealing in the products for which bid is submitted. ( However this will not apply to Manufacturers) in Form P-6 ( Bidder’s format) 7. Deviation(s) to technical specification, if any in Form T-1 8. Check list in Form T-2 9. Detailed technical documentation, reference to various industry standards to which the products/ services included in vendor's offer conform, and literature concerning the proposed solution in Form T-3 ( Bidder’s format) 10. Other information , if any required in the bid document in Form T-4( Bidder’s format) F.3. Financial bid: The financial bid should provide cost calculations corresponding to unit price of each item of the schedule in Form F-1. Page 62of 98 Section G G.1. Bid evaluation procedure: Bids would be evaluated for entire Schedule. Bidders should offer prices for all the items of Schedule and for the full quantity of an item of Schedule failing which such bid will not be considered. Technical bid documentation should be in the prescribed format. If a vendor has any comment to offer about the procedural aspects of this tender, it should be intimated to the Principal, University College Engineering, Vizianagaram at least in advance of two working days from the bid closure date. In case the schedule or procedure of tender processing is revised, the same shall be communicated in the JNTUK website or by e-mail/Fax as the case may be to all vendors who have paid the tender document fee. G.2. Opening of bids: Immediately after the closing time, the UCE-JNTUK contact person shall open the Technical Bid, and list them for further evaluation. The Financial bids of only those bidders who qualify in the Technical Bid will be opened at the date that will be informed by UCE-JNTUK. After evaluation of technical bids, the financial bids of only those bidders who qualify in technical evaluation will be opened. G.3. Technical Bid documentation: The Technical Bid Documentation Consists of two parts Pre-qualification bid documentation & Technical Bid documentation which shall be evaluated in two sub-steps. Firstly, the documentation furnished by the vendor shall be examined prima facie to see if the product/Service offered, technical skill base and financial capacity and other vendor attributes claimed therein are consistent with the needs of this project. In the second step, UCE-JNTUK may ask vendor(s) for additional information, visit to vendors site and/or arrange discussions with their professional, technical faculties to verify claims made in Pre-qualification bid documentation and In the second step, UCE-JNTUK may ask vendor(s) for additional information, visit to vendors site and/or arrange discussions with their professional, technical faculties to verify claims made in technical bid documentation. G.4. Award Criterion: Final choice of firm to execute the project shall be made on the basis of conformity to technical specifications, appropriateness of the product offered, capability of bidder to execute and service the project and appropriateness of financial offer from the point of view of cost-effectiveness over the entire maintenance period for the product/services. G.5. Award of Contract: Evaluation of financial bids will be schedule wise. UCE-JNTUK reserves the right to award the contract schedule wise. G.6. Period of validity of bids 1. Bids shall remain valid for the 90 days or duration specified in the bid document, after the date of bid opening prescribed by UCE-JNTUK. A bid valid for a shorter period shall be rejected as non-responsive. 2. In exceptional circumstances, the UCE-JNTUK may solicit the bidders' consent to an extension of the period of validity. The request and the responses thereto shall be made in writing. The bid security shall also be suitably extended. A bidder granting the request will not be permitted to modify its bid. Page 63of 98 G.7. Submission of bids 1. The bidders shall seal the Technical and Financial bids in Two separate envelopes which in turn are to be kept in a super cover, duly marking the envelopes as “Technical bid" and "Financial bid", and “Composite bid” respectively. 2. The envelopes shall then be sealed in an outer envelope. The inner and outer envelopes shall: a. be addressed to The Principal, University College of Engineering, JNTUK Vizianagaram Campus, Vizianagaram-535 003 (AP). b. Bear the project Name/Title indicated in the tender call, and bear a statement for i. Technical bid OR Composite Bid “Do not open before bid opening day and time”, ii. Financial bid “ Don't open until evaluation of technical bid” 3. The outer envelopes shall clearly indicate the name and address of the bidder to enable the bid to be returned unopened in case it is declared "late". 4. If the outer envelope is not sealed and marked as required above, UCE-JNTUK will assume no responsibility for the bid's misplacement or premature opening. G.8. Deadline for submission of bids 1. Bids must be submitted at UCE-JNTUK, Vizianagaram Campus no later than the bid submission date and time specified in the tender call notice. 2. The UCE-JNTUK may, at its discretion, extend this deadline for the submission of bids by amending the tender call, in which case all rights and obligations of the UCE-JNTUK and bidders previously subject to the deadline will thereafter be subject to the deadline as extended. G.9. Late bids Any bid not received by the UCE-JNTUK contact person by the deadline for submission of bids will be rejected and returned unopened to the bidder. G.10. Modification and withdrawal of bids 1. The bidder may modify or withdraw its bid after the bid's submission, provided that written notice of the modification including substitution or withdrawal of the bids, is received by the UCE-JNTUK prior to the deadline prescribed for submission of bids. 2. The bidder's modification or withdrawal notice shall be prepared, sealed, marked and dispatched in a manner similar to the original bid. 3. No bid can be modified subsequent to the deadline for submission of bids. 4. No bid can be withdrawn in the interval between the deadline for submission of bids and the expiration of the period of bid validity. Withdrawal of a bid during this interval will result in the forfeiture of its bid security (EMD). G.11 General business information: The bidder shall furnish general business information to facilitate assessment of its professional, technical and commercial capacity and reputation. Page 64of 98 G.12 Bid security i.e. earnest money deposit (EMD) 1. The bidder shall furnish, as part of its bid, a bid security for the amount specified in the tender call notice. 2. The bid security is required by UCE-JNTUK to: a. assure bidder's continued interest till award of contract and b. conduct in accordance with bid conditions during the bid evaluation process. 3. The bid security shall be in Indian rupees and shall be a bank guarantee, or an irrevocable letter of credit or cashier’s certified check, issued by a reputable bank scheduled in India and having at least one branch office in Hyderabad. 4. Unsuccessful bidder's bid security will be discharged or returned as promptly as possible but not later than thirty (30) days after the expiration of the period of bid validity prescribed by UCE-JNTUK. 5. The successful bidder's bid security will be discharged upon the bidder signing the contract, and furnishing the performance security of 5% for a period of 3 years. 6. The bid security may be forfeited: a. If a bidder withdraws its bid during the period of bid validity or b. In the case of a successful bidder, if the bidder fails: i. To sign the contract in time; or ii. To furnish performance security. G.13 Genuineness of the quoted product 1. Bidder should provide an undertaking on the genuineness of the quoted product. The undertaking should be provided in the following format. 2. "All products supplied against this enquiry will be genuine, new and procured directly from Principals or through their Authorized channels. Refurbished products, counterfeit products, products procured from unauthorized sources or grey market will not be supplied. Documents Should be provided to verify the source and date of purchase if required " 3. Bidder should provide proof of placing the order on Principal Manufacturer or on their Authorized Channels/Distributors for all the Active equipment including cables and interface cards within one week of receiving the order. Failing which the order will be cancelled and EMD will be forfeited. 4. Bidder should provide the Service Contract Number along with the Products at the time of product delivery. Principal University College of Engineering JNTU Kakinada Vizianagaram Campus Vizianagaram Page 65of 98 Bid letter form From: (Registered name and address of the bidder.) To: The Principal, University College of Engineering, JNTUK Vizianagaram Campus, Vizianagaram-535 003 (AP) Sir, Having examined the bidding documents and amendments there on, we the undersigned, offer to provide services/execute the works including supply, delivery installation of hardware, firm wares and soft ware’s as the case may be, in conformity with the terms and conditions of the bidding document and amendments there on, for the following project in response to your tender call dated ....................... Project title: We undertake to provide services/execute the above project or its part assigned to us in conformity with the said bidding documents for an estimated sum of Rs ................... (total bid amount in words and figures) which may vary in accordance with the schedule of prices attached herewith and coverage options made by UCE-JNTUK, or its user organisation.If our bid is accepted, we undertake to; 1. provide services/execute the work according to the time schedule specified in the bid document, 2. obtain the performance guarantee of a bank in accordance with bid requirements for the due performance of the contract, and 3. agree to abide by the bid conditions, including pre-bid meeting minutes if any, which remain binding upon us during the entire bid validity period and bid may be accepted any time before the expiration of that period. 4. We understand that you are not bound to accept the lowest or any bid you may receive, nor to give any reason for the rejection of any bid and that you will not defray any expenses incurred by us in bidding. Place: Bidder’s signature Date: and seal. Page 66of 98 Form P-1 Bidder Information 1 2 Name of the organization Year of establishment Registered Office Address 3 4 5 6 7 8 A B 9 10 11 12 Phone No. Fax No. Email Total No. of branch offices in AP Total Support engineers at At Head office ( No.) At branch offices (No.) Whether Manufacturer? If Yes, Provide relevant documents Whether authorized dealer/ Service Provider? If Yes, Provide relevant documents Details of EMD furnished Details of certificates enclosed. Page 67of 98 Form P-2 Compliance Statement for Prequalification Criteria S.No Pre-Qualification Criteria Document Required 1 The Bidder must have been in the business of providing Networking Certificate of Incorporation / Firm Infrastructure facilities for a minimum Registration Certificate to be enclosed period of 5 years. 2 An Undertaking from the bidder on their letter head along with the Blank The Bidder bidding for part of the tender Un-priced Format of the Quoted will be rejected. components without pricing ALONG WITH PART NOS as a proof. 3 The Bidder should be an ISO 9001:2008 Copy of the ISO 9001:2008 Certificate Certified Company for Networking. 4 A Proof to this effect should be enclosed in the form of Balance sheets The bidder should have a minimum and IT Clearance Certificates/Statutory Annual turnover of 8 Crores each year for Auditor's Certificate Stating that the the past 3 years (2010-11, 2011-12, 2012Annual Sales Turnover for the Last 3 13). years of 2010-11, 2011-12, 2012-13 along with certified Balance Sheets. 5 The Bidder should have an minimum Statutory Auditor's Certificate turnover of Rs. 5 Crores per annum for indicating the turnover pertaining to the past 3 years (2010-11, 2011-12, 2012Networking Business. 13) pertaining to networking domain. 6 The bidder should be an Authorized Integrator / Business Partner / Reseller of the Brand that is proposed for the supplies for a minimum period of 5 years in Andhra Pradesh as on bid calling date. A Letter from the OEM indicating Status of the Bidder who is an Authorised Integrator / Business Partner / Reseller for the past 5 years. 7 All the Active Network Components proposed should be from a single Manufacturer only except for UTM Appliance and the past experience of the bidders should be for the same make of network actives which the bidder is An Undertaking from the bidder on their letter head with the blank Un priced format of the Products ALONG WITH PART NOS Quoted. Page 68of 98 Criteria Met Yes/No quoting against this tender. 8 The Original Equipment Manufacturer of A copy of the ISO Certificates of the Active Components should be an ISO 9001 OEMs of the Products Quoted. & ISO 14001 Certified. 9 In addition to Bidders support, Service Support should be available directly from the Principals. Bidder should provide The Service Contract Number from the OEM to the Purchaser. Quoted OEM Products should have spares depot in Andhra Pradesh or should maintain adequate spares at the site as indicated below.. 9a If the Spares Depot is not available in the State of Andhra Pradesh for the For Core switches: A Complete chassis OEM an undertaking from the OEM with all active cards / modules of the along with the Bidder indicating their same make and model. willingness to provide the Working Spares at Site. 9b. If the Spares Depot is not available in the State of Andhra Pradesh for the Access switches: Maintain 10% of OEM an undertaking from the OEM Switches for Access Connectivity of the along with the Bidder indicating their same make and model. willingness to provide the Working Spares at Site. 10 The Active Components Proposed should be supported by the Principal An undertaking from the OEM about Manufacturer for Technical Assistance on their TAC should be provided. 24 x 7 bases thru a Technical Assistance Center (TAC). 11 The Bidder should submit the Manufacturers authorization for the proposed Product on OEM’s letter head to participate for this tender mentioning the bid reference. A letter from OEM indicating the clear Addresses of their Spares depots along with an undertaking from the Bidder that he will provide the Service Contract Number along with the Products at the time of product delivery. Direct Authorization Letters from the OEMs indicating the Bid Reference to participate in this tender should be provided. Page 69of 98 12 The Bidder should be an Authorized A Letter of certificate from the OEM Partner for the Proposed Active indicating the Bidder's is Association. Components for the last 5 years. 13 The Active components proposed should A Letter from the OEM / industry have at least 30% market share in specialists like IDC. Switching & Routing in India. 14 The products quoted should not be A Letter from the OEM indicating their declared End of Life at the time of delivery uninterrupted support for the product and OEM should support the products for the next 5 years. quoted for at least 5 years. 15 A letter of undertaking from the Bidder The Passive Components proposed Should with Blank Un-priced List of be from the Single Manufacturer for both components ALONG WITH PART NOS indicating the Manufacturer of the Fiber and Copper Components. Product. 16 The Passive installation should be certified for ‘Extended Product and Application An undertaking from the OEM on their warranty’ for a minimum period of 20 willingness to certify the product years from the date of Installation by the supplied and Installed by the Bidder. OEM. 17 The bidder must have a full-fledged support centre in Andhra Pradesh to Details of the Bidder's support centers support the installation & should have to be provided in the prescribed OEM qualified engineers to attend to the format. support as & when required by UCEJNTUK Vizianagaram within 24 hours. 17a Copy of the Certificates of bidder's The Bidder should have at least 10 OEM Employees along with an undertaking certified engineers for Active Components that the certified engineers are proposed (Certificates to be attached permanent employees of the bidder's along with the Technical Bid). organization. 17b Copy of the Certificates of bidder's Should have minimum 10 OEM Certified Employees along with an undertaking cabling installation Personnel. (Certificates that the certified engineers are permanent employees of the bidder's to be submitted). organization. Page 70of 98 18 The Bidder should have installed at least 3 campus networks in Educational Institutions with at least 500 copper Nodes and about 5 Kilo Meters of Fiber Optic Cabling for backbone as a single order & should have been in the business of providing Turnkey Solutions for Campus Networking for the last 3 years. Documentary Evidence should be provided in the form of Installation Reports/Performance Certificates / Purchase Orders. Form P -3 List of Major Customers S.No Customer Full address Year of supply Item Name Form P-4 Details of service centers in AP Page 71of 98 Turn over S.No Full Address of service center Contact person with phone No. Page 72of 98 No. of support engineers Form T-1 Sl. No. Item Specification Required Specification of proposed item Specification Higher/Lower Note : Cross reference to the Technical product brochure is to be provided. Form T - 2 Check List Compliance/agreed/enclosed/ deviation statement. The following are the particulars of compliance/deviations from the requirements of the tender specifications. Bid document reference Remarks 1. Delivery period 2. Form P-1 3. Form P-2 4. Form P-3 5. Form P-4 6. Form P-5 7. Form P-6 8. Form T-1 9. Form T-2 10. Form T-3 11. Form T-4 Page 73of 98 12. Form F-1 13. Pre-qualification criterion 14. Technical specifications 15. Financial bid format 16. General instruction to bidders 17. Standard procedure for bid evaluation 18. General condition of proposed contract (GCC) 19. Special Condition of proposed Contract (SCC) The specifications and conditions furnished in the bidding document shall prevail over those of any other document forming a part of our bid, except only to the extent of deviations furnished in this statement. Place: Bidder’s signature Date : and seal. NOTE: For every item appropriate remarks should be indicated like ‘no deviation’, ’agreed’, ’enclosed’ etc. as the case may be. Page 74of 98 Form F-1 Consolidated Price Schedule for the Tender Requirements Form No. Item details with make and model Warranty 2 3 1 Active Components which include F.1.1 F.1.2 F.1.3 Total price with taxes and duties etc with warranty as per Col. 3 (INR) 4 3 Years U T M Firewall Passive Components 1 Year Integration Charges 1 Years Total Project cost (INR) Bid amount in words ( Col. No. 4 ) ___________________________________________ (Signature of Bidder with stamp) Page 75of 98 Form F .1.1 – Financial Bid for Active Components S.No. Part Code Description UOM Qty 1 Layer 3 12 Port Gigabit Ethernet SFP Switch with IP Base as per Detailed Specifications Listed under Section D1.1 No 1 1a 8 x 5 x NBD Hardware replacement warranty for 3 Years (for 3 Years Qty Multiplied by 3) No 3 1b Single Mode LX/LH Fiber SFP Transceiver Module as per Detailed Specifications Listed under Section D1.6 No 8 1c 1000 Base T - Gigabit SFP Module as per Detailed Specifications Listed under Section D1.7 No 2 2 Layer 2 Fully Managed Switch with 24 10/100 Mbps Ports and 2 SFP/T Uplinks as per Detailed Specifications Listed under Section D1.2 No 5 2a 8 x 5 x NBD Hardware Replacement warranty for 24 Port 10/100 + 2 T/SFP LAN Lite Image Switch for 3 years (for 3 Years Qty Multiplied by 3) No 15 2b Single Mode LX/LH Fiber SFP Transceiver Module as per Detailed Specifications Listed under Section D1.6 No 11 Core Switch Access Switches UTM Fire Wall Page 76of 98 Unit Price INR Extd Price INR Unified Threat Mitigation Appliance Firewall for 1000 Users with 3 Year Subscription as per Detailed Specifications Listed under Section D1.8 No 1 Description UOM Qty 4 Wireless LAN Controller Supporting 50 Access Points, Video Streaming, High Availability, IPv6, Voice, Wireless Mesh technology and Mobile Security as per detailed specifications listed under Section D1.4 No 1 4a 8 x 5 x NBD Hardware Replacement Warranty for Wireless LAN Controller for 3 years. (for 3 Years Qty Multiplied by 3) No 3 4b Single Mode LX/LH Fiber Transceiver Module As per the detailed specifications listed under Section D1.6 No 8 No 30 3 S.No. Part Code Wireless LAN Components - Controller Wireless LAN Components – Access Points 5 Wireless Access Point 802.11n Compliance, 3 x 3 MIMO, 3 Spatial Streams, Internal Antennae, N Registration Domain as per detailed specifications listed under Section D1.5 Page 77of 98 Unit Price INR Extd Price INR 5a 8 x 5 x NBD Hardware Replacement Warranty for Wireless Access Point for 3 years Directly provided by the principal manufacturer. (for 3 Years Qty Multiplied by 3) No 90 6 Power Injector Supporting the above mentioned access point No 8 7 Layer 2 Managed Switch with 24 10/100 Mbps Ports Out of which 8 are PoE and 2 nos of Dual Purpose Ports as per the detailed Specifications listed under Section D1.3 No 10 S.No. 7a Part Code Description UOM Qty 8 x 5 x NBD Hardware Replacement Warranty for 24 Port 10/100 + 2 10/100/1000 Mbps Managed Switch for 3 years Directly provided by the Principal Manufacturer for the above Layer 2 Switch (for 3 Years Qty Multiplied by 3) No 30 Total Exclusive of Taxes VAT Service Tax Total Inclusive of Taxes Page 78of 98 Unit Price INR Extd Price INR Form F.1.2 - Price Bid for Network – Passive Components S# Part Code Description UOM Qty Copper 1 Cat 6 UTP Cable (Roll of 305 Mtrs) Box 80 2 Cat 6 Information Outlets No 388 3 Cat 6 24 Port Jack Panels Loaded No 19 4 Single / Dual Face Plates No 388 5 Cat 6 7ft Patch Cords - User End No 388 6 Cat 6 7ft Patch Cords - Switch End No 442 1 6 Core Outdoor Optical fiber cable Single Mode Mtr 7000 2 12 Port LIU (Shelf, 600G2, 1U, Fixed) No 13 3 600G2 Panel, Accepts 12 Duplex SC Adapters No 13 4 SC Duplex Adapter, SM No 156 5 RoloSplice Kit E/W 2x Fusion Splice Tray for 1U Shelf No 13 6 SC Pigtails 1 Mtr - Single mode No 156 7 SC-LC Fiber Optic Patch cord 3 Mtr No 48 Mtr 4500 Fiber Components Installation & Integration Components 1 1" Casing & Capping Page 79of 98 Unit Price INR Extd Price INR 2 2" Casing & Capping Mtr 4500 3 1" Flexible Pipe Mtr 325 4 2" Flexible Pipe Mtr 325 5 15U Wall Mountable Rack with standard accessories No 15 6 42 U Closed Rack with standard accessories No 2 7 1" HDPE Pipe with accessories Mtr 6100 8 1" GI Pipe with accessories Mtr 900 9 150X50 MM Industrial Duct Mtr 100 TOTAL without Taxes VAT Total Inclusive of Taxes Page 80of 98 Form F.1.3 - Price Bid for Network – Integration Charges S# Part Code 1 Labor 2 Labor Description Laying of Cat 6 UTP Cable (Roll of 305 Mtrs) Termination of the Cat 6 Information Outlets 3 UOM Mtr Qty 24400 No 388 Labor Termination of the Cat 6 24 Port Jack Panels - Loaded No 19 4 Labor Fixing of the Single / Dual Face Plates No 388 5 Labor Cat 6 7ft Patch Cords - User End No 388 6 Labor Cat 6 7ft Patch Cords - Switch End No 442 Labor Installation of the 1" Casing & Capping Mtr 4500 8 Labor Installation of the 2" Casing & Capping Mtr 4500 9 Labor Installation of the 1" Flexible Pipe Mtr 325 10 Labor Installation of the 2" Flexible Pipe Mtr 325 Labor Installation of the 15U Wall Mountable Rack with standard accessories No 15 12 Labor Installation of the 42 U Closed Rack with standard accessories No 2 13 Labor Laying of 6 Core Outdoor Optical fiber cable in the HDPE/GI Pipe Mtr 7000 Labor Fixing of the 12 Port LIU (Shelf, 600G2, 1U, Fixed) No 13 15 Labor Fixing of the 600G2 Panel, Accepts 12 Duplex SC Adapters No 13 16 Labor Fixing of the SC Duplex Adapter, SM No 156 Labor RoloSplice Kit E/W 2x Fusion Splice Tray for 1U Shelf No 13 7 11 14 17 Page 81of 98 Unit Price INR Extd. Price INR 18 Labor Splicing / Termination of the SC Pigtails 1 Mtr - Single mode 19 Labor SC-LC Fiber Optic Patch cord 3 Mtr No 48 Labor Laying of the 1" HDPE Pipe with accessories Mtr 6100 Labor Laying of the 1" GI Pipe with accessories Mtr 900 Labor Installation of the 150X50 MM Industrial Duct Mtr 100 23 Labor Digging & Refilling of the Hard Rocky Soil Mtr 6100 24 Labor Digging & Refilling of the Road Mtr 500 20 21 22 TOTAL Without Taxes Service Tax Total Inclusive of Service Tax Page 82of 98 No 156 Tender Notice No.JNTUK UCEV/Campus wide Networking,Lab Equipment&Furniture/2014-15/3,Date: 05-07-2014 Item no: 3 (Dept.of ME) FURNITURE FOR ACADEMIC BLOCK-2 Page 83of 98 JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY KAKINADA UNIVERSITY COLLEGE OF ENGINEERING - VIZIANAGARAM Via: Cantonment, Dwarapudi (Vill & Post), Vizianagaram - 535 003. Phone:08922-277388 Fax 08922-277488 FURNITURE FOR ACADEMIC BLOCK-2 1. Specifications for Drawing Table with Stool: Quantity: 120 Units Drawing table with stool:-Drawing table dimensions 1”x1” M.S CRCA square pipe with 16 gauge. Height (42”-36”) x 20” (width) 24” (length) of the over all M.S structure. Foot rest is to be provided.18mm P.L.B all round teak wood beading for plank for the use of mini draughter, pencils box etc. M.S structure will be with good quality painting process. Drawing table with stool:- Drawing board dimensions are 810x520x15mm. Bottom two stiffeners are provided. Stools: stool dimensions are 1” O.D round pipe with top frame is 1”x1”x2.3mm angular frame. Stool dimensions are 27” (H) x15” (w) X15” (L). Total M.S structure will be good quality positioning process. Top plate is 15”x15”x1” teak wood plank with neat polishing. 2. THREE SEATER CLASS ROOM BENCHES with attached DESK Quantity: 220 units Specifications Three seater made with powder coated steel tube and hydraulic bending Top 18mm pre laminated particle board with texture finish and round edges with edge binding tape Depth of main desk 400 mm, seat 350mm and length of the table should be 1500mm with comfortable inclination Page 84of 98 3. TWO SEATER CLASS ROOM BENCHES with attached DESK Quantity: 150 units Specifications: Two seater made with powder coated steel tube and hydraulic bending Top 18mm pre laminated particle board with texture finish and round edges with edge binding tape Depth of main desk 400 mm, seat 350mm and length of the table should be 1100mm with comfortable inclination. Page 85of 98 Page 86of 98 Tender Notice No.JNTUK UCEV/Campus wide Networking,Lab Equipment&Furniture/2014-15/3,Date: 05-07-2014 Item no:4 Equipment & Furniture FOR Boys Hostel Block-2 Page 87of 98 JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY KAKINADA UNIVERSITY COLLEGE OF ENGINEERING - VIZIANAGARAM Via: Cantonment, Dwarapudi (Vill & Post), Vizianagaram - 535 003. Phone:08922-277388 Fax 08922-277488 TENDER ITEMS FOR NEW BOYS HOSTEL S. No Item Particulars Qty I Cots 1 00 II a Dinning Tables (Eight Seat) 1 8 Rice & Multipurpose Cooker (30 Kg) 1 Rice & Multipurpose Cookers (15 Kg) 2 c Milk & Tea Beaking Unit (40 lt) 1 d Idly Trays (SS) – to suit 30 kg capacity Rice cooker 1 b e Double burner LP Gas stoves for ready use 2 f Dosa & Chapathi Unit (Big) 1 g Steam Boiler (100 lt) 1 h Wet Grinders (5 kgs) 2 i Steam Pipe line j Water lines for steam boiler and cookers k Gas Pipe Line Page 88of 98 III. a b c d e f g h i j k l m n IV a b c d e Stain Steel (Dinning Crockery) Kitchen Utensils (Indalium Tubs) Dinning Plates Tiffin Plates Water Glasses Tea, Coffee & Milk Glasses Water Jugs Curd & Curry Cups Buckets 10" Buckets 9" Spoons Ladle's No - 3 (Size) Ladle's No - 4 (Size) Basins big (550gms) Basins small (450gms) Panja (Hastalu) Tubs (5 kgs) Tubs (10 kgs) Tubs (20 kgs) Tubs (30 kgs) Tubs (50 kgs) 350 350 350 350 20 1200 6 15 500 20 20 6 12 20 2 2 2 2 2 COTS SPECIFICATIONS FOR NEW BOYS HOSTEL I M. S. Cot of size is 75” (L) X 30” (W) X 18” (H) M. S. Sheet: 14 Gauge M. S. Pipe: 1 ¼” round pipe (16 gauge) MESS ITEMS SPECIFICATIONS FOR NEWBOYS HOSTEL II a) Dinning Tables - 8 Seated type :Eight seated dinning table M.S. Channel framed with bearing mounted moisture proof painted, preeminently sealed and revolving type seat bars and level adjusters. Top and seats should be covered with stainless steel sheets of 304 quality, 1mm thickness. b) Rice & Multipurpose Cookers :16 SWG of quality 304 stainless steel Page 89of 98 30 g & 15 kg capacities c) Milk & Tea Baking units, 40 liters capacity :18 SWG of quality 304 stainless steel, with safety valves. 40 iters capacity d. Idly Trays (SS) – to suit 30 kg capacity Rice cooker:Stainless steel trays which are suitable to use in 30 kg capacity rice cooker e. Double Burner LP Gas stoves for ready use :M.S. Framed and stainless steel covered double burner stoves for ready use The dimensions are 2’x4’x1.6’ f. Dosa and Chapathi units for ready use :M.S. Framed and stainless steel covered for ready use The top should be 14 mm M.S. plate. The dimensions are 6”x21/”’x3” g. Steam boiler (100 liters) with multi fuel capability, safety valves and water level indicator and drain outlet valves The capacity should be 100 liters. Double jacketed heavy duty body with inner 14 SWG stainless steel body and outer 8 mm M.S. body Should be suitable for either LP Gas or fire wood. Should be provided with all safety valves, water level indicators and drain outlet valves h. Wet Grinders – 5kg capacity :To be used for dosa mix, idly mix, to prepare chutneys & Masala as per requirement. Page 90of 98 i. Steam Pipe line:Covered with 6 mm Asbestos rope M. S/SS Pipe line of ½” / ¾” of suitable length. j. Water lines for steam boiler and cookers:Should be provided with 15 mm G. I. material for both boiler and cookers k. Gas Pipe Line :As per IS 6044 Part I Specifications 5 + 5 way manifold connection along with regulators, cylinder pigtails & main line regulator shut of controlling valves, clamping etc. III. Dinning Crockery (Stainless Steel ware):- a) Dinning & Tiffin plates b) Milk, Tea, Coffee & Water glasses c) Water Jugs d) Curd and curry cups e) Buckets of various sizes to serve curries, sambar, rasam and curd etc. f) Spoons of small and large sizes g) Ladle’s for serving liquids, Rice etc. h) Basins of various sizes to serve rice etc. i) Stainless steel & indalium lids of various for covering IV. Kitchen Utensils :- a) Indalium tubs of 5 kg to 50 kg sizes (for cooking) b) Iron items like Kalai, Tawa etc c) Iron Paddle’s for stirring and cooking d) Cutlery, Knives & Choppers Page 91of 98 e) Coconut grter f) Lemon Squeezers g) Wooden rolls for making chapathi, Puri etc. Page 92of 98 Tender Notice No.JNTUK UCEV/Campus wide Networking,Lab Equipment&Furniture/2014-15/3,Date: 05-07-2014 Item no:5 Sports Equipment Page 93of 98 JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY KAKINADA UNIVERSITY COLLEGE OF ENGINEERING - VIZIANAGARAM Via: Cantonment, Dwarapudi (Vill & Post), Vizianagaram - 535 003. Phone:08922-277388 Fax 08922-277488 Specifications for Sports Equipments: Sl.No 1 Sport Football Goal Post Mobile Set Brand NELCO NS 5014FME Qty 01 Set Specification Goal Post Size is 2.44mts Height, 7.32mts Width of the goal Post, 12 cm rounded width, Pipe Size is 4” dia with White Color Powder Coated with Galvanized hub solid rubber wheels. 2 Hockey Goal Post Mobile Set NELCO NS 5080HGP 01 Set Goal Post Pipe size 70MM X 50MM 3.66mts width, 2.14mts Height of the goal Post, 3.66mts Length of the back board, 1.20cm width of the side board, 3.66mts Length of the crossbar, 460 mm Board Thickness, 80cm Height of the Board, 51mm to75mm Goal pole Width & Length, water Proof laminated wood backboard (black color) Pole White Color Powder Coated with Galvanized hub solid rubber wheels. 3 Handball Goal Post Mobile Set NELCO NS 5060HGM 01 Set Goal Post Size is 3mts Height of The Goal Post, 2 mts Length of The Goal Post, 3mts Length of the Cross Bar, 8cm Width of the Cross Bar, Pipe size is 80 MM SQ White Color Powder Coated. With Galvanized hub solid rubber wheels. 4 Volley ball Poles NELCO NS 5020FVP & NS 5020CVP 04 Sets Iron pole Size is 4” rounded width, 2.55m height With ratchet, with crank system Net Height Adjustable socket with White Color 02 Sets Powder Coated. Page 94of 98 5 Throw ball Poles NELCO 03 Sets Iron Pole Size is 4’’ Dia 3 mts Height of the pole, Net Height Adjustable socket with White Color Powder Coated. 6 7 8 Badminton Indoor Poles Tennis Poles Hurdles NELCO NS 5040CBP 05 Sets 65MM SQ. Pipe competition pro mobile NELCO NS 5030FTP NELCO N11320HS 02 Sets Pole size 4” dia fixed post with pulley for 12 Nos Made out of stainless Steel 50mm tubes Badminton post with steel counter balance weight for stability wt.150kg. Perset. net adjustment.1.07 mts Height. aluminum sliding tubes, easy selector system to adjust weight to required height, adequate toppling force as per IAAF Rules. 9 Sports EPE Mats NELCO NS 2060EPN 03 Nos Mat size is 2M X 1M X60 MM with Non tearing cover (Anti-Slip Bottom). Page 95of 98 JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY KAKINADA UNIVERSITY COLLEGE OF ENGINEERING - VIZIANAGARAM Via: Cantonment, Dwarapudi (Vill & Post), Vizianagaram - 535 003. Phone:08922-277388 Fax 08922-277488 Tender Notice No.JNTUK UCEV/Campus wide Networking,Lab Equipment&Furniture/2014-15/3,Date: 05-07-2014 Item no: 06 (Dept.of CE) Equipment for Survey & SM lab Page 96of 98 Sl.No:01 TECHNICAL SPECIFICATION OF TOTAL STATION – 2” ACCURACY 1. Magnification : 2. Effective diameter of objective : 3. Shortest focusing distance : 4. Laser Pointer : 5. Operating Temperature : 6. Angular accuracy : 7. Least count : 8. Distance measurement accuracy : 9. Clamps (Horizontal & Vertical) : 10. Plummet : 11. Compensator : 12. Compensator range : 13. Distance measurement with Single Prism: 14. Distance measurement without Prism: 15. Internal Point Memory : 30X 45mm 1.5m Should be available -200C to + 500C 2” Accuracy 0.1’/1” Selectable 3mm + 2ppm ( With Prism) Locking System/End less Frictional Moment Built in Laser plummet Dual Axis Dual axis with +/- 3.5’ 3000m or Better 400 m or better Approximately above 1,00,000 lakh points /128 MB memory capacity should be available 16. Power supply : Through Rechargeable Lithium ion Batteries 17. Operating time : 10-12 Hours of backup in all modes or Better 18. Communication (Data Transfer) : USB port, Integrated Blue tooth, Pen drive or better Dual side display 19. Display : Dual side display 20. On Board Operating Software : Windows CE 6.0 with TFT Color Display With Touch Screen Facility at least minimum on one side or better 21. Key Pad : Should have full Alphanumeric Key Pad at least on One Side 22. Water & Dust protection : IP 66 or better 23. Angle Measurement : Absolute Encoding System 24. On Board Software Should Perform : Data Collection in 3D, Resection, Setting Out – Points/Arcs/Lines, Point Projection – Offset from the line/ Offset to the line, Intersection- Line/Arcs, Feature Coding, Traverse Adjustment with detailed report, Offset- Angle ( Hidden points), compute distance (MLM), Remote Object Height, Area Calculation – Division of Area Parallel or Hinge Wise, Link CSV Files and Existing Jobs Files, CSV File can be created On the Instrument itself, DXF File can be kept as Background in the map of Current Job or better. Page 97of 98 Sl.No:02 TECHNICAL SPECIFICATION OF AUTOMATIC LEVEL AUTOMATIC LEVEL - 04 No.s Magnification: 24 x Accuracy: +/-2mm (1km Double Run) With Standard Accessories Sl.No:03 TECHNICAL SPECIFICATION OF UNIVERSAL TESTING MACHINE 1. Universal Testing Machine, 1 No. (1000 KN) (MECHANICAL) Max. Capacity: 1000 KN 1st Measuring Range: 0-1000 KN Resolution: 2.00 KN 2nd Measuring Range: 0-500 KN Resolution: 1.00 KN 3rd Measuring Range: 0-250 KN Resolution: 0.50 KN 4th Measuring Range: 0-100 KN Resolution: 0.20 KN Max. Clearance for Tensile Test: 50 - 850 mm Max. Clearance for Compression Test: 0 - 850 mm Clearance between columns: 750 mm Ram Stroke: 250 mm Straining / Piston speed at no load: 0-80 (mm / min.) Electric Supply: 2.60 KW Dimensions: 2420 mm L x 820 mm W x 2900 mm H Weight (Approx.): 5500 KGS. Page 98of 98